Changes for page 1 Communication

Last modified by Hunter on 2024/07/01 10:54

From version 122.1
edited by Ben
on 2022/08/25 14:58
Change comment: There is no comment for this version
To version 119.1
edited by Ben
on 2022/08/25 14:31
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -862,60 +862,6 @@
862 862  
863 863  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
864 864  
865 -
866 -== **L02 Serial Protocol** ==
867 -
868 -Mitsubishi L02 series CPU built-in Ethernet port.
869 -
870 -**V-BOX Settings**
871 -
872 -|**Items**|**Settings**|**Note**
873 -|Protocol|MIT L02 CPU MELSEC|
874 -|Connection|Ethernet|
875 -|Port No.|1025|Must be the same as the PLC setting
876 -|PLC station No.|0|Must be the same as the PLC setting
877 -
878 -**Address List**
879 -
880 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
881 -|Bit|X|X|X h|0~~FFFF|
882 -|Bit|Y|Y|Y h|0~~FFFF|
883 -|Bit|M|M|M d|0~~9999|
884 -|Bit|L|L|L d|0~~9999|
885 -|Bit|F|F|F d|0~~9999|
886 -|Bit|B|B|B h|0~~FFFF|
887 -|Bit|V|V|V d|0~~2047|
888 -|Bit|TC|TC|TC d|0~~9999|
889 -|Bit|SS|SS|SS d|0~~9999|
890 -|Bit|SC|SC|SC d|0~~9999|
891 -|Bit|CS|CS|CS d|0~~9999|
892 -|Bit|CC|CC|CC d|0~~9999|
893 -|Bit|SB|SB|SB h|0~~FFFF|
894 -|Bit|SM|SM|SM d|0~~2047|
895 -|Bit|STS|STS|STS d|0~~1023|
896 -|Bit|S|S|S d|0~~9999|
897 -|Bit|DX|DX|DX h|0~~FFFF|
898 -|Bit|DY|DY|DY h|0~~FFFF|
899 -|Bit|TS|TS|TS d|0~~9999|
900 -|Bit|Dbit|Dbit|Dbit d.d|0~~99999.0~~15|
901 -|Word|W|W|W h|0~~FFFF|
902 -|Word|TN|TN|TN d|0~~99999|
903 -|Word|SN|SN|SN d|0~~99999|
904 -|Word|CN|CN|CN d|0~~99999|
905 -|Word|R|R|R d|0~~99999|
906 -|Word|SW|SW|SW h|0~~FFFF|
907 -|Word|Z|Z|Z d|0~~99999|
908 -|Word|ZR|ZR|ZR h|0~~FFFF|
909 -|Word|D|D|D d|0~~99999|
910 -
911 -**Communication Settings**
912 -
913 -
914 -**Cable Wiring**
915 -
916 -
917 -
918 -
919 919  == **L02 Ethernet Protocol** ==
920 920  
921 921  Mitsubishi L series CPU built-in Ethernet port.
... ... @@ -961,8 +961,12 @@
961 961  |Word|ZR|ZR|ZR h|0~~FFFF|
962 962  |Word|D|D|D d|0~~99999|
963 963  
964 -**3)PLC Settings (GX Works2 )**
910 +**3)Configure the communication protocol**
965 965  
912 +[[image:image-20220825142659-1.png]]
913 +
914 +**4)PLC Settings (GX Works2 )**
915 +
966 966  Create a project
967 967  
968 968  Set PLC IP, subnet mask and gateway;
... ... @@ -981,10 +981,6 @@
981 981  
982 982  Restart PLC device;
983 983  
984 -**4)Configure the communication protocol**
985 -
986 -[[image:image-20220825142659-1.png]]
987 -
988 988  **5)Cable Wiring**
989 989  
990 990  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
... ... @@ -993,7 +993,7 @@
993 993  
994 994  Mitsubishi QJ71E71 Ethernet communication module;
995 995  
996 -**1)V-BOX Settings**
942 +**V-BOX Settings**
997 997  
998 998  |**Items**|**Settings**|**Note**
999 999  |Protocol|MIT QJ71E71 MELSEC|
... ... @@ -1001,7 +1001,7 @@
1001 1001  |Port No.|1025|Must be the same as the PLC setting
1002 1002  |PLC station No.|0|Must be the same as the PLC setting
1003 1003  
1004 -**2)Address List**
950 +**Address List**
1005 1005  
1006 1006  |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1007 1007  |(% rowspan="18" %)Bit|X|X|X h|0~~1FFF|
... ... @@ -1033,8 +1033,17 @@
1033 1033  |Z|Z|Z d|0~~15|
1034 1034  |ZR|ZR|ZR h|0~~FE7FF|
1035 1035  
1036 -**3)PLC Settings(GX Works2)**
982 +**HMI Communication Settings**
1037 1037  
984 +1) Enable HMI Ethernet in [Project Settings];
985 +
986 +
987 +2) Set PLC IP in [Device IP] settings;
988 +
989 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2d566cb5ffb2618c.png?width=554&height=190&rev=1.1||alt="12.PLC Protocol_html_2d566cb5ffb2618c.png"]]
990 +
991 +**PLC Settings(GX Works2)**
992 +
1038 1038  * Click [Ethernet/CC IE/MELSECNET];
1039 1039  * Please select [Ethernet] as network type;
1040 1040  * Set station I/O number according to situation (For example, 0000 means that the module is connected to PLC CPU in first order);
... ... @@ -1051,14 +1051,11 @@
1051 1051  * Save settings;
1052 1052  * Download project into PLC and restart it
1053 1053  
1054 -**4)Configure the communication protocol**
1009 +**Cable Wiring**
1055 1055  
1056 -[[image:image-20220825143728-1.png]]
1057 -
1058 -**5)Cable Wiring**
1059 -
1060 1060  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png"]]
1061 1061  
1013 +
1062 1062  = **台达 PLC** =
1063 1063  
1064 1064  == **DVP 以太网协议** ==
image-20220825143728-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -124.7 KB
Content