... ... @@ -178,14 +178,110 @@
178 178  
179 179  = Create communication with **Rockwell PLC** =
180 180  
181 +== **DF1 Advanced Protocol** ==
182 +
183 +MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05; PLC-5
184 +
185 +**1) V-Box Settings**
186 +
187 +|=Item|=Recommended |=Note
188 +|=Protocol|Allen Bradley DF1 Advanced|
189 +|=Connection|RS232|
190 +|=Baud rate|19200|
191 +|=Stop bits|1|
192 +|=Data bits|8|
193 +|=Parity|None|
194 +|=PLC Station No.|1|
195 +|=HMI Station No.|0|
196 +
197 +**2) Address List**
198 +
199 +|=**Type**|=**Device registers**|=**Format**|=**Range**|=Note
200 +|(% colspan="1" rowspan="7" %)Bit|I1|I1ddd.dd|0.0~~255.15|Only able to communicate with file number I1
201 +|O0|O0ddd.dd|0.0~~255.15|Only able to communicate with file number O0
202 +|S2|S2ddd.dd|0.0~~255.15|Only able to communicate with file number S2
203 +|B3|B3ddd.dd|0.0~~255.15|Only able to communicate with file number B3
204 +|BN|BNddddd.dd|0.0~~99255.15|(((
205 +Bit data file B0~~B99
206 +
207 +First two digits is for file number
208 +
209 +For example, BN13001.00 represents file number B13, address 001, the 0th bit.
210 +)))
211 +|N7|N7ddd.dd|0.0~~255.15|Only able to communicate with file number N7
212 +|NN|NNddddd.dd|0.0~~99255.15|(((
213 +Integer data file bit format N0~~N99
214 +
215 +First two digits is for file number
216 +
217 +For example, NN13001.00 represents file number N13, address 001, the 0th bit.
218 +)))
219 +|(% rowspan="11" %)Word|S2|S2ddd|0~~255|Only able to communicate with file number S2
220 +|T4S|T4Sddd|0~~255|Only able to communicate with file number T4 (Timer Preset Value)
221 +|T4P|T4Pddd|0~~255|Only able to communicate with file number T4 (Timer Accumulator Value)
222 +|TNS|TNSddddd|0~~99255|(((
223 +Timer Preset Value
224 +
225 +First two digits is for file number
226 +
227 +For example, TNS99255 represents file number T99, address 255.
228 +)))
229 +|TNP|TNPddddd|0~~99255|(((
230 +Timer Accumulator Value
231 +
232 +First two digits is for file number
233 +
234 +For example, TNP99255 represents file number T99, address 255.
235 +)))
236 +|C5S|C5Sddd|0~~255|Only able to communicate with file number C5 (Counter Preset Value)
237 +|C5P|C5Pddd|0~~255|Only able to communicate with file number C5 (Counter Accumulator Value)
238 +|CNS|CNSddddd|0~~99255|(((
239 +Counter Preset Value
240 +
241 +First two digits is for file number
242 +
243 +For example, CNS99255 represents file number C99, address 255.
244 +)))
245 +|CNP|CNPddddd|0~~99255|(((
246 +Counter Accumulator Value
247 +
248 +First two digits is for file number
249 +
250 +For example, CNP99255 represents file number C99, address 255.
251 +)))
252 +|N7|N7ddd|0~~255|Only able to communicate with file number N7
253 +|NN|NNddd|0~~99255|(((
254 +Integer data file
255 +
256 +First two digits is for file number
257 +
258 +For example, NN99255 represents file number N99, address 255.
259 +)))
260 +|(% colspan="1" rowspan="3" %)Double Word|F8|F8ddd|0~~255|(((
261 +Only able to communicate with file number N7
262 +)))
263 +|FN|FNddddd|0~~99255|(((
264 +Floating point data file
265 +
266 +First two digits is for file number
267 +
268 +For example, FN99255 represents file number F99, address 255.
269 +)))
270 +|LN|LNddddd|0~~99255|Long
271 +
272 +**3) Cable Wiring**
273 +
274 +(% style="text-align:center" %)
275 +[[image:ABRS232.gif]]
276 +
181 181  == (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** ==
182 182  
183 183  MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
184 184  
185 -**1)PLC Settings**
281 +**1)V-BOX setting**
186 186  
187 187  |**Item**|**Settings**|**Note**
188 -|Protocol|Allen-Bradlley DF1 Advanced|
284 +|Protocol|Allen-Bradley DF1 Advanced|
189 189  |Connection|RS232|
190 190  |Baud rate|19200|
191 191  |Data bit|8|
... ... @@ -420,7 +420,7 @@
420 420  The above are all the steps for establishing Ethernet communication between Wecon V-box with CompactLogix L1769 PLC.
421 421  
422 422  
423 -== **Allen-Bradley Ethernet DF1** ==
519 += **Allen-Bradley Ethernet DF1** =
424 424  
425 425  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]]
426 426  
... ... @@ -436,7 +436,7 @@
436 436  
437 437  Supported Series: Siemens S7-300 series PLC
438 438  
439 -**1)PLC Setting**
535 +**1)V-BOX setting**
440 440  
441 441  |**Items**|**Settings**|**Note**
442 442  |Protocol|Simens S7-300 Ethernet|
... ... @@ -498,7 +498,7 @@
498 498  
499 499  Supported Series: Siemens S7-400, S7-1200 and S7-1500
500 500  
501 -**1)PLC Setting**
597 +**1)V-BOX setting**
502 502  
503 503  |=**Items**|=**Settings**|=**Note**
504 504  |Protocol|Siemens S7-XXX|
... ... @@ -704,6 +704,101 @@
704 704  [[image:image-20220825100845-4.png]]
705 705  
706 706  
803 +== **FX3U Ethernet Protocol** ==
804 +
805 +Supported Modules: FX3U-ENET-ADP, FX3U-ENET-L
806 +
807 +**1)V-BOX Settings**
808 +
809 +|Items|Settings|Note
810 +|Protocol|Mitsubishi FX3U|
811 +|Connection|Ethernet|
812 +|Port No.|5009|Must be the same as the PLC setting
813 +|PLC station No.|0|
814 +
815 +**2)Address List**
816 +
817 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
818 +|(% colspan="1" rowspan="7" %)Bit|X|X|X OOO|0~~377|
819 +|Y|Y|Y OOO|0~~377|
820 +|M|M|M DDDD|0~~7679|
821 +|SM|SM|SM DDDD|8000~~8511|
822 +|S|S|S DDDD|0~~4095|
823 +|TS|TS|TS DDD|0~~511|
824 +|CS|CS|CS DDD|0~~255|
825 +|(% colspan="1" rowspan="9" %)Word|CN|CN|CN DDD|0~~199|
826 +|TN|TN|TN DDD|0~~511|
827 +|D|D|D DDDD|0~~7999|
828 +|SD|SD|SD DDDD|8000~~8511|
829 +|R|R|R DDDDD|0~~32767|
830 +
831 +**3)Ethernet Module Settings**
832 +
833 +FX3U-ENET-L module configuration
834 +Set up the FX3U-ENET-L Ethernet module settings as follows.
835 +Select the module location, which in this document is Module 0.
836 +
837 +[[image:image-20221116105850-1.png]]
838 +
839 +Select "Operational setting" to enter the following screen.
840 +
841 +The Ethernet module IP is set to 192.168.39.254 in this document, and other options are default.
842 +
843 +[[image:image-20221116105947-1.png]]
844 +
845 +Select "Open setting" to enter the setting interface, the settings are as follows.
846 +
847 +The third item "Protocol" selects TCP, and "Open system" selects MELSOFT connection, which allows the
848 +
849 +Mitsubishi programming software GX works2 to communicate with the FX3U via the Ethernet module.
850 +
851 +[[image:image-20221116110802-1.png]]
852 +
853 +Click on "transter setup" - "PC side I/F setting", see the following figure.
854 +
855 +After setting, the first download must use the programming cable, as shown in the figure; after that, can
856 +
857 +use the IP set in the "Ethernet board" to communicate directly with the network cable.
858 +
859 +[[image:image-20221116110832-2.png||height="423" width="708"]]
860 +
861 +Read and write data from the Ethernet module
862 +
863 +[[image:image-20221116110907-3.png]]
864 +
865 +Set "Transter setup" to COM communication, and read or write operation as shown below
866 +
867 +[[image:image-20221116110917-4.png]]
868 +
869 +**4)PLC Settings (GX Works 2)**
870 +
871 +Create a blank FX5U project
872 +
873 +Find Current Connection in the navigation
874 +
875 +[[image:image-20221116111427-1.png||height="421" width="705"]]
876 +
877 +Select Connection Channel List
878 +
879 +Select Ethernet board communication
880 +
881 +[[image:image-20221116111451-2.png||height="421" width="705"]]
882 +
883 +Select Ethernet Module
884 +Set the IP address of the PLC
885 +
886 +[[image:image-20221116111509-3.png||height="666" width="699"]]
887 +
888 +Read or write PLC data, in this document is read
889 +
890 +[[image:image-20221116111651-4.png||height="416" width="697"]]
891 +
892 +[[image:image-20221116111727-5.png||height="416" width="697"]]
893 +
894 +**4)Configure the communication protocol**
895 +
896 +[[image:image-20221119101946-2.png||height="395" width="695"]]
897 +
707 707  == **FX5U Serial Protocol** ==
708 708  
709 709  Mitsubishi FX5U series PLC
... ... @@ -858,11 +858,10 @@
858 858  
859 859  [[image:image-20220825112403-1.png||alt="图片-20220825112403-1.png"]]
860 860  
861 -**5)电缆布线**
1052 +**5)Cable Wiring**
862 862  
863 863  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
864 864  
865 -
866 866  == **L02 Serial Protocol** ==
867 867  
868 868  Mitsubishi L02 series CPU built-in serial port.
... ... @@ -996,6 +996,12 @@
996 996  
997 997  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
998 998  
1189 +== **Q12H Serial Protocol** ==
1190 +
1191 +This Demo shows V-BOX communicate with Q12H PLC by Q02H serial Protocol
1192 +
1193 +[[**Download link**>>https://ftp.we-con.com.cn/Download/WIKI/PI%20HMI/Demo/Communication/V-Box%20connect%20PLC%20Q12H.rar]]
1194 +
999 999  == **QJ71E71 Ethernet Protocol** ==
1000 1000  
1001 1001  Mitsubishi QJ71E71 Ethernet communication module;
... ... @@ -1044,10 +1044,13 @@
1044 1044  
1045 1045  * Click [Ethernet/CC IE/MELSECNET];
1046 1046  * Please select [Ethernet] as network type;
1047 -* Set station I/O number according to situation (For example, 0000 means that the module is connected to PLC CPU in first order);
1243 +* Set station I/O number according to situation (For example, 0020 means that the module is connected to PLC CPU in first order);
1048 1048  * Select [Online] as Mode;
1245 +* [[image:image-20221119171343-2.png||height="341" width="587"]]
1049 1049  * Click [Operation setting] to set IP;
1050 1050  * Select [Binary Code] as [Communication Data Code];
1248 +* [[image:image-20221119171436-3.png||height="354" width="588"]]
1249 +* Click [Open setting]
1051 1051  * Set protocol: TCP;
1052 1052  * Set [unpassive] in [Open system];
1053 1053  * Set [receive] in [Fixed buffer];
... ... @@ -1054,14 +1054,16 @@
1054 1054  * Set [procedure Exist] in [Fixed buffer communication];
1055 1055  * Disable [Pairing open];
1056 1056  * Set [No confirm] in [Existence confirmation];
1057 -* Host station port number: 1025;
1256 +* Host station port number: 5009;
1058 1058  * Save settings;
1258 +* [[image:image-20221119171611-4.png||height="354" width="588"]]
1059 1059  * Download project into PLC and restart it
1060 1060  
1061 1061  **4)Configure the communication protocol**
1062 1062  
1063 -[[image:image-20220825143728-1.png]]
1263 +[[image:image-20221119171832-5.png||height="354" width="625"]]
1064 1064  
1265 +
1065 1065  **5)Cable Wiring**
1066 1066  
1067 1067  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png"]]
... ... @@ -1070,12 +1070,105 @@
1070 1070  
1071 1071  == **DVP Ethernet Protocol** ==
1072 1072  
1073 -[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
1274 +Supoort Series: DELTA DVP20/32/40/60ES200RE/200TE or any DVP models with built-in Ethernet port, DELTA DVPEN01-SL module
1074 1074  
1276 +**1)V-BOX Settings**
1277 +
1278 +|=**Items**|=**Settings**|=**Note**
1279 +|Protocol|DELTA DVP MODBUS TCP|
1280 +|Connection|Ethernet|
1281 +|Port No.|502|
1282 +|Device No.|1|
1283 +|VBox Device No.|0|
1284 +
1285 +**2)Address List **
1286 +
1287 +|=**Type**|=(% style="width: 191px;" %)**Device registers**|=(% style="width: 217px;" %)**VBox registers**|=(% style="width: 168px;" %)**Format**|=(% style="width: 225px;" %)**Range**|=**Note**
1288 +|Bit|(% style="width:191px" %)X|(% style="width:217px" %)X|(% style="width:168px" %)X OOO|(% style="width:225px" %)0~~377|
1289 +|Bit|(% style="width:191px" %)Y|(% style="width:217px" %)Y|(% style="width:168px" %)Y OOO|(% style="width:225px" %)0~~377|
1290 +|Bit|(% style="width:191px" %)M0|(% style="width:217px" %)M0|(% style="width:168px" %)M0DDDD|(% style="width:225px" %)0~~1535|
1291 +|Bit|(% style="width:191px" %)M1|(% style="width:217px" %)M1|(% style="width:168px" %)M1DDDD|(% style="width:225px" %)1536~~4096|
1292 +|Bit|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDD|(% style="width:225px" %)0~~255|
1293 +|Bit|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDD|(% style="width:225px" %)0~~255|
1294 +|Bit|(% style="width:191px" %)S|(% style="width:217px" %)S|(% style="width:168px" %)SDDDD|(% style="width:225px" %)0~~1023|
1295 +|Word|(% style="width:191px" %)D0|(% style="width:217px" %)D0|(% style="width:168px" %)D0DDDD|(% style="width:225px" %)0~~4095|
1296 +|Word|(% style="width:191px" %)D1|(% style="width:217px" %)D1|(% style="width:168px" %)D1DDDD|(% style="width:225px" %)4096~~11999|
1297 +|Word|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDD|(% style="width:225px" %)0~~255|
1298 +|Word|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDD|(% style="width:225px" %)0~~199|
1299 +|Double Word|(% style="width:191px" %)HC|(% style="width:217px" %)HC|(% style="width:168px" %)HCDDD|(% style="width:225px" %)200~~255|
1300 +
1301 +**3) PLC Setting:**
1302 +
1303 +~1. Create new project in Delta WPL Soft, and click Setting to open the communication settings:
1304 +
1305 +(% style="text-align:center" %)
1306 +[[image:DVPEthernetWPLSoft2.png]]
1307 +
1308 +2. Set up the communication type and PLC IP:
1309 +
1310 +(% style="text-align:center" %)
1311 +[[image:DVPEthernetSetup.png]]
1312 +
1313 +(% class="wikigeneratedid" %)
1314 +3. Click OK and save the settings. Then click Communication on toolbar, then click Transfer Setup to open new window:
1315 +
1316 +(% style="text-align:center" %)
1317 +[[image:DVPEthernetTransfer.png]]
1318 +
1319 +(% class="wikigeneratedid" %)
1320 +4. Select Communication Mode as PC => PLC to download or select PC <=PLC to upload:
1321 +
1322 +(% style="text-align:center" %)
1323 +[[image:DVPEthernetPLCtoPC.png]]
1324 +
1325 +5. Click Auto-Search Ethernet Module to find the PLC on the same LAN network:
1326 +
1327 +(% style="text-align:center" %)
1328 +[[image:DVPEthernetAutoSearch.png]]
1329 +
1330 +**4) V-BOX Setting:**
1331 +
1332 +Set the same IP address according to the setting from WPL Soft:
1333 +
1334 +(% style="text-align:center" %)
1335 +[[image:DVPEthernetVNETPortocol.png]]
1336 +
1075 1075  == **DVP serial protocol** ==
1076 1076  
1077 -[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
1339 +Supoort Series: DELTA DVP EH/ES/SS/EX/EH2/SV/SA/SC/SX
1078 1078  
1341 +**1)V-BOX Settings**
1342 +
1343 +|=**Items**|=**Settings**|=**Note**
1344 +|Protocol|DELTA DVP PROTOCOL|
1345 +|Connection|RS232|
1346 +|Baud Rate|9600|
1347 +|Stop Bit|1|
1348 +|Data Bit|7|
1349 +|Parity|EVEN|
1350 +|Device No.|1|
1351 +
1352 +(% class="wikigeneratedid" %)
1353 +**2)Address List**
1354 +
1355 +|=**Type**|=(% style="width: 191px;" %)**Device registers**|=(% style="width: 217px;" %)**VBox registers**|=(% style="width: 168px;" %)**Format**|=(% style="width: 225px;" %)**Range**|=**Note**
1356 +|Bit|(% style="width:191px" %)X|(% style="width:217px" %)X|(% style="width:168px" %)X OOOOOO|(% style="width:225px" %)0~~303237|
1357 +|Bit|(% style="width:191px" %)Y|(% style="width:217px" %)Y|(% style="width:168px" %)Y OOOOOO|(% style="width:225px" %)0~~303237|
1358 +|Bit|(% style="width:191px" %)M|(% style="width:217px" %)M|(% style="width:168px" %)MDDDDD|(% style="width:225px" %)0~~99999|
1359 +|Bit|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDDDD|(% style="width:225px" %)0~~99999|
1360 +|Bit|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDDDD|(% style="width:225px" %)0~~99999|
1361 +|Bit|(% style="width:191px" %)S|(% style="width:217px" %)S|(% style="width:168px" %)SDDDDD|(% style="width:225px" %)0~~99999|
1362 +|Word|(% style="width:191px" %)D|(% style="width:217px" %)D|(% style="width:168px" %)D DDDDD|(% style="width:225px" %)0~~99999|
1363 +|Word|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDDDD|(% style="width:225px" %)0~~99999|
1364 +|Word|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDD|(% style="width:225px" %)0~~199|
1365 +|Double Word|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDDDD|(% style="width:225px" %)200~~99999|
1366 +
1367 +(% class="wikigeneratedid" %)
1368 +**3)Wiring Diagram**
1369 +
1370 +(% style="text-align:center" %)
1371 +[[image:Delta DVP PROTOCOLSerial232.png]]
1372 +
1079 1079  == **AS Ethernet Protocol** ==
1080 1080  
1081 1081  **1)V-BOX Settings**
... ... @@ -1109,7 +1109,6 @@
1109 1109  
1110 1110  **3)Configure the communication protocol**
1111 1111  
1112 -
1113 1113  [[image:image-20220831160010-4.png]]
1114 1114  
1115 1115  **4)Cable Wiring**
... ... @@ -1242,7 +1242,7 @@
1242 1242  
1243 1243  **1)V-BOX Settings**
1244 1244  
1245 -Supported Series: Delta Xinjie XD/XE Series PLC
1538 +Supported Series: Xinjie XD/XE Series PLC
1246 1246  
1247 1247  |**Item**|**Settings**|**Note**
1248 1248  |Protocol|XINJE XD/XC MODBUS|
... ... @@ -1312,15 +1312,49 @@
1312 1312  
1313 1313  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830160232-3.png?rev=1.1||alt="image-20220830160232-3.png"]]
1314 1314  
1315 -= Create communication with Inovance** PLC**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=37]] =
1608 += Create communication with **Schneider PLC** =
1316 1316  
1317 -== **H3U serial protocol**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=38]] ==
1610 +== **Schneider MODBUS RTU** ==
1318 1318  
1319 -**1)HMI Settings**
1612 +**1)V-BOX Setting**
1320 1320  
1614 +|=**Parameters**|=**Recommended**|=**Notes**
1615 +|**Protocol**|(% colspan="1" %)Schneider MODBUS RTU|
1616 +|**Connection**|RS485|
1617 +|**Baud rate**|19200|
1618 +|**Data bit**|8|
1619 +|**Parity**|Even|
1620 +|**Stop bit**|1|
1621 +|**PLC station No.**|1|
1622 +
1623 +**2)Address List**
1624 +
1625 +|=**Bit/Word**|=**Device type**|=**Format**|=**Range**|=**Memo**
1626 +|B|IX|DDDDDo|0 ~~ 655357|Input bit (read only)
1627 +|B|QX|DDDDDo|0 ~~ 655357|Write multiple coils
1628 +|B|MX|DDDDDDo|0 ~~ 9999997|Output register bit (octal)
1629 +|W|MW|DDDDDD|0 ~~ 999999|Output register
1630 +|DW|MD|DDDDDD|0 ~~ 999999|Output register
1631 +
1632 +**3)Configure the communication protocol**
1633 +
1634 +[[image:image-20220902104329-1.png]]
1635 +
1636 +**4)Cable Wiring**
1637 +
1638 +**RS-485 2W **(RJ45 Connector): The following is the view from the soldering point of a connector.
1639 +
1640 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220817154212-1.jpeg?width=554&height=315&rev=1.1||alt="image-20220817154212-1.jpeg" height="315" width="554"]]
1641 +
1642 += Create communication with Inovance** PLC** =
1643 +
1644 +== **H3U serial protocol** ==
1645 +
1646 +**1)V-BOX Settings**
1647 +
1321 1321  |**Item**|**Settings**|**Note**
1322 1322  |Protocol|INOVANCE H3U PLC|
1323 -|Connection|RS22|
1650 +|Connection|RS422|
1324 1324  |Baud rate|9600|
1325 1325  |Data bit|7|
1326 1326  |Parity|EVEN|
... ... @@ -1350,25 +1350,25 @@
1350 1350  
1351 1351  **3)Configure the communication protocol**
1352 1352  
1353 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830170114-4.png?rev=1.1||alt="image-20220830170114-4.png"]]
1680 +[[image:image-20220831164626-1.png]]
1354 1354  
1355 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830170017-3.png?rev=1.1||alt="image-20220830170017-3.png"]]
1356 1356  
1683 +
1357 1357  **4)Cable Wiring**
1358 1358  
1359 1359  Figure
1360 1360  
1361 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830165930-1.png?rev=1.1||alt="image-20220830165930-1.png"]]
1688 +[[image:image-20220831164646-2.png]][[image:image-20220831164700-3.png]]
1362 1362  
1363 1363  Pin Definition Diagram
1364 1364  
1365 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830165947-2.png?rev=1.1||alt="image-20220830165947-2.png"]]
1692 +[[image:image-20220831164731-4.png]]
1366 1366  
1367 -= Create communication with Panasonic** PLC**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=39]] =
1694 += Create communication with Panasonic** PLC** =
1368 1368  
1369 -== **FP serial protocol**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=40]] ==
1696 +== **FP serial protocol** ==
1370 1370  
1371 -**1)HMI Settings**
1698 +**1)V-BOX Settings**
1372 1372  
1373 1373  |**Item**|**Settings**|**Note**
1374 1374  |Protocol|Panasonic FP MFWTOCOL|
... ... @@ -1400,25 +1400,25 @@
1400 1400  
1401 1401  **3)Configure the communication protocol**
1402 1402  
1403 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830171050-1.png?rev=1.1||alt="image-20220830171050-1.png"]]
1730 +[[image:image-20220831165238-4.png]]
1404 1404  
1405 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830171126-2.png?rev=1.1||alt="image-20220830171126-2.png"]]
1406 1406  
1733 +
1407 1407  **4)Cable Wiring**
1408 1408  
1409 1409  Figure
1410 1410  
1411 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830171328-4.png?rev=1.1||alt="image-20220830171328-4.png"]]
1738 +[[image:image-20220831165031-3.png]][[image:image-20220831165017-2.png]]
1412 1412  
1413 1413  Pin Definition Diagram
1414 1414  
1415 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830171146-3.png?rev=1.1||alt="image-20220830171146-3.png"]]
1742 +[[image:image-20220831165008-1.png]]
1416 1416  
1417 -= Create communication with LS** PLC**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=41]] =
1744 += Create communication with LS** PLC** =
1418 1418  
1419 -== **XBC serial protocol**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=42]] ==
1746 +== **XBC serial protocol** ==
1420 1420  
1421 -**1)HMI Settings**
1748 +**1)V-BOX Settings**
1422 1422  
1423 1423  |**Item**|**Settings**|**Note**
1424 1424  |Protocol|LS XBC CNet|
... ... @@ -1456,25 +1456,23 @@
1456 1456  
1457 1457  **3)Configure the communication protocol**
1458 1458  
1459 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830174853-3.png?rev=1.1||alt="image-20220830174853-3.png"]]
1786 +[[image:image-20220831170147-1.png]]
1460 1460  
1461 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830174733-2.png?rev=1.1||alt="image-20220830174733-2.png"]]
1462 -
1463 1463  **4)Cable Wiring**
1464 1464  
1465 1465  Figure
1466 1466  
1467 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830174659-1.png?rev=1.1||alt="image-20220830174659-1.png"]]
1792 +[[image:image-20220831170306-4.png]][[image:image-20220831170254-3.png]]
1468 1468  
1469 1469  Pin Definition Diagram
1470 1470  
1471 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830173402-8.png?rev=1.1||alt="image-20220830173402-8.png"]]
1796 +[[image:image-20220831170215-2.png]]
1472 1472  
1473 -== **XGK FEnet Ethernet protocol**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=43]] ==
1798 +== **XGK FEnet Ethernet protocol** ==
1474 1474  
1475 1475  Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module
1476 1476  
1477 -**HMI Settings**
1802 +**1)V-BOX Settings**
1478 1478  
1479 1479  |**Items**|**Settings**|**Note**
1480 1480  |Protocol|LG XGK FEnet(Ethernet)|
... ... @@ -1481,7 +1481,7 @@
1481 1481  |Connection|Ethernet|
1482 1482  |Port No.|2004|
1483 1483  
1484 -**Address List**
1809 +**2)Address List**
1485 1485  
1486 1486  |**Type**|**Register**|**Range**|**Format**|**Note**
1487 1487  |(% rowspan="14" %)Word|P|0~~2047|P d|
... ... @@ -1505,186 +1505,18 @@
1505 1505  * The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC;
1506 1506  * All bit registers are in the form of bits in word, and the range is the same as the word register;
1507 1507  
1508 -**Communication settings in HMI**
1833 +**3)Communication Settings**
1509 1509  
1510 -Enable HMI Ethernet in [Project Settings];
1835 +[[image:image-20220831171127-1.png]]
1511 1511  
1512 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_43b671f18153910d.png?width=405&height=107&rev=1.1||alt="12.PLC Protocol_html_43b671f18153910d.png" height="107" width="405"]]
1837 +**4)Cable Wiring**
1513 1513  
1514 -Set PLC IP in [Device IP] settings;
1515 -
1516 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_a2a19b5003ad4090.png?width=554&height=189&rev=1.1||alt="12.PLC Protocol_html_a2a19b5003ad4090.png" height="189" width="554"]]
1517 -
1518 -**Cable Wiring**
1519 -
1520 1520  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1521 1521  
1522 -= Create communication with **SHIMADEN PLC**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=44]] =
1841 += Create communication with **Modbus ** =
1523 1523  
1524 -== **FP23 series protocol**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=45]] ==
1843 +== **MODBUS RTU Slave (All function)** ==
1525 1525  
1526 -Supported series: SHIMADEN FP23 series
1527 -
1528 -**HMI Setting**
1529 -
1530 -|**Items**|**Settings**|**Note**
1531 -|Protocol|SHIMADEN FP23 series|
1532 -|Connection|RS485 (9600, 1, 7, EVEN)|
1533 -|Port No.|None|
1534 -|PLC station No.|0|
1535 -
1536 -**Address List**
1537 -
1538 -|**Device address**|**HMI register**|**Address range**|**Type**
1539 -|0040-0043(HEX)|FP040|100064-200067|Read only
1540 -|0100-010B(HEX)|FP100|100256-200267|Read only
1541 -|0110-0142(HEX)|FP110|100272-200322|Read only
1542 -|0182-0252(HEX)|FP182|100386-200594|Write only
1543 -|0280-0281(HEX)|FP280|100640-200641|Read only
1544 -|0300-030B(HEX)|FP300|100768-200779|Read and write
1545 -|0380-039F(HEX)|FP380|100896-200927|Read and write
1546 -|0400-04D7(HEX)|FP400|101024-201239|Read and write
1547 -|0500-05B0(HEX)|FP500|101280-201456|Read and write
1548 -|0600-0670(HEX)|FP600|101536-201814|Read and write
1549 -|0720-0738(HEX)|FP720|101824-201848|Read and write
1550 -|0800-083F(HEX)|FP800|102048-202111|Read and write
1551 -|0900-0952(HEX)|FP900|102304-202386|Read and write
1552 -| |Ctrl|0-2|
1553 -
1554 -**✎Note:**
1555 -
1556 -* The upper 2 bits of the address of the HMI register are taken as the sub address, and the real address is the last four bits (for example, if the address is 100256, then 10 is the sub address as 1, and 0256 is the real address);
1557 -* The address range in the table is only divided by the start and end addresses, and some of the addresses in the range have no corresponding address in FP23;
1558 -* The Ctrl register is used to store the control group number and BCC check mode.
1559 -
1560 -**Ctrl Register Description**
1561 -
1562 -* The Ctrl register is a special register that does not communicate with the temperature controller. User needs to assign value in the screen according to the settings as in the temperature controller.
1563 -* Ctrl0 indicates the setting of the control character, the valid values are 1, 2, 3 respectively, and the corresponding control group is: STX_ETX_CR , STX_ETX_CR LF and @_:_CR .
1564 -* Ctrl1 indicates the BCC block check mode. The valid value range is 1-4. The corresponding check mode is: 1.ADD, 2.ADD_two's cmp, 3.XOR, 4.None;
1565 -* Ctrl3 reserved
1566 -
1567 -**✎Note:**
1568 -
1569 -After reloading the HMI project or restarting the HMI, HMI will reset the value of ctrl0 and ctrl1 as 1, so user need to set these two values to make it the same as it in the temperature controller, then communication will be normal.
1570 -
1571 -**Cable Wiring**
1572 -
1573 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5e9a81a14106da9e.png?width=392&height=223&rev=1.1||alt="12.PLC Protocol_html_5e9a81a14106da9e.png" height="223" width="392"]]
1574 -
1575 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_1897d92be6948d58.png?width=393&height=223&rev=1.1||alt="12.PLC Protocol_html_1897d92be6948d58.png" height="223" width="393"]]
1576 -
1577 -**✎Note:** COM3 only available in PI8000/PI9000 series.
1578 -
1579 -== **SR90 protocol**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=46]] ==
1580 -
1581 -Supported series: SHIMADEN SR90 series
1582 -
1583 -**HMI Setting**
1584 -
1585 -|**Items**|**Settings**|**Note**
1586 -|Protocol|SHIMADEN SR90 protocol|
1587 -|Connection|RS485 (1200, 1, 7, EVEN)|
1588 -|Port No.|None|
1589 -|PLC station No.|0|
1590 -
1591 -**Address List**
1592 -
1593 -|**Device address**|**HMI register**|**Address range**|**Type**
1594 -|0040-0043 (HEX)|SR040|100064-100067|Read only
1595 -|0100-010A(HEX)|SR0100|100256-100266|Read only
1596 -|0182-018C(HEX)|SR0182|100386-100396|Write only
1597 -|0300-04FE(HEX)|SR0300|100768-101278|Write/read
1598 -|0500-050B(HEX)|SR0500|101280-101291|Write/read
1599 -|0590-0611(HEX)|SR0590|101424-101553|Write/read
1600 -|0701-0709(HEX)|SR0701|101793-101801|Write/read
1601 -| |Ctrl|0-2|~-~-
1602 -
1603 -**✎Note:**
1604 -
1605 -* The upper 2 bits of the address of HMIs are taken as the sub address, and the real address is the last four bits (for example, if the address is 100256, then 10 is the sub address as 1, and 0256 is the real address);
1606 -* The address range in the table is only divided by the start and end addresses, and some of the addresses in the range have no corresponding address in SR90;
1607 -* The Ctrl register is used to store the control group number and BCC check mode. See how to use it below;
1608 -
1609 -**Ctrl Register Description**
1610 -
1611 -* The Ctrl register is a special register that does not communicate with the temperature controller. User needs to assign value in the screen according to the settings as in the temperature controller.
1612 -* Ctrl0 indicates the setting of the control character, the valid values are 1, 2, 3 respectively, and the corresponding control group is: STX_ETX_CR , STX_ETX_CR LF and @_:_CR .
1613 -* Ctrl1 indicates the BCC block check mode. The valid value range is 1-4. The corresponding check mode is: 1.ADD, 2.ADD_two's cmp, 3.XOR, 4.None;
1614 -* Ctrl3 reserved
1615 -
1616 -**✎Note:**
1617 -
1618 -After reloading the HMI project or restarting the HMI, HMI will reset the value of ctrl0 and ctrl1 as 1, so user need to set these two values to make it the same as it in the temperature controller, then communication will be normal.
1619 -
1620 -**Cable Wiring**
1621 -
1622 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5e9a81a14106da9e.png?width=392&height=223&rev=1.1||alt="12.PLC Protocol_html_5e9a81a14106da9e.png" height="223" width="392"]]
1623 -
1624 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_1897d92be6948d58.png?width=393&height=223&rev=1.1||alt="12.PLC Protocol_html_1897d92be6948d58.png" height="223" width="393"]]
1625 -
1626 -**✎Note:** COM3 only available in PI8000/PI9000 series.
1627 -
1628 -== **MR13 series(standard protocol)**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=47]] ==
1629 -
1630 -Supported series: SHIMADEN MR13 series
1631 -
1632 -**HMI Setting**
1633 -
1634 -|**Items**|**Settings**|**Note**
1635 -|Protocol|SHIMADEN standard protocol|
1636 -|Connection|RS485 (1200, 1, 7, EVEN)|
1637 -|Port No.|None|
1638 -|PLC station No.|0|
1639 -
1640 -**Address List**
1641 -
1642 -|**Device address**|**HMI register**|**Address range**|**Type**
1643 -|0100-010B(HEX)|MR100|100256-300267|Read only
1644 -|0111-0126(HEX)|MR111|100273-300294|Read only
1645 -|0184-0192(HEX)|MR184|100388-300402|Write only
1646 -|0280-0282(HEX)|MR280|100640-300642|Read only
1647 -|0300-030B(HEX)|MR300|100768-300779|Read/write
1648 -|0314-0317(HEX)|MR314|100788-300791|Read/write
1649 -|031A(HEX)|MR31A|100794-300794|Read/write
1650 -|0320-0321(HEX)|MR320|100800-300801|Read/write
1651 -|0400-0504(HEX)|MR400|101024-301284|Read/write
1652 -|0506(HEX)|MR506|101286-301286|Read/write
1653 -|0510-0514(HEX)|MR510|101296-301300|Read/write
1654 -|0516-0524(HEX)|MR516|101302-301316|Read/write
1655 -|0526(HEX)|MR526|101318-301318|Read/write
1656 -|0580-08C3(HEX)|MR580|101408-302243|Read/write
1657 -|~-~-|Ctrl|0-2|~-~-
1658 -
1659 -**✎Note:**
1660 -
1661 -* The upper 2 bits of the address of the HMI register are taken as the sub address, and the real address is the last four bits (for example, if the address is 100256, then 10 is the sub address as 1, and 0256 is the real address);
1662 -* The address range in the table is only divided by the start and end addresses, and some of the addresses in the range have no corresponding address in MR13;
1663 -* The Ctrl register is used to store the control group number and BCC check mode.
1664 -
1665 -**Ctrl Register Description**
1666 -
1667 -* The Ctrl register is a special register that does not communicate with the temperature controller. User needs to assign value in the screen according to the settings as in the temperature controller.
1668 -* Ctrl0 indicates the setting of the control character, the valid values are 1, 2, 3 respectively, and the corresponding control group is: STX_ETX_CR, STX_ETX_CR LF and @_:_CR .
1669 -* Ctrl1 indicates the BCC block check mode. The valid value range is 1-4. The corresponding check mode is: 1.ADD, 2.ADD_two's cmp, 3.XOR, 4.None;
1670 -* Ctrl3 reserved
1671 -
1672 -**✎Note:**
1673 -
1674 -After reloading project or restarting the HMI, HMI will reset the value of ctrl0 and ctrl1 as 1, so user need to set these two values to make it the same as it in the temperature controller, then communication will be normal.
1675 -
1676 -**Cable Wiring**
1677 -
1678 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5e9a81a14106da9e.png?width=392&height=223&rev=1.1||alt="12.PLC Protocol_html_5e9a81a14106da9e.png" height="223" width="392"]]
1679 -
1680 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_1897d92be6948d58.png?width=393&height=223&rev=1.1||alt="12.PLC Protocol_html_1897d92be6948d58.png" height="223" width="393"]]
1681 -
1682 -**✎Note:** COM3 only available in PI8000/PI9000 series.
1683 -
1684 -= Create communication with **Modbus RTU** =
1685 -
1686 -== **V-BOX as Slave** ==
1687 -
1688 1688  Select the protocol "Modbus RTU Slave (All Fuction)",
1689 1689  
1690 1690  Then set baud rate, port, stop bits, data bits, parity.
... ... @@ -1692,7 +1692,7 @@
1692 1692  (% style="text-align:center" %)
1693 1693  [[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]]
1694 1694  
1695 -== **V-BOX as Master** ==
1852 +== **MODBUS RTU Master** ==
1696 1696  
1697 1697  Select the protocol "Modbus RTU Master",
1698 1698  
... ... @@ -1704,8 +1704,8 @@
1704 1704  **address list**
1705 1705  
1706 1706  (% class="table-bordered" %)
1707 -|**type**|**register**|**Function code and description**
1708 -|(% rowspan="11" %)|(% rowspan="3" %)3|04 (Read Input Registers: Read the current binary value in one or more input registers)
1864 +|=(% scope="row" %)**Type**|=**Data Type**|=**Function code and description**
1865 +|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (Read Input Registers: Read the current binary value in one or more input registers)
1709 1709  |06 (write single register: write a binary value to a holding register)
1710 1710  |10 (write values to multiple addresses )
1711 1711  |(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers)
... ... @@ -1728,6 +1728,61 @@
1728 1728  |(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils)
1729 1729  |0F (Write multiple bits)
1730 1730  
1888 +== **MODBUS TCP Slave (All function)** ==
1889 +
1890 +Supported series: MODBUS TCP controller
1891 +
1892 +V-B0X works as MODBUS TCP MASTER connecting with TCP SLAVE
1893 +
1894 +**1)V-BOX Setting**
1895 +
1896 +|**Items**|**Settings**|**Note**
1897 +|Protocol|MODBUS TCP Slave (All function)|
1898 +|Connection|Ethernet|
1899 +|Port No.|502|
1900 +|PLC station No.|1
1901 +
1902 +**2)Address List**
1903 +
1904 +|=**Type**|=**Data Type**|=**Function code & Description**
1905 +|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers)
1906 +|06 (write single register: write a binary value to a holding register)
1907 +|10 (write values to multiple addresses )
1908 +|(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers)
1909 +|06 (write single register: write a binary value to a holding register)
1910 +|10 (write values to multiple addresses )
1911 +|(% rowspan="3" %)W6|03 (read holding register: read current binary value in one or more holding registers)
1912 +|06 (write single register: write a binary value to a holding register)
1913 +|10 (write values to multiple addresses )
1914 +|(% rowspan="2" %)W16|03 (read holding register: read current binary value in one or more holding registers)
1915 +|10 (write values to multiple addresses )
1916 +|(% rowspan="11" %)Bit|(% rowspan="3" %)0|01 (Read coil state)
1917 +|05 (Force a single coil to force the on/off state of a logic coil)
1918 +|0F (Write multiple bits, ie write continuously)
1919 +|(% rowspan="3" %)1|02 (Read the input state)
1920 +|05 (Force a single coil to force the on/off state of a logic coil)
1921 +|0F (Write multiple bits)
1922 +|(% rowspan="3" %)W5|01 (Read coil state to obtain the current state of a set of logic coils)
1923 +|05 (Force a single coil to force the on/off state of a logic coil)
1924 +|0F (Write multiple bits)
1925 +|(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils)
1926 +|0F (Write multiple bits)
1927 +
1928 +**3)Communication Settings**
1929 +
1930 +Configure V-BOX Ethernet IP in Networking Settings
1931 +
1932 +[[image:image-20220902111833-3.png]]
1933 +
1934 +
1935 +Configure PLC Ethernet IP in Communication;
1936 +
1937 +[[image:image-20220902111121-1.png]]
1938 +
1939 +**4)Cable Wiring**
1940 +
1941 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1942 +
1731 1731  == **communicate with VB inverter** ==
1732 1732  
1733 1733  [[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20VB%20inverter.zip]]
AB.gif
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +7.3 KB
Content
ABRS232.gif
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +7.3 KB
Content
DVPEthernetAutoSearch.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +43.6 KB
Content
DVPEthernetPLCtoPC.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +8.9 KB
Content
DVPEthernetSetup.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +19.9 KB
Content
DVPEthernetTransfer.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +59.9 KB
Content
DVPEthernetVNETPortocol.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +21.4 KB
Content
DVPEthernetWPLSoft.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +97.5 KB
Content
DVPEthernetWPLSoft2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +45.2 KB
Content
Delta DVP PROTOCOLSerial232.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +10.7 KB
Content
image-20220831164626-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +56.1 KB
Content
image-20220831164646-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +28.4 KB
Content
image-20220831164700-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +66.6 KB
Content
image-20220831164731-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +12.3 KB
Content
image-20220831165008-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +13.3 KB
Content
image-20220831165017-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +36.2 KB
Content
image-20220831165031-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +28.3 KB
Content
image-20220831165238-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +57.4 KB
Content
image-20220831170147-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +57.1 KB
Content
image-20220831170215-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +14.3 KB
Content
image-20220831170254-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +43.5 KB
Content
image-20220831170306-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +28.5 KB
Content
image-20220831171127-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +60.1 KB
Content
image-20220902104329-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +58.7 KB
Content
image-20220902111121-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +60.9 KB
Content
image-20220902111754-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +57.6 KB
Content
image-20220902111833-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +56.1 KB
Content
image-20221116105850-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +18.9 KB
Content
image-20221116105947-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +18.7 KB
Content
image-20221116110802-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +16.4 KB
Content
image-20221116110832-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +42.2 KB
Content
image-20221116110907-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +17.8 KB
Content
image-20221116110917-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +23.2 KB
Content
image-20221116111427-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +63.4 KB
Content
image-20221116111451-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +225.5 KB
Content
image-20221116111509-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +34.1 KB
Content
image-20221116111651-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +74.3 KB
Content
image-20221116111727-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +106.2 KB
Content
image-20221116114106-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +99.5 KB
Content
image-20221119101759-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +62.1 KB
Content
image-20221119101946-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +68.7 KB
Content
image-20221119171318-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +90.3 KB
Content
image-20221119171343-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +90.3 KB
Content
image-20221119171436-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +43.4 KB
Content
image-20221119171611-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +23.1 KB
Content
image-20221119171832-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +69.6 KB
Content