Changes for page 1 Communication

Last modified by Hunter on 2024/07/01 10:54

From version 12.1
edited by Ben
on 2022/07/14 14:03
Change comment: There is no comment for this version
To version 15.1
edited by Ben
on 2022/07/14 14:50
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -58,39 +58,41 @@
58 58  (% style="text-align:center" %)
59 59  [[image:1624348978863-771.png||queryString="width=812&height=494" height="487" width="800" class="img-thumbnail"]]
60 60  
61 +(% class="wikigeneratedid" %)
61 61  == ==
62 62  
63 63  == **2 Communication with Allen-Bradley CompactLogix L1769** ==
64 64  
65 -=== **Overview** ===
66 -
67 67  (((
68 68  This example introduces the establishment of Ethernet communication between Wecon V-box and Allen-Bradley L1769. It is introduced through three parts: PLC software configuration, V-box software configuration, and hardware wiring.
68 +
69 +
69 69  )))
70 70  
71 71  (((
72 -
73 +(% class="wikigeneratedid" id="HSoftwareconfigurationofPLC" %)
74 +(((
75 +**Software configuration of PLC**
73 73  )))
74 74  
78 +(% class="wikigeneratedid" id="HPLCprogrammingsoftware" %)
75 75  (((
76 -== **Software configuration of PLC** ==
80 +**1)PLC programming software**
81 +)))
77 77  
78 -=== **PLC programming software** ===
83 +[[image:image-20220714113935-3.png||height="324" width="270"]]
79 79  
80 - [[image:image-20220714113935-3.png]]
81 -
82 -=== **New PLC project** ===
83 -
85 +(% class="wikigeneratedid" id="HNewPLCproject" %)
84 84  (((
85 -Click New Project and select the PLC model.
87 +**2)New PLC project**
86 86  )))
87 87  
88 88  (((
89 - [[image:image-20220714114247-4.png]]
91 +Click New Project and select the PLC model.
90 90  )))
91 91  
92 92  (((
93 - [[image:image-20220714114257-5.png]]
95 +[[image:image-20220714114247-4.png||height="298" width="552"]] [[image:image-20220714114257-5.png||height="445" width="551"]]
94 94  )))
95 95  
96 96  (((
... ... @@ -98,26 +98,37 @@
98 98  )))
99 99  
100 100  (((
101 -=== **Set Ethernet parameters** ===
103 +(% class="wikigeneratedid" id="HSetEthernetparameters" %)
104 +(((
105 +**3)Set Ethernet parameters**
106 +)))
102 102  
103 103  (((
109 +(((
104 104  Follow the steps below to configure Ethernet parameters
105 105  )))
112 +)))
106 106  
107 107  (((
115 +(((
108 108  PLC IP address:192.168.40.101
109 109  )))
118 +)))
110 110  
111 111  (((
121 +(((
112 112  default gateway:192.168.40.1
113 113  )))
124 +)))
114 114  
115 115  (((
127 +(((
116 116  subnet mask:255.255.255.0
117 117  )))
130 +)))
118 118  
119 119  (((
120 - [[image:image-20220714115012-6.png]]
133 +[[image:image-20220714115012-6.png]]
121 121  )))
122 122  
123 123  (((
... ... @@ -125,36 +125,48 @@
125 125  )))
126 126  
127 127  (((
128 -== **V-box software configuration** ==
141 +(% class="wikigeneratedid" id="HV-boxsoftwareconfiguration" %)
142 +(((
143 +**V-box software configuration**
144 +)))
129 129  
130 -=== **V-box programming software** ===
146 +(% class="wikigeneratedid" id="HV-boxprogrammingsoftware" %)
147 +(((
148 +**1)V-box programming software**
149 +)))
131 131  
132 - [[image:image-20220714115214-7.png]]
151 +(% class="wikigeneratedid" %)
152 +(((
153 + [[image:image-20220714115214-7.png||height="276" width="456"]]
154 +)))
133 133  
156 +(% class="wikigeneratedid" id="HConfiguredevicenetwork" %)
157 +(((
158 +**2)Configure device network**
159 +)))
134 134  
135 -=== **Configure device network** ===
136 -
137 137  (((
162 +(((
138 138  Click the Configuration Download button[[image:image-20220714115308-8.png||height="22" width="15"]], It is used to configure the device network, update the device time, obtain the device machine code, check the device network, etc.
139 139  )))
165 +)))
140 140  
141 141  (((
142 -In the example below, the IP address of V-Box is configured as 192.168.40.66, and the networking method is 4G connection.
168 +(((
169 +In the example below, the IP address of V-Box is configured as 192.168.40.66, and the networking method is 4G connection [[image:image-20220714115440-9.png||height="425" width="791"]]
143 143  )))
144 -
145 - [[image:image-20220714115440-9.png||height="425" width="791"]]
146 146  )))
147 147  )))
148 -
149 -== **V-net add device** ==
150 150  )))
151 151  
175 +(% class="wikigeneratedid" id="HV-netadddevice" %)
152 152  (((
153 -Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device. 
177 +**3)V-net add device**
154 154  )))
179 +)))
155 155  
156 156  (((
157 - [[image:image-20220714115640-10.png||height="430" width="797"]]
182 +Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device.   [[image:image-20220714115640-10.png||height="430" width="797"]]
158 158  )))
159 159  
160 160  (((
... ... @@ -162,18 +162,26 @@
162 162  )))
163 163  
164 164  (((
165 -=== **Set communication port parameters** ===
190 +(% class="wikigeneratedid" id="HSetcommunicationportparameters" %)
191 +(((
192 +**4)Set communication port parameters**
193 +)))
166 166  
167 -In the device list on the left, find the Vbox that communicates with the L1769, click it and select configuration,communication port configuration in the main interface to add a communication protocol.
168 -
169 - [[image:image-20220714115848-11.png||height="432" width="802"]]
195 +In the device list on the left, find the Vbox that communicates with the L1769, click it and select configuration,communication port configuration in the main interface to add a communication protocol. [[image:image-20220714115848-11.png||height="432" width="802"]]
170 170  )))
171 171  
172 -
173 173  The communication port is selected as Ethernet, the device type is selected as Allen-Bradley, the protocol is Allen-BradleyMicro850_FreeTag EthemetIP, and the IP is the internal IP address of the L1769 PLC. The port number is 44818.
174 174  
200 +[[image:image-20220714143820-1.png]]
175 175  
202 +After adding the protocol Allen-BradleyMicro850_FreeTag, click[[image:image-20220714143838-2.png]]icon add label.
176 176  
204 +[[image:image-20220714143849-3.png]]
205 +
206 +
207 +== Engineering production ==
208 +
209 +
177 177  == **Siemens S7-1200** ==
178 178  
179 179  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]]
image-20220714143820-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +1.4 MB
Content
image-20220714143838-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +520 bytes
Content
image-20220714143849-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +1.3 MB
Content