Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 16 removed)
- image-20220825143728-1.png
- image-20220825160227-1.png
- image-20220825160341-2.png
- image-20220825160648-3.png
- image-20220825160820-4.png
- image-20220825160925-5.png
- image-20220825160929-6.png
- image-20220825161440-7.png
- image-20220825161612-8.png
- image-20220831155101-1.png
- image-20220831155129-2.png
- image-20220831155157-3.png
- image-20220831160010-4.png
- image-20220831160055-5.png
- image-20220831161041-1.png
- image-20220831161356-1.png
Details
- Page properties
-
- Content
-
... ... @@ -1,44 +1,43 @@ 1 -= CreatemmunicationwithWECONPLC=1 += (% style="color:inherit; font-family:inherit" %)**维控公司**(%%) = 2 2 3 -== **LX3V Serial Protocol** ==3 +== **LX3V 串行协议** == 4 4 5 - Supportedseries: WeconLX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM5 +支持系列:维控 LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM 6 6 7 -**1) V-BOX setting**7 +**1)可编程逻辑控制器设置** 8 8 9 -|** Item**|**Settings**|**Note**10 -| Protocol|WECONLX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM|11 -| Connection|RS422/RS485|12 -| Baud rate|9600|13 -| Data bit|7|14 -| Parity|EVEN|15 -| Stop bit|1|16 -|PLC station No.|1|9 +|**项目**|**设置**|**注意** 10 +|协议|维控 LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM| 11 +|连接|RS422/RS485| 12 +|波特率|9600| 13 +|数据位|7| 14 +|平价|甚至| 15 +|停止位|1| 16 +|PLC站号|1| 17 17 18 -**2) Address List**18 +**2)可编程逻辑控制器地址列表** 19 19 20 - 21 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 22 -|(% rowspan="6" %)Bit|X|X|Xo|0~~303237| 20 +|**类型**|**设备寄存器**|**人机界面寄存器**|**格式**|**范围**|**注意** 21 +|(% rowspan="6" %)位|X|X|断续器|0~~303237| 23 23 |Y|Y|Y o|0~~303237| 24 24 |M|M|M d|0~~99999| 25 -|T|T| Td|0~~99999|26 -|C|C| C d|0~~99999|27 -|S|S| S d|0~~99999|28 -|(% rowspan="8" %) Word|X|X|Xo|0~~303237|24 +|T|T|S C|0~~99999| 25 +|C|C|断续器|0~~99999| 26 +|S|S|断续器|0~~99999| 27 +|(% rowspan="8" %)词|X|X|断续器|0~~303237| 29 29 |Y|Y|Y o|0~~303237| 30 30 |M|M|M d|0~~99999| 31 -|T|T| Td|0~~99999|32 -|C|C| C d|0~~199|33 -|D|D| Dd|0~~7999|34 -|S|S| S d|0~~99999|35 -| SD|SD|SDd|8000~~9999|30 +|T|T|S C|0~~99999| 31 +|C|C|断续器|0~~199| 32 +|D|D|C C|0~~7999| 33 +|S|S|断续器|0~~99999| 34 +|标清|标清|标清 d|8000~~9999| 36 36 37 -**3) Configure the communication protocol**36 +**3)配置通信协议** 38 38 39 39 [[image:image-20220824152217-1.png||alt="图片-20220824152217-1.png"]] 40 40 41 -**4) Cable Wiring**40 +**4)硬件连接** 42 42 43 43 * **RS422** 44 44 ... ... @@ -176,7 +176,7 @@ 176 176 177 177 The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC. 178 178 179 -= Create communication with**Rockwell PLC** =178 += **Rockwell PLC** = 180 180 181 181 == (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** == 182 182 ... ... @@ -217,7 +217,7 @@ 217 217 218 218 [[image:image-20220824110724-1.png]] 219 219 220 -== **Micro850_FreeTag Protocol** ==219 +== **Micro850_FreeTag** == 221 221 222 222 ((( 223 223 ((( ... ... @@ -425,7 +425,7 @@ 425 425 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]] 426 426 427 427 428 -= Create communication with**Siemens PLC** =427 += **Siemens PLC** = 429 429 430 430 == **S7-200 Smart Ethernet Protocol** == 431 431 ... ... @@ -608,8 +608,9 @@ 608 608 609 609 [[image:image-20220824162342-2.png]] 610 610 611 -= Create communication with **Mitsubishi PLC** = 612 612 611 += **Mitsubishi PLC** = 612 + 613 613 == **FX1S,1N,2N Serial Protocol** == 614 614 615 615 Supported Series: Mitsubishi FX1S, FX1N, FX2N series ... ... @@ -862,67 +862,6 @@ 862 862 863 863 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 864 864 865 - 866 -== **L02 Serial Protocol** == 867 - 868 -Mitsubishi L02 series CPU built-in serial port. 869 - 870 -**1)V-BOX Settings** 871 - 872 -|**Item**|**Settings**|**Note** 873 -|Protocol|Mitsubishi L02| 874 -|Connection|RS422| 875 -|Baud rate|115200| 876 -|Data bit|8| 877 -|Parity|Odd| 878 -|Stop bit|1| 879 -|PLC station No.|1~~255|Need to be the same as PLC settings 880 - 881 -**2)Address List** 882 - 883 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 884 -|Bit|X|X|X h|0~~FFFF| 885 -|Bit|Y|Y|Y h|0~~FFFF| 886 -|Bit|M|M|M d|0~~9999| 887 -|Bit|L|L|L d|0~~9999| 888 -|Bit|F|F|F d|0~~9999| 889 -|Bit|B|B|B h|0~~FFFF| 890 -|Bit|V|V|V d|0~~2047| 891 -|Bit|TC|TC|TC d|0~~9999| 892 -|Bit|SS|SS|SS d|0~~9999| 893 -|Bit|SC|SC|SC d|0~~9999| 894 -|Bit|CS|CS|CS d|0~~9999| 895 -|Bit|CC|CC|CC d|0~~9999| 896 -|Bit|SB|SB|SB h|0~~FFFF| 897 -|Bit|SM|SM|SM d|0~~2047| 898 -|Bit|STS|STS|STS d|0~~1023| 899 -|Bit|S|S|S d|0~~9999| 900 -|Bit|DX|DX|DX h|0~~FFFF| 901 -|Bit|DY|DY|DY h|0~~FFFF| 902 -|Bit|TS|TS|TS d|0~~9999| 903 -|Bit|Dbit|Dbit|Dbit d.d|0~~99999.0~~15| 904 -|Word|W|W|W h|0~~FFFF| 905 -|Word|TN|TN|TN d|0~~99999| 906 -|Word|SN|SN|SN d|0~~99999| 907 -|Word|CN|CN|CN d|0~~99999| 908 -|Word|R|R|R d|0~~99999| 909 -|Word|SW|SW|SW h|0~~FFFF| 910 -|Word|Z|Z|Z d|0~~99999| 911 -|Word|ZR|ZR|ZR h|0~~FFFF| 912 -|Word|D|D|D d|0~~99999| 913 - 914 -**3)Communication Settings** 915 - 916 -[[image:image-20220825160648-3.png]] 917 - 918 -**4)Cable Wiring** 919 - 920 -* **RS422** 921 - 922 -[[image:image-20220825161612-8.png]] 923 - 924 -[[image:image-20220825160820-4.png]] 925 - 926 926 == **L02 Ethernet Protocol** == 927 927 928 928 Mitsubishi L series CPU built-in Ethernet port. ... ... @@ -968,8 +968,12 @@ 968 968 |Word|ZR|ZR|ZR h|0~~FFFF| 969 969 |Word|D|D|D d|0~~99999| 970 970 971 -**3) PLCSettings(GX Works2 )**910 +**3)Configure the communication protocol** 972 972 912 +[[image:image-20220825142659-1.png]] 913 + 914 +**4)PLC Settings (GX Works2 )** 915 + 973 973 Create a project 974 974 975 975 Set PLC IP, subnet mask and gateway; ... ... @@ -988,10 +988,6 @@ 988 988 989 989 Restart PLC device; 990 990 991 -**4)Configure the communication protocol** 992 - 993 -[[image:image-20220825142659-1.png]] 994 - 995 995 **5)Cable Wiring** 996 996 997 997 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]] ... ... @@ -1000,7 +1000,7 @@ 1000 1000 1001 1001 Mitsubishi QJ71E71 Ethernet communication module; 1002 1002 1003 -** 1)V-BOX Settings**942 +**V-BOX Settings** 1004 1004 1005 1005 |**Items**|**Settings**|**Note** 1006 1006 |Protocol|MIT QJ71E71 MELSEC| ... ... @@ -1008,7 +1008,7 @@ 1008 1008 |Port No.|1025|Must be the same as the PLC setting 1009 1009 |PLC station No.|0|Must be the same as the PLC setting 1010 1010 1011 -** 2)Address List**950 +**Address List** 1012 1012 1013 1013 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 1014 1014 |(% rowspan="18" %)Bit|X|X|X h|0~~1FFF| ... ... @@ -1040,8 +1040,17 @@ 1040 1040 |Z|Z|Z d|0~~15| 1041 1041 |ZR|ZR|ZR h|0~~FE7FF| 1042 1042 1043 -** 3)PLC Settings(GX Works2)**982 +**HMI Communication Settings** 1044 1044 984 +1) Enable HMI Ethernet in [Project Settings]; 985 + 986 + 987 +2) Set PLC IP in [Device IP] settings; 988 + 989 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2d566cb5ffb2618c.png?width=554&height=190&rev=1.1||alt="12.PLC Protocol_html_2d566cb5ffb2618c.png"]] 990 + 991 +**PLC Settings(GX Works2)** 992 + 1045 1045 * Click [Ethernet/CC IE/MELSECNET]; 1046 1046 * Please select [Ethernet] as network type; 1047 1047 * Set station I/O number according to situation (For example, 0000 means that the module is connected to PLC CPU in first order); ... ... @@ -1058,223 +1058,56 @@ 1058 1058 * Save settings; 1059 1059 * Download project into PLC and restart it 1060 1060 1061 -** 4)Configurethe communicationprotocol**1009 +**Cable Wiring** 1062 1062 1063 -[[image:image-20220825143728-1.png]] 1064 - 1065 -**5)Cable Wiring** 1066 - 1067 1067 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png"]] 1068 1068 1069 -= Create communication with **Delta PLC** = 1070 1070 1071 -= =**DVPEthernetProtocol** ==1014 += **台达 PLC** = 1072 1072 1016 +== **DVP 以太网协议** == 1017 + 1073 1073 [[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]] 1074 1074 1075 -== **DVP serial protocol** ==1020 +== **DVP 串行协议** == 1076 1076 1077 1077 [[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]] 1078 1078 1079 -= =**AS Ethernet Protocol** ==1024 += **欧姆龙可编程逻辑控制器** = 1080 1080 1081 -**1 )V-BOXSettings**1026 +== **CP1 系列协议** == 1082 1082 1083 -|=**Items**|=**Settings**|=**Note** 1084 -|Protocol|DELTA AS300 MODBUS TCP| 1085 -|Connection|Ethernet| 1086 -|Port No.|502| 1087 -|Device No.|1| 1088 -|HMI No.|0| 1089 - 1090 -**2)Address List** 1091 - 1092 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 1093 -|Bit|X|X|X d|0~~63| 1094 -|Bit|Y|Y|Y d|0~~63| 1095 -|Bit|D|D|D d|0~~29999| 1096 -|Bit|M|M|M d|0~~8191| 1097 -|Bit|SM|SM|SM d|0~~4095| 1098 -|Bit|S|S|S h|0~~2047| 1099 -|Bit|T|T|T d|0~~511| 1100 -|Bit|C|C|C d|0~~511| 1101 -|Bit|HC|HC|HC d|0~~255| 1102 -|Word|X|X|X h|0~~63| 1103 -|Word|Y|Y|Y d|0~~63| 1104 -|Word|SR|SR|SR d|0~~2047| 1105 -|Word|D|D|D d|0~~29999| 1106 -|Word|T|T|T d|0~~511| 1107 -|Word|C|C|C h|0~~511| 1108 -|Word|E|E|E d|0~~9| 1109 - 1110 -**3)Configure the communication protocol** 1111 - 1112 - 1113 -[[image:image-20220831160010-4.png]] 1114 - 1115 -**4)Cable Wiring** 1116 - 1117 -Figure 1118 - 1119 -[[image:image-20220831155101-1.png]][[image:image-20220831160055-5.png]] 1120 - 1121 -Pin Definition Diagram 1122 - 1123 -[[image:image-20220831155157-3.png]] 1124 - 1125 -= Create communication with **Omron PLC** = 1126 - 1127 -== **CP1 Series Protocol ** == 1128 - 1129 1129 [[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]] 1130 1130 1131 -== **C P2MSeries Protocol** ==1030 +== **CJ2M 系列协议** == 1132 1132 1133 1133 [[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]] 1134 1134 1034 += **Modbus RTU** = 1135 1135 1136 -== ** EC55Series Protocol** ==1036 +== **V-BOX 作为主** == 1137 1137 1138 - Supporteddevice: EC55temperatureinstrument1038 +选择协议“(% _istranslated="1" class="mark" %)Modbus RTU Slave(All Fuction)”, 1139 1139 1140 - **1)V-BOXSettings**1040 +(% class="mark" %)然后设置波特率,端口,停止位,数据位,奇偶校验 1141 1141 1142 -|**Items**|**Settings**|**Note** 1143 -|Protocol|Omron EC55| 1144 -|Connection|RS485 (9600, 2, 7, EVEN)| 1145 -|Port No.|None| 1146 -|PLC station No.|0| 1147 - 1148 -**2)Address List** 1149 - 1150 -|**Type**|**Register**|**Device range**|**HMI range**|**Function** 1151 -|(% rowspan="3" %)Double word|C0|0-13 (Hex)|0-19|Set read only parameter for area 0 1152 -|C1|0-4D(Hex)|0-77|Set Read/Write parameter for area 0 1153 -|C3|0-CD(Hex)|0-205|Set Read/Write parameter for area 1 1154 -|(% rowspan="6" %)Word|80|0-13(Hex)|0-19|Set read only parameter in area 0 1155 -|81|0-4D(Hex)|0-77|Set Read/Write parameter in area 0 1156 -|83|0-CD(Hex)|0-205|Set Read/Write parameter in area 1 1157 -|CP|-|0-6|Read controller intrinsic property 1158 -|CS|-|0-2|Read controller states 1159 -|CA|-|0-17|Action command 1160 - 1161 -**3)Device Settings** 1162 - 1163 -Omron E5CC PLC configuration 1164 - 1165 -After entering the Communication Settings menu, please set the parameters to the default values for the following table. Press the cycle key of the instrument to enter the next setting. 1166 - 1167 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_3d95e093792ba98a.png?width=550&height=229&rev=1.1||alt="12.PLC Protocol_html_3d95e093792ba98a.png" height="229" width="550"]] 1168 - 1169 -According to PLC configuration and communication port configuration information of the HMI, provide the corresponding steps and configuration screenshots. This configuration needs to communicate properly with the above PLC configuration. The project settings are as follows 1170 - 1171 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_be583aa69dd6cf4c.png?width=550&height=242&rev=1.1||alt="12.PLC Protocol_html_be583aa69dd6cf4c.png" height="242" width="550"]] 1172 - 1173 -**✎Note:** The communication settings for HMI should be consistent with this setting. 1174 - 1175 -**4)Configure the communication protocol** 1176 - 1177 -[[image:image-20220831161041-1.png]] 1178 - 1179 -**5)Cable Wiring** 1180 - 1181 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5e9a81a14106da9e.png?width=392&height=223&rev=1.1||alt="12.PLC Protocol_html_5e9a81a14106da9e.png" height="223" width="392"]] 1182 - 1183 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_1897d92be6948d58.png?width=393&height=223&rev=1.1||alt="12.PLC Protocol_html_1897d92be6948d58.png" height="223" width="393"]] 1184 - 1185 -**✎Note:** 1186 - 1187 -* COM3 only available in PI8000/PI9000 series. 1188 -* CA address could not support continuous writing function; 1189 -* Because of CP address intrinsic property: read control intrinsic property, so please place the character input part in use. Set address with CP0 and character length 10, used to display controller type. And place a number input part, set address with CP5 (cache size). Do not place other CP type address without CP0 in screen, otherwise CP type address is invalid 1190 -* When set value into read & write address, it is necessary to switch the temperature instrument meter to the corresponding interface according to the menu of the instrument where the address locates, so that the value could be written, otherwise, the value could not be written; When the communication write setting of the instrument is turned off, the writing function is invalid. Writing function could be opened by using the 00 address of the CA register, which write 01 value. 1191 -* When continuous writing of a value to a read-write address, please make sure all continuous writing address could be written. Otherwise, if one of these addresses could not be written, then all continuous writing commands will fail. 1192 -* Because of the mechanism problem, this protocol could not support CompoWay/F function that is read-write function of variables in protocol document. 1193 -* When using double-word address, set the data format to 32 bits, otherwise the read/write function is unable. 1194 -* Please set the communication delay time of 10ms in setting, to avoid that the instrument may not be able to communicate in a short time due to too fast data access and too much connection requests. 1195 -* [[image:image-20220831161356-1.png]]Because of the particularity of the instrument, it is necessary to write the value of the address in the menu interface corresponding to the address, and to enter the menu where the address locates, so that the value could be written. 1196 - 1197 -== **EtherNet/IP NX series Protocol** == 1198 - 1199 -Supported series: Omron NX/NJ series 1200 - 1201 -**HMI Setting** 1202 - 1203 -|**Items**|**Settings**|**Note** 1204 -|Protocol|Omron NX Ethernet/IP| 1205 -|Connection|Ethernet| 1206 -|Port No.|44818| 1207 -|PLC station No.|1| 1208 - 1209 -**Instruction** 1210 - 1211 -1) In Sysmac Studio, please select [Publish Only] for [Network Publish] when setting address tag. 1212 - 1213 -2) When [Do not publish] is selected for a tag, different import methods may lead to different results. When import tags by [Get Tags from Device], the tag will be eliminated. If [Import tags] is selected, the tags will be imported, but the communication will not succeed. 1214 - 1215 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_4156caf6f116c570.png?width=600&height=277&rev=1.1||alt="12.PLC Protocol_html_4156caf6f116c570.png" height="277" width="600"]] 1216 - 1217 -**Export labels from Sysmac Studio** 1218 - 1219 -Launch Sysmac Studio, under Global Variables create the address labels, and thenselect [Tools] -> [Export Global Variables]; 1220 - 1221 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_26f91dee66c723e9.png?width=600&height=276&rev=1.1||alt="12.PLC Protocol_html_26f91dee66c723e9.png" height="276" width="600"]] 1222 - 1223 -Launch PIStudio, in [Communication] Settings add Omron NX Ethernet/IP protocol; 1224 - 1225 -Click [Label manage]; 1226 - 1227 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_cd38d2d0c5187f6b.png?width=600&height=276&rev=1.1||alt="12.PLC Protocol_html_cd38d2d0c5187f6b.png" height="276" width="600"]] 1228 - 1229 -Click [Import labels] and then select the file exported in step 1; 1230 - 1231 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_52bd5da678bef9b4.png?width=600&height=403&rev=1.1||alt="12.PLC Protocol_html_52bd5da678bef9b4.png" height="403" width="600"]] 1232 - 1233 -The Import Status field shows the result, click [OK] to finish importing address labels; 1234 - 1235 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_7f0465a589b98912.png?width=600&height=291&rev=1.1||alt="12.PLC Protocol_html_7f0465a589b98912.png" height="291" width="600"]] 1236 - 1237 -**Communication Settings** 1238 - 1239 -Enable HMI Ethernet in [Project Settings]; 1240 - 1241 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_43b671f18153910d.png?width=405&height=107&rev=1.1||alt="12.PLC Protocol_html_43b671f18153910d.png" height="107" width="405"]] 1242 - 1243 -Set PLC IP in [Device IP] settings; 1244 - 1245 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_437cb087b36b5784.png?width=600&height=330&rev=1.1||alt="12.PLC Protocol_html_437cb087b36b5784.png" height="330" width="600"]] 1246 - 1247 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_60ef71528a99abf5.png?width=554&height=188&rev=1.1||alt="12.PLC Protocol_html_60ef71528a99abf5.png" height="188" width="554"]] 1248 - 1249 -**Cable Wiring** 1250 - 1251 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 1252 - 1253 -= Create communication with **Modbus RTU** = 1254 - 1255 -== **V-BOX as Slave** == 1256 - 1257 -Select the protocol "Modbus RTU Slave (All Fuction)", 1258 - 1259 -Then set baud rate, port, stop bits, data bits, parity. 1260 - 1261 1261 (% style="text-align:center" %) 1262 1262 [[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]] 1263 1263 1264 -== **V-BOX as Master** ==1045 +== **V-BOX 作为从站** == 1265 1265 1266 - Selectthe protocol",1047 +选择协议“(% _istranslated="1" class="mark" %)**Modbus RTU Master”**, 1267 1267 1268 - Thenset baud rate, port,stop bits, data bits, parity1049 +(% class="mark" %)然后设置波特率,端口,停止位,数据位,奇偶校验 1269 1269 1270 1270 (% style="text-align:center" %) 1271 1271 [[image:1624348709622-711.png||queryString="width=809&height=493" height="488" width="800" class="img-thumbnail"]] 1272 1272 1273 -** address list**1054 +**地址列表** 1274 1274 1275 1275 (% class="table-bordered" %) 1276 -|** type**|**register**|**Function code and description**1277 -|(% rowspan="11" %)词|(% rowspan="3" %)3|04 (Read Input Registers: Read the current binary value in one or more input registers)1057 +|**类型**|**注册**|**函数代码和描述** 1058 +|(% rowspan="11" %)词|(% rowspan="3" %)3|04(读取输入寄存器:读取一个或多个输入寄存器中的当前二进制值) 1278 1278 |06 (write single register: write a binary value to a holding register) 1279 1279 |10 (write values to multiple addresses ) 1280 1280 |(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers)
- image-20220825143728-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -124.7 KB - Content
- image-20220825160227-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -148.8 KB - Content
- image-20220825160341-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -121.7 KB - Content
- image-20220825160648-3.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -122.7 KB - Content
- image-20220825160820-4.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -24.9 KB - Content
- image-20220825160925-5.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -31.0 KB - Content
- image-20220825160929-6.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -31.0 KB - Content
- image-20220825161440-7.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -90.7 KB - Content
- image-20220825161612-8.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -86.3 KB - Content
- image-20220831155101-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -34.6 KB - Content
- image-20220831155129-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -44.9 KB - Content
- image-20220831155157-3.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -20.8 KB - Content
- image-20220831160010-4.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -59.6 KB - Content
- image-20220831160055-5.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -51.5 KB - Content
- image-20220831161041-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -58.1 KB - Content
- image-20220831161356-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -27.0 KB - Content