... ... @@ -1,4 +1,4 @@
1 -= (% style="color:inherit; font-family:inherit" %)**Wecon PLC**(%%) =
1 += Create communication with WECON PLC =
2 2  
3 3  == **LX3V Serial Protocol** ==
4 4  
... ... @@ -176,7 +176,7 @@
176 176  
177 177  The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC.
178 178  
179 -= **Rockwell PLC** =
179 += Create communication with **Rockwell PLC** =
180 180  
181 181  == (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** ==
182 182  
... ... @@ -217,7 +217,7 @@
217 217  
218 218  [[image:image-20220824110724-1.png]]
219 219  
220 -== **Micro850_FreeTag** ==
220 +== **Micro850_FreeTag Protocol** ==
221 221  
222 222  (((
223 223  (((
... ... @@ -425,7 +425,7 @@
425 425  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]]
426 426  
427 427  
428 -= **Siemens PLC** =
428 += Create communication with **Siemens PLC** =
429 429  
430 430  == **S7-200 Smart Ethernet Protocol** ==
431 431  
... ... @@ -608,9 +608,8 @@
608 608  
609 609  [[image:image-20220824162342-2.png]]
610 610  
611 += Create communication with **Mitsubishi PLC** =
611 611  
612 -= **Mitsubishi PLC** =
613 -
614 614  == **FX1S,1N,2N Serial Protocol** ==
615 615  
616 616  Supported Series: Mitsubishi FX1S, FX1N, FX2N series
... ... @@ -868,7 +868,7 @@
868 868  
869 869  Mitsubishi L02 series CPU built-in serial port.
870 870  
871 -**V-BOX Settings**
870 +**1)V-BOX Settings**
872 872  
873 873  |**Item**|**Settings**|**Note**
874 874  |Protocol|Mitsubishi L02|
... ... @@ -879,7 +879,7 @@
879 879  |Stop bit|1|
880 880  |PLC station No.|1~~255|Need to be the same as PLC settings
881 881  
882 -**Address List**
881 +**2)Address List**
883 883  
884 884  |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
885 885  |Bit|X|X|X h|0~~FFFF|
... ... @@ -912,11 +912,11 @@
912 912  |Word|ZR|ZR|ZR h|0~~FFFF|
913 913  |Word|D|D|D d|0~~99999|
914 914  
915 -**Communication Settings**
914 +**3)Communication Settings**
916 916  
917 917  [[image:image-20220825160648-3.png]]
918 918  
919 -**5)Cable Wiring**
918 +**4)Cable Wiring**
920 920  
921 921  * **RS422**
922 922  
... ... @@ -1067,7 +1067,7 @@
1067 1067  
1068 1068  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png"]]
1069 1069  
1070 -= **Delta PLC** =
1069 += Create communication with **Delta PLC** =
1071 1071  
1072 1072  == **DVP Ethernet Protocol** ==
1073 1073  
... ... @@ -1077,18 +1077,126 @@
1077 1077  
1078 1078  [[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
1079 1079  
1080 -= **Omron PLC** =
1079 +== **AS Ethernet Protocol** ==
1081 1081  
1082 -== **CP1 Series Protocols** ==
1081 +**1)V-BOX Settings**
1083 1083  
1083 +|=**Items**|=**Settings**|=**Note**
1084 +|Protocol|DELTA AS300 MODBUS TCP|
1085 +|Connection|Ethernet|
1086 +|Port No.|502|
1087 +|Device No.|1|
1088 +|HMI No.|0|
1089 +
1090 +**2)Address List**
1091 +
1092 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1093 +|Bit|X|X|X d|0~~63|
1094 +|Bit|Y|Y|Y d|0~~63|
1095 +|Bit|D|D|D d|0~~29999|
1096 +|Bit|M|M|M d|0~~8191|
1097 +|Bit|SM|SM|SM d|0~~4095|
1098 +|Bit|S|S|S h|0~~2047|
1099 +|Bit|T|T|T d|0~~511|
1100 +|Bit|C|C|C d|0~~511|
1101 +|Bit|HC|HC|HC d|0~~255|
1102 +|Word|X|X|X h|0~~63|
1103 +|Word|Y|Y|Y d|0~~63|
1104 +|Word|SR|SR|SR d|0~~2047|
1105 +|Word|D|D|D d|0~~29999|
1106 +|Word|T|T|T d|0~~511|
1107 +|Word|C|C|C h|0~~511|
1108 +|Word|E|E|E d|0~~9|
1109 +
1110 +**3)Configure the communication protocol**
1111 +
1112 +
1113 +[[image:image-20220831160010-4.png]]
1114 +
1115 +**4)Cable Wiring**
1116 +
1117 +Figure
1118 +
1119 +[[image:image-20220831155101-1.png]][[image:image-20220831160055-5.png]]
1120 +
1121 +Pin Definition Diagram
1122 +
1123 +[[image:image-20220831155157-3.png]]
1124 +
1125 += Create communication with **Omron PLC** =
1126 +
1127 +== **CP1 Series Protocol ** ==
1128 +
1084 1084  [[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]]
1085 1085  
1086 -== **CP2M Series Protocols** ==
1131 +== **CP2M Series Protocol** ==
1087 1087  
1088 1088  [[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]]
1089 1089  
1090 -= **Modbus RTU** =
1091 1091  
1136 +== **EC55 Protocol** ==
1137 +
1138 +Supported device: EC55 temperature instrument
1139 +
1140 +**1)V-BOX Settings**
1141 +
1142 +|**Items**|**Settings**|**Note**
1143 +|Protocol|Omron EC55|
1144 +|Connection|RS485 (9600, 2, 7, EVEN)|
1145 +|Port No.|None|
1146 +|PLC station No.|0|
1147 +
1148 +**2)Address List**
1149 +
1150 +|**Type**|**Register**|**Device range**|**HMI range**|**Function**
1151 +|(% rowspan="3" %)Double word|C0|0-13 (Hex)|0-19|Set read only parameter for area 0
1152 +|C1|0-4D(Hex)|0-77|Set Read/Write parameter for area 0
1153 +|C3|0-CD(Hex)|0-205|Set Read/Write parameter for area 1
1154 +|(% rowspan="6" %)Word|80|0-13(Hex)|0-19|Set read only parameter in area 0
1155 +|81|0-4D(Hex)|0-77|Set Read/Write parameter in area 0
1156 +|83|0-CD(Hex)|0-205|Set Read/Write parameter in area 1
1157 +|CP|-|0-6|Read controller intrinsic property
1158 +|CS|-|0-2|Read controller states
1159 +|CA|-|0-17|Action command
1160 +
1161 +**3)Device Settings**
1162 +
1163 +Omron E5CC PLC configuration
1164 +
1165 +After entering the Communication Settings menu, please set the parameters to the default values for the following table. Press the cycle key of the instrument to enter the next setting.
1166 +
1167 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_3d95e093792ba98a.png?width=550&height=229&rev=1.1||alt="12.PLC Protocol_html_3d95e093792ba98a.png" height="229" width="550"]]
1168 +
1169 +According to PLC configuration and communication port configuration information of the HMI, provide the corresponding steps and configuration screenshots. This configuration needs to communicate properly with the above PLC configuration. The project settings are as follows
1170 +
1171 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_be583aa69dd6cf4c.png?width=550&height=242&rev=1.1||alt="12.PLC Protocol_html_be583aa69dd6cf4c.png" height="242" width="550"]]
1172 +
1173 +**✎Note:** The communication settings for HMI should be consistent with this setting.
1174 +
1175 +**4)Configure the communication protocol**
1176 +
1177 +[[image:image-20220831161041-1.png]]
1178 +
1179 +**5)Cable Wiring**
1180 +
1181 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5e9a81a14106da9e.png?width=392&height=223&rev=1.1||alt="12.PLC Protocol_html_5e9a81a14106da9e.png" height="223" width="392"]]
1182 +
1183 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_1897d92be6948d58.png?width=393&height=223&rev=1.1||alt="12.PLC Protocol_html_1897d92be6948d58.png" height="223" width="393"]]
1184 +
1185 +**✎Note:**
1186 +
1187 +* COM3 only available in PI8000/PI9000 series.
1188 +* CA address could not support continuous writing function;
1189 +* Because of CP address intrinsic property: read control intrinsic property, so please place the character input part in use. Set address with CP0 and character length 10, used to display controller type. And place a number input part, set address with CP5 (cache size). Do not place other CP type address without CP0 in screen, otherwise CP type address is invalid
1190 +* When set value into read & write address, it is necessary to switch the temperature instrument meter to the corresponding interface according to the menu of the instrument where the address locates, so that the value could be written, otherwise, the value could not be written; When the communication write setting of the instrument is turned off, the writing function is invalid. Writing function could be opened by using the 00 address of the CA register, which write 01 value.
1191 +* When continuous writing of a value to a read-write address, please make sure all continuous writing address could be written. Otherwise, if one of these addresses could not be written, then all continuous writing commands will fail.
1192 +* Because of the mechanism problem, this protocol could not support CompoWay/F function that is read-write function of variables in protocol document.
1193 +* When using double-word address, set the data format to 32 bits, otherwise the read/write function is unable.
1194 +* Please set the communication delay time of 10ms in setting, to avoid that the instrument may not be able to communicate in a short time due to too fast data access and too much connection requests.
1195 +* [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_d428cad280fdefb3.png?width=347&height=276&rev=1.1||alt="12.PLC Protocol_html_d428cad280fdefb3.png" height="276" width="347"]]Because of the particularity of the instrument, it is necessary to write the value of the address in the menu interface corresponding to the address, and to enter the menu where the address locates, so that the value could be written.
1196 +
1197 += Create communication with **Modbus RTU** =
1198 +
1092 1092  == **V-BOX as Slave** ==
1093 1093  
1094 1094  Select the protocol "Modbus RTU Slave (All Fuction)",
image-20220831155101-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +34.6 KB
Content
image-20220831155129-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +44.9 KB
Content
image-20220831155157-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +20.8 KB
Content
image-20220831160010-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +59.6 KB
Content
image-20220831160055-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +51.5 KB
Content
image-20220831161041-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +58.1 KB
Content