Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
From version 144.1
edited by Ben
on 2022/08/31 16:14
on 2022/08/31 16:14
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 24 added, 0 removed)
- image-20220831163041-1.png
- image-20220831163406-2.png
- image-20220831163422-3.png
- image-20220831163441-4.png
- image-20220831163548-5.png
- image-20220831163553-6.png
- image-20220831163923-7.png
- image-20220831164626-1.png
- image-20220831164646-2.png
- image-20220831164700-3.png
- image-20220831164731-4.png
- image-20220831165008-1.png
- image-20220831165017-2.png
- image-20220831165031-3.png
- image-20220831165238-4.png
- image-20220831170147-1.png
- image-20220831170215-2.png
- image-20220831170254-3.png
- image-20220831170306-4.png
- image-20220831171127-1.png
- image-20220902104329-1.png
- image-20220902111121-1.png
- image-20220902111754-2.png
- image-20220902111833-3.png
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki.B en1 +XWiki.Bob - Content
-
... ... @@ -182,7 +182,7 @@ 182 182 183 183 MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 184 184 185 -**1) PLCSettings**185 +**1)V-BOX setting** 186 186 187 187 |**Item**|**Settings**|**Note** 188 188 |Protocol|Allen-Bradlley DF1 Advanced| ... ... @@ -436,7 +436,7 @@ 436 436 437 437 Supported Series: Siemens S7-300 series PLC 438 438 439 -**1) PLCSetting**439 +**1)V-BOX setting** 440 440 441 441 |**Items**|**Settings**|**Note** 442 442 |Protocol|Simens S7-300 Ethernet| ... ... @@ -498,7 +498,7 @@ 498 498 499 499 Supported Series: Siemens S7-400, S7-1200 and S7-1500 500 500 501 -**1) PLCSetting**501 +**1)V-BOX setting** 502 502 503 503 |=**Items**|=**Settings**|=**Note** 504 504 |Protocol|Siemens S7-XXX| ... ... @@ -704,6 +704,112 @@ 704 704 [[image:image-20220825100845-4.png]] 705 705 706 706 707 +== **FX3U Ethernet Protocol** == 708 + 709 + Mitsubishi FX3U series PLC 710 + 711 +**HMI Settings** 712 + 713 +|Items|Settings|Note 714 +|Protocol|Mitsubishi FX3U| 715 +|Connection|Ethernet| 716 +|Port No.|5009|Must be the same as the PLC setting 717 +|PLC station No.|0| 718 + 719 +**Address List** 720 + 721 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 722 +|(% colspan="1" rowspan="7" %)Bit|X|X|X OOO|0~~377| 723 +|Y|Y|Y OOO|0~~377| 724 +|M|M|M DDDD|0~~7679| 725 +|SM|SM|SM DDDD|8000~~8511| 726 +|S|S|S DDDD|0~~4095| 727 +|TS|TS|TS DDD|0~~511| 728 +|CS|CS|CS DDD|0~~255| 729 +|(% colspan="1" rowspan="9" %)Word|CN|CN|CN DDD|0~~199| 730 +|TN|TN|TN DDD|0~~511| 731 +|D|D|D DDDD|0~~7999| 732 +|SD|SD|SD DDDD|8000~~8511| 733 +|R|R|R DDDDD|0~~32767| 734 + 735 +**Ethernet Module Settings** 736 + 737 +FX3U-ENET-L module configuration 738 +Set up the FX3U-ENET-L Ethernet module settings as follows. 739 +Select the module location, which in this document is Module 0. 740 + 741 +[[image:image-20221116094003-1.png]] 742 + 743 + 744 +Select "Operational setting" to enter the following screen. 745 + 746 +The Ethernet module IP is set to 192.168.39.254 in this document, and other options are default. 747 + 748 +[[image:image-20221116094019-2.png]] 749 + 750 + 751 +Select "Open setting" to enter the setting interface, the settings are as follows. 752 + 753 +The third item "Protocol" selects TCP, and "Open system" selects MELSOFT connection, which allows the 754 + 755 +Mitsubishi programming software GX works2 to communicate with the FX3U via the Ethernet module. 756 + 757 +[[image:image-20221116094038-3.png]] 758 + 759 + 760 +Click on "transter setup" - "PC side I/F setting", see the following figure. 761 + 762 +After setting, the first download must use the programming cable, as shown in the figure; after that, can 763 + 764 +use the IP set in the "Ethernet board" to communicate directly with the network cable. 765 + 766 +[[image:image-20221116094122-4.png||height="422" width="707"]] 767 + 768 + 769 +Read and write data from the Ethernet module 770 + 771 +[[image:image-20221116094131-5.png||height="551" width="708"]] 772 + 773 + 774 +Set "Transter setup" to COM communication, and read or write operation as shown below 775 + 776 +[[image:image-20221116094150-6.png]] 777 + 778 + 779 +**PLC Settings (GX Works 2)** 780 + 781 +Create a blank FX5U project 782 + 783 +Find Current Connection in the navigation 784 + 785 +[[image:image-20221116094206-7.png||height="425" width="711"]] 786 + 787 + 788 +Select Connection Channel List 789 + 790 +Select Ethernet board communication 791 + 792 +[[image:image-20221116094709-9.png||height="427" width="715"]] 793 + 794 + 795 +Select Ethernet Module 796 +Set the IP address of the PLC 797 + 798 +[[image:image-20221116094736-11.png||height="682" width="716"]] 799 + 800 + 801 +Read or write PLC data, in this document is read 802 + 803 +[[image:image-20221116094755-12.png||height="426" width="715"]] 804 + 805 +[[image:image-20221116094803-13.png||height="427" width="715"]] 806 + 807 +**V-BOX Communication Setting** 808 + 809 + 810 + 811 + 812 + 707 707 == **FX5U Serial Protocol** == 708 708 709 709 Mitsubishi FX5U series PLC ... ... @@ -858,11 +858,10 @@ 858 858 859 859 [[image:image-20220825112403-1.png||alt="图片-20220825112403-1.png"]] 860 860 861 -**5) 电缆布线**967 +**5)Cable Wiring** 862 862 863 863 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 864 864 865 - 866 866 == **L02 Serial Protocol** == 867 867 868 868 Mitsubishi L02 series CPU built-in serial port. ... ... @@ -1194,10 +1194,362 @@ 1194 1194 * Please set the communication delay time of 10ms in setting, to avoid that the instrument may not be able to communicate in a short time due to too fast data access and too much connection requests. 1195 1195 * [[image:image-20220831161356-1.png]]Because of the particularity of the instrument, it is necessary to write the value of the address in the menu interface corresponding to the address, and to enter the menu where the address locates, so that the value could be written. 1196 1196 1197 -= Create communication with ** Modbus RTU** =1302 += Create communication with Xinje** PLC** = 1198 1198 1199 -== ** V-BOXasSlave** ==1304 +== **XC serial protocol** == 1200 1200 1306 +**1)V-BOX Settings** 1307 + 1308 +|**Item**|**Settings**|**Note** 1309 +|Protocol|XINJE XC MODBUS| 1310 +|Connection|RS232| 1311 +|Baud rate|19200| 1312 +|Data bit|8| 1313 +|Parity|EVEN| 1314 +|Stop bit|1| 1315 +|PLC station No.|1| 1316 + 1317 +**2)Address List** 1318 + 1319 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 1320 +|Bit|M|M|M d|0~~8511| 1321 +|Bit|X|X|X o|0~~1747| 1322 +|Bit|Y|Y|Y o|0~~1747| 1323 +|Bit|S|S|S d|0~~1023| 1324 +|Bit|T|T|T d|0~~4095| 1325 +|Bit|C|C|C d|0~~634| 1326 +|Word|D|D|D d|0~~8511| 1327 +|Word|TD|TD|TD d|0~~618| 1328 +|Word|CD|CD|CD d|0~~634| 1329 +|Word|FD|FD|FD d|0~~8511| 1330 + 1331 +**3)Configure the communication protocol** 1332 + 1333 + 1334 +[[image:image-20220831163041-1.png]] 1335 + 1336 +**4)Cable Wiring** 1337 + 1338 +Figure 1339 + 1340 +[[image:image-20220831163406-2.png]][[image:image-20220831163422-3.png]] 1341 + 1342 +Pin Definition Diagram 1343 + 1344 +[[image:image-20220831163441-4.png]] 1345 + 1346 +== **XD serial protocol** == 1347 + 1348 +**1)V-BOX Settings** 1349 + 1350 +Supported Series: Delta Xinjie XD/XE Series PLC 1351 + 1352 +|**Item**|**Settings**|**Note** 1353 +|Protocol|XINJE XD/XC MODBUS| 1354 +|Connection|RS232| 1355 +|Baud rate|19200| 1356 +|Data bit|8| 1357 +|Parity|EVEN| 1358 +|Stop bit|1| 1359 +|PLC station No.|1| 1360 + 1361 +**2)Address List** 1362 + 1363 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 1364 +|Bit|M|M|M d|0~~74999| 1365 +|Bit|X1xx|X1xx|X1xx o|0~~1177| 1366 +|Bit|X2xx|X2xx|X2xx o|0~~277| 1367 +|Bit|X|X|X o|0~~77| 1368 +|Bit|Y1xx|Y1xx|Y1xx o|0~~1177| 1369 +|Bit|Y2xx|Y2xx|Y2xx o|0~~277| 1370 +|Bit|Y|Y|Y o|0~~4095| 1371 +|Bit|SM|SM|SM d|0~~4999|((( 1372 + 1373 +))) 1374 +|Bit|T|T|T d|0~~4999| 1375 +|Bit|C|C|C d|0~~4999| 1376 +|Bit|ET|ET|ET d|0~~31| 1377 +|Bit|SE|SE|SE d|0~~31| 1378 +|Bit|HM|HM|HM d|0~~11999| 1379 +|Bit|HSC|HSC|HSC d|0~~39| 1380 +|Bit|HS|HS|HS d|0~~999| 1381 +|Bit|HT|HT|HT d|0~~1999| 1382 +|Bit|HC|HC|HC d|0~~1999| 1383 +|Bit|S|S|S d|0~~7999| 1384 +|Word|D|D|D d|0~~69999| 1385 +|Word|ID|ID|ID d|0~~99| 1386 +|Word|ID1xx|ID1xx|ID1xx d|0~~999| 1387 +|Word|ID2xx|ID2xx|ID2xx d|0~~299| 1388 +|Word|QD|QD|QD d|0~~99| 1389 +|Word|QD1xx|QD1xx|QD1xx d|0~~999| 1390 +|Word|QD2xx|QD2xx|QD2xx d|0~~299| 1391 +|Word|SD|SD|SD d|0~~4999| 1392 +|Word|TD|TD|TD d|0~~575| 1393 +|Word|CD|CD|CD d|0~~575| 1394 +|Word|ETD|ETD|ETD d|0~~31| 1395 +|Word|HD|HD|HD d|0~~24999| 1396 +|Word|HSD|HSD|HSD d|0~~1023| 1397 +|Word|HTD|HTD|HTD d|0~~95| 1398 +|Word|HCD|HCD|HCD d|0~~95| 1399 +|Word|HSCD|HSCD|HSCD d|0~~31| 1400 +|Word|FD|FD|FD d|0~~8191| 1401 +|Word|SFD|SFD|SFD d|0~~5999| 1402 +|Word|FS|FS|FS d|0~~47| 1403 + 1404 +**3)Configure the communication protocol** 1405 + 1406 +[[image:image-20220831163923-7.png]] 1407 + 1408 + 1409 + 1410 +**4)Cable Wiring** 1411 + 1412 +Figure 1413 + 1414 +[[image:image-20220831163406-2.png]][[image:image-20220831163553-6.png]] 1415 + 1416 +Pin Definition Diagram 1417 + 1418 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830160232-3.png?rev=1.1||alt="image-20220830160232-3.png"]] 1419 + 1420 + 1421 += Create communication with **Schneider PLC** = 1422 + 1423 +== **Schneider MODBUS RTU** == 1424 + 1425 +**1)V-BOX Setting** 1426 + 1427 +|=**Parameters**|=**Recommended**|=**Notes** 1428 +|**Protocol**|(% colspan="1" %)Schneider MODBUS RTU| 1429 +|**Connection**|RS485| 1430 +|**Baud rate**|19200| 1431 +|**Data bit**|8| 1432 +|**Parity**|Even| 1433 +|**Stop bit**|1| 1434 +|**PLC station No.**|1| 1435 + 1436 +**2)Address List** 1437 + 1438 +|=**Bit/Word**|=**Device type**|=**Format**|=**Range**|=**Memo** 1439 +|B|IX|DDDDDo|0 ~~ 655357|Input bit (read only) 1440 +|B|QX|DDDDDo|0 ~~ 655357|Write multiple coils 1441 +|B|MX|DDDDDDo|0 ~~ 9999997|Output register bit (octal) 1442 +|W|MW|DDDDDD|0 ~~ 999999|Output register 1443 +|DW|MD|DDDDDD|0 ~~ 999999|Output register 1444 + 1445 +**3)Configure the communication protocol** 1446 + 1447 +[[image:image-20220902104329-1.png]] 1448 + 1449 +**4)Cable Wiring** 1450 + 1451 +**RS-485 2W **(RJ45 Connector): The following is the view from the soldering point of a connector. 1452 + 1453 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220817154212-1.jpeg?width=554&height=315&rev=1.1||alt="image-20220817154212-1.jpeg" height="315" width="554"]] 1454 + 1455 += Create communication with Inovance** PLC** = 1456 + 1457 +== **H3U serial protocol** == 1458 + 1459 +**1)V-BOX Settings** 1460 + 1461 +|**Item**|**Settings**|**Note** 1462 +|Protocol|INOVANCE H3U PLC| 1463 +|Connection|RS422| 1464 +|Baud rate|9600| 1465 +|Data bit|7| 1466 +|Parity|EVEN| 1467 +|Stop bit|1| 1468 +|PLC station No.|0| 1469 + 1470 +**2)Address List** 1471 + 1472 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 1473 +|Bit|X|X|X o|0~~303237| 1474 +|Bit|Y|Y|Y o|0~~303237| 1475 +|Bit|M|M|M d|0~~99999| 1476 +|Bit|T|T|T d|0~~99999| 1477 +|Bit|C|C|C d|0~~99999| 1478 +|Bit|SM|SM|SM d|8000~~999| 1479 +|Bit|S|T|S d|0~~99999| 1480 +|Bit|Lamp|Lamp|Lamp d|0~~0| 1481 +|Word|X|X|X o|0~~303237| 1482 +|Word|Y|Y|Y o|0~~303237| 1483 +|Word|M|M|M d|0~~99999| 1484 +|Word|T|T|T d|0~~99999| 1485 +|Word|C|C|C d|0~~199| 1486 +|Word|D|D|D d|0~~7999| 1487 +|Word|S|S|S d|0~~99999| 1488 +|Word|SD|SD|SD d|8000~~9999| 1489 +|Word|R|R|R d|0~~32767| 1490 + 1491 +**3)Configure the communication protocol** 1492 + 1493 +[[image:image-20220831164626-1.png]] 1494 + 1495 + 1496 + 1497 +**4)Cable Wiring** 1498 + 1499 +Figure 1500 + 1501 +[[image:image-20220831164646-2.png]][[image:image-20220831164700-3.png]] 1502 + 1503 +Pin Definition Diagram 1504 + 1505 +[[image:image-20220831164731-4.png]] 1506 + 1507 += Create communication with Panasonic** PLC** = 1508 + 1509 +== **FP serial protocol** == 1510 + 1511 +**1)V-BOX Settings** 1512 + 1513 +|**Item**|**Settings**|**Note** 1514 +|Protocol|Panasonic FP MFWTOCOL| 1515 +|Connection|RS232| 1516 +|Baud rate|9600| 1517 +|Data bit|8| 1518 +|Parity|ODD| 1519 +|Stop bit|1| 1520 +|PLC station No.|1| 1521 + 1522 +**2)Address List** 1523 + 1524 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 1525 +|Bit|X|X|X d|0~~9999| 1526 +|Bit|Y|Y|Y d|0~~9999| 1527 +|Bit|R|R|R d|0~~9999| 1528 +|Bit|T|T|T d|0~~9999| 1529 +|Bit|C|C|C d|0~~9999| 1530 +|Bit|L|L|L d|0~~9999| 1531 +|Word|WX|WX|WX d|0~~9999| 1532 +|Word|WY|WY|WY d|0~~9999| 1533 +|Word|WR|WR|WR d|0~~9999| 1534 +|Word|WL|WL|WL d|0~~9999| 1535 +|Word|LD|LD|LD d|0~~9999| 1536 +|Word|DT|DT|DT d|0~~65535| 1537 +|Word|FL|FL|FL d|0~~9999| 1538 +|Word|EV|EV|EV d|0~~9999| 1539 +|Word|SV|SV|SV d|0~~9999| 1540 + 1541 +**3)Configure the communication protocol** 1542 + 1543 +[[image:image-20220831165238-4.png]] 1544 + 1545 + 1546 + 1547 +**4)Cable Wiring** 1548 + 1549 +Figure 1550 + 1551 +[[image:image-20220831165031-3.png]][[image:image-20220831165017-2.png]] 1552 + 1553 +Pin Definition Diagram 1554 + 1555 +[[image:image-20220831165008-1.png]] 1556 + 1557 += Create communication with LS** PLC** = 1558 + 1559 +== **XBC serial protocol** == 1560 + 1561 +**1)V-BOX Settings** 1562 + 1563 +|**Item**|**Settings**|**Note** 1564 +|Protocol|LS XBC CNet| 1565 +|Connection|RS232| 1566 +|Baud rate|115200| 1567 +|Data bit|8| 1568 +|Parity|NONE| 1569 +|Stop bit|1| 1570 +|PLC station No.|1| 1571 + 1572 +**2)Address List** 1573 + 1574 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 1575 +|Bit|P|P|P d|0~~2047| 1576 +|Bit|M|M|M d|0~~2047| 1577 +|Bit|L|L|L d|0~~11263| 1578 +|Bit|K|K|K d|0~~16183| 1579 +|Bit|F|F|F d|0~~2047| 1580 +|Bit|D|D|D d|0~~32767| 1581 +|Bit|R|R|R d|0~~32767| 1582 +|Bit|U|U|U d|0~~4095| 1583 +|Word|P|P|P d|0~~2047| 1584 +|Word|M|M|M d|0~~2047| 1585 +|Word|L|L|L d|0~~11263| 1586 +|Word|K|K|K d|0~~16183| 1587 +|Word|F|F|F d|0~~2047| 1588 +|Word|C|C|C d|0~~2047| 1589 +|Word|T|T|T d|0~~2047| 1590 +|Word|D|D|D d|0~~32767| 1591 +|Word|N|N|N d|0~~21503| 1592 +|Word|R|R|R d|0~~32767| 1593 +|Word|U|U|U d|0~~4095| 1594 +|Word|Z|Z|Z d|0~~127| 1595 +|Word|S|S|S d|0~~127| 1596 + 1597 +**3)Configure the communication protocol** 1598 + 1599 +[[image:image-20220831170147-1.png]] 1600 + 1601 +**4)Cable Wiring** 1602 + 1603 +Figure 1604 + 1605 +[[image:image-20220831170306-4.png]][[image:image-20220831170254-3.png]] 1606 + 1607 +Pin Definition Diagram 1608 + 1609 +[[image:image-20220831170215-2.png]] 1610 + 1611 +== **XGK FEnet Ethernet protocol** == 1612 + 1613 +Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module 1614 + 1615 +**1)V-BOX Settings** 1616 + 1617 +|**Items**|**Settings**|**Note** 1618 +|Protocol|LG XGK FEnet(Ethernet)| 1619 +|Connection|Ethernet| 1620 +|Port No.|2004| 1621 + 1622 +**2)Address List** 1623 + 1624 +|**Type**|**Register**|**Range**|**Format**|**Note** 1625 +|(% rowspan="14" %)Word|P|0~~2047|P d| 1626 +|M|0~~2047|M d| 1627 +|K|0~~2047|K d| 1628 +|F|0~~2047|F d| 1629 +|T|0~~2047|T d| 1630 +|C|0~~2047|C d| 1631 +|Z|0~~127|Z d| 1632 +|S|0~~127|S d| 1633 +|L|0~~11263|L d| 1634 +|N|0~~21503|N d| 1635 +|D|0~~32767|D d| 1636 +|R|0~~32767|R d| 1637 +|ZR|0~~65535|ZR d| 1638 +|UxDD|0~~6331|UxDD nndd|nn: 0~~63, dd: 0~~31 1639 + 1640 +**✎Note:** 1641 + 1642 +* In addition to the "UxDD" register, the others correspond to the PLC register one by one. UxDD corresponds to U in the PLC; 1643 +* The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC; 1644 +* All bit registers are in the form of bits in word, and the range is the same as the word register; 1645 + 1646 +**3)Communication Settings** 1647 + 1648 +[[image:image-20220831171127-1.png]] 1649 + 1650 +**4)Cable Wiring** 1651 + 1652 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 1653 + 1654 += Create communication with **Modbus ** = 1655 + 1656 +== **MODBUS RTU Slave (All function)** == 1657 + 1201 1201 Select the protocol "Modbus RTU Slave (All Fuction)", 1202 1202 1203 1203 Then set baud rate, port, stop bits, data bits, parity. ... ... @@ -1205,7 +1205,7 @@ 1205 1205 (% style="text-align:center" %) 1206 1206 [[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]] 1207 1207 1208 -== ** V-BOXasMaster** ==1665 +== **MODBUS RTU Master** == 1209 1209 1210 1210 Select the protocol "Modbus RTU Master", 1211 1211 ... ... @@ -1241,6 +1241,61 @@ 1241 1241 |(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils) 1242 1242 |0F (Write multiple bits) 1243 1243 1701 +== **MODBUS TCP Slave (All function)** == 1702 + 1703 +Supported series: MODBUS TCP controller 1704 + 1705 +V-B0X works as MODBUS TCP MASTER connecting with TCP SLAVE 1706 + 1707 +**1)V-BOX Setting** 1708 + 1709 +|**Items**|**Settings**|**Note** 1710 +|Protocol|MODBUS TCP Slave (All function)| 1711 +|Connection|Ethernet| 1712 +|Port No.|502| 1713 +|PLC station No.|1 1714 + 1715 +**2)Address List** 1716 + 1717 +|**Type**|**Register**|**Function code & Description** 1718 +|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers) 1719 +|06 (write single register: write a binary value to a holding register) 1720 +|10 (write values to multiple addresses ) 1721 +|(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers) 1722 +|06 (write single register: write a binary value to a holding register) 1723 +|10 (write values to multiple addresses ) 1724 +|(% rowspan="3" %)W6|03 (read holding register: read current binary value in one or more holding registers) 1725 +|06 (write single register: write a binary value to a holding register) 1726 +|10 (write values to multiple addresses ) 1727 +|(% rowspan="2" %)W16|03 (read holding register: read current binary value in one or more holding registers) 1728 +|10 (write values to multiple addresses ) 1729 +|(% rowspan="11" %)Bit|(% rowspan="3" %)0|01 (Read coil state) 1730 +|05 (Force a single coil to force the on/off state of a logic coil) 1731 +|0F (Write multiple bits, ie write continuously) 1732 +|(% rowspan="3" %)1|02 (Read the input state) 1733 +|05 (Force a single coil to force the on/off state of a logic coil) 1734 +|0F (Write multiple bits) 1735 +|(% rowspan="3" %)W5|01 (Read coil state to obtain the current state of a set of logic coils) 1736 +|05 (Force a single coil to force the on/off state of a logic coil) 1737 +|0F (Write multiple bits) 1738 +|(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils) 1739 +|0F (Write multiple bits) 1740 + 1741 +**3)Communication Settings** 1742 + 1743 +Configure V-BOX Ethernet IP in Networking Settings 1744 + 1745 +[[image:image-20220902111833-3.png]] 1746 + 1747 + 1748 +Configure PLC Ethernet IP in Communication; 1749 + 1750 +[[image:image-20220902111121-1.png]] 1751 + 1752 +**4)Cable Wiring** 1753 + 1754 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 1755 + 1244 1244 == **communicate with VB inverter** == 1245 1245 1246 1246 [[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20VB%20inverter.zip]]
- image-20220831163041-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +58.6 KB - Content
- image-20220831163406-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +28.4 KB - Content
- image-20220831163422-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +53.9 KB - Content
- image-20220831163441-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.7 KB - Content
- image-20220831163548-5.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +37.1 KB - Content
- image-20220831163553-6.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +37.1 KB - Content
- image-20220831163923-7.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +57.3 KB - Content
- image-20220831164626-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +56.1 KB - Content
- image-20220831164646-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +28.4 KB - Content
- image-20220831164700-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +66.6 KB - Content
- image-20220831164731-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +12.3 KB - Content
- image-20220831165008-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.3 KB - Content
- image-20220831165017-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +36.2 KB - Content
- image-20220831165031-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +28.3 KB - Content
- image-20220831165238-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +57.4 KB - Content
- image-20220831170147-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +57.1 KB - Content
- image-20220831170215-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +14.3 KB - Content
- image-20220831170254-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +43.5 KB - Content
- image-20220831170306-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +28.5 KB - Content
- image-20220831171127-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +60.1 KB - Content
- image-20220902104329-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +58.7 KB - Content
- image-20220902111121-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +60.9 KB - Content
- image-20220902111754-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +57.6 KB - Content
- image-20220902111833-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +56.1 KB - Content