Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
From version 145.1
edited by Ben
on 2022/08/31 16:15
on 2022/08/31 16:15
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 24 added, 0 removed)
- image-20220831163041-1.png
- image-20220831163406-2.png
- image-20220831163422-3.png
- image-20220831163441-4.png
- image-20220831163548-5.png
- image-20220831163553-6.png
- image-20220831163923-7.png
- image-20220831164626-1.png
- image-20220831164646-2.png
- image-20220831164700-3.png
- image-20220831164731-4.png
- image-20220831165008-1.png
- image-20220831165017-2.png
- image-20220831165031-3.png
- image-20220831165238-4.png
- image-20220831170147-1.png
- image-20220831170215-2.png
- image-20220831170254-3.png
- image-20220831170306-4.png
- image-20220831171127-1.png
- image-20220902104329-1.png
- image-20220902111121-1.png
- image-20220902111754-2.png
- image-20220902111833-3.png
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki.B en1 +XWiki.Bob - Content
-
... ... @@ -182,7 +182,7 @@ 182 182 183 183 MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 184 184 185 -**1) PLCSettings**185 +**1)V-BOX setting** 186 186 187 187 |**Item**|**Settings**|**Note** 188 188 |Protocol|Allen-Bradlley DF1 Advanced| ... ... @@ -436,7 +436,7 @@ 436 436 437 437 Supported Series: Siemens S7-300 series PLC 438 438 439 -**1) PLCSetting**439 +**1)V-BOX setting** 440 440 441 441 |**Items**|**Settings**|**Note** 442 442 |Protocol|Simens S7-300 Ethernet| ... ... @@ -498,7 +498,7 @@ 498 498 499 499 Supported Series: Siemens S7-400, S7-1200 and S7-1500 500 500 501 -**1) PLCSetting**501 +**1)V-BOX setting** 502 502 503 503 |=**Items**|=**Settings**|=**Note** 504 504 |Protocol|Siemens S7-XXX| ... ... @@ -704,6 +704,98 @@ 704 704 [[image:image-20220825100845-4.png]] 705 705 706 706 707 +== ** FX3U Ethernet Protocol** == 708 + 709 +Mitsubishi FX3U series PLC 710 + 711 +**HMI Settings** 712 + 713 +|Items|Settings|Note 714 +|Protocol|Mitsubishi FX3U| 715 +|Connection|Ethernet| 716 +|Port No.|5009|Must be the same as the PLC setting 717 +|PLC station No.|0| 718 + 719 +**Address List** 720 + 721 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 722 +|(% colspan="1" rowspan="7" %)Bit|X|X|X OOO|0~~377| 723 +|Y|Y|Y OOO|0~~377| 724 +|M|M|M DDDD|0~~7679| 725 +|SM|SM|SM DDDD|8000~~8511| 726 +|S|S|S DDDD|0~~4095| 727 +|TS|TS|TS DDD|0~~511| 728 +|CS|CS|CS DDD|0~~255| 729 +|(% colspan="1" rowspan="9" %)Word|CN|CN|CN DDD|0~~199| 730 +|TN|TN|TN DDD|0~~511| 731 +|D|D|D DDDD|0~~7999| 732 +|SD|SD|SD DDDD|8000~~8511| 733 +|R|R|R DDDDD|0~~32767| 734 + 735 +**Ethernet Module Settings** 736 + 737 +FX3U-ENET-L module configuration 738 +Set up the FX3U-ENET-L Ethernet module settings as follows. 739 +Select the module location, which in this document is Module 0. 740 + 741 +[[image:image-20221115140802-1.png]] 742 + 743 +Select "Operational setting" to enter the following screen. 744 + 745 +The Ethernet module IP is set to 192.168.39.254 in this document, and other options are default. 746 + 747 +[[image:image-20221115142728-4.png]] 748 + 749 +Select "Open setting" to enter the setting interface, the settings are as follows. 750 + 751 +The third item "Protocol" selects TCP, and "Open system" selects MELSOFT connection, which allows the 752 + 753 +Mitsubishi programming software GX works2 to communicate with the FX3U via the Ethernet module. 754 + 755 +[[image:image-20221115142945-5.png]] 756 + 757 +Click on "transter setup" - "PC side I/F setting", see the following figure. 758 + 759 +After setting, the first download must use the programming cable, as shown in the figure; after that, can 760 + 761 +use the IP set in the "Ethernet board" to communicate directly with the network cable. 762 + 763 +[[image:image-20221115143341-6.png||height="426" width="712"]] 764 + 765 +Read and write data from the Ethernet module 766 + 767 +[[image:image-20221115143703-7.png]] 768 + 769 +Set "Transter setup" to COM communication, and read or write operation as shown below 770 + 771 +[[image:image-20221115143809-8.png]] 772 + 773 +**PLC Settings (GX Works 2)** 774 + 775 +Create a blank FX5U project 776 + 777 +Find Current Connection in the navigation 778 + 779 +[[image:image-20221115144335-9.png||height="422" width="706"]] 780 + 781 +Select Connection Channel List 782 + 783 +Select Ethernet board communication 784 + 785 +[[image:image-20221115144824-10.png||height="421" width="705"]] 786 + 787 +Select Ethernet Module 788 +Set the IP address of the PLC 789 + 790 +[[image:image-20221115145228-11.png||height="674" width="708"]] 791 + 792 +Read or write PLC data, in this document is read 793 + 794 +[[image:image-20221115145553-12.png||height="424" width="711"]] 795 + 796 +[[image:image-20221115145559-13.png||height="424" width="711"]] 797 + 798 + 707 707 == **FX5U Serial Protocol** == 708 708 709 709 Mitsubishi FX5U series PLC ... ... @@ -1194,66 +1194,362 @@ 1194 1194 * Please set the communication delay time of 10ms in setting, to avoid that the instrument may not be able to communicate in a short time due to too fast data access and too much connection requests. 1195 1195 * [[image:image-20220831161356-1.png]]Because of the particularity of the instrument, it is necessary to write the value of the address in the menu interface corresponding to the address, and to enter the menu where the address locates, so that the value could be written. 1196 1196 1197 -= =**EtherNet/IPNXseriesProtocol** ==1289 += Create communication with Xinje** PLC** = 1198 1198 1199 - Supportedseries:OmronNX/NJ series1291 +== **XC serial protocol** == 1200 1200 1201 -** HMISetting**1293 +**1)V-BOX Settings** 1202 1202 1203 -|**Items**|**Settings**|**Note** 1204 -|Protocol|Omron NX Ethernet/IP| 1205 -|Connection|Ethernet| 1206 -|Port No.|44818| 1295 +|**Item**|**Settings**|**Note** 1296 +|Protocol|XINJE XC MODBUS| 1297 +|Connection|RS232| 1298 +|Baud rate|19200| 1299 +|Data bit|8| 1300 +|Parity|EVEN| 1301 +|Stop bit|1| 1207 1207 |PLC station No.|1| 1208 1208 1209 -** Instruction**1304 +**2)Address List** 1210 1210 1211 -1) In Sysmac Studio, please select [Publish Only] for [Network Publish] when setting address tag. 1306 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 1307 +|Bit|M|M|M d|0~~8511| 1308 +|Bit|X|X|X o|0~~1747| 1309 +|Bit|Y|Y|Y o|0~~1747| 1310 +|Bit|S|S|S d|0~~1023| 1311 +|Bit|T|T|T d|0~~4095| 1312 +|Bit|C|C|C d|0~~634| 1313 +|Word|D|D|D d|0~~8511| 1314 +|Word|TD|TD|TD d|0~~618| 1315 +|Word|CD|CD|CD d|0~~634| 1316 +|Word|FD|FD|FD d|0~~8511| 1212 1212 1213 - 2) When [Doot publish] is selectedfor a tag, different import methods may lead to different results. When import tags by [GetTags from Device],thetag will be eliminated. If [Import tags] is selected, the tags will be imported, but the communicationwill notsucceed.1318 +**3)Configure the communication protocol** 1214 1214 1215 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_4156caf6f116c570.png?width=600&height=277&rev=1.1||alt="12.PLC Protocol_html_4156caf6f116c570.png" height="277" width="600"]] 1216 1216 1217 - **Export labels fromSysmac Studio**1321 +[[image:image-20220831163041-1.png]] 1218 1218 1219 - Launch Sysmac Studio, under GlobalVariablescreate the address labels, and thenselect [Tools] -> [Export Global Variables];1323 +**4)Cable Wiring** 1220 1220 1221 - [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_26f91dee66c723e9.png?width=600&height=276&rev=1.1||alt="12.PLC Protocol_html_26f91dee66c723e9.png" height="276" width="600"]]1325 +Figure 1222 1222 1223 - Launch PIStudio, in[Communication] Settingsadd Omron NX Ethernet/IPprotocol;1327 +[[image:image-20220831163406-2.png]][[image:image-20220831163422-3.png]] 1224 1224 1225 - Click[Labelmanage];1329 +Pin Definition Diagram 1226 1226 1227 -[[image: https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_cd38d2d0c5187f6b.png?width=600&height=276&rev=1.1||alt="12.PLC Protocol_html_cd38d2d0c5187f6b.png" height="276" width="600"]]1331 +[[image:image-20220831163441-4.png]] 1228 1228 1229 - Click[Importlabels] and then select the fileexportedin step 1;1333 +== **XD serial protocol** == 1230 1230 1231 - [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_52bd5da678bef9b4.png?width=600&height=403&rev=1.1||alt="12.PLC Protocol_html_52bd5da678bef9b4.png" height="403" width="600"]]1335 +**1)V-BOX Settings** 1232 1232 1233 - The ImportStatus fieldshows theult,click [OK]tofinishimportingaddresslabels;1337 +Supported Series: Delta Xinjie XD/XE Series PLC 1234 1234 1235 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_7f0465a589b98912.png?width=600&height=291&rev=1.1||alt="12.PLC Protocol_html_7f0465a589b98912.png" height="291" width="600"]] 1339 +|**Item**|**Settings**|**Note** 1340 +|Protocol|XINJE XD/XC MODBUS| 1341 +|Connection|RS232| 1342 +|Baud rate|19200| 1343 +|Data bit|8| 1344 +|Parity|EVEN| 1345 +|Stop bit|1| 1346 +|PLC station No.|1| 1236 1236 1237 -** Communication Settings**1348 +**2)Address List** 1238 1238 1239 -Enable HMI Ethernet in [Project Settings]; 1350 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 1351 +|Bit|M|M|M d|0~~74999| 1352 +|Bit|X1xx|X1xx|X1xx o|0~~1177| 1353 +|Bit|X2xx|X2xx|X2xx o|0~~277| 1354 +|Bit|X|X|X o|0~~77| 1355 +|Bit|Y1xx|Y1xx|Y1xx o|0~~1177| 1356 +|Bit|Y2xx|Y2xx|Y2xx o|0~~277| 1357 +|Bit|Y|Y|Y o|0~~4095| 1358 +|Bit|SM|SM|SM d|0~~4999|((( 1359 + 1360 +))) 1361 +|Bit|T|T|T d|0~~4999| 1362 +|Bit|C|C|C d|0~~4999| 1363 +|Bit|ET|ET|ET d|0~~31| 1364 +|Bit|SE|SE|SE d|0~~31| 1365 +|Bit|HM|HM|HM d|0~~11999| 1366 +|Bit|HSC|HSC|HSC d|0~~39| 1367 +|Bit|HS|HS|HS d|0~~999| 1368 +|Bit|HT|HT|HT d|0~~1999| 1369 +|Bit|HC|HC|HC d|0~~1999| 1370 +|Bit|S|S|S d|0~~7999| 1371 +|Word|D|D|D d|0~~69999| 1372 +|Word|ID|ID|ID d|0~~99| 1373 +|Word|ID1xx|ID1xx|ID1xx d|0~~999| 1374 +|Word|ID2xx|ID2xx|ID2xx d|0~~299| 1375 +|Word|QD|QD|QD d|0~~99| 1376 +|Word|QD1xx|QD1xx|QD1xx d|0~~999| 1377 +|Word|QD2xx|QD2xx|QD2xx d|0~~299| 1378 +|Word|SD|SD|SD d|0~~4999| 1379 +|Word|TD|TD|TD d|0~~575| 1380 +|Word|CD|CD|CD d|0~~575| 1381 +|Word|ETD|ETD|ETD d|0~~31| 1382 +|Word|HD|HD|HD d|0~~24999| 1383 +|Word|HSD|HSD|HSD d|0~~1023| 1384 +|Word|HTD|HTD|HTD d|0~~95| 1385 +|Word|HCD|HCD|HCD d|0~~95| 1386 +|Word|HSCD|HSCD|HSCD d|0~~31| 1387 +|Word|FD|FD|FD d|0~~8191| 1388 +|Word|SFD|SFD|SFD d|0~~5999| 1389 +|Word|FS|FS|FS d|0~~47| 1240 1240 1241 - [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_43b671f18153910d.png?width=405&height=107&rev=1.1||alt="12.PLCProtocol_html_43b671f18153910d.png" height="107" width="405"]]1391 +**3)Configure the communication protocol** 1242 1242 1243 - Set PLC IP in[DeviceIP] settings;1393 +[[image:image-20220831163923-7.png]] 1244 1244 1245 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_437cb087b36b5784.png?width=600&height=330&rev=1.1||alt="12.PLC Protocol_html_437cb087b36b5784.png" height="330" width="600"]] 1246 1246 1247 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_60ef71528a99abf5.png?width=554&height=188&rev=1.1||alt="12.PLC Protocol_html_60ef71528a99abf5.png" height="188" width="554"]] 1248 1248 1249 -**Cable Wiring** 1397 +**4)Cable Wiring** 1250 1250 1251 - [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]1399 +Figure 1252 1252 1253 - = Createcommunicationwith **Modbus RTU** =1401 +[[image:image-20220831163406-2.png]][[image:image-20220831163553-6.png]] 1254 1254 1255 - ==**V-BOXas Slave** ==1403 +Pin Definition Diagram 1256 1256 1405 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830160232-3.png?rev=1.1||alt="image-20220830160232-3.png"]] 1406 + 1407 + 1408 += Create communication with **Schneider PLC** = 1409 + 1410 +== **Schneider MODBUS RTU** == 1411 + 1412 +**1)V-BOX Setting** 1413 + 1414 +|=**Parameters**|=**Recommended**|=**Notes** 1415 +|**Protocol**|(% colspan="1" %)Schneider MODBUS RTU| 1416 +|**Connection**|RS485| 1417 +|**Baud rate**|19200| 1418 +|**Data bit**|8| 1419 +|**Parity**|Even| 1420 +|**Stop bit**|1| 1421 +|**PLC station No.**|1| 1422 + 1423 +**2)Address List** 1424 + 1425 +|=**Bit/Word**|=**Device type**|=**Format**|=**Range**|=**Memo** 1426 +|B|IX|DDDDDo|0 ~~ 655357|Input bit (read only) 1427 +|B|QX|DDDDDo|0 ~~ 655357|Write multiple coils 1428 +|B|MX|DDDDDDo|0 ~~ 9999997|Output register bit (octal) 1429 +|W|MW|DDDDDD|0 ~~ 999999|Output register 1430 +|DW|MD|DDDDDD|0 ~~ 999999|Output register 1431 + 1432 +**3)Configure the communication protocol** 1433 + 1434 +[[image:image-20220902104329-1.png]] 1435 + 1436 +**4)Cable Wiring** 1437 + 1438 +**RS-485 2W **(RJ45 Connector): The following is the view from the soldering point of a connector. 1439 + 1440 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220817154212-1.jpeg?width=554&height=315&rev=1.1||alt="image-20220817154212-1.jpeg" height="315" width="554"]] 1441 + 1442 += Create communication with Inovance** PLC** = 1443 + 1444 +== **H3U serial protocol** == 1445 + 1446 +**1)V-BOX Settings** 1447 + 1448 +|**Item**|**Settings**|**Note** 1449 +|Protocol|INOVANCE H3U PLC| 1450 +|Connection|RS422| 1451 +|Baud rate|9600| 1452 +|Data bit|7| 1453 +|Parity|EVEN| 1454 +|Stop bit|1| 1455 +|PLC station No.|0| 1456 + 1457 +**2)Address List** 1458 + 1459 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 1460 +|Bit|X|X|X o|0~~303237| 1461 +|Bit|Y|Y|Y o|0~~303237| 1462 +|Bit|M|M|M d|0~~99999| 1463 +|Bit|T|T|T d|0~~99999| 1464 +|Bit|C|C|C d|0~~99999| 1465 +|Bit|SM|SM|SM d|8000~~999| 1466 +|Bit|S|T|S d|0~~99999| 1467 +|Bit|Lamp|Lamp|Lamp d|0~~0| 1468 +|Word|X|X|X o|0~~303237| 1469 +|Word|Y|Y|Y o|0~~303237| 1470 +|Word|M|M|M d|0~~99999| 1471 +|Word|T|T|T d|0~~99999| 1472 +|Word|C|C|C d|0~~199| 1473 +|Word|D|D|D d|0~~7999| 1474 +|Word|S|S|S d|0~~99999| 1475 +|Word|SD|SD|SD d|8000~~9999| 1476 +|Word|R|R|R d|0~~32767| 1477 + 1478 +**3)Configure the communication protocol** 1479 + 1480 +[[image:image-20220831164626-1.png]] 1481 + 1482 + 1483 + 1484 +**4)Cable Wiring** 1485 + 1486 +Figure 1487 + 1488 +[[image:image-20220831164646-2.png]][[image:image-20220831164700-3.png]] 1489 + 1490 +Pin Definition Diagram 1491 + 1492 +[[image:image-20220831164731-4.png]] 1493 + 1494 += Create communication with Panasonic** PLC** = 1495 + 1496 +== **FP serial protocol** == 1497 + 1498 +**1)V-BOX Settings** 1499 + 1500 +|**Item**|**Settings**|**Note** 1501 +|Protocol|Panasonic FP MFWTOCOL| 1502 +|Connection|RS232| 1503 +|Baud rate|9600| 1504 +|Data bit|8| 1505 +|Parity|ODD| 1506 +|Stop bit|1| 1507 +|PLC station No.|1| 1508 + 1509 +**2)Address List** 1510 + 1511 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 1512 +|Bit|X|X|X d|0~~9999| 1513 +|Bit|Y|Y|Y d|0~~9999| 1514 +|Bit|R|R|R d|0~~9999| 1515 +|Bit|T|T|T d|0~~9999| 1516 +|Bit|C|C|C d|0~~9999| 1517 +|Bit|L|L|L d|0~~9999| 1518 +|Word|WX|WX|WX d|0~~9999| 1519 +|Word|WY|WY|WY d|0~~9999| 1520 +|Word|WR|WR|WR d|0~~9999| 1521 +|Word|WL|WL|WL d|0~~9999| 1522 +|Word|LD|LD|LD d|0~~9999| 1523 +|Word|DT|DT|DT d|0~~65535| 1524 +|Word|FL|FL|FL d|0~~9999| 1525 +|Word|EV|EV|EV d|0~~9999| 1526 +|Word|SV|SV|SV d|0~~9999| 1527 + 1528 +**3)Configure the communication protocol** 1529 + 1530 +[[image:image-20220831165238-4.png]] 1531 + 1532 + 1533 + 1534 +**4)Cable Wiring** 1535 + 1536 +Figure 1537 + 1538 +[[image:image-20220831165031-3.png]][[image:image-20220831165017-2.png]] 1539 + 1540 +Pin Definition Diagram 1541 + 1542 +[[image:image-20220831165008-1.png]] 1543 + 1544 += Create communication with LS** PLC** = 1545 + 1546 +== **XBC serial protocol** == 1547 + 1548 +**1)V-BOX Settings** 1549 + 1550 +|**Item**|**Settings**|**Note** 1551 +|Protocol|LS XBC CNet| 1552 +|Connection|RS232| 1553 +|Baud rate|115200| 1554 +|Data bit|8| 1555 +|Parity|NONE| 1556 +|Stop bit|1| 1557 +|PLC station No.|1| 1558 + 1559 +**2)Address List** 1560 + 1561 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 1562 +|Bit|P|P|P d|0~~2047| 1563 +|Bit|M|M|M d|0~~2047| 1564 +|Bit|L|L|L d|0~~11263| 1565 +|Bit|K|K|K d|0~~16183| 1566 +|Bit|F|F|F d|0~~2047| 1567 +|Bit|D|D|D d|0~~32767| 1568 +|Bit|R|R|R d|0~~32767| 1569 +|Bit|U|U|U d|0~~4095| 1570 +|Word|P|P|P d|0~~2047| 1571 +|Word|M|M|M d|0~~2047| 1572 +|Word|L|L|L d|0~~11263| 1573 +|Word|K|K|K d|0~~16183| 1574 +|Word|F|F|F d|0~~2047| 1575 +|Word|C|C|C d|0~~2047| 1576 +|Word|T|T|T d|0~~2047| 1577 +|Word|D|D|D d|0~~32767| 1578 +|Word|N|N|N d|0~~21503| 1579 +|Word|R|R|R d|0~~32767| 1580 +|Word|U|U|U d|0~~4095| 1581 +|Word|Z|Z|Z d|0~~127| 1582 +|Word|S|S|S d|0~~127| 1583 + 1584 +**3)Configure the communication protocol** 1585 + 1586 +[[image:image-20220831170147-1.png]] 1587 + 1588 +**4)Cable Wiring** 1589 + 1590 +Figure 1591 + 1592 +[[image:image-20220831170306-4.png]][[image:image-20220831170254-3.png]] 1593 + 1594 +Pin Definition Diagram 1595 + 1596 +[[image:image-20220831170215-2.png]] 1597 + 1598 +== **XGK FEnet Ethernet protocol** == 1599 + 1600 +Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module 1601 + 1602 +**1)V-BOX Settings** 1603 + 1604 +|**Items**|**Settings**|**Note** 1605 +|Protocol|LG XGK FEnet(Ethernet)| 1606 +|Connection|Ethernet| 1607 +|Port No.|2004| 1608 + 1609 +**2)Address List** 1610 + 1611 +|**Type**|**Register**|**Range**|**Format**|**Note** 1612 +|(% rowspan="14" %)Word|P|0~~2047|P d| 1613 +|M|0~~2047|M d| 1614 +|K|0~~2047|K d| 1615 +|F|0~~2047|F d| 1616 +|T|0~~2047|T d| 1617 +|C|0~~2047|C d| 1618 +|Z|0~~127|Z d| 1619 +|S|0~~127|S d| 1620 +|L|0~~11263|L d| 1621 +|N|0~~21503|N d| 1622 +|D|0~~32767|D d| 1623 +|R|0~~32767|R d| 1624 +|ZR|0~~65535|ZR d| 1625 +|UxDD|0~~6331|UxDD nndd|nn: 0~~63, dd: 0~~31 1626 + 1627 +**✎Note:** 1628 + 1629 +* In addition to the "UxDD" register, the others correspond to the PLC register one by one. UxDD corresponds to U in the PLC; 1630 +* The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC; 1631 +* All bit registers are in the form of bits in word, and the range is the same as the word register; 1632 + 1633 +**3)Communication Settings** 1634 + 1635 +[[image:image-20220831171127-1.png]] 1636 + 1637 +**4)Cable Wiring** 1638 + 1639 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 1640 + 1641 += Create communication with **Modbus ** = 1642 + 1643 +== **MODBUS RTU Slave (All function)** == 1644 + 1257 1257 Select the protocol "Modbus RTU Slave (All Fuction)", 1258 1258 1259 1259 Then set baud rate, port, stop bits, data bits, parity. ... ... @@ -1261,7 +1261,7 @@ 1261 1261 (% style="text-align:center" %) 1262 1262 [[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]] 1263 1263 1264 -== ** V-BOXasMaster** ==1652 +== **MODBUS RTU Master** == 1265 1265 1266 1266 Select the protocol "Modbus RTU Master", 1267 1267 ... ... @@ -1297,6 +1297,61 @@ 1297 1297 |(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils) 1298 1298 |0F (Write multiple bits) 1299 1299 1688 +== **MODBUS TCP Slave (All function)** == 1689 + 1690 +Supported series: MODBUS TCP controller 1691 + 1692 +V-B0X works as MODBUS TCP MASTER connecting with TCP SLAVE 1693 + 1694 +**1)V-BOX Setting** 1695 + 1696 +|**Items**|**Settings**|**Note** 1697 +|Protocol|MODBUS TCP Slave (All function)| 1698 +|Connection|Ethernet| 1699 +|Port No.|502| 1700 +|PLC station No.|1 1701 + 1702 +**2)Address List** 1703 + 1704 +|**Type**|**Register**|**Function code & Description** 1705 +|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers) 1706 +|06 (write single register: write a binary value to a holding register) 1707 +|10 (write values to multiple addresses ) 1708 +|(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers) 1709 +|06 (write single register: write a binary value to a holding register) 1710 +|10 (write values to multiple addresses ) 1711 +|(% rowspan="3" %)W6|03 (read holding register: read current binary value in one or more holding registers) 1712 +|06 (write single register: write a binary value to a holding register) 1713 +|10 (write values to multiple addresses ) 1714 +|(% rowspan="2" %)W16|03 (read holding register: read current binary value in one or more holding registers) 1715 +|10 (write values to multiple addresses ) 1716 +|(% rowspan="11" %)Bit|(% rowspan="3" %)0|01 (Read coil state) 1717 +|05 (Force a single coil to force the on/off state of a logic coil) 1718 +|0F (Write multiple bits, ie write continuously) 1719 +|(% rowspan="3" %)1|02 (Read the input state) 1720 +|05 (Force a single coil to force the on/off state of a logic coil) 1721 +|0F (Write multiple bits) 1722 +|(% rowspan="3" %)W5|01 (Read coil state to obtain the current state of a set of logic coils) 1723 +|05 (Force a single coil to force the on/off state of a logic coil) 1724 +|0F (Write multiple bits) 1725 +|(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils) 1726 +|0F (Write multiple bits) 1727 + 1728 +**3)Communication Settings** 1729 + 1730 +Configure V-BOX Ethernet IP in Networking Settings 1731 + 1732 +[[image:image-20220902111833-3.png]] 1733 + 1734 + 1735 +Configure PLC Ethernet IP in Communication; 1736 + 1737 +[[image:image-20220902111121-1.png]] 1738 + 1739 +**4)Cable Wiring** 1740 + 1741 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 1742 + 1300 1300 == **communicate with VB inverter** == 1301 1301 1302 1302 [[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20VB%20inverter.zip]]
- image-20220831163041-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +58.6 KB - Content
- image-20220831163406-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +28.4 KB - Content
- image-20220831163422-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +53.9 KB - Content
- image-20220831163441-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.7 KB - Content
- image-20220831163548-5.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +37.1 KB - Content
- image-20220831163553-6.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +37.1 KB - Content
- image-20220831163923-7.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +57.3 KB - Content
- image-20220831164626-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +56.1 KB - Content
- image-20220831164646-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +28.4 KB - Content
- image-20220831164700-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +66.6 KB - Content
- image-20220831164731-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +12.3 KB - Content
- image-20220831165008-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.3 KB - Content
- image-20220831165017-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +36.2 KB - Content
- image-20220831165031-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +28.3 KB - Content
- image-20220831165238-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +57.4 KB - Content
- image-20220831170147-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +57.1 KB - Content
- image-20220831170215-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +14.3 KB - Content
- image-20220831170254-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +43.5 KB - Content
- image-20220831170306-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +28.5 KB - Content
- image-20220831171127-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +60.1 KB - Content
- image-20220902104329-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +58.7 KB - Content
- image-20220902111121-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +60.9 KB - Content
- image-20220902111754-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +57.6 KB - Content
- image-20220902111833-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +56.1 KB - Content