... ... @@ -907,8 +907,12 @@
907 907  |Word|ZR|ZR|ZR h|0~~FFFF|
908 908  |Word|D|D|D d|0~~99999|
909 909  
910 -**3)PLC Settings (GX Works2 )**
910 +**3)Configure the communication protocol**
911 911  
912 +[[image:image-20220825142659-1.png]]
913 +
914 +**4)PLC Settings (GX Works2 )**
915 +
912 912  Create a project
913 913  
914 914  Set PLC IP, subnet mask and gateway;
... ... @@ -927,10 +927,6 @@
927 927  
928 928  Restart PLC device;
929 929  
930 -**4)Configure the communication protocol**
931 -
932 -[[image:image-20220825142659-1.png]]
933 -
934 934  **5)Cable Wiring**
935 935  
936 936  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
... ... @@ -939,7 +939,7 @@
939 939  
940 940  Mitsubishi QJ71E71 Ethernet communication module;
941 941  
942 -**1)V-BOX Settings**
942 +**V-BOX Settings**
943 943  
944 944  |**Items**|**Settings**|**Note**
945 945  |Protocol|MIT QJ71E71 MELSEC|
... ... @@ -947,7 +947,7 @@
947 947  |Port No.|1025|Must be the same as the PLC setting
948 948  |PLC station No.|0|Must be the same as the PLC setting
949 949  
950 -**2)Address List**
950 +**Address List**
951 951  
952 952  |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
953 953  |(% rowspan="18" %)Bit|X|X|X h|0~~1FFF|
... ... @@ -979,8 +979,17 @@
979 979  |Z|Z|Z d|0~~15|
980 980  |ZR|ZR|ZR h|0~~FE7FF|
981 981  
982 -**3)PLC Settings(GX Works2)**
982 +**HMI Communication Settings**
983 983  
984 +1) Enable HMI Ethernet in [Project Settings];
985 +
986 +
987 +2) Set PLC IP in [Device IP] settings;
988 +
989 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2d566cb5ffb2618c.png?width=554&height=190&rev=1.1||alt="12.PLC Protocol_html_2d566cb5ffb2618c.png"]]
990 +
991 +**PLC Settings(GX Works2)**
992 +
984 984  * Click [Ethernet/CC IE/MELSECNET];
985 985  * Please select [Ethernet] as network type;
986 986  * Set station I/O number according to situation (For example, 0000 means that the module is connected to PLC CPU in first order);
... ... @@ -997,14 +997,11 @@
997 997  * Save settings;
998 998  * Download project into PLC and restart it
999 999  
1000 -**4)Configure the communication protocol**
1009 +**Cable Wiring**
1001 1001  
1002 -[[image:image-20220825143728-1.png]]
1003 -
1004 -**5)Cable Wiring**
1005 -
1006 1006  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png"]]
1007 1007  
1013 +
1008 1008  = **台达 PLC** =
1009 1009  