Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 53 added, 0 removed)
- image-20220714143820-1.png
- image-20220714143838-2.png
- image-20220714143849-3.png
- image-20220714160006-1.png
- image-20220714160034-2.png
- image-20220714160120-3.png
- image-20220714160335-4.png
- image-20220714160412-5.png
- image-20220714160439-6.png
- image-20220714160541-7.png
- image-20220714160651-8.png
- image-20220714160843-9.png
- image-20220714160943-10.png
- image-20220714161014-11.png
- image-20220714161120-12.png
- image-20220714161229-13.png
- image-20220714161445-14.png
- image-20220714162600-1.png
- image-20220714162617-2.png
- image-20220714162629-3.png
- image-20220714162652-4.png
- image-20220714162713-5.png
- image-20220714162725-6.png
- image-20220714162737-7.png
- image-20220714162752-8.png
- image-20220714162805-9.png
- image-20220714162814-10.png
- image-20220714162827-11.png
- image-20220714162841-12.png
- image-20220714162856-13.png
- image-20220820164423-1.png
- image-20220822172124-1.png
- image-20220822172228-2.png
- image-20220822172553-1.png
- image-20220822172623-2.png
- image-20220822172657-3.png
- image-20220822172730-4.png
- image-20220824104124-1.png
- image-20220824104909-2.png
- image-20220824110724-1.png
- image-20220824120406-1.png
- image-20220824120507-2.png
- image-20220824120524-3.png
- image-20220824120547-4.png
- image-20220824120614-5.png
- image-20220824142130-1.png
- image-20220824142546-2.png
- image-20220824142643-3.png
- image-20220824142722-1.png
- image-20220824143613-1.png
- image-20220824143744-2.png
- image-20220824144619-1.png
- image-20220824151127-2.png
Details
- Page properties
-
- Content
-
... ... @@ -1,121 +1,300 @@ 1 -= **1GeneralcommunicationwithPLC** =1 += (% style="color:inherit; font-family:inherit" %)**WECON PLC**(%%) = 2 2 3 -== ** ModbusRTU** ==3 +== **LX3V Serial Protocol** == 4 4 5 - ===**V-BOX asmaster**===5 +Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM 6 6 7 - Select the protocol “(% class="mark" %)ModbusRTUSlave(All Fuction)”,7 +**HMI Settings** 8 8 9 -(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity 9 +|**Item**|**Settings**|**Note** 10 +|Protocol|WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM| 11 +|Connection|RS422/RS485| 12 +|Baud rate|9600| 13 +|Data bit|7| 14 +|Parity|EVEN| 15 +|Stop bit|1| 16 +|PLC station No.|1| 10 10 11 -(% style="text-align:center" %) 12 -[[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]] 18 +**Address List** 13 13 14 -=== **V-BOX as slave** === 20 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 21 +|(% rowspan="6" %)Bit|X|X|Xo|0~~303237| 22 +|Y|Y|Y o|0~~303237| 23 +|M|M|M d|0~~99999| 24 +|T|T|T d|0~~99999| 25 +|C|C|C d|0~~99999| 26 +|S|S|S d|0~~99999| 27 +|(% rowspan="8" %)Word|X|X|Xo|0~~303237| 28 +|Y|Y|Y o|0~~303237| 29 +|M|M|M d|0~~99999| 30 +|T|T|T d|0~~99999| 31 +|C|C|C d|0~~199| 32 +|D|D|D d|0~~7999| 33 +|S|S|S d|0~~99999| 34 +|SD|SD|SD d|8000~~9999| 15 15 16 - Select the protocol “(% class="mark" %)**Modbus RTU Master”**,36 +**Cable Wiring** 17 17 18 - (%class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity38 +* **RS422** 19 19 20 -(% style="text-align:center" %) 21 -[[image:1624348709622-711.png||queryString="width=809&height=493" height="488" width="800" class="img-thumbnail"]] 40 + [[image:image-20220824120614-5.png]] 22 22 23 -* *AddressList**42 +* **RS485** 24 24 25 -(% class="table-bordered" %) 26 -|**Type**|**Register**|**Function code & Description** 27 -|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers) 28 -|06 (write single register: write a binary value to a holding register) 29 -|10 (write values to multiple addresses ) 30 -|(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers) 31 -|06 (write single register: write a binary value to a holding register) 32 -|10 (write values to multiple addresses ) 33 -|(% rowspan="3" %)W6|03 (read holding register: read current binary value in one or more holding registers) 34 -|06 (write single register: write a binary value to a holding register) 35 -|10 (write values to multiple addresses ) 36 -|(% rowspan="2" %)W16|03 (read holding register: read current binary value in one or more holding registers) 37 -|10 (write values to multiple addresses ) 38 -|(% rowspan="11" %)Bit|(% rowspan="3" %)0|01 (Read coil state) 39 -|05 (Force a single coil to force the on/off state of a logic coil) 40 -|0F (Write multiple bits, ie write continuously) 41 -|(% rowspan="3" %)1|02 (Read the input state) 42 -|05 (Force a single coil to force the on/off state of a logic coil) 43 -|0F (Write multiple bits) 44 -|(% rowspan="3" %)W5|01 (Read coil state to obtain the current state of a set of logic coils) 45 -|05 (Force a single coil to force the on/off state of a logic coil) 46 -|0F (Write multiple bits) 47 -|(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils) 48 -|0F (Write multiple bits) 44 + [[image:image-20220824120524-3.png]] 49 49 50 -== ** WECONLX3V PLC** ==46 +== **LX5V Serial Protocol** == 51 51 52 - Select the protocol(%class="mark"%)"WECONLX3V"48 +This example introduces the establishment of serial port communication between Wecon V-BOX and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 53 53 54 - (% class="mark" %)thenset BaudRate,Port,Stop Bit,Data Bit,ParitysamewithPLC.50 +**Software configuration of PLC** 55 55 56 - (% class="mark" %)WECONPLCRS422port,default communicationparameters is 9600,1,7,ZEVEN52 +**1)PLC programming software** 57 57 58 -(% style="text-align:center" %) 59 -[[image:1624348978863-771.png||queryString="width=812&height=494" height="487" width="800" class="img-thumbnail"]] 54 +[[image:image-20220824142722-1.png]] 60 60 61 - ==**2 Communicationwith Allen-Bradley CompactLogix L1769**==56 +**2)New PLC project** 62 62 63 - ===**Overview**===58 +Click New Project and select the PLC model. 64 64 60 +[[image:image-20220822172623-2.png]] 61 + 62 +**3)Set Serial port parameters** 63 + 64 +Follow the steps below to configure Serial port parameters 65 + 66 +Baud rate:115200 67 + 68 +Data bit:8 69 + 70 +Stop bit:1 71 + 72 +Parity:No verification 73 + 74 +[[image:image-20220822172657-3.png]] 75 + 76 +**4)Registers list** 77 + 78 +[[image:image-20220822172730-4.png]] 79 + 80 +**V-BOX software configuration** 81 + 82 +**1)V-BOX programming software** 83 + 84 + [[image:image-20220824104124-1.png]] 85 + 86 +**2)V-NET add device** 87 + 88 +Open V-NET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the access key, password and remark, to add the device. 89 + 90 +[[image:image-20220824104909-2.png]] 91 + 92 + 93 +**3)Set communication port parameters** 94 + 95 +Click the communication configuration button on the left to find the communication protocol with LX5V. After selecting the protocol, configure the communication parameters of the COM port. 96 + 97 +Baud rate:115200 98 + 99 +Data bit:8 100 + 101 +Stop bit:1 102 + 103 +Parity:No verification 104 + 105 +[[image:image-20220824142130-1.png]] 106 + 107 +**hardware connection** 108 + 109 +**1)Hardware wiring diagram** 110 + 111 +[[image:image-20220824142546-2.png]] 112 + 113 +[[image:image-20220824142643-3.png]] 114 + 115 +The above are all the steps for establishing serial port communication between V-BOX with LX5V PLC. 116 + 117 +== **LX5V-N Ethernet protocol** == 118 + 119 +This example introduces the establishment of Ethernet communication between V-BOX and LX5V-N. It is introduced through three parts: PLC software configuration, V-BOX software configuration, and hardware wiring. 120 + 121 +**Software configuration of PLC** 122 + 123 +**1)PLC programming software** 124 + 125 +[[image:image-20220824142722-1.png]] 126 + 127 +**2)New PLC project** 128 + 129 +Click New Project and select the PLC model. 130 + 131 +[[image:image-20220824143613-1.png]] 132 + 133 +**3)Set Ethernet port parameters** 134 + 135 +Follow the steps below to configure Ethernet parameters 136 + 137 +PLC IP address:192.168.39.200 138 + 139 +default gateway:192.168.39.1 140 + 141 +subnet mask:255.255.255.0 142 + 143 +[[image:image-20220824143744-2.png]] 144 + 145 +**4)Registers list** 146 + 147 +[[image:image-20220822172730-4.png]] 148 + 149 +(% id="cke_bm_22473S" style="display:none" %)** **(%%)**V-BOX software configuration** 150 + 151 +**1)V-BOX programming software** 152 + 153 + [[image:image-20220824104124-1.png]] 154 + 155 +**2)V-NET add device** 156 + 157 +Open V-NET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the access key, password and remark, to add the device. 158 + 159 +[[image:image-20220824104909-2.png]] 160 + 161 +**3)Set communication port parameters** 162 + 163 +Click Communication to configure the LX5V plc protocol and IP address. 164 + 165 +[[image:image-20220824144619-1.png]] 166 + 167 +**hardware connection** 168 + 169 +**1)Hardware wiring diagram** 170 + 171 +[[image:image-20220824151127-2.png]] 172 + 173 +The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC. 174 + 175 += **Rockwell PLC** = 176 + 177 +== (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** == 178 + 179 +MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 180 + 181 +**HMI Settings** 182 + 183 +|**Item**|**Settings**|**Note** 184 +|Protocol|Allen-Bradlley MicroLogix| 185 +|Connection|RS232| 186 +|Baud rate|19200| 187 +|Data bit|8| 188 +|Parity|None| 189 +|Stop bit|1| 190 +|PLC station No.|1| 191 + 192 +**Address List** 193 + 194 +|**Type**|**Device registers**|**Format**|**Range**|**Note** 195 +|(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15| 196 +|O|O d.d|0.0~~255.15| 197 +|B|B nnhh.dd|0.0~~ffff.15|nn: block number (hex) 198 +|S|S d.d|0.0~~255.15| 199 +|N|N nnhh.dd|0.0~~ffff.15|nn: block number (hex) 200 +|(% rowspan="9" %)Word|S|S d|0~~255| 201 +|TS|TS nnhh|0~~ffff|(% rowspan="8" %)nn: block number (hex) 202 +|TP|TP nnhh|0~~ffff 203 +|CS|CS nnhh|0~~ffff 204 +|CP|CP nnhh|0~~ffff 205 +|N|N nnhh|0~~ffff 206 +|C|C nnhh|0~~ffff 207 +|T|T nnhh|0~~ffff 208 +|R|R nnhh|0~~ffff 209 + 210 +**Cable Wiring** 211 + 212 +[[image:image-20220824110724-1.png]] 213 + 214 + 215 + 216 +== **CompactLogix Protocol** == 217 + 65 65 ((( 66 -This example introduces the establishment of Ethernet communication between Wecon V-box and Allen-Bradley L1769. It is introduced through three parts: PLC software configuration, V-box software configuration, and hardware wiring. 219 +((( 220 +This example introduces the establishment of Ethernet communication between Wecon V-box and CompactLogix L1769. It is introduced through three parts: PLC software configuration, V-box software configuration, and hardware wiring. 67 67 ))) 222 +))) 68 68 69 69 ((( 70 - 225 +(% class="wikigeneratedid" id="HSoftwareconfigurationofPLC" %) 226 +((( 227 +**Software configuration of PLC** 71 71 ))) 72 72 230 +(% class="wikigeneratedid" id="HPLCprogrammingsoftware" %) 73 73 ((( 74 -== **Software configuration of PLC** == 232 +**1)PLC programming software** 233 +))) 75 75 76 - === **PLC programmingsoftware** ===235 +[[image:image-20220714162600-1.png]] 77 77 78 - [[image:image-20220714113935-3.png]] 79 - 80 -=== **New PLC project** === 81 - 237 +(% class="wikigeneratedid" id="HNewPLCproject" %) 82 82 ((( 83 - ClickNew Projectand select the PLC model.239 +**2)New PLC project** 84 84 ))) 85 85 86 86 ((( 87 - [[image:image-20220714114247-4.png]] 243 +((( 244 +Click New Project and select the PLC model. 88 88 ))) 246 +))) 89 89 90 90 ((( 91 - 14257-5.png]]249 +[[image:image-20220714162617-2.png]] 92 92 ))) 93 93 94 94 ((( 95 95 254 + 255 +[[image:image-20220714162652-4.png]] 96 96 ))) 97 97 98 98 ((( 99 -=== **Set Ethernet parameters** === 259 +(% class="wikigeneratedid" id="HSetEthernetparameters" %) 260 +((( 261 +**3)Set Ethernet parameters** 262 +))) 100 100 101 101 ((( 265 +((( 266 +((( 102 102 Follow the steps below to configure Ethernet parameters 103 103 ))) 269 +))) 270 +))) 104 104 105 105 ((( 273 +((( 274 +((( 106 106 PLC IP address:192.168.40.101 107 107 ))) 277 +))) 278 +))) 108 108 109 109 ((( 281 +((( 282 +((( 110 110 default gateway:192.168.40.1 111 111 ))) 285 +))) 286 +))) 112 112 113 113 ((( 289 +((( 290 +((( 114 114 subnet mask:255.255.255.0 115 115 ))) 293 +))) 294 +))) 116 116 117 117 ((( 118 - 15012-6.png]]297 +[[image:image-20220714162713-5.png]] 119 119 ))) 120 120 121 121 ((( ... ... @@ -123,95 +123,218 @@ 123 123 ))) 124 124 125 125 ((( 126 -== **V-box software configuration** == 305 +(% class="wikigeneratedid" id="HV-boxsoftwareconfiguration" %) 306 +((( 307 +**V-box software configuration** 308 +))) 127 127 128 -=== **V-box programming software** === 310 +(% class="wikigeneratedid" id="HV-boxprogrammingsoftware" %) 311 +((( 312 +**1)V-box programming software** 313 +))) 129 129 130 - [[image:image-20220714115214-7.png]] 315 +(% class="wikigeneratedid" %) 316 +((( 317 + [[image:image-20220714162725-6.png]] 318 +))) 131 131 320 +(% class="wikigeneratedid" id="HConfiguredevicenetwork" %) 321 +((( 322 +**2)Configure device network** 323 +))) 132 132 133 -=== **Configure device network** === 134 - 135 135 ((( 326 +((( 327 +((( 136 136 Click the Configuration Download button[[image:image-20220714115308-8.png||height="22" width="15"]], It is used to configure the device network, update the device time, obtain the device machine code, check the device network, etc. 137 137 ))) 138 138 139 139 ((( 140 -In the example below, the IP address of V-Box is configured as 192.168.40.66, and the networking method is 4G connection .332 +In the example below, the IP address of V-Box is configured as 192.168.40.66, and the networking method is 4G connection 141 141 ))) 142 - 143 - [[image:image-20220714115440-9.png||height="425" width="791"]] 144 144 ))) 145 145 ))) 146 146 147 -== **V-net add device** == 337 +((( 338 +((( 339 +[[image:image-20220714162737-7.png]] 340 + 341 + 148 148 ))) 343 +))) 344 +))) 345 +))) 149 149 347 +(% class="wikigeneratedid" id="HV-netadddevice" %) 150 150 ((( 151 - OpenVNET client software→ add device. As shown inthe figure below, click "+" in the order of steps,andthe AddDevicewindow will pop up, enter the device machine code/product code, device password, and device alias to add the device.349 +**3)V-net add device** 152 152 ))) 351 +))) 153 153 154 154 ((( 155 - [[image:image-20220714115640-10.png||height="430" width="797"]] 354 +((( 355 +Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device. [[image:image-20220714162752-8.png]] 156 156 ))) 157 157 158 -((( 159 159 160 160 ))) 161 161 162 162 ((( 163 -=== **Set communication port parameters** === 362 +(% class="wikigeneratedid" id="HSetcommunicationportparameters" %) 363 +((( 364 +**4)Set communication port parameters** 365 +))) 164 164 367 +((( 165 165 In the device list on the left, find the Vbox that communicates with the L1769, click it and select configuration,communication port configuration in the main interface to add a communication protocol. 369 +))) 166 166 167 - 15848-11.png||height="432" width="802"]]371 +[[image:image-20220714162805-9.png]] 168 168 ))) 169 169 170 - 374 +((( 171 171 The communication port is selected as Ethernet, the device type is selected as Allen-Bradley, the protocol is Allen-BradleyMicro850_FreeTag EthemetIP, and the IP is the internal IP address of the L1769 PLC. The port number is 44818. 376 +))) 172 172 378 +[[image:image-20220714162814-10.png]] 173 173 174 174 175 -== **Siemens S7-1200** == 381 +((( 382 +After adding the protocol Allen-BradleyMicro850_FreeTag, click[[image:image-20220714143838-2.png]]icon add label.[[image:image-20220714162827-11.png]] 383 +))) 176 176 177 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]] 385 +(% class="wikigeneratedid" id="HEngineeringproduction" %) 386 +((( 387 +**5)Engineering production** 388 +))) 178 178 390 +(% class="wikigeneratedid" %) 391 +((( 392 +((( 393 +According to your own needs, use the V-NET client software to edit the required data monitoring points. 394 +))) 395 + 396 +[[image:image-20220714162841-12.png]] 397 + 398 + 399 +((( 400 +**hardware connection** 401 +))) 402 +))) 403 + 404 +((( 405 +**1)Hardware wiring diagram** 406 +))) 407 + 408 +((( 409 +((( 410 +This example introduces Wecon V-box with Allen-Bradley L1769 PLC to establish communication through Ethernet. The connection diagram is as follows: 411 +))) 412 + 413 +[[image:image-20220714162856-13.png]] 414 + 415 +((( 416 +The above are all the steps for establishing Ethernet communication between Wecon V-box with CompactLogix L1769 PLC. 417 + 418 + 179 179 == **Allen-Bradley Ethernet DF1** == 180 180 181 181 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]] 182 182 183 -== **Communication with S7-200 Smart** == 184 184 185 - [[downloadlink>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]]424 += **Siemens PLC** = 186 186 187 -== ** DeltaDVPEthernet** ==426 +== **S7-200 Smart Ethernet Protocol** == 188 188 189 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]] 428 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]] 429 +))) 430 +))) 190 190 191 -== ** Delta DVPSerialProtocol** ==432 +== **S7-1200 Ethernet Protocol** == 192 192 193 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/ Delta%20DVP%20Ethernet.zip]]434 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]] 194 194 195 -= =**Communicate withMitsubishiFX Series** ==436 += **Mitsubishi PLC** = 196 196 438 +== **Mitsubishi FX Series Protocol** == 439 + 197 197 [[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20Mitsubishi%20FX%20Series.zip]] 198 198 199 -= =**CommunicatewithVB inverter** ==442 += **Delta PLC** = 200 200 201 - [[downloadlink>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20VB%20inverter.zip]]444 +== **DVP Ethernet Protocol** == 202 202 203 - ==**OmronCP1Series** ==446 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]] 204 204 448 +== **DVP Serial Protocol** == 449 + 450 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]] 451 + 452 += **Omron PLC** = 453 + 454 +== **CP1 Series Protocol** == 455 + 205 205 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]] 206 206 207 -== ** OmronCJ2M** ==458 +== **CJ2M Series Protocol** == 208 208 209 209 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]] 210 210 211 -= ** 2 Userdefine protocol** =462 += **Modbus RTU** = 212 212 213 - Moreserial port script instruction,please refer manual:[[Lua script function>>doc:V-BOX.V-Net.1\.UserManual.04 Lua Script.01 Lua Functions.WebHome]]~-~-->[[3.Serialport operation>>url:http://docs.we-con.com.cn/wiki/vbox/view/HMI/04.Lua%20script%20%20function%20and%20operation/01.Lua%20script%20function/#H3.Serialportoperation]]464 +== **V-BOX as master** == 214 214 466 +Select the protocol “(% class="mark" %)Modbus RTU Slave(All Fuction)”, 467 + 468 +(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity 469 + 470 +(% style="text-align:center" %) 471 +[[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]] 472 + 473 +== **V-BOX as slave** == 474 + 475 +Select the protocol “(% class="mark" %)**Modbus RTU Master”**, 476 + 477 +(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity 478 + 479 +(% style="text-align:center" %) 480 +[[image:1624348709622-711.png||queryString="width=809&height=493" height="488" width="800" class="img-thumbnail"]] 481 + 482 +**Address List** 483 + 484 +(% class="table-bordered" %) 485 +|**Type**|**Register**|**Function code & Description** 486 +|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers) 487 +|06 (write single register: write a binary value to a holding register) 488 +|10 (write values to multiple addresses ) 489 +|(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers) 490 +|06 (write single register: write a binary value to a holding register) 491 +|10 (write values to multiple addresses ) 492 +|(% rowspan="3" %)W6|03 (read holding register: read current binary value in one or more holding registers) 493 +|06 (write single register: write a binary value to a holding register) 494 +|10 (write values to multiple addresses ) 495 +|(% rowspan="2" %)W16|03 (read holding register: read current binary value in one or more holding registers) 496 +|10 (write values to multiple addresses ) 497 +|(% rowspan="11" %)Bit|(% rowspan="3" %)0|01 (Read coil state) 498 +|05 (Force a single coil to force the on/off state of a logic coil) 499 +|0F (Write multiple bits, ie write continuously) 500 +|(% rowspan="3" %)1|02 (Read the input state) 501 +|05 (Force a single coil to force the on/off state of a logic coil) 502 +|0F (Write multiple bits) 503 +|(% rowspan="3" %)W5|01 (Read coil state to obtain the current state of a set of logic coils) 504 +|05 (Force a single coil to force the on/off state of a logic coil) 505 +|0F (Write multiple bits) 506 +|(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils) 507 +|0F (Write multiple bits) 508 + 509 +== **communicate with VB inverter** == 510 + 511 +[[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20VB%20inverter.zip]] 512 + 513 += **User define protocol** = 514 + 515 +More serial port script instruction,please refer manual:[[Lua script function>>doc:V-BOX.V-Net.Manual.04 Lua Script.01 Lua Functions.WebHome]]~-~-->[[3.Serial port operation>>url:http://docs.we-con.com.cn/wiki/vbox/view/HMI/04.Lua%20script%20%20function%20and%20operation/01.Lua%20script%20function/#H3.Serialportoperation]] 516 + 215 215 == **Read the temperature sensor.** == 216 216 217 217 the commond format is as beliow:
- image-20220714143820-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.4 MB - Content
- image-20220714143838-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +520 bytes - Content
- image-20220714143849-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.3 MB - Content
- image-20220714160006-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.3 MB - Content
- image-20220714160034-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +135.2 KB - Content
- image-20220714160120-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +58.8 KB - Content
- image-20220714160335-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +264.1 KB - Content
- image-20220714160412-5.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +58.5 KB - Content
- image-20220714160439-6.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +104.0 KB - Content
- image-20220714160541-7.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.7 KB - Content
- image-20220714160651-8.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +135.2 KB - Content
- image-20220714160843-9.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +165.9 KB - Content
- image-20220714160943-10.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +50.2 KB - Content
- image-20220714161014-11.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +94.3 KB - Content
- image-20220714161120-12.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +94.3 KB - Content
- image-20220714161229-13.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +62.5 KB - Content
- image-20220714161445-14.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +131.2 KB - Content
- image-20220714162600-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +58.8 KB - Content
- image-20220714162617-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.3 MB - Content
- image-20220714162629-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +58.5 KB - Content
- image-20220714162652-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +58.5 KB - Content
- image-20220714162713-5.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +104.0 KB - Content
- image-20220714162725-6.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.7 KB - Content
- image-20220714162737-7.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +135.2 KB - Content
- image-20220714162752-8.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +135.2 KB - Content
- image-20220714162805-9.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +165.9 KB - Content
- image-20220714162814-10.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +50.2 KB - Content
- image-20220714162827-11.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +94.3 KB - Content
- image-20220714162841-12.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +62.5 KB - Content
- image-20220714162856-13.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +131.6 KB - Content
- image-20220820164423-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +18.4 KB - Content
- image-20220822172124-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +38.7 KB - Content
- image-20220822172228-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +48.8 KB - Content
- image-20220822172553-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +19.9 KB - Content
- image-20220822172623-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +111.2 KB - Content
- image-20220822172657-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +141.6 KB - Content
- image-20220822172730-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +130.7 KB - Content
- image-20220824104124-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +14.6 KB - Content
- image-20220824104909-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +278.8 KB - Content
- image-20220824110724-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +79.1 KB - Content
- image-20220824120406-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +31.9 KB - Content
- image-20220824120507-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +10.3 KB - Content
- image-20220824120524-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +23.4 KB - Content
- image-20220824120547-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +49.2 KB - Content
- image-20220824120614-5.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +30.9 KB - Content
- image-20220824142130-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +122.2 KB - Content
- image-20220824142546-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +111.2 KB - Content
- image-20220824142643-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +38.3 KB - Content
- image-20220824142722-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +7.3 KB - Content
- image-20220824143613-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +206.2 KB - Content
- image-20220824143744-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +126.0 KB - Content
- image-20220824144619-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +126.2 KB - Content
- image-20220824151127-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +85.5 KB - Content