Changes for page 1 Communication

Last modified by Hunter on 2024/07/01 10:54

From version 149.1
edited by Ben
on 2022/08/31 16:39
Change comment: There is no comment for this version
To version 166.1
edited by Bob
on 2022/11/16 09:32
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Ben
1 +XWiki.Bob
Content
... ... @@ -182,7 +182,7 @@
182 182  
183 183  MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
184 184  
185 -**1)PLC Settings**
185 +**1)V-BOX setting**
186 186  
187 187  |**Item**|**Settings**|**Note**
188 188  |Protocol|Allen-Bradlley DF1 Advanced|
... ... @@ -436,7 +436,7 @@
436 436  
437 437  Supported Series: Siemens S7-300 series PLC
438 438  
439 -**1)PLC Setting**
439 +**1)V-BOX setting**
440 440  
441 441  |**Items**|**Settings**|**Note**
442 442  |Protocol|Simens S7-300 Ethernet|
... ... @@ -498,7 +498,7 @@
498 498  
499 499  Supported Series: Siemens S7-400, S7-1200 and S7-1500
500 500  
501 -**1)PLC Setting**
501 +**1)V-BOX setting**
502 502  
503 503  |=**Items**|=**Settings**|=**Note**
504 504  |Protocol|Siemens S7-XXX|
... ... @@ -704,6 +704,97 @@
704 704  [[image:image-20220825100845-4.png]]
705 705  
706 706  
707 +== ** FX3U Ethernet Protocol** ==
708 +
709 +Mitsubishi FX3U series PLC
710 +
711 +**HMI Settings**
712 +
713 +|Items|Settings|Note
714 +|Protocol|Mitsubishi FX3U|
715 +|Connection|Ethernet|
716 +|Port No.|5009|Must be the same as the PLC setting
717 +|PLC station No.|0|
718 +
719 +**Address List**
720 +
721 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
722 +|(% colspan="1" rowspan="7" %)Bit|X|X|X OOO|0~~377|
723 +|Y|Y|Y OOO|0~~377|
724 +|M|M|M DDDD|0~~7679|
725 +|SM|SM|SM DDDD|8000~~8511|
726 +|S|S|S DDDD|0~~4095|
727 +|TS|TS|TS DDD|0~~511|
728 +|CS|CS|CS DDD|0~~255|
729 +|(% colspan="1" rowspan="9" %)Word|CN|CN|CN DDD|0~~199|
730 +|TN|TN|TN DDD|0~~511|
731 +|D|D|D DDDD|0~~7999|
732 +|SD|SD|SD DDDD|8000~~8511|
733 +|R|R|R DDDDD|0~~32767|
734 +
735 +**Ethernet Module Settings**
736 +
737 +FX3U-ENET-L module configuration
738 +Set up the FX3U-ENET-L Ethernet module settings as follows.
739 +Select the module location, which in this document is Module 0.
740 +
741 +[[image:image-20221115140802-1.png]]
742 +
743 +Select "Operational setting" to enter the following screen.
744 +
745 +The Ethernet module IP is set to 192.168.39.254 in this document, and other options are default.
746 +
747 +[[image:image-20221115142728-4.png]]
748 +
749 +Select "Open setting" to enter the setting interface, the settings are as follows.
750 +
751 +The third item "Protocol" selects TCP, and "Open system" selects MELSOFT connection, which allows the
752 +
753 +Mitsubishi programming software GX works2 to communicate with the FX3U via the Ethernet module.
754 +
755 +[[image:image-20221115142945-5.png]]
756 +
757 +Click on "transter setup" - "PC side I/F setting", see the following figure.
758 +
759 +After setting, the first download must use the programming cable, as shown in the figure; after that, can
760 +
761 +use the IP set in the "Ethernet board" to communicate directly with the network cable.
762 +
763 +[[image:image-20221115143341-6.png||height="426" width="712"]]
764 +
765 +Read and write data from the Ethernet module
766 +
767 +[[image:image-20221115143703-7.png]]
768 +
769 +Set "Transter setup" to COM communication, and read or write operation as shown below
770 +
771 +[[image:image-20221115143809-8.png]]
772 +
773 +**PLC Settings (GX Works 2)**
774 +
775 +Create a blank FX5U project
776 +
777 +Find Current Connection in the navigation
778 +
779 +[[image:image-20221115144335-9.png||height="422" width="706"]]
780 +
781 +Select Connection Channel List
782 +
783 +Select Ethernet board communication
784 +
785 +[[image:image-20221115144824-10.png||height="421" width="705"]]
786 +
787 +Select Ethernet Module
788 +Set the IP address of the PLC
789 +
790 +[[image:image-20221115145228-11.png||height="674" width="708"]]
791 +
792 +Read or write PLC data, in this document is read
793 +
794 +[[image:image-20221115145553-12.png||height="424" width="711"]]
795 +
796 +[[image:image-20221115145559-13.png||height="424" width="711"]]
797 +
707 707  == **FX5U Serial Protocol** ==
708 708  
709 709  Mitsubishi FX5U series PLC
... ... @@ -1312,15 +1312,50 @@
1312 1312  
1313 1313  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830160232-3.png?rev=1.1||alt="image-20220830160232-3.png"]]
1314 1314  
1315 -= Create communication with Inovance** PLC**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=37]] =
1316 1316  
1317 -== **H3U serial protocol**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=38]] ==
1407 += Create communication with **Schneider PLC** =
1318 1318  
1319 -**1)HMI Settings**
1409 +== **Schneider MODBUS RTU** ==
1320 1320  
1411 +**1)V-BOX Setting**
1412 +
1413 +|=**Parameters**|=**Recommended**|=**Notes**
1414 +|**Protocol**|(% colspan="1" %)Schneider MODBUS RTU|
1415 +|**Connection**|RS485|
1416 +|**Baud rate**|19200|
1417 +|**Data bit**|8|
1418 +|**Parity**|Even|
1419 +|**Stop bit**|1|
1420 +|**PLC station No.**|1|
1421 +
1422 +**2)Address List**
1423 +
1424 +|=**Bit/Word**|=**Device type**|=**Format**|=**Range**|=**Memo**
1425 +|B|IX|DDDDDo|0 ~~ 655357|Input bit (read only)
1426 +|B|QX|DDDDDo|0 ~~ 655357|Write multiple coils
1427 +|B|MX|DDDDDDo|0 ~~ 9999997|Output register bit (octal)
1428 +|W|MW|DDDDDD|0 ~~ 999999|Output register
1429 +|DW|MD|DDDDDD|0 ~~ 999999|Output register
1430 +
1431 +**3)Configure the communication protocol**
1432 +
1433 +[[image:image-20220902104329-1.png]]
1434 +
1435 +**4)Cable Wiring**
1436 +
1437 +**RS-485 2W **(RJ45 Connector): The following is the view from the soldering point of a connector.
1438 +
1439 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220817154212-1.jpeg?width=554&height=315&rev=1.1||alt="image-20220817154212-1.jpeg" height="315" width="554"]]
1440 +
1441 += Create communication with Inovance** PLC** =
1442 +
1443 +== **H3U serial protocol** ==
1444 +
1445 +**1)V-BOX Settings**
1446 +
1321 1321  |**Item**|**Settings**|**Note**
1322 1322  |Protocol|INOVANCE H3U PLC|
1323 -|Connection|RS22|
1449 +|Connection|RS422|
1324 1324  |Baud rate|9600|
1325 1325  |Data bit|7|
1326 1326  |Parity|EVEN|
... ... @@ -1350,25 +1350,25 @@
1350 1350  
1351 1351  **3)Configure the communication protocol**
1352 1352  
1353 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830170114-4.png?rev=1.1||alt="image-20220830170114-4.png"]]
1479 +[[image:image-20220831164626-1.png]]
1354 1354  
1355 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830170017-3.png?rev=1.1||alt="image-20220830170017-3.png"]]
1356 1356  
1482 +
1357 1357  **4)Cable Wiring**
1358 1358  
1359 1359  Figure
1360 1360  
1361 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830165930-1.png?rev=1.1||alt="image-20220830165930-1.png"]]
1487 +[[image:image-20220831164646-2.png]][[image:image-20220831164700-3.png]]
1362 1362  
1363 1363  Pin Definition Diagram
1364 1364  
1365 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830165947-2.png?rev=1.1||alt="image-20220830165947-2.png"]]
1491 +[[image:image-20220831164731-4.png]]
1366 1366  
1367 -= Create communication with Panasonic** PLC**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=39]] =
1493 += Create communication with Panasonic** PLC** =
1368 1368  
1369 -== **FP serial protocol**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=40]] ==
1495 +== **FP serial protocol** ==
1370 1370  
1371 -**1)HMI Settings**
1497 +**1)V-BOX Settings**
1372 1372  
1373 1373  |**Item**|**Settings**|**Note**
1374 1374  |Protocol|Panasonic FP MFWTOCOL|
... ... @@ -1400,25 +1400,25 @@
1400 1400  
1401 1401  **3)Configure the communication protocol**
1402 1402  
1403 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830171050-1.png?rev=1.1||alt="image-20220830171050-1.png"]]
1529 +[[image:image-20220831165238-4.png]]
1404 1404  
1405 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830171126-2.png?rev=1.1||alt="image-20220830171126-2.png"]]
1406 1406  
1532 +
1407 1407  **4)Cable Wiring**
1408 1408  
1409 1409  Figure
1410 1410  
1411 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830171328-4.png?rev=1.1||alt="image-20220830171328-4.png"]]
1537 +[[image:image-20220831165031-3.png]][[image:image-20220831165017-2.png]]
1412 1412  
1413 1413  Pin Definition Diagram
1414 1414  
1415 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830171146-3.png?rev=1.1||alt="image-20220830171146-3.png"]]
1541 +[[image:image-20220831165008-1.png]]
1416 1416  
1417 -= Create communication with LS** PLC**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=41]] =
1543 += Create communication with LS** PLC** =
1418 1418  
1419 -== **XBC serial protocol**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=42]] ==
1545 +== **XBC serial protocol** ==
1420 1420  
1421 -**1)HMI Settings**
1547 +**1)V-BOX Settings**
1422 1422  
1423 1423  |**Item**|**Settings**|**Note**
1424 1424  |Protocol|LS XBC CNet|
... ... @@ -1456,25 +1456,23 @@
1456 1456  
1457 1457  **3)Configure the communication protocol**
1458 1458  
1459 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830174853-3.png?rev=1.1||alt="image-20220830174853-3.png"]]
1585 +[[image:image-20220831170147-1.png]]
1460 1460  
1461 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830174733-2.png?rev=1.1||alt="image-20220830174733-2.png"]]
1462 -
1463 1463  **4)Cable Wiring**
1464 1464  
1465 1465  Figure
1466 1466  
1467 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830174659-1.png?rev=1.1||alt="image-20220830174659-1.png"]]
1591 +[[image:image-20220831170306-4.png]][[image:image-20220831170254-3.png]]
1468 1468  
1469 1469  Pin Definition Diagram
1470 1470  
1471 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830173402-8.png?rev=1.1||alt="image-20220830173402-8.png"]]
1595 +[[image:image-20220831170215-2.png]]
1472 1472  
1473 -== **XGK FEnet Ethernet protocol**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=43]] ==
1597 +== **XGK FEnet Ethernet protocol** ==
1474 1474  
1475 1475  Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module
1476 1476  
1477 -**HMI Settings**
1601 +**1)V-BOX Settings**
1478 1478  
1479 1479  |**Items**|**Settings**|**Note**
1480 1480  |Protocol|LG XGK FEnet(Ethernet)|
... ... @@ -1481,7 +1481,7 @@
1481 1481  |Connection|Ethernet|
1482 1482  |Port No.|2004|
1483 1483  
1484 -**Address List**
1608 +**2)Address List**
1485 1485  
1486 1486  |**Type**|**Register**|**Range**|**Format**|**Note**
1487 1487  |(% rowspan="14" %)Word|P|0~~2047|P d|
... ... @@ -1505,186 +1505,18 @@
1505 1505  * The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC;
1506 1506  * All bit registers are in the form of bits in word, and the range is the same as the word register;
1507 1507  
1508 -**Communication settings in HMI**
1632 +**3)Communication Settings**
1509 1509  
1510 -Enable HMI Ethernet in [Project Settings];
1634 +[[image:image-20220831171127-1.png]]
1511 1511  
1512 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_43b671f18153910d.png?width=405&height=107&rev=1.1||alt="12.PLC Protocol_html_43b671f18153910d.png" height="107" width="405"]]
1636 +**4)Cable Wiring**
1513 1513  
1514 -Set PLC IP in [Device IP] settings;
1515 -
1516 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_a2a19b5003ad4090.png?width=554&height=189&rev=1.1||alt="12.PLC Protocol_html_a2a19b5003ad4090.png" height="189" width="554"]]
1517 -
1518 -**Cable Wiring**
1519 -
1520 1520  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1521 1521  
1522 -= Create communication with **SHIMADEN PLC**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=44]] =
1640 += Create communication with **Modbus ** =
1523 1523  
1524 -== **FP23 series protocol**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=45]] ==
1642 +== **MODBUS RTU Slave (All function)** ==
1525 1525  
1526 -Supported series: SHIMADEN FP23 series
1527 -
1528 -**HMI Setting**
1529 -
1530 -|**Items**|**Settings**|**Note**
1531 -|Protocol|SHIMADEN FP23 series|
1532 -|Connection|RS485 (9600, 1, 7, EVEN)|
1533 -|Port No.|None|
1534 -|PLC station No.|0|
1535 -
1536 -**Address List**
1537 -
1538 -|**Device address**|**HMI register**|**Address range**|**Type**
1539 -|0040-0043(HEX)|FP040|100064-200067|Read only
1540 -|0100-010B(HEX)|FP100|100256-200267|Read only
1541 -|0110-0142(HEX)|FP110|100272-200322|Read only
1542 -|0182-0252(HEX)|FP182|100386-200594|Write only
1543 -|0280-0281(HEX)|FP280|100640-200641|Read only
1544 -|0300-030B(HEX)|FP300|100768-200779|Read and write
1545 -|0380-039F(HEX)|FP380|100896-200927|Read and write
1546 -|0400-04D7(HEX)|FP400|101024-201239|Read and write
1547 -|0500-05B0(HEX)|FP500|101280-201456|Read and write
1548 -|0600-0670(HEX)|FP600|101536-201814|Read and write
1549 -|0720-0738(HEX)|FP720|101824-201848|Read and write
1550 -|0800-083F(HEX)|FP800|102048-202111|Read and write
1551 -|0900-0952(HEX)|FP900|102304-202386|Read and write
1552 -| |Ctrl|0-2|
1553 -
1554 -**✎Note:**
1555 -
1556 -* The upper 2 bits of the address of the HMI register are taken as the sub address, and the real address is the last four bits (for example, if the address is 100256, then 10 is the sub address as 1, and 0256 is the real address);
1557 -* The address range in the table is only divided by the start and end addresses, and some of the addresses in the range have no corresponding address in FP23;
1558 -* The Ctrl register is used to store the control group number and BCC check mode.
1559 -
1560 -**Ctrl Register Description**
1561 -
1562 -* The Ctrl register is a special register that does not communicate with the temperature controller. User needs to assign value in the screen according to the settings as in the temperature controller.
1563 -* Ctrl0 indicates the setting of the control character, the valid values are 1, 2, 3 respectively, and the corresponding control group is: STX_ETX_CR , STX_ETX_CR LF and @_:_CR .
1564 -* Ctrl1 indicates the BCC block check mode. The valid value range is 1-4. The corresponding check mode is: 1.ADD, 2.ADD_two's cmp, 3.XOR, 4.None;
1565 -* Ctrl3 reserved
1566 -
1567 -**✎Note:**
1568 -
1569 -After reloading the HMI project or restarting the HMI, HMI will reset the value of ctrl0 and ctrl1 as 1, so user need to set these two values to make it the same as it in the temperature controller, then communication will be normal.
1570 -
1571 -**Cable Wiring**
1572 -
1573 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5e9a81a14106da9e.png?width=392&height=223&rev=1.1||alt="12.PLC Protocol_html_5e9a81a14106da9e.png" height="223" width="392"]]
1574 -
1575 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_1897d92be6948d58.png?width=393&height=223&rev=1.1||alt="12.PLC Protocol_html_1897d92be6948d58.png" height="223" width="393"]]
1576 -
1577 -**✎Note:** COM3 only available in PI8000/PI9000 series.
1578 -
1579 -== **SR90 protocol**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=46]] ==
1580 -
1581 -Supported series: SHIMADEN SR90 series
1582 -
1583 -**HMI Setting**
1584 -
1585 -|**Items**|**Settings**|**Note**
1586 -|Protocol|SHIMADEN SR90 protocol|
1587 -|Connection|RS485 (1200, 1, 7, EVEN)|
1588 -|Port No.|None|
1589 -|PLC station No.|0|
1590 -
1591 -**Address List**
1592 -
1593 -|**Device address**|**HMI register**|**Address range**|**Type**
1594 -|0040-0043 (HEX)|SR040|100064-100067|Read only
1595 -|0100-010A(HEX)|SR0100|100256-100266|Read only
1596 -|0182-018C(HEX)|SR0182|100386-100396|Write only
1597 -|0300-04FE(HEX)|SR0300|100768-101278|Write/read
1598 -|0500-050B(HEX)|SR0500|101280-101291|Write/read
1599 -|0590-0611(HEX)|SR0590|101424-101553|Write/read
1600 -|0701-0709(HEX)|SR0701|101793-101801|Write/read
1601 -| |Ctrl|0-2|~-~-
1602 -
1603 -**✎Note:**
1604 -
1605 -* The upper 2 bits of the address of HMIs are taken as the sub address, and the real address is the last four bits (for example, if the address is 100256, then 10 is the sub address as 1, and 0256 is the real address);
1606 -* The address range in the table is only divided by the start and end addresses, and some of the addresses in the range have no corresponding address in SR90;
1607 -* The Ctrl register is used to store the control group number and BCC check mode. See how to use it below;
1608 -
1609 -**Ctrl Register Description**
1610 -
1611 -* The Ctrl register is a special register that does not communicate with the temperature controller. User needs to assign value in the screen according to the settings as in the temperature controller.
1612 -* Ctrl0 indicates the setting of the control character, the valid values are 1, 2, 3 respectively, and the corresponding control group is: STX_ETX_CR , STX_ETX_CR LF and @_:_CR .
1613 -* Ctrl1 indicates the BCC block check mode. The valid value range is 1-4. The corresponding check mode is: 1.ADD, 2.ADD_two's cmp, 3.XOR, 4.None;
1614 -* Ctrl3 reserved
1615 -
1616 -**✎Note:**
1617 -
1618 -After reloading the HMI project or restarting the HMI, HMI will reset the value of ctrl0 and ctrl1 as 1, so user need to set these two values to make it the same as it in the temperature controller, then communication will be normal.
1619 -
1620 -**Cable Wiring**
1621 -
1622 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5e9a81a14106da9e.png?width=392&height=223&rev=1.1||alt="12.PLC Protocol_html_5e9a81a14106da9e.png" height="223" width="392"]]
1623 -
1624 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_1897d92be6948d58.png?width=393&height=223&rev=1.1||alt="12.PLC Protocol_html_1897d92be6948d58.png" height="223" width="393"]]
1625 -
1626 -**✎Note:** COM3 only available in PI8000/PI9000 series.
1627 -
1628 -== **MR13 series(standard protocol)**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=47]] ==
1629 -
1630 -Supported series: SHIMADEN MR13 series
1631 -
1632 -**HMI Setting**
1633 -
1634 -|**Items**|**Settings**|**Note**
1635 -|Protocol|SHIMADEN standard protocol|
1636 -|Connection|RS485 (1200, 1, 7, EVEN)|
1637 -|Port No.|None|
1638 -|PLC station No.|0|
1639 -
1640 -**Address List**
1641 -
1642 -|**Device address**|**HMI register**|**Address range**|**Type**
1643 -|0100-010B(HEX)|MR100|100256-300267|Read only
1644 -|0111-0126(HEX)|MR111|100273-300294|Read only
1645 -|0184-0192(HEX)|MR184|100388-300402|Write only
1646 -|0280-0282(HEX)|MR280|100640-300642|Read only
1647 -|0300-030B(HEX)|MR300|100768-300779|Read/write
1648 -|0314-0317(HEX)|MR314|100788-300791|Read/write
1649 -|031A(HEX)|MR31A|100794-300794|Read/write
1650 -|0320-0321(HEX)|MR320|100800-300801|Read/write
1651 -|0400-0504(HEX)|MR400|101024-301284|Read/write
1652 -|0506(HEX)|MR506|101286-301286|Read/write
1653 -|0510-0514(HEX)|MR510|101296-301300|Read/write
1654 -|0516-0524(HEX)|MR516|101302-301316|Read/write
1655 -|0526(HEX)|MR526|101318-301318|Read/write
1656 -|0580-08C3(HEX)|MR580|101408-302243|Read/write
1657 -|~-~-|Ctrl|0-2|~-~-
1658 -
1659 -**✎Note:**
1660 -
1661 -* The upper 2 bits of the address of the HMI register are taken as the sub address, and the real address is the last four bits (for example, if the address is 100256, then 10 is the sub address as 1, and 0256 is the real address);
1662 -* The address range in the table is only divided by the start and end addresses, and some of the addresses in the range have no corresponding address in MR13;
1663 -* The Ctrl register is used to store the control group number and BCC check mode.
1664 -
1665 -**Ctrl Register Description**
1666 -
1667 -* The Ctrl register is a special register that does not communicate with the temperature controller. User needs to assign value in the screen according to the settings as in the temperature controller.
1668 -* Ctrl0 indicates the setting of the control character, the valid values are 1, 2, 3 respectively, and the corresponding control group is: STX_ETX_CR, STX_ETX_CR LF and @_:_CR .
1669 -* Ctrl1 indicates the BCC block check mode. The valid value range is 1-4. The corresponding check mode is: 1.ADD, 2.ADD_two's cmp, 3.XOR, 4.None;
1670 -* Ctrl3 reserved
1671 -
1672 -**✎Note:**
1673 -
1674 -After reloading project or restarting the HMI, HMI will reset the value of ctrl0 and ctrl1 as 1, so user need to set these two values to make it the same as it in the temperature controller, then communication will be normal.
1675 -
1676 -**Cable Wiring**
1677 -
1678 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5e9a81a14106da9e.png?width=392&height=223&rev=1.1||alt="12.PLC Protocol_html_5e9a81a14106da9e.png" height="223" width="392"]]
1679 -
1680 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_1897d92be6948d58.png?width=393&height=223&rev=1.1||alt="12.PLC Protocol_html_1897d92be6948d58.png" height="223" width="393"]]
1681 -
1682 -**✎Note:** COM3 only available in PI8000/PI9000 series.
1683 -
1684 -= Create communication with **Modbus RTU** =
1685 -
1686 -== **V-BOX as Slave** ==
1687 -
1688 1688  Select the protocol "Modbus RTU Slave (All Fuction)",
1689 1689  
1690 1690  Then set baud rate, port, stop bits, data bits, parity.
... ... @@ -1692,7 +1692,7 @@
1692 1692  (% style="text-align:center" %)
1693 1693  [[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]]
1694 1694  
1695 -== **V-BOX as Master** ==
1651 +== **MODBUS RTU Master** ==
1696 1696  
1697 1697  Select the protocol "Modbus RTU Master",
1698 1698  
... ... @@ -1728,6 +1728,61 @@
1728 1728  |(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils)
1729 1729  |0F (Write multiple bits)
1730 1730  
1687 +== **MODBUS TCP Slave (All function)** ==
1688 +
1689 +Supported series: MODBUS TCP controller
1690 +
1691 +V-B0X works as MODBUS TCP MASTER connecting with TCP SLAVE
1692 +
1693 +**1)V-BOX Setting**
1694 +
1695 +|**Items**|**Settings**|**Note**
1696 +|Protocol|MODBUS TCP Slave (All function)|
1697 +|Connection|Ethernet|
1698 +|Port No.|502|
1699 +|PLC station No.|1
1700 +
1701 +**2)Address List**
1702 +
1703 +|**Type**|**Register**|**Function code & Description**
1704 +|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers)
1705 +|06 (write single register: write a binary value to a holding register)
1706 +|10 (write values to multiple addresses )
1707 +|(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers)
1708 +|06 (write single register: write a binary value to a holding register)
1709 +|10 (write values to multiple addresses )
1710 +|(% rowspan="3" %)W6|03 (read holding register: read current binary value in one or more holding registers)
1711 +|06 (write single register: write a binary value to a holding register)
1712 +|10 (write values to multiple addresses )
1713 +|(% rowspan="2" %)W16|03 (read holding register: read current binary value in one or more holding registers)
1714 +|10 (write values to multiple addresses )
1715 +|(% rowspan="11" %)Bit|(% rowspan="3" %)0|01 (Read coil state)
1716 +|05 (Force a single coil to force the on/off state of a logic coil)
1717 +|0F (Write multiple bits, ie write continuously)
1718 +|(% rowspan="3" %)1|02 (Read the input state)
1719 +|05 (Force a single coil to force the on/off state of a logic coil)
1720 +|0F (Write multiple bits)
1721 +|(% rowspan="3" %)W5|01 (Read coil state to obtain the current state of a set of logic coils)
1722 +|05 (Force a single coil to force the on/off state of a logic coil)
1723 +|0F (Write multiple bits)
1724 +|(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils)
1725 +|0F (Write multiple bits)
1726 +
1727 +**3)Communication Settings**
1728 +
1729 +Configure V-BOX Ethernet IP in Networking Settings
1730 +
1731 +[[image:image-20220902111833-3.png]]
1732 +
1733 +
1734 +Configure PLC Ethernet IP in Communication;
1735 +
1736 +[[image:image-20220902111121-1.png]]
1737 +
1738 +**4)Cable Wiring**
1739 +
1740 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1741 +
1731 1731  == **communicate with VB inverter** ==
1732 1732  
1733 1733  [[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20VB%20inverter.zip]]
image-20220831164626-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +56.1 KB
Content
image-20220831164646-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +28.4 KB
Content
image-20220831164700-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +66.6 KB
Content
image-20220831164731-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +12.3 KB
Content
image-20220831165008-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +13.3 KB
Content
image-20220831165017-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +36.2 KB
Content
image-20220831165031-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +28.3 KB
Content
image-20220831165238-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +57.4 KB
Content
image-20220831170147-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +57.1 KB
Content
image-20220831170215-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +14.3 KB
Content
image-20220831170254-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +43.5 KB
Content
image-20220831170306-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +28.5 KB
Content
image-20220831171127-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +60.1 KB
Content
image-20220902104329-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +58.7 KB
Content
image-20220902111121-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +60.9 KB
Content
image-20220902111754-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +57.6 KB
Content
image-20220902111833-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +56.1 KB
Content