Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 4 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,10 +1,10 @@ 1 -= (% style="color:inherit; font-family:inherit" %)**W econPLC**(%%) =1 += (% style="color:inherit; font-family:inherit" %)**WECON PLC**(%%) = 2 2 3 -== **LX3V 3 +== **LX3V Serial Protocol** == 4 4 5 -Supported series: W econLX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM5 +Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM 6 6 7 -**1) V-BOXsetting**7 +**1)PLC Settings** 8 8 9 9 |**Item**|**Settings**|**Note** 10 10 |Protocol|WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM| ... ... @@ -15,9 +15,8 @@ 15 15 |Stop bit|1| 16 16 |PLC station No.|1| 17 17 18 -**2)Address List** 18 +**2)PLC Address List** 19 19 20 - 21 21 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 22 22 |(% rowspan="6" %)Bit|X|X|Xo|0~~303237| 23 23 |Y|Y|Y o|0~~303237| ... ... @@ -36,9 +36,9 @@ 36 36 37 37 **3)Configure the communication protocol** 38 38 39 -[[image:image-20220824152217-1.png ||alt="图片-20220824152217-1.png"]]38 +[[image:image-20220824152217-1.png]] 40 40 41 -**4) CableWiring**40 +**4)hardware connection** 42 42 43 43 * **RS422** 44 44 ... ... @@ -217,7 +217,7 @@ 217 217 218 218 [[image:image-20220824110724-1.png]] 219 219 220 -== ** Micro850_FreeTag** ==219 +== **CompactLogix Protocol** == 221 221 222 222 ((( 223 223 ((( ... ... @@ -356,7 +356,7 @@ 356 356 357 357 ((( 358 358 ((( 359 -Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device. 358 +Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device. [[image:image-20220714162752-8.png]] 360 360 ))) 361 361 362 362 ... ... @@ -791,7 +791,7 @@ 791 791 792 792 Mitsubishi FX5U series PLC 793 793 794 -** 1)V-BOXSettings**793 +**HMI Settings** 795 795 796 796 |**Items**|**Settings**|**Note** 797 797 |Protocol|Mitsubishi FX5U| ... ... @@ -799,7 +799,7 @@ 799 799 |Port No.|5002|Must be the same as the PLC setting 800 800 |PLC station No.|0| 801 801 802 -** 2)Address List**801 +**Address List** 803 803 804 804 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 805 805 |(% rowspan="15" %)Bit|X|X|X o|0~~303237| ... ... @@ -827,11 +827,12 @@ 827 827 |D|D|D d|0~~7999| 828 828 |SD|SD|SD d|0~~11999| 829 829 830 -** 3)PLC Settings (GX Works 3)**829 +**PLC Settings (GX Works 3)** 831 831 832 832 Find the [Ethernet port] in the navigation area. 833 833 834 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8e8f85ace087346c.png?width=300&height=593&rev=1.1||alt="12.PLC Protocol_html_8e8f85ace087346c.png" height="593" width="300"]] 833 +(% style="text-align:center" %) 834 +[[image:12.PLC Protocol_html_8e8f85ace087346c.png||data-xwiki-image-style-alignment="center" height="593" width="300" class="img-thumbnail"]] 835 835 836 836 Select [Own Node Settings] in the [Setting Item List]; 837 837 ... ... @@ -839,7 +839,8 @@ 839 839 840 840 Click [Detailed Settings] into [Ethernet Configuration (Built-in Ethernet Port)] windows; 841 841 842 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5d98495052c8c10e.png?width=600&height=339&rev=1.1||alt="12.PLC Protocol_html_5d98495052c8c10e.png" height="339" width="600"]] 842 +(% style="text-align:center" %) 843 +[[image:12.PLC Protocol_html_5d98495052c8c10e.png||data-xwiki-image-style-alignment="center" height="339" width="600" class="img-thumbnail"]] 843 843 844 844 Select [SLMP Connection Module] and add into host station as below picture shows; 845 845 ... ... @@ -847,263 +847,66 @@ 847 847 848 848 Click [Close with Reflecting the Setting] to save and close window; 849 849 850 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_14b489fdc6c6589d.png?width=600&height=350&rev=1.1||alt="12.PLC Protocol_html_14b489fdc6c6589d.png" height="350" width="600"]] 851 +(% style="text-align:center" %) 852 +[[image:12.PLC Protocol_html_14b489fdc6c6589d.png||data-xwiki-image-style-alignment="center" height="350" width="600" class="img-thumbnail"]] 851 851 852 852 Click [Apply] to completed Etherenet settings; 853 853 854 854 Switch to the [On line data operation] interface as below, check the item and click [Execute] to download. 855 855 856 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_c93025a968a8a9e7.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_c93025a968a8a9e7.png" height="434" width="600"]] 858 +(% style="text-align:center" %) 859 +[[image:12.PLC Protocol_html_c93025a968a8a9e7.png||data-xwiki-image-style-alignment="center" height="434" width="600" class="img-thumbnail"]] 857 857 858 -**4)Configure the communication protocol** 859 - 860 -[[image:image-20220825112403-1.png||alt="图片-20220825112403-1.png"]] 861 - 862 -**5)电缆布线** 863 - 864 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 865 - 866 - 867 -== **L02 Serial Protocol** == 868 - 869 -Mitsubishi L02 series CPU built-in Ethernet port. 870 - 871 -**V-BOX Settings** 872 - 873 -|**Items**|**Settings**|**Note** 874 -|Protocol|MIT L02 CPU MELSEC| 875 -|Connection|Ethernet| 876 -|Port No.|1025|Must be the same as the PLC setting 877 -|PLC station No.|0|Must be the same as the PLC setting 878 - 879 -**Address List** 880 - 881 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 882 -|Bit|X|X|X h|0~~FFFF| 883 -|Bit|Y|Y|Y h|0~~FFFF| 884 -|Bit|M|M|M d|0~~9999| 885 -|Bit|L|L|L d|0~~9999| 886 -|Bit|F|F|F d|0~~9999| 887 -|Bit|B|B|B h|0~~FFFF| 888 -|Bit|V|V|V d|0~~2047| 889 -|Bit|TC|TC|TC d|0~~9999| 890 -|Bit|SS|SS|SS d|0~~9999| 891 -|Bit|SC|SC|SC d|0~~9999| 892 -|Bit|CS|CS|CS d|0~~9999| 893 -|Bit|CC|CC|CC d|0~~9999| 894 -|Bit|SB|SB|SB h|0~~FFFF| 895 -|Bit|SM|SM|SM d|0~~2047| 896 -|Bit|STS|STS|STS d|0~~1023| 897 -|Bit|S|S|S d|0~~9999| 898 -|Bit|DX|DX|DX h|0~~FFFF| 899 -|Bit|DY|DY|DY h|0~~FFFF| 900 -|Bit|TS|TS|TS d|0~~9999| 901 -|Bit|Dbit|Dbit|Dbit d.d|0~~99999.0~~15| 902 -|Word|W|W|W h|0~~FFFF| 903 -|Word|TN|TN|TN d|0~~99999| 904 -|Word|SN|SN|SN d|0~~99999| 905 -|Word|CN|CN|CN d|0~~99999| 906 -|Word|R|R|R d|0~~99999| 907 -|Word|SW|SW|SW h|0~~FFFF| 908 -|Word|Z|Z|Z d|0~~99999| 909 -|Word|ZR|ZR|ZR h|0~~FFFF| 910 -|Word|D|D|D d|0~~99999| 911 - 912 -**Communication Settings** 913 - 914 - 915 915 **Cable Wiring** 916 916 863 +(% style="text-align:center" %) 864 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 917 917 866 += **Delta PLC** = 918 918 868 +== **DVP Ethernet Protocol** == 919 919 920 - ==**L02Protocol** ==870 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]] 921 921 922 - MitsubishiLseries CPU built-inEthernet port.872 +== **DVP Serial Protocol** == 923 923 924 - **1)V-BOXSettings**874 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]] 925 925 926 -|**Items**|**Settings**|**Note** 927 -|Protocol|MIT L02 CPU MELSEC| 928 -|Connection|Ethernet| 929 -|Port No.|1025|Must be the same as the PLC setting 930 -|PLC station No.|0|Must be the same as the PLC setting 876 += **Omron PLC** = 931 931 932 -** 2)AddressList**878 +== **CP1 Series Protocol** == 933 933 934 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 935 -|Bit|X|X|X h|0~~FFFF| 936 -|Bit|Y|Y|Y h|0~~FFFF| 937 -|Bit|M|M|M d|0~~9999| 938 -|Bit|L|L|L d|0~~9999| 939 -|Bit|F|F|F d|0~~9999| 940 -|Bit|B|B|B h|0~~FFFF| 941 -|Bit|V|V|V d|0~~2047| 942 -|Bit|TC|TC|TC d|0~~9999| 943 -|Bit|SS|SS|SS d|0~~9999| 944 -|Bit|SC|SC|SC d|0~~9999| 945 -|Bit|CS|CS|CS d|0~~9999| 946 -|Bit|CC|CC|CC d|0~~9999| 947 -|Bit|SB|SB|SB h|0~~FFFF| 948 -|Bit|SM|SM|SM d|0~~2047| 949 -|Bit|STS|STS|STS d|0~~1023| 950 -|Bit|S|S|S d|0~~9999| 951 -|Bit|DX|DX|DX h|0~~FFFF| 952 -|Bit|DY|DY|DY h|0~~FFFF| 953 -|Bit|TS|TS|TS d|0~~9999| 954 -|Bit|Dbit|Dbit|Dbit d.d|0~~99999.0~~15| 955 -|Word|W|W|W h|0~~FFFF| 956 -|Word|TN|TN|TN d|0~~99999| 957 -|Word|SN|SN|SN d|0~~99999| 958 -|Word|CN|CN|CN d|0~~99999| 959 -|Word|R|R|R d|0~~99999| 960 -|Word|SW|SW|SW h|0~~FFFF| 961 -|Word|Z|Z|Z d|0~~99999| 962 -|Word|ZR|ZR|ZR h|0~~FFFF| 963 -|Word|D|D|D d|0~~99999| 880 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]] 964 964 965 -** 3)PLC Settings(GX Works2 )**882 +== **CJ2M Series Protocol** == 966 966 967 - Createaproject884 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]] 968 968 969 -Set PLC IP, subnet mask and gateway; 970 - 971 -Select [Binary Code] as communication data code; 972 - 973 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_776e17505f3fc6c0.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_776e17505f3fc6c0.png" height="524" width="600"]] 974 - 975 -Set PLC port number, for example 1025 976 - 977 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8d0d1a22d388f70b.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_8d0d1a22d388f70b.png" height="524" width="600"]] 978 - 979 -Save settings; 980 - 981 -Download project into PLC device; 982 - 983 -Restart PLC device; 984 - 985 -**4)Configure the communication protocol** 986 - 987 -[[image:image-20220825142659-1.png]] 988 - 989 -**5)Cable Wiring** 990 - 991 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 992 - 993 -== **QJ71E71 Ethernet Protocol** == 994 - 995 -Mitsubishi QJ71E71 Ethernet communication module; 996 - 997 -**1)V-BOX Settings** 998 - 999 -|**Items**|**Settings**|**Note** 1000 -|Protocol|MIT QJ71E71 MELSEC| 1001 -|Connection|Ethernet| 1002 -|Port No.|1025|Must be the same as the PLC setting 1003 -|PLC station No.|0|Must be the same as the PLC setting 1004 - 1005 -**2)Address List** 1006 - 1007 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 1008 -|(% rowspan="18" %)Bit|X|X|X h|0~~1FFF| 1009 -|Y|Y|Y h|0~~1FFF| 1010 -|M|M|M d|0~~99999| 1011 -|L|L|L d|0~~8191| 1012 -|F|F|F d|0~~2047| 1013 -|B|B|B h|0~~1FFF| 1014 -|V|V|V d|0~~2047| 1015 -|TS|TS|TS d|0~~2047| 1016 -|TC|TC|TC d|0~~2047| 1017 -|SS|SS|SS d|0~~2047| 1018 -|SC|SC|SC d|0~~2047| 1019 -|CS|CS|CS d|0~~1023| 1020 -|CC|CC|CC d|0~~1023| 1021 -|SB|SB|SB h|0~~7FF| 1022 -|S|S|S d|0~~8191| 1023 -|DX|DX|DX h|0~~1FFF| 1024 -|DY|DY|DY h|0~~1FFF| 1025 -|SM|SM|SM d|8000~~9999| 1026 -|(% rowspan="10" %)Word|SD|SD|SD d|0~~2047| 1027 -|D|D|D d|0~~12287| 1028 -|W|W|W h|0~~1FFF| 1029 -|TN|TN|TN d|0~~2047| 1030 -|SN|SN|SN d|0~~2047| 1031 -|CN|CN|CN d|0~~1023| 1032 -|R|R|R d|0~~32767| 1033 -|SW|SW|SW h|0~~7FF| 1034 -|Z|Z|Z d|0~~15| 1035 -|ZR|ZR|ZR h|0~~FE7FF| 1036 - 1037 -**3)PLC Settings(GX Works2)** 1038 - 1039 -* Click [Ethernet/CC IE/MELSECNET]; 1040 -* Please select [Ethernet] as network type; 1041 -* Set station I/O number according to situation (For example, 0000 means that the module is connected to PLC CPU in first order); 1042 -* Select [Online] as Mode; 1043 -* Click [Operation setting] to set IP; 1044 -* Select [Binary Code] as [Communication Data Code]; 1045 -* Set protocol: TCP; 1046 -* Set [unpassive] in [Open system]; 1047 -* Set [receive] in [Fixed buffer]; 1048 -* Set [procedure Exist] in [Fixed buffer communication]; 1049 -* Disable [Pairing open]; 1050 -* Set [No confirm] in [Existence confirmation]; 1051 -* Host station port number: 1025; 1052 -* Save settings; 1053 -* Download project into PLC and restart it 1054 - 1055 -**4)Configure the communication protocol** 1056 - 1057 -[[image:image-20220825143728-1.png]] 1058 - 1059 -**5)Cable Wiring** 1060 - 1061 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png"]] 1062 - 1063 -== **Delta PLC 1064 -DVP Ethernet Protocol** == 1065 - 1066 -[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]] 1067 - 1068 -== **DVP 串行协议** == 1069 - 1070 -[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]] 1071 - 1072 -= **欧姆龙可编程逻辑控制器** = 1073 - 1074 -== **CP1 系列协议** == 1075 - 1076 -[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]] 1077 - 1078 -== **CJ2M 系列协议** == 1079 - 1080 -[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]] 1081 - 1082 1082 = **Modbus RTU** = 1083 1083 1084 -== **V-BOX 作为主** ==888 +== **V-BOX as master** == 1085 1085 1086 - 选择协议“(%_istranslated="1"class="mark" %)Modbus RTU Slave(All Fuction)”,890 +Select the protocol “(% class="mark" %)Modbus RTU Slave(All Fuction)”, 1087 1087 1088 -(% class="mark" %) 然后设置波特率,端口,停止位,数据位,奇偶校验892 +(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity 1089 1089 1090 1090 (% style="text-align:center" %) 1091 1091 [[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]] 1092 1092 1093 -== **V-BOX 作为从站** ==897 +== **V-BOX as slave** == 1094 1094 1095 - 选择协议“(%_istranslated="1"class="mark" %)**Modbus RTU Master”**,899 +Select the protocol “(% class="mark" %)**Modbus RTU Master”**, 1096 1096 1097 -(% class="mark" %) 然后设置波特率,端口,停止位,数据位,奇偶校验901 +(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity 1098 1098 1099 1099 (% style="text-align:center" %) 1100 1100 [[image:1624348709622-711.png||queryString="width=809&height=493" height="488" width="800" class="img-thumbnail"]] 1101 1101 1102 -** 地址列表**906 +**Address List** 1103 1103 1104 1104 (% class="table-bordered" %) 1105 -|** 类型**|**注册**|**函数代码和描述**1106 -|(% rowspan="11" %) 词|(% rowspan="3" %)3|04(读取输入寄存器:读取一个或多个输入寄存器中的当前二进制值)909 +|**Type**|**Register**|**Function code & Description** 910 +|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers) 1107 1107 |06 (write single register: write a binary value to a holding register) 1108 1108 |10 (write values to multiple addresses ) 1109 1109 |(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers)
- image-20220825112403-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -128.1 KB - Content
- image-20220825142437-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -126.5 KB - Content
- image-20220825142659-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -124.2 KB - Content
- image-20220825143728-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -124.7 KB - Content