... ... @@ -58,37 +58,41 @@
58 58  (% style="text-align:center" %)
59 59  [[image:1624348978863-771.png||queryString="width=812&height=494" height="487" width="800" class="img-thumbnail"]]
60 60  
61 +(% class="wikigeneratedid" %)
62 +== ==
63 +
61 61  == **2 Communication with Allen-Bradley CompactLogix L1769** ==
62 62  
63 -=== **Overview** ===
64 -
65 65  (((
66 66  This example introduces the establishment of Ethernet communication between Wecon V-box and Allen-Bradley L1769. It is introduced through three parts: PLC software configuration, V-box software configuration, and hardware wiring.
68 +
69 +
67 67  )))
68 68  
69 69  (((
70 -
73 +(% class="wikigeneratedid" id="HSoftwareconfigurationofPLC" %)
74 +(((
75 +**Software configuration of PLC**
71 71  )))
72 72  
78 +(% class="wikigeneratedid" id="HPLCprogrammingsoftware" %)
73 73  (((
74 -== **Software configuration of PLC** ==
80 +**1)PLC programming software**
81 +)))
75 75  
76 -=== **PLC programming software** ===
83 +[[image:image-20220714113935-3.png||height="324" width="270"]]
77 77  
78 - [[image:image-20220714113935-3.png]]
79 -
80 -=== **New PLC project** ===
81 -
85 +(% class="wikigeneratedid" id="HNewPLCproject" %)
82 82  (((
83 -Click New Project and select the PLC model.
87 +**2)New PLC project**
84 84  )))
85 85  
86 86  (((
87 - [[image:image-20220714114247-4.png]]
91 +Click New Project and select the PLC model.
88 88  )))
89 89  
90 90  (((
91 - [[image:image-20220714114257-5.png]]
95 +[[image:image-20220714114247-4.png||height="298" width="552"]] [[image:image-20220714114257-5.png||height="445" width="551"]]
92 92  )))
93 93  
94 94  (((
... ... @@ -96,26 +96,37 @@
96 96  )))
97 97  
98 98  (((
99 -=== **Set Ethernet parameters** ===
103 +(% class="wikigeneratedid" id="HSetEthernetparameters" %)
104 +(((
105 +**3)Set Ethernet parameters**
106 +)))
100 100  
101 101  (((
109 +(((
102 102  Follow the steps below to configure Ethernet parameters
103 103  )))
112 +)))
104 104  
105 105  (((
115 +(((
106 106  PLC IP address:192.168.40.101
107 107  )))
118 +)))
108 108  
109 109  (((
121 +(((
110 110  default gateway:192.168.40.1
111 111  )))
124 +)))
112 112  
113 113  (((
127 +(((
114 114  subnet mask:255.255.255.0
115 115  )))
130 +)))
116 116  
117 117  (((
118 - [[image:image-20220714115012-6.png]]
133 +[[image:image-20220714115012-6.png]]
119 119  )))
120 120  
121 121  (((
... ... @@ -123,36 +123,48 @@
123 123  )))
124 124  
125 125  (((
126 -== **V-box software configuration** ==
141 +(% class="wikigeneratedid" id="HV-boxsoftwareconfiguration" %)
142 +(((
143 +**V-box software configuration**
144 +)))
127 127  
128 -=== **V-box programming software** ===
146 +(% class="wikigeneratedid" id="HV-boxprogrammingsoftware" %)
147 +(((
148 +**1)V-box programming software**
149 +)))
129 129  
130 - [[image:image-20220714115214-7.png]]
151 +(% class="wikigeneratedid" %)
152 +(((
153 + [[image:image-20220714115214-7.png||height="276" width="456"]]
154 +)))
131 131  
156 +(% class="wikigeneratedid" id="HConfiguredevicenetwork" %)
157 +(((
158 +**2)Configure device network**
159 +)))
132 132  
133 -=== **Configure device network** ===
134 -
135 135  (((
162 +(((
136 136  Click the Configuration Download button[[image:image-20220714115308-8.png||height="22" width="15"]], It is used to configure the device network, update the device time, obtain the device machine code, check the device network, etc.
137 137  )))
165 +)))
138 138  
139 139  (((
140 -In the example below, the IP address of V-Box is configured as 192.168.40.66, and the networking method is 4G connection.
168 +(((
169 +In the example below, the IP address of V-Box is configured as 192.168.40.66, and the networking method is 4G connection [[image:image-20220714115440-9.png||height="425" width="791"]]
141 141  )))
142 -
143 - [[image:image-20220714115440-9.png||height="425" width="791"]]
144 144  )))
145 145  )))
146 -
147 -== **V-net add device** ==
148 148  )))
149 149  
175 +(% class="wikigeneratedid" id="HV-netadddevice" %)
150 150  (((
151 -Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device. 
177 +**3)V-net add device**
152 152  )))
179 +)))
153 153  
154 154  (((
155 - [[image:image-20220714115640-10.png||height="430" width="797"]]
182 +Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device.   [[image:image-20220714115640-10.png||height="430" width="797"]]
156 156  )))
157 157  
158 158  (((
... ... @@ -160,18 +160,26 @@
160 160  )))
161 161  
162 162  (((
163 -=== **Set communication port parameters** ===
190 +(% class="wikigeneratedid" id="HSetcommunicationportparameters" %)
191 +(((
192 +**4)Set communication port parameters**
193 +)))
164 164  
165 -In the device list on the left, find the Vbox that communicates with the L1769, click it and select configuration,communication port configuration in the main interface to add a communication protocol.
166 -
167 - [[image:image-20220714115848-11.png||height="432" width="802"]]
195 +In the device list on the left, find the Vbox that communicates with the L1769, click it and select configuration,communication port configuration in the main interface to add a communication protocol. [[image:image-20220714115848-11.png||height="432" width="802"]]
168 168  )))
169 169  
170 -
171 171  The communication port is selected as Ethernet, the device type is selected as Allen-Bradley, the protocol is Allen-BradleyMicro850_FreeTag EthemetIP, and the IP is the internal IP address of the L1769 PLC. The port number is 44818.
172 172  
200 +[[image:image-20220714143820-1.png]]
173 173  
202 +After adding the protocol Allen-BradleyMicro850_FreeTag, click[[image:image-20220714143838-2.png]]icon add label.
174 174  
204 +[[image:image-20220714143849-3.png]]
205 +
206 +
207 +== Engineering production ==
208 +
209 +
175 175  == **Siemens S7-1200** ==
176 176  
177 177  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]]
image-20220714143820-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +1.4 MB
Content
image-20220714143838-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +520 bytes
Content
image-20220714143849-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +1.3 MB
Content