Changes for page 1 Communication

Last modified by Hunter on 2024/07/01 10:54

From version 143.1
edited by Ben
on 2022/08/31 16:10
Change comment: There is no comment for this version
To version 147.1
edited by Ben
on 2022/08/31 16:26
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1133,7 +1133,7 @@
1133 1133  [[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]]
1134 1134  
1135 1135  
1136 -== **EC55 Protocol** ==
1136 +== **EC55 Series Protocol** ==
1137 1137  
1138 1138  Supported device: EC55 temperature instrument
1139 1139  
... ... @@ -1192,8 +1192,496 @@
1192 1192  * Because of the mechanism problem, this protocol could not support CompoWay/F function that is read-write function of variables in protocol document.
1193 1193  * When using double-word address, set the data format to 32 bits, otherwise the read/write function is unable.
1194 1194  * Please set the communication delay time of 10ms in setting, to avoid that the instrument may not be able to communicate in a short time due to too fast data access and too much connection requests.
1195 -* [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_d428cad280fdefb3.png?width=347&height=276&rev=1.1||alt="12.PLC Protocol_html_d428cad280fdefb3.png" height="276" width="347"]]Because of the particularity of the instrument, it is necessary to write the value of the address in the menu interface corresponding to the address, and to enter the menu where the address locates, so that the value could be written.
1195 +* [[image:image-20220831161356-1.png]]Because of the particularity of the instrument, it is necessary to write the value of the address in the menu interface corresponding to the address, and to enter the menu where the address locates, so that the value could be written.
1196 1196  
1197 += Create communication with Xinje** PLC**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=34]] =
1198 +
1199 +== **XC serial protocol**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=35]] ==
1200 +
1201 +**1)HMI Settings**
1202 +
1203 +|**Item**|**Settings**|**Note**
1204 +|Protocol|XINJE XC MODBUS|
1205 +|Connection|RS232|
1206 +|Baud rate|19200|
1207 +|Data bit|8|
1208 +|Parity|EVEN|
1209 +|Stop bit|1|
1210 +|PLC station No.|1|
1211 +
1212 +**2)Address List**
1213 +
1214 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1215 +|Bit|M|M|M d|0~~8511|
1216 +|Bit|X|X|X o|0~~1747|
1217 +|Bit|Y|Y|Y o|0~~1747|
1218 +|Bit|S|S|S d|0~~1023|
1219 +|Bit|T|T|T d|0~~4095|
1220 +|Bit|C|C|C d|0~~634|
1221 +|Word|D|D|D d|0~~8511|
1222 +|Word|TD|TD|TD d|0~~618|
1223 +|Word|CD|CD|CD d|0~~634|
1224 +|Word|FD|FD|FD d|0~~8511|
1225 +
1226 +**3)Configure the communication protocol**
1227 +
1228 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830154105-1.png?rev=1.1||alt="image-20220830154105-1.png"]]
1229 +
1230 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830154159-3.png?rev=1.1||alt="image-20220830154159-3.png"]]
1231 +
1232 +**4)Cable Wiring**
1233 +
1234 +Figure
1235 +
1236 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830155728-4.png?rev=1.1||alt="image-20220830155728-4.png"]]
1237 +
1238 +Pin Definition Diagram
1239 +
1240 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830154131-2.png?rev=1.1||alt="image-20220830154131-2.png"]]
1241 +
1242 +== **XD serial protocol**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=36]] ==
1243 +
1244 +**1)HMI Settings**
1245 +
1246 +Supported Series: Delta Xinjie XD/XE Series PLC
1247 +
1248 +|**Item**|**Settings**|**Note**
1249 +|Protocol|XINJE XD/XC MODBUS|
1250 +|Connection|RS232|
1251 +|Baud rate|19200|
1252 +|Data bit|8|
1253 +|Parity|EVEN|
1254 +|Stop bit|1|
1255 +|PLC station No.|1|
1256 +
1257 +**2)Address List**
1258 +
1259 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1260 +|Bit|M|M|M d|0~~74999|
1261 +|Bit|X1xx|X1xx|X1xx o|0~~1177|
1262 +|Bit|X2xx|X2xx|X2xx o|0~~277|
1263 +|Bit|X|X|X o|0~~77|
1264 +|Bit|Y1xx|Y1xx|Y1xx o|0~~1177|
1265 +|Bit|Y2xx|Y2xx|Y2xx o|0~~277|
1266 +|Bit|Y|Y|Y o|0~~4095|
1267 +|Bit|SM|SM|SM d|0~~4999|(((
1268 +
1269 +)))
1270 +|Bit|T|T|T d|0~~4999|
1271 +|Bit|C|C|C d|0~~4999|
1272 +|Bit|ET|ET|ET d|0~~31|
1273 +|Bit|SE|SE|SE d|0~~31|
1274 +|Bit|HM|HM|HM d|0~~11999|
1275 +|Bit|HSC|HSC|HSC d|0~~39|
1276 +|Bit|HS|HS|HS d|0~~999|
1277 +|Bit|HT|HT|HT d|0~~1999|
1278 +|Bit|HC|HC|HC d|0~~1999|
1279 +|Bit|S|S|S d|0~~7999|
1280 +|Word|D|D|D d|0~~69999|
1281 +|Word|ID|ID|ID d|0~~99|
1282 +|Word|ID1xx|ID1xx|ID1xx d|0~~999|
1283 +|Word|ID2xx|ID2xx|ID2xx d|0~~299|
1284 +|Word|QD|QD|QD d|0~~99|
1285 +|Word|QD1xx|QD1xx|QD1xx d|0~~999|
1286 +|Word|QD2xx|QD2xx|QD2xx d|0~~299|
1287 +|Word|SD|SD|SD d|0~~4999|
1288 +|Word|TD|TD|TD d|0~~575|
1289 +|Word|CD|CD|CD d|0~~575|
1290 +|Word|ETD|ETD|ETD d|0~~31|
1291 +|Word|HD|HD|HD d|0~~24999|
1292 +|Word|HSD|HSD|HSD d|0~~1023|
1293 +|Word|HTD|HTD|HTD d|0~~95|
1294 +|Word|HCD|HCD|HCD d|0~~95|
1295 +|Word|HSCD|HSCD|HSCD d|0~~31|
1296 +|Word|FD|FD|FD d|0~~8191|
1297 +|Word|SFD|SFD|SFD d|0~~5999|
1298 +|Word|FS|FS|FS d|0~~47|
1299 +
1300 +**3)Configure the communication protocol**
1301 +
1302 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830160042-1.png?rev=1.1||alt="image-20220830160042-1.png"]]
1303 +
1304 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830160129-2.png?rev=1.1||alt="image-20220830160129-2.png"]]
1305 +
1306 +**4)Cable Wiring**
1307 +
1308 +Figure
1309 +
1310 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830160257-4.png?rev=1.1||alt="image-20220830160257-4.png"]]
1311 +
1312 +Pin Definition Diagram
1313 +
1314 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830160232-3.png?rev=1.1||alt="image-20220830160232-3.png"]]
1315 +
1316 += Create communication with Inovance** PLC**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=37]] =
1317 +
1318 +== **H3U serial protocol**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=38]] ==
1319 +
1320 +**1)HMI Settings**
1321 +
1322 +|**Item**|**Settings**|**Note**
1323 +|Protocol|INOVANCE H3U PLC|
1324 +|Connection|RS22|
1325 +|Baud rate|9600|
1326 +|Data bit|7|
1327 +|Parity|EVEN|
1328 +|Stop bit|1|
1329 +|PLC station No.|0|
1330 +
1331 +**2)Address List**
1332 +
1333 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1334 +|Bit|X|X|X o|0~~303237|
1335 +|Bit|Y|Y|Y o|0~~303237|
1336 +|Bit|M|M|M d|0~~99999|
1337 +|Bit|T|T|T d|0~~99999|
1338 +|Bit|C|C|C d|0~~99999|
1339 +|Bit|SM|SM|SM d|8000~~999|
1340 +|Bit|S|T|S d|0~~99999|
1341 +|Bit|Lamp|Lamp|Lamp d|0~~0|
1342 +|Word|X|X|X o|0~~303237|
1343 +|Word|Y|Y|Y o|0~~303237|
1344 +|Word|M|M|M d|0~~99999|
1345 +|Word|T|T|T d|0~~99999|
1346 +|Word|C|C|C d|0~~199|
1347 +|Word|D|D|D d|0~~7999|
1348 +|Word|S|S|S d|0~~99999|
1349 +|Word|SD|SD|SD d|8000~~9999|
1350 +|Word|R|R|R d|0~~32767|
1351 +
1352 +**3)Configure the communication protocol**
1353 +
1354 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830170114-4.png?rev=1.1||alt="image-20220830170114-4.png"]]
1355 +
1356 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830170017-3.png?rev=1.1||alt="image-20220830170017-3.png"]]
1357 +
1358 +**4)Cable Wiring**
1359 +
1360 +Figure
1361 +
1362 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830165930-1.png?rev=1.1||alt="image-20220830165930-1.png"]]
1363 +
1364 +Pin Definition Diagram
1365 +
1366 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830165947-2.png?rev=1.1||alt="image-20220830165947-2.png"]]
1367 +
1368 += Create communication with Panasonic** PLC**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=39]] =
1369 +
1370 +== **FP serial protocol**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=40]] ==
1371 +
1372 +**1)HMI Settings**
1373 +
1374 +|**Item**|**Settings**|**Note**
1375 +|Protocol|Panasonic FP MFWTOCOL|
1376 +|Connection|RS232|
1377 +|Baud rate|9600|
1378 +|Data bit|8|
1379 +|Parity|ODD|
1380 +|Stop bit|1|
1381 +|PLC station No.|1|
1382 +
1383 +**2)Address List**
1384 +
1385 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1386 +|Bit|X|X|X d|0~~9999|
1387 +|Bit|Y|Y|Y d|0~~9999|
1388 +|Bit|R|R|R d|0~~9999|
1389 +|Bit|T|T|T d|0~~9999|
1390 +|Bit|C|C|C d|0~~9999|
1391 +|Bit|L|L|L d|0~~9999|
1392 +|Word|WX|WX|WX d|0~~9999|
1393 +|Word|WY|WY|WY d|0~~9999|
1394 +|Word|WR|WR|WR d|0~~9999|
1395 +|Word|WL|WL|WL d|0~~9999|
1396 +|Word|LD|LD|LD d|0~~9999|
1397 +|Word|DT|DT|DT d|0~~65535|
1398 +|Word|FL|FL|FL d|0~~9999|
1399 +|Word|EV|EV|EV d|0~~9999|
1400 +|Word|SV|SV|SV d|0~~9999|
1401 +
1402 +**3)Configure the communication protocol**
1403 +
1404 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830171050-1.png?rev=1.1||alt="image-20220830171050-1.png"]]
1405 +
1406 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830171126-2.png?rev=1.1||alt="image-20220830171126-2.png"]]
1407 +
1408 +**4)Cable Wiring**
1409 +
1410 +Figure
1411 +
1412 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830171328-4.png?rev=1.1||alt="image-20220830171328-4.png"]]
1413 +
1414 +Pin Definition Diagram
1415 +
1416 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830171146-3.png?rev=1.1||alt="image-20220830171146-3.png"]]
1417 +
1418 += Create communication with LS** PLC**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=41]] =
1419 +
1420 +== **XBC serial protocol**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=42]] ==
1421 +
1422 +**1)HMI Settings**
1423 +
1424 +|**Item**|**Settings**|**Note**
1425 +|Protocol|LS XBC CNet|
1426 +|Connection|RS232|
1427 +|Baud rate|115200|
1428 +|Data bit|8|
1429 +|Parity|NONE|
1430 +|Stop bit|1|
1431 +|PLC station No.|1|
1432 +
1433 +**2)Address List**
1434 +
1435 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1436 +|Bit|P|P|P d|0~~2047|
1437 +|Bit|M|M|M d|0~~2047|
1438 +|Bit|L|L|L d|0~~11263|
1439 +|Bit|K|K|K d|0~~16183|
1440 +|Bit|F|F|F d|0~~2047|
1441 +|Bit|D|D|D d|0~~32767|
1442 +|Bit|R|R|R d|0~~32767|
1443 +|Bit|U|U|U d|0~~4095|
1444 +|Word|P|P|P d|0~~2047|
1445 +|Word|M|M|M d|0~~2047|
1446 +|Word|L|L|L d|0~~11263|
1447 +|Word|K|K|K d|0~~16183|
1448 +|Word|F|F|F d|0~~2047|
1449 +|Word|C|C|C d|0~~2047|
1450 +|Word|T|T|T d|0~~2047|
1451 +|Word|D|D|D d|0~~32767|
1452 +|Word|N|N|N d|0~~21503|
1453 +|Word|R|R|R d|0~~32767|
1454 +|Word|U|U|U d|0~~4095|
1455 +|Word|Z|Z|Z d|0~~127|
1456 +|Word|S|S|S d|0~~127|
1457 +
1458 +**3)Configure the communication protocol**
1459 +
1460 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830174853-3.png?rev=1.1||alt="image-20220830174853-3.png"]]
1461 +
1462 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830174733-2.png?rev=1.1||alt="image-20220830174733-2.png"]]
1463 +
1464 +**4)Cable Wiring**
1465 +
1466 +Figure
1467 +
1468 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830174659-1.png?rev=1.1||alt="image-20220830174659-1.png"]]
1469 +
1470 +Pin Definition Diagram
1471 +
1472 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830173402-8.png?rev=1.1||alt="image-20220830173402-8.png"]]
1473 +
1474 +== **XGK FEnet Ethernet protocol**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=43]] ==
1475 +
1476 +Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module
1477 +
1478 +**HMI Settings**
1479 +
1480 +|**Items**|**Settings**|**Note**
1481 +|Protocol|LG XGK FEnet(Ethernet)|
1482 +|Connection|Ethernet|
1483 +|Port No.|2004|
1484 +
1485 +**Address List**
1486 +
1487 +|**Type**|**Register**|**Range**|**Format**|**Note**
1488 +|(% rowspan="14" %)Word|P|0~~2047|P d|
1489 +|M|0~~2047|M d|
1490 +|K|0~~2047|K d|
1491 +|F|0~~2047|F d|
1492 +|T|0~~2047|T d|
1493 +|C|0~~2047|C d|
1494 +|Z|0~~127|Z d|
1495 +|S|0~~127|S d|
1496 +|L|0~~11263|L d|
1497 +|N|0~~21503|N d|
1498 +|D|0~~32767|D d|
1499 +|R|0~~32767|R d|
1500 +|ZR|0~~65535|ZR d|
1501 +|UxDD|0~~6331|UxDD nndd|nn: 0~~63, dd: 0~~31
1502 +
1503 +**✎Note:**
1504 +
1505 +* In addition to the "UxDD" register, the others correspond to the PLC register one by one. UxDD corresponds to U in the PLC;
1506 +* The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC;
1507 +* All bit registers are in the form of bits in word, and the range is the same as the word register;
1508 +
1509 +**Communication settings in HMI**
1510 +
1511 +Enable HMI Ethernet in [Project Settings];
1512 +
1513 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_43b671f18153910d.png?width=405&height=107&rev=1.1||alt="12.PLC Protocol_html_43b671f18153910d.png" height="107" width="405"]]
1514 +
1515 +Set PLC IP in [Device IP] settings;
1516 +
1517 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_a2a19b5003ad4090.png?width=554&height=189&rev=1.1||alt="12.PLC Protocol_html_a2a19b5003ad4090.png" height="189" width="554"]]
1518 +
1519 +**Cable Wiring**
1520 +
1521 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1522 +
1523 += Create communication with **SHIMADEN PLC**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=44]] =
1524 +
1525 +== **FP23 series protocol**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=45]] ==
1526 +
1527 +Supported series: SHIMADEN FP23 series
1528 +
1529 +**HMI Setting**
1530 +
1531 +|**Items**|**Settings**|**Note**
1532 +|Protocol|SHIMADEN FP23 series|
1533 +|Connection|RS485 (9600, 1, 7, EVEN)|
1534 +|Port No.|None|
1535 +|PLC station No.|0|
1536 +
1537 +**Address List**
1538 +
1539 +|**Device address**|**HMI register**|**Address range**|**Type**
1540 +|0040-0043(HEX)|FP040|100064-200067|Read only
1541 +|0100-010B(HEX)|FP100|100256-200267|Read only
1542 +|0110-0142(HEX)|FP110|100272-200322|Read only
1543 +|0182-0252(HEX)|FP182|100386-200594|Write only
1544 +|0280-0281(HEX)|FP280|100640-200641|Read only
1545 +|0300-030B(HEX)|FP300|100768-200779|Read and write
1546 +|0380-039F(HEX)|FP380|100896-200927|Read and write
1547 +|0400-04D7(HEX)|FP400|101024-201239|Read and write
1548 +|0500-05B0(HEX)|FP500|101280-201456|Read and write
1549 +|0600-0670(HEX)|FP600|101536-201814|Read and write
1550 +|0720-0738(HEX)|FP720|101824-201848|Read and write
1551 +|0800-083F(HEX)|FP800|102048-202111|Read and write
1552 +|0900-0952(HEX)|FP900|102304-202386|Read and write
1553 +| |Ctrl|0-2|
1554 +
1555 +**✎Note:**
1556 +
1557 +* The upper 2 bits of the address of the HMI register are taken as the sub address, and the real address is the last four bits (for example, if the address is 100256, then 10 is the sub address as 1, and 0256 is the real address);
1558 +* The address range in the table is only divided by the start and end addresses, and some of the addresses in the range have no corresponding address in FP23;
1559 +* The Ctrl register is used to store the control group number and BCC check mode.
1560 +
1561 +**Ctrl Register Description**
1562 +
1563 +* The Ctrl register is a special register that does not communicate with the temperature controller. User needs to assign value in the screen according to the settings as in the temperature controller.
1564 +* Ctrl0 indicates the setting of the control character, the valid values are 1, 2, 3 respectively, and the corresponding control group is: STX_ETX_CR , STX_ETX_CR LF and @_:_CR .
1565 +* Ctrl1 indicates the BCC block check mode. The valid value range is 1-4. The corresponding check mode is: 1.ADD, 2.ADD_two's cmp, 3.XOR, 4.None;
1566 +* Ctrl3 reserved
1567 +
1568 +**✎Note:**
1569 +
1570 +After reloading the HMI project or restarting the HMI, HMI will reset the value of ctrl0 and ctrl1 as 1, so user need to set these two values to make it the same as it in the temperature controller, then communication will be normal.
1571 +
1572 +**Cable Wiring**
1573 +
1574 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5e9a81a14106da9e.png?width=392&height=223&rev=1.1||alt="12.PLC Protocol_html_5e9a81a14106da9e.png" height="223" width="392"]]
1575 +
1576 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_1897d92be6948d58.png?width=393&height=223&rev=1.1||alt="12.PLC Protocol_html_1897d92be6948d58.png" height="223" width="393"]]
1577 +
1578 +**✎Note:** COM3 only available in PI8000/PI9000 series.
1579 +
1580 +== **SR90 protocol**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=46]] ==
1581 +
1582 +Supported series: SHIMADEN SR90 series
1583 +
1584 +**HMI Setting**
1585 +
1586 +|**Items**|**Settings**|**Note**
1587 +|Protocol|SHIMADEN SR90 protocol|
1588 +|Connection|RS485 (1200, 1, 7, EVEN)|
1589 +|Port No.|None|
1590 +|PLC station No.|0|
1591 +
1592 +**Address List**
1593 +
1594 +|**Device address**|**HMI register**|**Address range**|**Type**
1595 +|0040-0043 (HEX)|SR040|100064-100067|Read only
1596 +|0100-010A(HEX)|SR0100|100256-100266|Read only
1597 +|0182-018C(HEX)|SR0182|100386-100396|Write only
1598 +|0300-04FE(HEX)|SR0300|100768-101278|Write/read
1599 +|0500-050B(HEX)|SR0500|101280-101291|Write/read
1600 +|0590-0611(HEX)|SR0590|101424-101553|Write/read
1601 +|0701-0709(HEX)|SR0701|101793-101801|Write/read
1602 +| |Ctrl|0-2|~-~-
1603 +
1604 +**✎Note:**
1605 +
1606 +* The upper 2 bits of the address of HMIs are taken as the sub address, and the real address is the last four bits (for example, if the address is 100256, then 10 is the sub address as 1, and 0256 is the real address);
1607 +* The address range in the table is only divided by the start and end addresses, and some of the addresses in the range have no corresponding address in SR90;
1608 +* The Ctrl register is used to store the control group number and BCC check mode. See how to use it below;
1609 +
1610 +**Ctrl Register Description**
1611 +
1612 +* The Ctrl register is a special register that does not communicate with the temperature controller. User needs to assign value in the screen according to the settings as in the temperature controller.
1613 +* Ctrl0 indicates the setting of the control character, the valid values are 1, 2, 3 respectively, and the corresponding control group is: STX_ETX_CR , STX_ETX_CR LF and @_:_CR .
1614 +* Ctrl1 indicates the BCC block check mode. The valid value range is 1-4. The corresponding check mode is: 1.ADD, 2.ADD_two's cmp, 3.XOR, 4.None;
1615 +* Ctrl3 reserved
1616 +
1617 +**✎Note:**
1618 +
1619 +After reloading the HMI project or restarting the HMI, HMI will reset the value of ctrl0 and ctrl1 as 1, so user need to set these two values to make it the same as it in the temperature controller, then communication will be normal.
1620 +
1621 +**Cable Wiring**
1622 +
1623 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5e9a81a14106da9e.png?width=392&height=223&rev=1.1||alt="12.PLC Protocol_html_5e9a81a14106da9e.png" height="223" width="392"]]
1624 +
1625 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_1897d92be6948d58.png?width=393&height=223&rev=1.1||alt="12.PLC Protocol_html_1897d92be6948d58.png" height="223" width="393"]]
1626 +
1627 +**✎Note:** COM3 only available in PI8000/PI9000 series.
1628 +
1629 +== **MR13 series(standard protocol)**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=47]] ==
1630 +
1631 +Supported series: SHIMADEN MR13 series
1632 +
1633 +**HMI Setting**
1634 +
1635 +|**Items**|**Settings**|**Note**
1636 +|Protocol|SHIMADEN standard protocol|
1637 +|Connection|RS485 (1200, 1, 7, EVEN)|
1638 +|Port No.|None|
1639 +|PLC station No.|0|
1640 +
1641 +**Address List**
1642 +
1643 +|**Device address**|**HMI register**|**Address range**|**Type**
1644 +|0100-010B(HEX)|MR100|100256-300267|Read only
1645 +|0111-0126(HEX)|MR111|100273-300294|Read only
1646 +|0184-0192(HEX)|MR184|100388-300402|Write only
1647 +|0280-0282(HEX)|MR280|100640-300642|Read only
1648 +|0300-030B(HEX)|MR300|100768-300779|Read/write
1649 +|0314-0317(HEX)|MR314|100788-300791|Read/write
1650 +|031A(HEX)|MR31A|100794-300794|Read/write
1651 +|0320-0321(HEX)|MR320|100800-300801|Read/write
1652 +|0400-0504(HEX)|MR400|101024-301284|Read/write
1653 +|0506(HEX)|MR506|101286-301286|Read/write
1654 +|0510-0514(HEX)|MR510|101296-301300|Read/write
1655 +|0516-0524(HEX)|MR516|101302-301316|Read/write
1656 +|0526(HEX)|MR526|101318-301318|Read/write
1657 +|0580-08C3(HEX)|MR580|101408-302243|Read/write
1658 +|~-~-|Ctrl|0-2|~-~-
1659 +
1660 +**✎Note:**
1661 +
1662 +* The upper 2 bits of the address of the HMI register are taken as the sub address, and the real address is the last four bits (for example, if the address is 100256, then 10 is the sub address as 1, and 0256 is the real address);
1663 +* The address range in the table is only divided by the start and end addresses, and some of the addresses in the range have no corresponding address in MR13;
1664 +* The Ctrl register is used to store the control group number and BCC check mode.
1665 +
1666 +**Ctrl Register Description**
1667 +
1668 +* The Ctrl register is a special register that does not communicate with the temperature controller. User needs to assign value in the screen according to the settings as in the temperature controller.
1669 +* Ctrl0 indicates the setting of the control character, the valid values are 1, 2, 3 respectively, and the corresponding control group is: STX_ETX_CR, STX_ETX_CR LF and @_:_CR .
1670 +* Ctrl1 indicates the BCC block check mode. The valid value range is 1-4. The corresponding check mode is: 1.ADD, 2.ADD_two's cmp, 3.XOR, 4.None;
1671 +* Ctrl3 reserved
1672 +
1673 +**✎Note:**
1674 +
1675 +After reloading project or restarting the HMI, HMI will reset the value of ctrl0 and ctrl1 as 1, so user need to set these two values to make it the same as it in the temperature controller, then communication will be normal.
1676 +
1677 +**Cable Wiring**
1678 +
1679 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5e9a81a14106da9e.png?width=392&height=223&rev=1.1||alt="12.PLC Protocol_html_5e9a81a14106da9e.png" height="223" width="392"]]
1680 +
1681 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_1897d92be6948d58.png?width=393&height=223&rev=1.1||alt="12.PLC Protocol_html_1897d92be6948d58.png" height="223" width="393"]]
1682 +
1683 +**✎Note:** COM3 only available in PI8000/PI9000 series.
1684 +
1197 1197  = Create communication with **Modbus RTU** =
1198 1198  
1199 1199  == **V-BOX as Slave** ==
image-20220831161356-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +27.0 KB
Content