Changes for page 1 Communication

Last modified by Hunter on 2024/07/01 10:54

From version 14.1
edited by Ben
on 2022/07/14 14:39
Change comment: There is no comment for this version
To version 26.1
edited by Ben
on 2022/08/20 11:58
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,7 +1,5 @@
1 -= **1 General communication with PLC** =
1 += **Modbus RTU** =
2 2  
3 -== **Modbus RTU** ==
4 -
5 5  === **V-BOX as master** ===
6 6  
7 7  Select the protocol “(% class="mark" %)Modbus RTU Slave(All Fuction)”,
... ... @@ -47,73 +47,292 @@
47 47  |(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils)
48 48  |0F (Write multiple bits)
49 49  
50 -== **WECON LX3V PLC** ==
48 += **WECON PLC** =
51 51  
52 -Select the protocol (% class="mark" %)"WECON LX3V"
50 +Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM
53 53  
54 -(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity same with PLC.
52 +**HMI Settings**
55 55  
56 -(% class="mark" %)WECON PLC RS422 port,default communication parameters is 9600,1,7,ZEVEN
54 +|**Item**|**Settings**|**Note**
55 +|Protocol|WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM|
56 +|Connection|RS422/RS485|
57 +|Baud rate|9600|
58 +|Data bit|7|
59 +|Parity|EVEN|
60 +|Stop bit|1|
61 +|PLC station No.|1|
57 57  
63 +**Address List**
64 +
65 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
66 +|(% rowspan="6" %)Bit|X|X|Xo|0~~303237|
67 +|Y|Y|Y o|0~~303237|
68 +|M|M|M d|0~~99999|
69 +|T|T|T d|0~~99999|
70 +|C|C|C d|0~~99999|
71 +|S|S|S d|0~~99999|
72 +|(% rowspan="8" %)Word|X|X|Xo|0~~303237|
73 +|Y|Y|Y o|0~~303237|
74 +|M|M|M d|0~~99999|
75 +|T|T|T d|0~~99999|
76 +|C|C|C d|0~~199|
77 +|D|D|D d|0~~7999|
78 +|S|S|S d|0~~99999|
79 +|SD|SD|SD d|8000~~9999|
80 +
81 +**Cable Wiring**
82 +
83 +* **RS485**
84 +
58 58  (% style="text-align:center" %)
86 +[[image:12.PLC Protocol_html_5e9a81a14106da9e.png||data-xwiki-image-style-alignment="center" height="223" width="392" class="img-thumbnail"]]
87 +
88 +(% style="text-align:center" %)
89 +[[image:12.PLC Protocol_html_1897d92be6948d58.png||data-xwiki-image-style-alignment="center" height="223" width="393" class="img-thumbnail"]]
90 +
91 +* **RS422**
92 +
93 +(% style="text-align:center" %)
94 +[[image:12.PLC Protocol_html_5c7fca9a70da2ee8.png||data-xwiki-image-style-alignment="center" height="247" width="389" class="img-thumbnail"]]
95 +
96 +**✎Note:**
97 +
98 +* HMI COM3 is available in PI8000 series and COM3 is in COM2(hardware PIN 7 and PIN 8) .
99 +* If PLC <= 20 points,such as LX3V-1208/LX3V-0806 PLC,PLC RS485A and RS485B mean PLC COM2 RS485+ and RS485- .PLC COM2 can support modbus. Please refer to PLC COM2 setting manual.
100 +
101 +[[https:~~/~~/drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing>>url:https://drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing]]
102 +
103 +== HMI and Wecon LX5V serial communication ==
104 +
105 +This example introduces the establishment of serial port communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
106 +
107 +**Software configuration of PLC**
108 +
109 +**1)PLC programming software**
110 +
111 +[[image:image-20220810164710-1.png]]
112 +
113 +**2)New PLC project**
114 +
115 +Click New Project and select the PLC model.
116 +
117 +[[image:image-20220810172412-1.png]]
118 +
119 +**3)Set Serial port parameters**
120 +
121 +Follow the steps below to configure Serial port parameters
122 +
123 +Baud rate:115200
124 +
125 +Data bit:8
126 +
127 +Stop bit:1
128 +
129 +Parity:No verification
130 +
131 +[[image:image-20220810165759-3.png]]
132 +
133 +**4)Registers list**
134 +
135 +[[image:image-20220811102219-3.png]]
136 +
137 +**HMI software configuration**
138 +
139 +**1)HMI programming software**
140 +
141 + [[image:image-20220810171237-4.png]]
142 +
143 +**2)New HMI project**
144 +
145 +Click New Project and select the HMI model.
146 +
147 +[[image:image-20220810172010-5.png]]
148 +
149 +**3)Set communication port parameters**
150 +
151 +Click the communication configuration button on the left to find the communication protocol with LX5V. After selecting the protocol, configure the communication parameters of the COM port.
152 +
153 +Baud rate:115200
154 +
155 +Data bit:8
156 +
157 +Stop bit:1
158 +
159 +Parity:No verification
160 +
161 +[[image:image-20220811104012-1.png]]
162 +
163 +**hardware connection**
164 +
165 +**1)Hardware wiring diagram**
166 +
167 +This example introduces WeconHMI with LX5V PLC to establish communication through serial port. The connection diagram is as follows:
168 +
169 +[[image:image-20220811103005-4.png]]
170 +
171 +[[image:image-20220811103227-7.png]]
172 +
173 +The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC.
174 +
175 +== HMI and Wecon LX5V-N Ethernet communication ==
176 +
177 + This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
178 +
179 +**Software configuration of PLC**
180 +
181 +**1)PLC programming software**
182 +
183 +[[image:image-20220810164710-1.png]]
184 +
185 +**2)New PLC project**
186 +
187 +Click New Project and select the PLC model.
188 +
189 +[[image:image-20220811115454-1.png]]
190 +
191 +**3)Set Ethernet port parameters**
192 +
193 +Follow the steps below to configure Ethernet parameters
194 +
195 +PLC IP address:192.168.39.200
196 +
197 +default gateway:192.168.39.1
198 +
199 +subnet mask:255.255.255.0
200 +
201 +[[image:image-20220811140530-2.png]]
202 +
203 +**4)Registers list**
204 +
205 +[[image:image-20220811102219-3.png]]
206 +
207 +**HMI software configuration**
208 +
209 +**1)HMI programming software**
210 +
211 + [[image:image-20220810171237-4.png]]
212 +
213 +**2)New HMI project**
214 +
215 +Click New Project and select the HMI model.
216 +
217 +[[image:image-20220810172010-5.png]]
218 +
219 +**3)Set communication port parameters**
220 +
221 +Click the project setting button on the left to configure the IP address of the HMI machine to ensure that the HMI and PLC IP remain in a local area network.
222 +
223 +HMI IP address:192.168.39.201
224 +
225 +default gateway:192.168.39.1
226 +
227 +subnet mask:255.255.255.0
228 +
229 +[[image:image-20220811170753-2.png]]
230 +
231 +Next, click Communication Settings to configure the IP of the HMI communication object.
232 +
233 +[[image:image-20220811163047-1.png]]
234 +
235 +**hardware connection**
236 +
237 +**1)Hardware wiring diagram**
238 +
239 +This example introduces WeconHMI with LX5V-N PLC to establish communication through ethernet. The connection diagram is as follows:
240 +
241 +[[image:image-20220811170248-1.png]]
242 +
243 +The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC.
244 +
245 +(% style="text-align:center" %)
59 59  [[image:1624348978863-771.png||queryString="width=812&height=494" height="487" width="800" class="img-thumbnail"]]
60 60  
61 -== **2 Communication with Allen-Bradley CompactLogix L1769** ==
248 += **Rockwell PLC** =
62 62  
250 +== **Communication with Allen-Bradley CompactLogix L1769** ==
251 +
63 63  (((
253 +(((
64 64  This example introduces the establishment of Ethernet communication between Wecon V-box and Allen-Bradley L1769. It is introduced through three parts: PLC software configuration, V-box software configuration, and hardware wiring.
65 65  )))
66 66  
67 -(((
68 68  
69 69  )))
70 70  
71 71  (((
72 -== **Software configuration of PLC** ==
261 +(% class="wikigeneratedid" id="HSoftwareconfigurationofPLC" %)
262 +(((
263 +**Software configuration of PLC**
264 +)))
73 73  
74 -=== **PLC programming software** ===
266 +(% class="wikigeneratedid" id="HPLCprogrammingsoftware" %)
267 +(((
268 +**1)PLC programming software**
269 +)))
75 75  
76 - [[image:image-20220714113935-3.png]]
271 +[[image:image-20220714162600-1.png]]
77 77  
78 -=== **New PLC project** ===
79 -
273 +(% class="wikigeneratedid" id="HNewPLCproject" %)
80 80  (((
81 -Click New Project and select the PLC model.
275 +**2)New PLC project**
82 82  )))
83 83  
84 84  (((
85 - [[image:image-20220714114247-4.png]]
279 +(((
280 +Click New Project and select the PLC model.
86 86  )))
282 +)))
87 87  
88 88  (((
89 - [[image:image-20220714114257-5.png]]
285 +[[image:image-20220714162617-2.png]]
90 90  )))
91 91  
92 92  (((
93 93  
290 +
291 +[[image:image-20220714162652-4.png]]
94 94  )))
95 95  
96 96  (((
97 -=== **Set Ethernet parameters** ===
295 +(% class="wikigeneratedid" id="HSetEthernetparameters" %)
296 +(((
297 +**3)Set Ethernet parameters**
298 +)))
98 98  
99 99  (((
301 +(((
302 +(((
100 100  Follow the steps below to configure Ethernet parameters
101 101  )))
305 +)))
306 +)))
102 102  
103 103  (((
309 +(((
310 +(((
104 104  PLC IP address:192.168.40.101
105 105  )))
313 +)))
314 +)))
106 106  
107 107  (((
317 +(((
318 +(((
108 108  default gateway:192.168.40.1
109 109  )))
321 +)))
322 +)))
110 110  
111 111  (((
325 +(((
326 +(((
112 112  subnet mask:255.255.255.0
113 113  )))
329 +)))
330 +)))
114 114  
115 115  (((
116 - [[image:image-20220714115012-6.png]]
333 +[[image:image-20220714162713-5.png]]
117 117  )))
118 118  
119 119  (((
... ... @@ -121,75 +121,139 @@
121 121  )))
122 122  
123 123  (((
124 -== **V-box software configuration** ==
341 +(% class="wikigeneratedid" id="HV-boxsoftwareconfiguration" %)
342 +(((
343 +**V-box software configuration**
344 +)))
125 125  
126 -=== **V-box programming software** ===
346 +(% class="wikigeneratedid" id="HV-boxprogrammingsoftware" %)
347 +(((
348 +**1)V-box programming software**
349 +)))
127 127  
128 - [[image:image-20220714115214-7.png]]
351 +(% class="wikigeneratedid" %)
352 +(((
353 + [[image:image-20220714162725-6.png]]
354 +)))
129 129  
356 +(% class="wikigeneratedid" id="HConfiguredevicenetwork" %)
357 +(((
358 +**2)Configure device network**
359 +)))
130 130  
131 -=== **Configure device network** ===
132 -
133 133  (((
362 +(((
363 +(((
134 134  Click the Configuration Download button[[image:image-20220714115308-8.png||height="22" width="15"]], It is used to configure the device network, update the device time, obtain the device machine code, check the device network, etc.
135 135  )))
136 136  
137 137  (((
138 -In the example below, the IP address of V-Box is configured as 192.168.40.66, and the networking method is 4G connection.
368 +In the example below, the IP address of V-Box is configured as 192.168.40.66, and the networking method is 4G connection
139 139  )))
140 -
141 - [[image:image-20220714115440-9.png||height="425" width="791"]]
142 142  )))
143 143  )))
144 144  
145 -== **V-net add device** ==
373 +(((
374 +(((
375 +[[image:image-20220714162737-7.png]]
376 +
377 +
146 146  )))
379 +)))
380 +)))
381 +)))
147 147  
383 +(% class="wikigeneratedid" id="HV-netadddevice" %)
148 148  (((
149 -Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device. 
385 +**3)V-net add device**
150 150  )))
387 +)))
151 151  
152 152  (((
153 - [[image:image-20220714115640-10.png||height="430" width="797"]]
390 +(((
391 +Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device.   [[image:image-20220714162752-8.png]]
154 154  )))
155 155  
156 -(((
157 157  
158 158  )))
159 159  
160 160  (((
161 -=== **Set communication port parameters** ===
398 +(% class="wikigeneratedid" id="HSetcommunicationportparameters" %)
399 +(((
400 +**4)Set communication port parameters**
401 +)))
162 162  
403 +(((
163 163  In the device list on the left, find the Vbox that communicates with the L1769, click it and select configuration,communication port configuration in the main interface to add a communication protocol.
405 +)))
164 164  
165 - [[image:image-20220714115848-11.png||height="432" width="802"]]
407 +[[image:image-20220714162805-9.png]]
166 166  )))
167 167  
168 -
410 +(((
169 169  The communication port is selected as Ethernet, the device type is selected as Allen-Bradley, the protocol is Allen-BradleyMicro850_FreeTag EthemetIP, and the IP is the internal IP address of the L1769 PLC. The port number is 44818.
412 +)))
170 170  
171 -[[image:image-20220714143820-1.png]]
414 +[[image:image-20220714162814-10.png]]
172 172  
173 -After adding the protocol Allen-BradleyMicro850_FreeTag, click[[image:image-20220714143838-2.png]]icon add label.
174 174  
175 -[[image:image-20220714143849-3.png]]
417 +(((
418 +After adding the protocol Allen-BradleyMicro850_FreeTag, click[[image:image-20220714143838-2.png]]icon add label.[[image:image-20220714162827-11.png]]
419 +)))
176 176  
421 +(% class="wikigeneratedid" id="HEngineeringproduction" %)
422 +(((
423 +**5)Engineering production**
424 +)))
177 177  
178 -== Engineering production ==
426 +(% class="wikigeneratedid" %)
427 +(((
428 +(((
429 +According to your own needs, use the V-NET client software to edit the required data monitoring points.
430 +)))
179 179  
432 +[[image:image-20220714162841-12.png]]
180 180  
181 -== **Siemens S7-1200** ==
182 182  
183 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]]
435 +(((
436 +**hardware connection**
437 +)))
438 +)))
184 184  
440 +(((
441 +**1)Hardware wiring diagram**
442 +)))
443 +
444 +(((
445 +(((
446 +This example introduces Wecon V-box with Allen-Bradley L1769 PLC to establish communication through Ethernet. The connection diagram is as follows:
447 +)))
448 +
449 +[[image:image-20220714162856-13.png]]
450 +
451 +(((
452 +The above are all the steps for establishing Ethernet communication between Wecon V-box with Allen-Bradley L1769 PLC.
453 +
454 +
185 185  == **Allen-Bradley Ethernet DF1** ==
186 186  
187 187  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]]
188 188  
459 +
460 += **Siemens PLC** =
461 +)))
462 +)))
463 +
464 +== **Siemens S7-1200** ==
465 +
466 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]]
467 +
189 189  == **Communication with S7-200 Smart** ==
190 190  
191 191  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]]
192 192  
472 += **Delta PLC** =
473 +
193 193  == **Delta DVP Ethernet** ==
194 194  
195 195  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
... ... @@ -216,7 +216,7 @@
216 216  
217 217  = **2 User define protocol** =
218 218  
219 -More serial port script instruction,please refer manual:[[Lua script function>>doc:V-BOX.V-Net.1\.User Manual.04 Lua Script.01 Lua Functions.WebHome]]~-~-->[[3.Serial port operation>>url:http://docs.we-con.com.cn/wiki/vbox/view/HMI/04.Lua%20script%20%20function%20and%20operation/01.Lua%20script%20function/#H3.Serialportoperation]]
500 +More serial port script instruction,please refer manual:[[Lua script function>>doc:V-BOX.V-Net.Manual.04 Lua Script.01 Lua Functions.WebHome]]~-~-->[[3.Serial port operation>>url:http://docs.we-con.com.cn/wiki/vbox/view/HMI/04.Lua%20script%20%20function%20and%20operation/01.Lua%20script%20function/#H3.Serialportoperation]]
220 220  
221 221  == **Read the temperature sensor.** ==
222 222  
image-20220714160006-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +1.3 MB
Content
image-20220714160034-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +135.2 KB
Content
image-20220714160120-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +58.8 KB
Content
image-20220714160335-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +264.1 KB
Content
image-20220714160412-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +58.5 KB
Content
image-20220714160439-6.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +104.0 KB
Content
image-20220714160541-7.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +13.7 KB
Content
image-20220714160651-8.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +135.2 KB
Content
image-20220714160843-9.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +165.9 KB
Content
image-20220714160943-10.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +50.2 KB
Content
image-20220714161014-11.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +94.3 KB
Content
image-20220714161120-12.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +94.3 KB
Content
image-20220714161229-13.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +62.5 KB
Content
image-20220714161445-14.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +131.2 KB
Content
image-20220714162600-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +58.8 KB
Content
image-20220714162617-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +1.3 MB
Content
image-20220714162629-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +58.5 KB
Content
image-20220714162652-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +58.5 KB
Content
image-20220714162713-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +104.0 KB
Content
image-20220714162725-6.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +13.7 KB
Content
image-20220714162737-7.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +135.2 KB
Content
image-20220714162752-8.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +135.2 KB
Content
image-20220714162805-9.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +165.9 KB
Content
image-20220714162814-10.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +50.2 KB
Content
image-20220714162827-11.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +94.3 KB
Content
image-20220714162841-12.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +62.5 KB
Content
image-20220714162856-13.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +131.6 KB
Content