Changes for page 1 Communication

Last modified by Hunter on 2024/07/01 10:54

From version 15.1
edited by Ben
on 2022/07/14 14:50
Change comment: There is no comment for this version
To version 14.1
edited by Ben
on 2022/07/14 14:39
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -58,41 +58,35 @@
58 58  (% style="text-align:center" %)
59 59  [[image:1624348978863-771.png||queryString="width=812&height=494" height="487" width="800" class="img-thumbnail"]]
60 60  
61 -(% class="wikigeneratedid" %)
62 -== ==
63 -
64 64  == **2 Communication with Allen-Bradley CompactLogix L1769** ==
65 65  
66 66  (((
67 67  This example introduces the establishment of Ethernet communication between Wecon V-box and Allen-Bradley L1769. It is introduced through three parts: PLC software configuration, V-box software configuration, and hardware wiring.
68 -
69 -
70 70  )))
71 71  
72 72  (((
73 -(% class="wikigeneratedid" id="HSoftwareconfigurationofPLC" %)
74 -(((
75 -**Software configuration of PLC**
68 +
76 76  )))
77 77  
78 -(% class="wikigeneratedid" id="HPLCprogrammingsoftware" %)
79 79  (((
80 -**1)PLC programming software**
81 -)))
72 +== **Software configuration of PLC** ==
82 82  
83 -[[image:image-20220714113935-3.png||height="324" width="270"]]
74 +=== **PLC programming software** ===
84 84  
85 -(% class="wikigeneratedid" id="HNewPLCproject" %)
76 + [[image:image-20220714113935-3.png]]
77 +
78 +=== **New PLC project** ===
79 +
86 86  (((
87 -**2)New PLC project**
81 +Click New Project and select the PLC model.
88 88  )))
89 89  
90 90  (((
91 -Click New Project and select the PLC model.
85 + [[image:image-20220714114247-4.png]]
92 92  )))
93 93  
94 94  (((
95 -[[image:image-20220714114247-4.png||height="298" width="552"]] [[image:image-20220714114257-5.png||height="445" width="551"]]
89 + [[image:image-20220714114257-5.png]]
96 96  )))
97 97  
98 98  (((
... ... @@ -100,37 +100,26 @@
100 100  )))
101 101  
102 102  (((
103 -(% class="wikigeneratedid" id="HSetEthernetparameters" %)
104 -(((
105 -**3)Set Ethernet parameters**
106 -)))
97 +=== **Set Ethernet parameters** ===
107 107  
108 108  (((
109 -(((
110 110  Follow the steps below to configure Ethernet parameters
111 111  )))
112 -)))
113 113  
114 114  (((
115 -(((
116 116  PLC IP address:192.168.40.101
117 117  )))
118 -)))
119 119  
120 120  (((
121 -(((
122 122  default gateway:192.168.40.1
123 123  )))
124 -)))
125 125  
126 126  (((
127 -(((
128 128  subnet mask:255.255.255.0
129 129  )))
130 -)))
131 131  
132 132  (((
133 -[[image:image-20220714115012-6.png]]
116 + [[image:image-20220714115012-6.png]]
134 134  )))
135 135  
136 136  (((
... ... @@ -138,48 +138,36 @@
138 138  )))
139 139  
140 140  (((
141 -(% class="wikigeneratedid" id="HV-boxsoftwareconfiguration" %)
142 -(((
143 -**V-box software configuration**
144 -)))
124 +== **V-box software configuration** ==
145 145  
146 -(% class="wikigeneratedid" id="HV-boxprogrammingsoftware" %)
147 -(((
148 -**1)V-box programming software**
149 -)))
126 +=== **V-box programming software** ===
150 150  
151 -(% class="wikigeneratedid" %)
152 -(((
153 - [[image:image-20220714115214-7.png||height="276" width="456"]]
154 -)))
128 + [[image:image-20220714115214-7.png]]
155 155  
156 -(% class="wikigeneratedid" id="HConfiguredevicenetwork" %)
157 -(((
158 -**2)Configure device network**
159 -)))
160 160  
131 +=== **Configure device network** ===
132 +
161 161  (((
162 -(((
163 163  Click the Configuration Download button[[image:image-20220714115308-8.png||height="22" width="15"]], It is used to configure the device network, update the device time, obtain the device machine code, check the device network, etc.
164 164  )))
165 -)))
166 166  
167 167  (((
168 -(((
169 -In the example below, the IP address of V-Box is configured as 192.168.40.66, and the networking method is 4G connection [[image:image-20220714115440-9.png||height="425" width="791"]]
138 +In the example below, the IP address of V-Box is configured as 192.168.40.66, and the networking method is 4G connection.
170 170  )))
140 +
141 + [[image:image-20220714115440-9.png||height="425" width="791"]]
171 171  )))
172 172  )))
144 +
145 +== **V-net add device** ==
173 173  )))
174 174  
175 -(% class="wikigeneratedid" id="HV-netadddevice" %)
176 176  (((
177 -**3)V-net add device**
149 +Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device. 
178 178  )))
179 -)))
180 180  
181 181  (((
182 -Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device.   [[image:image-20220714115640-10.png||height="430" width="797"]]
153 + [[image:image-20220714115640-10.png||height="430" width="797"]]
183 183  )))
184 184  
185 185  (((
... ... @@ -187,14 +187,14 @@
187 187  )))
188 188  
189 189  (((
190 -(% class="wikigeneratedid" id="HSetcommunicationportparameters" %)
191 -(((
192 -**4)Set communication port parameters**
193 -)))
161 +=== **Set communication port parameters** ===
194 194  
195 -In the device list on the left, find the Vbox that communicates with the L1769, click it and select configuration,communication port configuration in the main interface to add a communication protocol. [[image:image-20220714115848-11.png||height="432" width="802"]]
163 +In the device list on the left, find the Vbox that communicates with the L1769, click it and select configuration,communication port configuration in the main interface to add a communication protocol.
164 +
165 + [[image:image-20220714115848-11.png||height="432" width="802"]]
196 196  )))
197 197  
168 +
198 198  The communication port is selected as Ethernet, the device type is selected as Allen-Bradley, the protocol is Allen-BradleyMicro850_FreeTag EthemetIP, and the IP is the internal IP address of the L1769 PLC. The port number is 44818.
199 199  
200 200  [[image:image-20220714143820-1.png]]