Changes for page 1 Communication

Last modified by Hunter on 2024/07/01 10:54

From version 12.1
edited by Ben
on 2022/07/14 14:03
Change comment: There is no comment for this version
To version 28.1
edited by Ben
on 2022/08/20 16:50
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,7 +1,5 @@
1 -= **1 General communication with PLC** =
1 += **Modbus RTU** =
2 2  
3 -== **Modbus RTU** ==
4 -
5 5  === **V-BOX as master** ===
6 6  
7 7  Select the protocol “(% class="mark" %)Modbus RTU Slave(All Fuction)”,
... ... @@ -47,77 +47,298 @@
47 47  |(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils)
48 48  |0F (Write multiple bits)
49 49  
50 -== **WECON LX3V PLC** ==
48 += **WECON PLC** =
51 51  
52 -Select the protocol (% class="mark" %)"WECON LX3V"
50 +Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM
53 53  
54 -(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity same with PLC.
52 +**HMI Settings**
55 55  
56 -(% class="mark" %)WECON PLC RS422 port,default communication parameters is 9600,1,7,ZEVEN
54 +|**Item**|**Settings**|**Note**
55 +|Protocol|WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM|
56 +|Connection|RS422/RS485|
57 +|Baud rate|9600|
58 +|Data bit|7|
59 +|Parity|EVEN|
60 +|Stop bit|1|
61 +|PLC station No.|1|
57 57  
63 +**Address List**
64 +
65 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
66 +|(% rowspan="6" %)Bit|X|X|Xo|0~~303237|
67 +|Y|Y|Y o|0~~303237|
68 +|M|M|M d|0~~99999|
69 +|T|T|T d|0~~99999|
70 +|C|C|C d|0~~99999|
71 +|S|S|S d|0~~99999|
72 +|(% rowspan="8" %)Word|X|X|Xo|0~~303237|
73 +|Y|Y|Y o|0~~303237|
74 +|M|M|M d|0~~99999|
75 +|T|T|T d|0~~99999|
76 +|C|C|C d|0~~199|
77 +|D|D|D d|0~~7999|
78 +|S|S|S d|0~~99999|
79 +|SD|SD|SD d|8000~~9999|
80 +
81 +**Cable Wiring**
82 +
83 +* **RS485**
84 +
58 58  (% style="text-align:center" %)
59 -[[image:1624348978863-771.png||queryString="width=812&height=494" height="487" width="800" class="img-thumbnail"]]
86 +[[image:12.PLC Protocol_html_1897d92be6948d58.png||data-xwiki-image-style-alignment="center" height="223" width="393" class="img-thumbnail"]]
60 60  
61 -== ==
88 +* **RS422**
62 62  
63 -== **2 Communication with Allen-Bradley CompactLogix L1769** ==
90 +(% style="text-align:center" %)
91 +[[image:12.PLC Protocol_html_5c7fca9a70da2ee8.png||data-xwiki-image-style-alignment="center" height="247" width="389" class="img-thumbnail"]]
64 64  
65 -=== **Overview** ===
93 +**✎Note:**
66 66  
95 +* HMI COM3 is available in PI8000 series and COM3 is in COM2(hardware PIN 7 and PIN 8) .
96 +* If PLC <= 20 points,such as LX3V-1208/LX3V-0806 PLC,PLC RS485A and RS485B mean PLC COM2 RS485+ and RS485- .PLC COM2 can support modbus. Please refer to PLC COM2 setting manual.
97 +
98 +[[https:~~/~~/drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing>>url:https://drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing]]
99 +
100 +
101 +== **HMI and Wecon LX5V serial communication** ==
102 +
103 +This example introduces the establishment of serial port communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
104 +
105 +**Software configuration of PLC**
106 +
107 +**1)PLC programming software**
108 +
109 +[[image:image-20220810164710-1.png]]
110 +
111 +
112 +**2)New PLC project**
113 +
114 +Click New Project and select the PLC model.
115 +
116 +[[image:image-20220810172412-1.png]]
117 +
118 +
119 +**3)Set Serial port parameters**
120 +
121 +Follow the steps below to configure Serial port parameters
122 +
123 +Baud rate:115200
124 +
125 +Data bit:8
126 +
127 +Stop bit:1
128 +
129 +Parity:No verification
130 +
131 +[[image:image-20220810165759-3.png]]
132 +
133 +
134 +**4)Registers list**
135 +
136 +[[image:image-20220811102219-3.png]]
137 +
138 +
139 +**HMI software configuration**
140 +
141 +**1)HMI programming software**
142 +
143 + [[image:image-20220810171237-4.png]]
144 +
145 +**2)New HMI project**
146 +
147 +Click New Project and select the HMI model.
148 +
149 +[[image:image-20220810172010-5.png]]
150 +
151 +
152 +**3)Set communication port parameters**
153 +
154 +Click the communication configuration button on the left to find the communication protocol with LX5V. After selecting the protocol, configure the communication parameters of the COM port.
155 +
156 +Baud rate:115200
157 +
158 +Data bit:8
159 +
160 +Stop bit:1
161 +
162 +Parity:No verification
163 +
164 +[[image:image-20220811104012-1.png]]
165 +
166 +
167 +**hardware connection**
168 +
169 +**1)Hardware wiring diagram**
170 +
171 +This example introduces WeconHMI with LX5V PLC to establish communication through serial port. The connection diagram is as follows:
172 +
173 +
174 +
175 +[[image:image-20220811103005-4.png]]
176 +
177 +[[image:image-20220811103227-7.png]]
178 +
179 +The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC.
180 +
181 +== **HMI and Wecon LX5V-N Ethernet communication** ==
182 +
183 + This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
184 +
185 +**Software configuration of PLC**
186 +
187 +**1)PLC programming software**
188 +
189 +[[image:image-20220810164710-1.png]]
190 +
191 +**2)New PLC project**
192 +
193 +Click New Project and select the PLC model.
194 +
195 +[[image:image-20220811115454-1.png]]
196 +
197 +**3)Set Ethernet port parameters**
198 +
199 +Follow the steps below to configure Ethernet parameters
200 +
201 +PLC IP address:192.168.39.200
202 +
203 +default gateway:192.168.39.1
204 +
205 +subnet mask:255.255.255.0
206 +
207 +[[image:image-20220811140530-2.png]]
208 +
209 +**4)Registers list**
210 +
211 +[[image:image-20220811102219-3.png]]
212 +
213 +**HMI software configuration**
214 +
215 +**1)HMI programming software**
216 +
217 + [[image:image-20220810171237-4.png]]
218 +
219 +**2)New HMI project**
220 +
221 +Click New Project and select the HMI model.
222 +
223 +[[image:image-20220810172010-5.png]]
224 +
225 +**3)Set communication port parameters**
226 +
227 +Click the project setting button on the left to configure the IP address of the HMI machine to ensure that the HMI and PLC IP remain in a local area network.
228 +
229 +HMI IP address:192.168.39.201
230 +
231 +default gateway:192.168.39.1
232 +
233 +subnet mask:255.255.255.0
234 +
235 +[[image:image-20220811170753-2.png]]
236 +
237 +Next, click Communication Settings to configure the IP of the HMI communication object.
238 +
239 +[[image:image-20220811163047-1.png]]
240 +
241 +**hardware connection**
242 +
243 +**1)Hardware wiring diagram**
244 +
245 +This example introduces WeconHMI with LX5V-N PLC to establish communication through ethernet. The connection diagram is as follows:
246 +
247 +[[image:image-20220811170248-1.png]]
248 +
249 +The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC.
250 +
251 +(% style="text-align:center" %)
252 +[[image:1624348978863-771.png||queryString="width=812&height=494" height="487" width="800" class="img-thumbnail"]]
253 +
254 += **Rockwell PLC** =
255 +
256 +== **Communication with AB CompactLogix L1769** ==
257 +
67 67  (((
259 +(((
68 68  This example introduces the establishment of Ethernet communication between Wecon V-box and Allen-Bradley L1769. It is introduced through three parts: PLC software configuration, V-box software configuration, and hardware wiring.
69 69  )))
70 70  
71 -(((
72 72  
73 73  )))
74 74  
75 75  (((
76 -== **Software configuration of PLC** ==
267 +(% class="wikigeneratedid" id="HSoftwareconfigurationofPLC" %)
268 +(((
269 +**Software configuration of PLC**
270 +)))
77 77  
78 -=== **PLC programming software** ===
272 +(% class="wikigeneratedid" id="HPLCprogrammingsoftware" %)
273 +(((
274 +**1)PLC programming software**
275 +)))
79 79  
80 - [[image:image-20220714113935-3.png]]
277 +[[image:image-20220714162600-1.png]]
81 81  
82 -=== **New PLC project** ===
83 -
279 +(% class="wikigeneratedid" id="HNewPLCproject" %)
84 84  (((
85 -Click New Project and select the PLC model.
281 +**2)New PLC project**
86 86  )))
87 87  
88 88  (((
89 - [[image:image-20220714114247-4.png]]
285 +(((
286 +Click New Project and select the PLC model.
90 90  )))
288 +)))
91 91  
92 92  (((
93 - [[image:image-20220714114257-5.png]]
291 +[[image:image-20220714162617-2.png]]
94 94  )))
95 95  
96 96  (((
97 97  
296 +
297 +[[image:image-20220714162652-4.png]]
98 98  )))
99 99  
100 100  (((
101 -=== **Set Ethernet parameters** ===
301 +(% class="wikigeneratedid" id="HSetEthernetparameters" %)
302 +(((
303 +**3)Set Ethernet parameters**
304 +)))
102 102  
103 103  (((
307 +(((
308 +(((
104 104  Follow the steps below to configure Ethernet parameters
105 105  )))
311 +)))
312 +)))
106 106  
107 107  (((
315 +(((
316 +(((
108 108  PLC IP address:192.168.40.101
109 109  )))
319 +)))
320 +)))
110 110  
111 111  (((
323 +(((
324 +(((
112 112  default gateway:192.168.40.1
113 113  )))
327 +)))
328 +)))
114 114  
115 115  (((
331 +(((
332 +(((
116 116  subnet mask:255.255.255.0
117 117  )))
335 +)))
336 +)))
118 118  
119 119  (((
120 - [[image:image-20220714115012-6.png]]
339 +[[image:image-20220714162713-5.png]]
121 121  )))
122 122  
123 123  (((
... ... @@ -125,67 +125,139 @@
125 125  )))
126 126  
127 127  (((
128 -== **V-box software configuration** ==
347 +(% class="wikigeneratedid" id="HV-boxsoftwareconfiguration" %)
348 +(((
349 +**V-box software configuration**
350 +)))
129 129  
130 -=== **V-box programming software** ===
352 +(% class="wikigeneratedid" id="HV-boxprogrammingsoftware" %)
353 +(((
354 +**1)V-box programming software**
355 +)))
131 131  
132 - [[image:image-20220714115214-7.png]]
357 +(% class="wikigeneratedid" %)
358 +(((
359 + [[image:image-20220714162725-6.png]]
360 +)))
133 133  
362 +(% class="wikigeneratedid" id="HConfiguredevicenetwork" %)
363 +(((
364 +**2)Configure device network**
365 +)))
134 134  
135 -=== **Configure device network** ===
136 -
137 137  (((
368 +(((
369 +(((
138 138  Click the Configuration Download button[[image:image-20220714115308-8.png||height="22" width="15"]], It is used to configure the device network, update the device time, obtain the device machine code, check the device network, etc.
139 139  )))
140 140  
141 141  (((
142 -In the example below, the IP address of V-Box is configured as 192.168.40.66, and the networking method is 4G connection.
374 +In the example below, the IP address of V-Box is configured as 192.168.40.66, and the networking method is 4G connection
143 143  )))
144 -
145 - [[image:image-20220714115440-9.png||height="425" width="791"]]
146 146  )))
147 147  )))
148 148  
149 -== **V-net add device** ==
379 +(((
380 +(((
381 +[[image:image-20220714162737-7.png]]
382 +
383 +
150 150  )))
385 +)))
386 +)))
387 +)))
151 151  
389 +(% class="wikigeneratedid" id="HV-netadddevice" %)
152 152  (((
153 -Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device. 
391 +**3)V-net add device**
154 154  )))
393 +)))
155 155  
156 156  (((
157 - [[image:image-20220714115640-10.png||height="430" width="797"]]
396 +(((
397 +Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device.   [[image:image-20220714162752-8.png]]
158 158  )))
159 159  
160 -(((
161 161  
162 162  )))
163 163  
164 164  (((
165 -=== **Set communication port parameters** ===
404 +(% class="wikigeneratedid" id="HSetcommunicationportparameters" %)
405 +(((
406 +**4)Set communication port parameters**
407 +)))
166 166  
409 +(((
167 167  In the device list on the left, find the Vbox that communicates with the L1769, click it and select configuration,communication port configuration in the main interface to add a communication protocol.
411 +)))
168 168  
169 - [[image:image-20220714115848-11.png||height="432" width="802"]]
413 +[[image:image-20220714162805-9.png]]
170 170  )))
171 171  
172 -
416 +(((
173 173  The communication port is selected as Ethernet, the device type is selected as Allen-Bradley, the protocol is Allen-BradleyMicro850_FreeTag EthemetIP, and the IP is the internal IP address of the L1769 PLC. The port number is 44818.
418 +)))
174 174  
420 +[[image:image-20220714162814-10.png]]
175 175  
176 176  
177 -== **Siemens S7-1200** ==
423 +(((
424 +After adding the protocol Allen-BradleyMicro850_FreeTag, click[[image:image-20220714143838-2.png]]icon add label.[[image:image-20220714162827-11.png]]
425 +)))
178 178  
179 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]]
427 +(% class="wikigeneratedid" id="HEngineeringproduction" %)
428 +(((
429 +**5)Engineering production**
430 +)))
180 180  
432 +(% class="wikigeneratedid" %)
433 +(((
434 +(((
435 +According to your own needs, use the V-NET client software to edit the required data monitoring points.
436 +)))
437 +
438 +[[image:image-20220714162841-12.png]]
439 +
440 +
441 +(((
442 +**hardware connection**
443 +)))
444 +)))
445 +
446 +(((
447 +**1)Hardware wiring diagram**
448 +)))
449 +
450 +(((
451 +(((
452 +This example introduces Wecon V-box with Allen-Bradley L1769 PLC to establish communication through Ethernet. The connection diagram is as follows:
453 +)))
454 +
455 +[[image:image-20220714162856-13.png]]
456 +
457 +(((
458 +The above are all the steps for establishing Ethernet communication between Wecon V-box with Allen-Bradley L1769 PLC.
459 +
460 +
181 181  == **Allen-Bradley Ethernet DF1** ==
182 182  
183 183  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]]
184 184  
465 +
466 += **Siemens PLC** =
467 +)))
468 +)))
469 +
470 +== **Siemens S7-1200** ==
471 +
472 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]]
473 +
185 185  == **Communication with S7-200 Smart** ==
186 186  
187 187  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]]
188 188  
478 += **Delta PLC** =
479 +
189 189  == **Delta DVP Ethernet** ==
190 190  
191 191  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
... ... @@ -212,7 +212,7 @@
212 212  
213 213  = **2 User define protocol** =
214 214  
215 -More serial port script instruction,please refer manual:[[Lua script function>>doc:V-BOX.V-Net.1\.User Manual.04 Lua Script.01 Lua Functions.WebHome]]~-~-->[[3.Serial port operation>>url:http://docs.we-con.com.cn/wiki/vbox/view/HMI/04.Lua%20script%20%20function%20and%20operation/01.Lua%20script%20function/#H3.Serialportoperation]]
506 +More serial port script instruction,please refer manual:[[Lua script function>>doc:V-BOX.V-Net.Manual.04 Lua Script.01 Lua Functions.WebHome]]~-~-->[[3.Serial port operation>>url:http://docs.we-con.com.cn/wiki/vbox/view/HMI/04.Lua%20script%20%20function%20and%20operation/01.Lua%20script%20function/#H3.Serialportoperation]]
216 216  
217 217  == **Read the temperature sensor.** ==
218 218  
image-20220714143820-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +1.4 MB
Content
image-20220714143838-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +520 bytes
Content
image-20220714143849-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +1.3 MB
Content
image-20220714160006-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +1.3 MB
Content
image-20220714160034-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +135.2 KB
Content
image-20220714160120-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +58.8 KB
Content
image-20220714160335-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +264.1 KB
Content
image-20220714160412-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +58.5 KB
Content
image-20220714160439-6.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +104.0 KB
Content
image-20220714160541-7.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +13.7 KB
Content
image-20220714160651-8.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +135.2 KB
Content
image-20220714160843-9.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +165.9 KB
Content
image-20220714160943-10.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +50.2 KB
Content
image-20220714161014-11.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +94.3 KB
Content
image-20220714161120-12.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +94.3 KB
Content
image-20220714161229-13.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +62.5 KB
Content
image-20220714161445-14.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +131.2 KB
Content
image-20220714162600-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +58.8 KB
Content
image-20220714162617-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +1.3 MB
Content
image-20220714162629-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +58.5 KB
Content
image-20220714162652-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +58.5 KB
Content
image-20220714162713-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +104.0 KB
Content
image-20220714162725-6.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +13.7 KB
Content
image-20220714162737-7.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +135.2 KB
Content
image-20220714162752-8.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +135.2 KB
Content
image-20220714162805-9.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +165.9 KB
Content
image-20220714162814-10.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +50.2 KB
Content
image-20220714162827-11.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +94.3 KB
Content
image-20220714162841-12.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +62.5 KB
Content
image-20220714162856-13.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +131.6 KB
Content
image-20220820164423-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +18.4 KB
Content