Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 14 added, 0 removed)
- image-20220825160227-1.png
- image-20220825160341-2.png
- image-20220825160648-3.png
- image-20220825160820-4.png
- image-20220825160925-5.png
- image-20220825160929-6.png
- image-20220825161440-7.png
- image-20220825161612-8.png
- image-20220831155101-1.png
- image-20220831155129-2.png
- image-20220831155157-3.png
- image-20220831160010-4.png
- image-20220831160055-5.png
- image-20220831161041-1.png
Details
- Page properties
-
- Content
-
... ... @@ -1,4 +1,4 @@ 1 -= (% style="color:inherit; font-family:inherit"%)**WeconPLC**(%%)=1 += Create communication with WECON PLC = 2 2 3 3 == **LX3V Serial Protocol** == 4 4 ... ... @@ -176,7 +176,7 @@ 176 176 177 177 The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC. 178 178 179 -= **Rockwell PLC** = 179 += Create communication with **Rockwell PLC** = 180 180 181 181 == (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** == 182 182 ... ... @@ -217,7 +217,7 @@ 217 217 218 218 [[image:image-20220824110724-1.png]] 219 219 220 -== **Micro850_FreeTag** == 220 +== **Micro850_FreeTag Protocol** == 221 221 222 222 ((( 223 223 ((( ... ... @@ -425,7 +425,7 @@ 425 425 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]] 426 426 427 427 428 -= **Siemens PLC** = 428 += Create communication with **Siemens PLC** = 429 429 430 430 == **S7-200 Smart Ethernet Protocol** == 431 431 ... ... @@ -608,9 +608,8 @@ 608 608 609 609 [[image:image-20220824162342-2.png]] 610 610 611 += Create communication with **Mitsubishi PLC** = 611 611 612 -= **Mitsubishi PLC** = 613 - 614 614 == **FX1S,1N,2N Serial Protocol** == 615 615 616 616 Supported Series: Mitsubishi FX1S, FX1N, FX2N series ... ... @@ -866,17 +866,20 @@ 866 866 867 867 == **L02 Serial Protocol** == 868 868 869 -Mitsubishi L02 series CPU built-in Ethernetport.868 +Mitsubishi L02 series CPU built-in serial port. 870 870 871 -**V-BOX Settings** 870 +**1)V-BOX Settings** 872 872 873 -|**Items**|**Settings**|**Note** 874 -|Protocol|MIT L02 CPU MELSEC| 875 -|Connection|Ethernet| 876 -|Port No.|1025|Must be the same as the PLC setting 877 -|PLC station No.|0|Must be the same as the PLC setting 872 +|**Item**|**Settings**|**Note** 873 +|Protocol|Mitsubishi L02| 874 +|Connection|RS422| 875 +|Baud rate|115200| 876 +|Data bit|8| 877 +|Parity|Odd| 878 +|Stop bit|1| 879 +|PLC station No.|1~~255|Need to be the same as PLC settings 878 878 879 -**Address List** 881 +**2)Address List** 880 880 881 881 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 882 882 |Bit|X|X|X h|0~~FFFF| ... ... @@ -909,13 +909,17 @@ 909 909 |Word|ZR|ZR|ZR h|0~~FFFF| 910 910 |Word|D|D|D d|0~~99999| 911 911 912 -**Communication Settings** 914 +**3)Communication Settings** 913 913 916 +[[image:image-20220825160648-3.png]] 914 914 915 -**Cable Wiring** 918 +**4)Cable Wiring** 916 916 920 +* **RS422** 917 917 922 +[[image:image-20220825161612-8.png]] 918 918 924 +[[image:image-20220825160820-4.png]] 919 919 920 920 == **L02 Ethernet Protocol** == 921 921 ... ... @@ -1060,9 +1060,10 @@ 1060 1060 1061 1061 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png"]] 1062 1062 1063 -== **Delta PLC 1064 -DVP Ethernet Protocol** == 1069 += Create communication with **Delta PLC** = 1065 1065 1071 +== **DVP Ethernet Protocol** == 1072 + 1066 1066 [[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]] 1067 1067 1068 1068 == **DVP serial protocol** == ... ... @@ -1069,41 +1069,149 @@ 1069 1069 1070 1070 [[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]] 1071 1071 1072 -= ** 欧姆龙可编程逻辑控制器** =1079 +== **AS Ethernet Protocol** == 1073 1073 1074 - ==**CP1系列协议**==1081 +**1)V-BOX Settings** 1075 1075 1083 +|=**Items**|=**Settings**|=**Note** 1084 +|Protocol|DELTA AS300 MODBUS TCP| 1085 +|Connection|Ethernet| 1086 +|Port No.|502| 1087 +|Device No.|1| 1088 +|HMI No.|0| 1089 + 1090 +**2)Address List** 1091 + 1092 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 1093 +|Bit|X|X|X d|0~~63| 1094 +|Bit|Y|Y|Y d|0~~63| 1095 +|Bit|D|D|D d|0~~29999| 1096 +|Bit|M|M|M d|0~~8191| 1097 +|Bit|SM|SM|SM d|0~~4095| 1098 +|Bit|S|S|S h|0~~2047| 1099 +|Bit|T|T|T d|0~~511| 1100 +|Bit|C|C|C d|0~~511| 1101 +|Bit|HC|HC|HC d|0~~255| 1102 +|Word|X|X|X h|0~~63| 1103 +|Word|Y|Y|Y d|0~~63| 1104 +|Word|SR|SR|SR d|0~~2047| 1105 +|Word|D|D|D d|0~~29999| 1106 +|Word|T|T|T d|0~~511| 1107 +|Word|C|C|C h|0~~511| 1108 +|Word|E|E|E d|0~~9| 1109 + 1110 +**3)Configure the communication protocol** 1111 + 1112 + 1113 +[[image:image-20220831160010-4.png]] 1114 + 1115 +**4)Cable Wiring** 1116 + 1117 +Figure 1118 + 1119 +[[image:image-20220831155101-1.png]][[image:image-20220831160055-5.png]] 1120 + 1121 +Pin Definition Diagram 1122 + 1123 +[[image:image-20220831155157-3.png]] 1124 + 1125 += Create communication with **Omron PLC** = 1126 + 1127 +== **CP1 Series Protocol ** == 1128 + 1076 1076 [[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]] 1077 1077 1078 -== **C J2M系列协议** ==1131 +== **CP2M Series Protocol** == 1079 1079 1080 1080 [[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]] 1081 1081 1082 -= **Modbus RTU** = 1083 1083 1084 -== ** V-BOX作为主** ==1136 +== **EC55 Protocol** == 1085 1085 1086 - 选择协议“(% _istranslated="1"class="mark"%)ModbusRTU Slave(AllFuction)”,1138 +Supported device: EC55 temperature instrument 1087 1087 1088 - (%class="mark" %)然后设置波特率,端口,停止位,数据位,奇偶校验1140 +**1)V-BOX Settings** 1089 1089 1142 +|**Items**|**Settings**|**Note** 1143 +|Protocol|Omron EC55| 1144 +|Connection|RS485 (9600, 2, 7, EVEN)| 1145 +|Port No.|None| 1146 +|PLC station No.|0| 1147 + 1148 +**2)Address List** 1149 + 1150 +|**Type**|**Register**|**Device range**|**HMI range**|**Function** 1151 +|(% rowspan="3" %)Double word|C0|0-13 (Hex)|0-19|Set read only parameter for area 0 1152 +|C1|0-4D(Hex)|0-77|Set Read/Write parameter for area 0 1153 +|C3|0-CD(Hex)|0-205|Set Read/Write parameter for area 1 1154 +|(% rowspan="6" %)Word|80|0-13(Hex)|0-19|Set read only parameter in area 0 1155 +|81|0-4D(Hex)|0-77|Set Read/Write parameter in area 0 1156 +|83|0-CD(Hex)|0-205|Set Read/Write parameter in area 1 1157 +|CP|-|0-6|Read controller intrinsic property 1158 +|CS|-|0-2|Read controller states 1159 +|CA|-|0-17|Action command 1160 + 1161 +**3)Device Settings** 1162 + 1163 +Omron E5CC PLC configuration 1164 + 1165 +After entering the Communication Settings menu, please set the parameters to the default values for the following table. Press the cycle key of the instrument to enter the next setting. 1166 + 1167 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_3d95e093792ba98a.png?width=550&height=229&rev=1.1||alt="12.PLC Protocol_html_3d95e093792ba98a.png" height="229" width="550"]] 1168 + 1169 +According to PLC configuration and communication port configuration information of the HMI, provide the corresponding steps and configuration screenshots. This configuration needs to communicate properly with the above PLC configuration. The project settings are as follows 1170 + 1171 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_be583aa69dd6cf4c.png?width=550&height=242&rev=1.1||alt="12.PLC Protocol_html_be583aa69dd6cf4c.png" height="242" width="550"]] 1172 + 1173 +**✎Note:** The communication settings for HMI should be consistent with this setting. 1174 + 1175 +**4)Configure the communication protocol** 1176 + 1177 +[[image:image-20220831161041-1.png]] 1178 + 1179 +**5)Cable Wiring** 1180 + 1181 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5e9a81a14106da9e.png?width=392&height=223&rev=1.1||alt="12.PLC Protocol_html_5e9a81a14106da9e.png" height="223" width="392"]] 1182 + 1183 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_1897d92be6948d58.png?width=393&height=223&rev=1.1||alt="12.PLC Protocol_html_1897d92be6948d58.png" height="223" width="393"]] 1184 + 1185 +**✎Note:** 1186 + 1187 +* COM3 only available in PI8000/PI9000 series. 1188 +* CA address could not support continuous writing function; 1189 +* Because of CP address intrinsic property: read control intrinsic property, so please place the character input part in use. Set address with CP0 and character length 10, used to display controller type. And place a number input part, set address with CP5 (cache size). Do not place other CP type address without CP0 in screen, otherwise CP type address is invalid 1190 +* When set value into read & write address, it is necessary to switch the temperature instrument meter to the corresponding interface according to the menu of the instrument where the address locates, so that the value could be written, otherwise, the value could not be written; When the communication write setting of the instrument is turned off, the writing function is invalid. Writing function could be opened by using the 00 address of the CA register, which write 01 value. 1191 +* When continuous writing of a value to a read-write address, please make sure all continuous writing address could be written. Otherwise, if one of these addresses could not be written, then all continuous writing commands will fail. 1192 +* Because of the mechanism problem, this protocol could not support CompoWay/F function that is read-write function of variables in protocol document. 1193 +* When using double-word address, set the data format to 32 bits, otherwise the read/write function is unable. 1194 +* Please set the communication delay time of 10ms in setting, to avoid that the instrument may not be able to communicate in a short time due to too fast data access and too much connection requests. 1195 +* [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_d428cad280fdefb3.png?width=347&height=276&rev=1.1||alt="12.PLC Protocol_html_d428cad280fdefb3.png" height="276" width="347"]]Because of the particularity of the instrument, it is necessary to write the value of the address in the menu interface corresponding to the address, and to enter the menu where the address locates, so that the value could be written. 1196 + 1197 += Create communication with **Modbus RTU** = 1198 + 1199 +== **V-BOX as Slave** == 1200 + 1201 +Select the protocol "Modbus RTU Slave (All Fuction)", 1202 + 1203 +Then set baud rate, port, stop bits, data bits, parity. 1204 + 1090 1090 (% style="text-align:center" %) 1091 1091 [[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]] 1092 1092 1093 -== **V-BOX 作为从站** ==1208 +== **V-BOX as Master** == 1094 1094 1095 - 选择协议“(% _istranslated="1"class="mark"%)**Modbus RTU Master”**,1210 +Select the protocol "Modbus RTU Master", 1096 1096 1097 - (%class="mark"%)然后设置波特率,端口,停止位,数据位,奇偶校验1212 +Then set baud rate, port, stop bits, data bits, parity 1098 1098 1099 1099 (% style="text-align:center" %) 1100 1100 [[image:1624348709622-711.png||queryString="width=809&height=493" height="488" width="800" class="img-thumbnail"]] 1101 1101 1102 -** 地址列表**1217 +**address list** 1103 1103 1104 1104 (% class="table-bordered" %) 1105 -|** 类型**|**注册**|**函数代码和描述**1106 -|(% rowspan="11" %)词|(% rowspan="3" %)3|04 (读取输入寄存器:读取一个或多个输入寄存器中的当前二进制值)1220 +|**type**|**register**|**Function code and description** 1221 +|(% rowspan="11" %)词|(% rowspan="3" %)3|04 (Read Input Registers: Read the current binary value in one or more input registers) 1107 1107 |06 (write single register: write a binary value to a holding register) 1108 1108 |10 (write values to multiple addresses ) 1109 1109 |(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers)
- image-20220825160227-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +148.8 KB - Content
- image-20220825160341-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +121.7 KB - Content
- image-20220825160648-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +122.7 KB - Content
- image-20220825160820-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +24.9 KB - Content
- image-20220825160925-5.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +31.0 KB - Content
- image-20220825160929-6.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +31.0 KB - Content
- image-20220825161440-7.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +90.7 KB - Content
- image-20220825161612-8.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +86.3 KB - Content
- image-20220831155101-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +34.6 KB - Content
- image-20220831155129-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +44.9 KB - Content
- image-20220831155157-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +20.8 KB - Content
- image-20220831160010-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +59.6 KB - Content
- image-20220831160055-5.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +51.5 KB - Content
- image-20220831161041-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +58.1 KB - Content