Changes for page 1 Communication

Last modified by Hunter on 2024/07/01 10:54

From version 14.1
edited by Ben
on 2022/07/14 14:39
Change comment: There is no comment for this version
To version 43.1
edited by Ben
on 2022/08/24 11:27
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,7 +1,5 @@
1 -= **1 General communication with PLC** =
1 += **Modbus RTU** =
2 2  
3 -== **Modbus RTU** ==
4 -
5 5  === **V-BOX as master** ===
6 6  
7 7  Select the protocol “(% class="mark" %)Modbus RTU Slave(All Fuction)”,
... ... @@ -47,73 +47,332 @@
47 47  |(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils)
48 48  |0F (Write multiple bits)
49 49  
50 -== **WECON LX3V PLC** ==
48 += **WECON PLC** =
51 51  
52 -Select the protocol (% class="mark" %)"WECON LX3V"
50 +== **维控 LX3V 串行通信** ==
53 53  
54 -(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity same with PLC.
52 +Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM
55 55  
56 -(% class="mark" %)WECON PLC RS422 port,default communication parameters is 9600,1,7,ZEVEN
54 +**HMI Settings**
57 57  
56 +|**Item**|**Settings**|**Note**
57 +|Protocol|WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM|
58 +|Connection|RS422/RS485|
59 +|Baud rate|9600|
60 +|Data bit|7|
61 +|Parity|EVEN|
62 +|Stop bit|1|
63 +|PLC station No.|1|
64 +
65 +**Address List**
66 +
67 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
68 +|(% rowspan="6" %)Bit|X|X|Xo|0~~303237|
69 +|Y|Y|Y o|0~~303237|
70 +|M|M|M d|0~~99999|
71 +|T|T|T d|0~~99999|
72 +|C|C|C d|0~~99999|
73 +|S|S|S d|0~~99999|
74 +|(% rowspan="8" %)Word|X|X|Xo|0~~303237|
75 +|Y|Y|Y o|0~~303237|
76 +|M|M|M d|0~~99999|
77 +|T|T|T d|0~~99999|
78 +|C|C|C d|0~~199|
79 +|D|D|D d|0~~7999|
80 +|S|S|S d|0~~99999|
81 +|SD|SD|SD d|8000~~9999|
82 +
83 +**Cable Wiring**
84 +
85 +* **RS485**
86 +
87 + [[image:image-20220822172124-1.png]]
88 +
89 +* **RS422**
90 +
91 + [[image:image-20220822172228-2.png]]
92 +
93 +
94 +**✎Note:**
95 +
96 +* HMI COM3 is available in PI8000 series and COM3 is in COM2(hardware PIN 7 and PIN 8) .
97 +* If PLC <= 20 points,such as LX3V-1208/LX3V-0806 PLC,PLC RS485A and RS485B mean PLC COM2 RS485+ and RS485- .PLC COM2 can support modbus. Please refer to PLC COM2 setting manual.
98 +
99 +[[https:~~/~~/drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing>>url:https://drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing]]
100 +
101 +== **LX5V serial communication** ==
102 +
103 +This example introduces the establishment of serial port communication between Wecon V-BOX and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
104 +
105 +**Software configuration of PLC**
106 +
107 +**1)PLC programming software**
108 +
109 +[[image:image-20220822172553-1.png]]
110 +
111 +**2)New PLC project**
112 +
113 +Click New Project and select the PLC model.
114 +
115 +[[image:image-20220822172623-2.png]]
116 +
117 +**3)Set Serial port parameters**
118 +
119 +Follow the steps below to configure Serial port parameters
120 +
121 +Baud rate:115200
122 +
123 +Data bit:8
124 +
125 +Stop bit:1
126 +
127 +Parity:No verification
128 +
129 +[[image:image-20220822172657-3.png]]
130 +
131 +**4)Registers list**
132 +
133 +[[image:image-20220822172730-4.png]]
134 +
135 +**V-BOX software configuration**
136 +
137 +**1)V-BOX programming software**
138 +
139 + [[image:image-20220824104124-1.png]]
140 +
141 +**2)V-NET add device**
142 +
143 +Open V-NET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the access key, password and remark, to add the device.
144 +
145 +[[image:image-20220824104909-2.png]]
146 +
147 +
148 +**3)Set communication port parameters**
149 +
150 +Click the communication configuration button on the left to find the communication protocol with LX5V. After selecting the protocol, configure the communication parameters of the COM port.
151 +
152 +Baud rate:115200
153 +
154 +Data bit:8
155 +
156 +Stop bit:1
157 +
158 +Parity:No verification
159 +
160 +[[image:image-20220811104012-1.png]]
161 +
162 +
163 +**hardware connection**
164 +
165 +**1)Hardware wiring diagram**
166 +
167 +This example introduces WeconHMI with LX5V PLC to establish communication through serial port. The connection diagram is as follows:
168 +
169 +
170 +
171 +[[image:image-20220811103005-4.png]]
172 +
173 +[[image:image-20220811103227-7.png]]
174 +
175 +The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC.
176 +
177 +== **V-BOX and Wecon LX5V-N Ethernet communication** ==
178 +
179 + This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
180 +
181 +**Software configuration of PLC**
182 +
183 +**1)PLC programming software**
184 +
185 +[[image:image-20220810164710-1.png]]
186 +
187 +**2)New PLC project**
188 +
189 +Click New Project and select the PLC model.
190 +
191 +[[image:image-20220811115454-1.png]]
192 +
193 +**3)Set Ethernet port parameters**
194 +
195 +Follow the steps below to configure Ethernet parameters
196 +
197 +PLC IP address:192.168.39.200
198 +
199 +default gateway:192.168.39.1
200 +
201 +subnet mask:255.255.255.0
202 +
203 +[[image:image-20220811140530-2.png]]
204 +
205 +**4)Registers list**
206 +
207 +[[image:image-20220811102219-3.png]]
208 +
209 +**HMI software configuration**
210 +
211 +**1)HMI programming software**
212 +
213 + [[image:image-20220810171237-4.png]]
214 +
215 +**2)New HMI project**
216 +
217 +Click New Project and select the HMI model.
218 +
219 +[[image:image-20220810172010-5.png]]
220 +
221 +**3)Set communication port parameters**
222 +
223 +Click the project setting button on the left to configure the IP address of the HMI machine to ensure that the HMI and PLC IP remain in a local area network.
224 +
225 +HMI IP address:192.168.39.201
226 +
227 +default gateway:192.168.39.1
228 +
229 +subnet mask:255.255.255.0
230 +
231 +[[image:image-20220811170753-2.png]]
232 +
233 +Next, click Communication Settings to configure the IP of the HMI communication object.
234 +
235 +[[image:image-20220811163047-1.png]]
236 +
237 +**hardware connection**
238 +
239 +**1)Hardware wiring diagram**
240 +
241 +This example introduces WeconHMI with LX5V-N PLC to establish communication through ethernet. The connection diagram is as follows:
242 +
243 +[[image:image-20220811170248-1.png]]
244 +
245 +The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC.
246 +
58 58  (% style="text-align:center" %)
59 59  [[image:1624348978863-771.png||queryString="width=812&height=494" height="487" width="800" class="img-thumbnail"]]
60 60  
61 -== **2 Communication with Allen-Bradley CompactLogix L1769** ==
250 += **Rockwell PLC** =
62 62  
252 +
253 +== (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix** ==
254 +
255 +MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
256 +
257 +**HMI Settings**
258 +
259 +|**Item**|**Settings**|**Note**
260 +|Protocol|Allen-Bradlley MicroLogix|
261 +|Connection|RS232|
262 +|Baud rate|19200|
263 +|Data bit|8|
264 +|Parity|None|
265 +|Stop bit|1|
266 +|PLC station No.|1|
267 +
268 +**Address List**
269 +
270 +|**Type**|**Device registers**|**Format**|**Range**|**Note**
271 +|(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15|
272 +|O|O d.d|0.0~~255.15|
273 +|B|B nnhh.dd|0.0~~ffff.15|nn: block number (hex)
274 +|S|S d.d|0.0~~255.15|
275 +|N|N nnhh.dd|0.0~~ffff.15|nn: block number (hex)
276 +|(% rowspan="9" %)Word|S|S d|0~~255|
277 +|TS|TS nnhh|0~~ffff|(% rowspan="8" %)nn: block number (hex)
278 +|TP|TP nnhh|0~~ffff
279 +|CS|CS nnhh|0~~ffff
280 +|CP|CP nnhh|0~~ffff
281 +|N|N nnhh|0~~ffff
282 +|C|C nnhh|0~~ffff
283 +|T|T nnhh|0~~ffff
284 +|R|R nnhh|0~~ffff
285 +
286 +**Cable Wiring**
287 +
288 +[[image:image-20220824110724-1.png]]
289 +
290 +
291 +
292 +== **CompactLogix** ==
293 +
63 63  (((
64 -This example introduces the establishment of Ethernet communication between Wecon V-box and Allen-Bradley L1769. It is introduced through three parts: PLC software configuration, V-box software configuration, and hardware wiring.
295 +(((
296 +This example introduces the establishment of Ethernet communication between Wecon V-box and CompactLogix L1769. It is introduced through three parts: PLC software configuration, V-box software configuration, and hardware wiring.
65 65  )))
298 +)))
66 66  
67 67  (((
68 -
301 +(% class="wikigeneratedid" id="HSoftwareconfigurationofPLC" %)
302 +(((
303 +**Software configuration of PLC**
69 69  )))
70 70  
306 +(% class="wikigeneratedid" id="HPLCprogrammingsoftware" %)
71 71  (((
72 -== **Software configuration of PLC** ==
308 +**1)PLC programming software**
309 +)))
73 73  
74 -=== **PLC programming software** ===
311 +[[image:image-20220714162600-1.png]]
75 75  
76 - [[image:image-20220714113935-3.png]]
77 -
78 -=== **New PLC project** ===
79 -
313 +(% class="wikigeneratedid" id="HNewPLCproject" %)
80 80  (((
81 -Click New Project and select the PLC model.
315 +**2)New PLC project**
82 82  )))
83 83  
84 84  (((
85 - [[image:image-20220714114247-4.png]]
319 +(((
320 +Click New Project and select the PLC model.
86 86  )))
322 +)))
87 87  
88 88  (((
89 - [[image:image-20220714114257-5.png]]
325 +[[image:image-20220714162617-2.png]]
90 90  )))
91 91  
92 92  (((
93 93  
330 +
331 +[[image:image-20220714162652-4.png]]
94 94  )))
95 95  
96 96  (((
97 -=== **Set Ethernet parameters** ===
335 +(% class="wikigeneratedid" id="HSetEthernetparameters" %)
336 +(((
337 +**3)Set Ethernet parameters**
338 +)))
98 98  
99 99  (((
341 +(((
342 +(((
100 100  Follow the steps below to configure Ethernet parameters
101 101  )))
345 +)))
346 +)))
102 102  
103 103  (((
349 +(((
350 +(((
104 104  PLC IP address:192.168.40.101
105 105  )))
353 +)))
354 +)))
106 106  
107 107  (((
357 +(((
358 +(((
108 108  default gateway:192.168.40.1
109 109  )))
361 +)))
362 +)))
110 110  
111 111  (((
365 +(((
366 +(((
112 112  subnet mask:255.255.255.0
113 113  )))
369 +)))
370 +)))
114 114  
115 115  (((
116 - [[image:image-20220714115012-6.png]]
373 +[[image:image-20220714162713-5.png]]
117 117  )))
118 118  
119 119  (((
... ... @@ -121,75 +121,139 @@
121 121  )))
122 122  
123 123  (((
124 -== **V-box software configuration** ==
381 +(% class="wikigeneratedid" id="HV-boxsoftwareconfiguration" %)
382 +(((
383 +**V-box software configuration**
384 +)))
125 125  
126 -=== **V-box programming software** ===
386 +(% class="wikigeneratedid" id="HV-boxprogrammingsoftware" %)
387 +(((
388 +**1)V-box programming software**
389 +)))
127 127  
128 - [[image:image-20220714115214-7.png]]
391 +(% class="wikigeneratedid" %)
392 +(((
393 + [[image:image-20220714162725-6.png]]
394 +)))
129 129  
396 +(% class="wikigeneratedid" id="HConfiguredevicenetwork" %)
397 +(((
398 +**2)Configure device network**
399 +)))
130 130  
131 -=== **Configure device network** ===
132 -
133 133  (((
402 +(((
403 +(((
134 134  Click the Configuration Download button[[image:image-20220714115308-8.png||height="22" width="15"]], It is used to configure the device network, update the device time, obtain the device machine code, check the device network, etc.
135 135  )))
136 136  
137 137  (((
138 -In the example below, the IP address of V-Box is configured as 192.168.40.66, and the networking method is 4G connection.
408 +In the example below, the IP address of V-Box is configured as 192.168.40.66, and the networking method is 4G connection
139 139  )))
140 -
141 - [[image:image-20220714115440-9.png||height="425" width="791"]]
142 142  )))
143 143  )))
144 144  
145 -== **V-net add device** ==
413 +(((
414 +(((
415 +[[image:image-20220714162737-7.png]]
416 +
417 +
146 146  )))
419 +)))
420 +)))
421 +)))
147 147  
423 +(% class="wikigeneratedid" id="HV-netadddevice" %)
148 148  (((
149 -Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device. 
425 +**3)V-net add device**
150 150  )))
427 +)))
151 151  
152 152  (((
153 - [[image:image-20220714115640-10.png||height="430" width="797"]]
430 +(((
431 +Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device.   [[image:image-20220714162752-8.png]]
154 154  )))
155 155  
156 -(((
157 157  
158 158  )))
159 159  
160 160  (((
161 -=== **Set communication port parameters** ===
438 +(% class="wikigeneratedid" id="HSetcommunicationportparameters" %)
439 +(((
440 +**4)Set communication port parameters**
441 +)))
162 162  
443 +(((
163 163  In the device list on the left, find the Vbox that communicates with the L1769, click it and select configuration,communication port configuration in the main interface to add a communication protocol.
445 +)))
164 164  
165 - [[image:image-20220714115848-11.png||height="432" width="802"]]
447 +[[image:image-20220714162805-9.png]]
166 166  )))
167 167  
168 -
450 +(((
169 169  The communication port is selected as Ethernet, the device type is selected as Allen-Bradley, the protocol is Allen-BradleyMicro850_FreeTag EthemetIP, and the IP is the internal IP address of the L1769 PLC. The port number is 44818.
452 +)))
170 170  
171 -[[image:image-20220714143820-1.png]]
454 +[[image:image-20220714162814-10.png]]
172 172  
173 -After adding the protocol Allen-BradleyMicro850_FreeTag, click[[image:image-20220714143838-2.png]]icon add label.
174 174  
175 -[[image:image-20220714143849-3.png]]
457 +(((
458 +After adding the protocol Allen-BradleyMicro850_FreeTag, click[[image:image-20220714143838-2.png]]icon add label.[[image:image-20220714162827-11.png]]
459 +)))
176 176  
461 +(% class="wikigeneratedid" id="HEngineeringproduction" %)
462 +(((
463 +**5)Engineering production**
464 +)))
177 177  
178 -== Engineering production ==
466 +(% class="wikigeneratedid" %)
467 +(((
468 +(((
469 +According to your own needs, use the V-NET client software to edit the required data monitoring points.
470 +)))
179 179  
472 +[[image:image-20220714162841-12.png]]
180 180  
181 -== **Siemens S7-1200** ==
182 182  
183 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]]
475 +(((
476 +**hardware connection**
477 +)))
478 +)))
184 184  
480 +(((
481 +**1)Hardware wiring diagram**
482 +)))
483 +
484 +(((
485 +(((
486 +This example introduces Wecon V-box with Allen-Bradley L1769 PLC to establish communication through Ethernet. The connection diagram is as follows:
487 +)))
488 +
489 +[[image:image-20220714162856-13.png]]
490 +
491 +(((
492 +The above are all the steps for establishing Ethernet communication between Wecon V-box with CompactLogix L1769 PLC.
493 +
494 +
185 185  == **Allen-Bradley Ethernet DF1** ==
186 186  
187 187  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]]
188 188  
499 +
500 += **Siemens PLC** =
501 +)))
502 +)))
503 +
504 +== **Siemens S7-1200** ==
505 +
506 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]]
507 +
189 189  == **Communication with S7-200 Smart** ==
190 190  
191 191  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]]
192 192  
512 += **Delta PLC** =
513 +
193 193  == **Delta DVP Ethernet** ==
194 194  
195 195  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
... ... @@ -216,7 +216,7 @@
216 216  
217 217  = **2 User define protocol** =
218 218  
219 -More serial port script instruction,please refer manual:[[Lua script function>>doc:V-BOX.V-Net.1\.User Manual.04 Lua Script.01 Lua Functions.WebHome]]~-~-->[[3.Serial port operation>>url:http://docs.we-con.com.cn/wiki/vbox/view/HMI/04.Lua%20script%20%20function%20and%20operation/01.Lua%20script%20function/#H3.Serialportoperation]]
540 +More serial port script instruction,please refer manual:[[Lua script function>>doc:V-BOX.V-Net.Manual.04 Lua Script.01 Lua Functions.WebHome]]~-~-->[[3.Serial port operation>>url:http://docs.we-con.com.cn/wiki/vbox/view/HMI/04.Lua%20script%20%20function%20and%20operation/01.Lua%20script%20function/#H3.Serialportoperation]]
220 220  
221 221  == **Read the temperature sensor.** ==
222 222  
image-20220714160006-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +1.3 MB
Content
image-20220714160034-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +135.2 KB
Content
image-20220714160120-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +58.8 KB
Content
image-20220714160335-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +264.1 KB
Content
image-20220714160412-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +58.5 KB
Content
image-20220714160439-6.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +104.0 KB
Content
image-20220714160541-7.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +13.7 KB
Content
image-20220714160651-8.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +135.2 KB
Content
image-20220714160843-9.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +165.9 KB
Content
image-20220714160943-10.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +50.2 KB
Content
image-20220714161014-11.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +94.3 KB
Content
image-20220714161120-12.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +94.3 KB
Content
image-20220714161229-13.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +62.5 KB
Content
image-20220714161445-14.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +131.2 KB
Content
image-20220714162600-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +58.8 KB
Content
image-20220714162617-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +1.3 MB
Content
image-20220714162629-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +58.5 KB
Content
image-20220714162652-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +58.5 KB
Content
image-20220714162713-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +104.0 KB
Content
image-20220714162725-6.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +13.7 KB
Content
image-20220714162737-7.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +135.2 KB
Content
image-20220714162752-8.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +135.2 KB
Content
image-20220714162805-9.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +165.9 KB
Content
image-20220714162814-10.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +50.2 KB
Content
image-20220714162827-11.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +94.3 KB
Content
image-20220714162841-12.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +62.5 KB
Content
image-20220714162856-13.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +131.6 KB
Content
image-20220820164423-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +18.4 KB
Content
image-20220822172124-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +38.7 KB
Content
image-20220822172228-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +48.8 KB
Content
image-20220822172553-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +19.9 KB
Content
image-20220822172623-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +111.2 KB
Content
image-20220822172657-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +141.6 KB
Content
image-20220822172730-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +130.7 KB
Content
image-20220824104124-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +14.6 KB
Content
image-20220824104909-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +278.8 KB
Content
image-20220824110724-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +79.1 KB
Content