Changes for page 1 Communication

Last modified by Hunter on 2024/07/01 10:54

From version 15.1
edited by Ben
on 2022/07/14 14:50
Change comment: There is no comment for this version
To version 71.1
edited by Ben
on 2022/08/24 14:27
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,73 +1,244 @@
1 -= **1 General communication with PLC** =
1 += (% style="color:inherit; font-family:inherit" %)**WECON PLC**(%%) =
2 2  
3 -== **Modbus RTU** ==
3 +== **LX3V Serial Protocol** ==
4 4  
5 -=== **V-BOX as master** ===
5 +Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM
6 6  
7 -Select the protocol “(% class="mark" %)Modbus RTU Slave(All Fuction)”,
7 +**HMI Settings**
8 8  
9 -(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity
9 +|**Item**|**Settings**|**Note**
10 +|Protocol|WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM|
11 +|Connection|RS422/RS485|
12 +|Baud rate|9600|
13 +|Data bit|7|
14 +|Parity|EVEN|
15 +|Stop bit|1|
16 +|PLC station No.|1|
10 10  
11 -(% style="text-align:center" %)
12 -[[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]]
18 +**Address List**
13 13  
14 -=== **V-BOX as slave** ===
20 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
21 +|(% rowspan="6" %)Bit|X|X|Xo|0~~303237|
22 +|Y|Y|Y o|0~~303237|
23 +|M|M|M d|0~~99999|
24 +|T|T|T d|0~~99999|
25 +|C|C|C d|0~~99999|
26 +|S|S|S d|0~~99999|
27 +|(% rowspan="8" %)Word|X|X|Xo|0~~303237|
28 +|Y|Y|Y o|0~~303237|
29 +|M|M|M d|0~~99999|
30 +|T|T|T d|0~~99999|
31 +|C|C|C d|0~~199|
32 +|D|D|D d|0~~7999|
33 +|S|S|S d|0~~99999|
34 +|SD|SD|SD d|8000~~9999|
15 15  
16 -Select the protocol “(% class="mark" %)**Modbus RTU Master**,
36 +**Cable Wiring**
17 17  
18 -(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity
38 +* **RS422**
19 19  
20 -(% style="text-align:center" %)
21 -[[image:1624348709622-711.png||queryString="width=809&height=493" height="488" width="800" class="img-thumbnail"]]
40 + [[image:image-20220824120614-5.png]]
22 22  
23 -**Address List**
42 +* **RS485**
24 24  
25 -(% class="table-bordered" %)
26 -|**Type**|**Register**|**Function code & Description**
27 -|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers)
28 -|06 (write single register: write a binary value to a holding register)
29 -|10 (write values to multiple addresses )
30 -|(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers)
31 -|06 (write single register: write a binary value to a holding register)
32 -|10 (write values to multiple addresses )
33 -|(% rowspan="3" %)W6|03 (read holding register: read current binary value in one or more holding registers)
34 -|06 (write single register: write a binary value to a holding register)
35 -|10 (write values to multiple addresses )
36 -|(% rowspan="2" %)W16|03 (read holding register: read current binary value in one or more holding registers)
37 -|10 (write values to multiple addresses )
38 -|(% rowspan="11" %)Bit|(% rowspan="3" %)0|01 (Read coil state)
39 -|05 (Force a single coil to force the on/off state of a logic coil)
40 -|0F (Write multiple bits, ie write continuously)
41 -|(% rowspan="3" %)1|02 (Read the input state)
42 -|05 (Force a single coil to force the on/off state of a logic coil)
43 -|0F (Write multiple bits)
44 -|(% rowspan="3" %)W5|01 (Read coil state to obtain the current state of a set of logic coils)
45 -|05 (Force a single coil to force the on/off state of a logic coil)
46 -|0F (Write multiple bits)
47 -|(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils)
48 -|0F (Write multiple bits)
44 + [[image:image-20220824120524-3.png]]
49 49  
50 -== **WECON LX3V PLC** ==
46 +== **LX5V Serial Protocol** ==
51 51  
52 -Select the protocol (% class="mark" %)"WECON LX3V"
48 +This example introduces the establishment of serial port communication between Wecon V-BOX and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
53 53  
54 -(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity same with PLC.
50 +**Software configuration of PLC**
55 55  
56 -(% class="mark" %)WECON PLC RS422 port,default communication parameters is 9600,1,7,ZEVEN
52 +**1)PLC programming software**
57 57  
54 +[[image:image-20220824142722-1.png]]
55 +
56 +**2)New PLC project**
57 +
58 +Click New Project and select the PLC model.
59 +
60 +[[image:image-20220822172623-2.png]]
61 +
62 +**3)Set Serial port parameters**
63 +
64 +Follow the steps below to configure Serial port parameters
65 +
66 +Baud rate:115200
67 +
68 +Data bit:8
69 +
70 +Stop bit:1
71 +
72 +Parity:No verification
73 +
74 +[[image:image-20220822172657-3.png]]
75 +
76 +**4)Registers list**
77 +
78 +[[image:image-20220822172730-4.png]]
79 +
80 +**V-BOX software configuration**
81 +
82 +**1)V-BOX programming software**
83 +
84 + [[image:image-20220824104124-1.png]]
85 +
86 +**2)V-NET add device**
87 +
88 +Open V-NET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the access key, password and remark, to add the device.
89 +
90 +[[image:image-20220824104909-2.png]]
91 +
92 +
93 +**3)Set communication port parameters**
94 +
95 +Click the communication configuration button on the left to find the communication protocol with LX5V. After selecting the protocol, configure the communication parameters of the COM port.
96 +
97 +Baud rate:115200
98 +
99 +Data bit:8
100 +
101 +Stop bit:1
102 +
103 +Parity:No verification
104 +
105 +[[image:image-20220824142130-1.png]]
106 +
107 +**hardware connection**
108 +
109 +**1)Hardware wiring diagram**
110 +
111 +This example introduces WeconHMI with LX5V PLC to establish communication through serial port. The connection diagram is as follows:
112 +
113 +[[image:image-20220824142546-2.png]]
114 +
115 +[[image:image-20220824142643-3.png]]
116 +
117 +
118 +
119 +The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC.
120 +
121 +== **LX5V-N Ethernet protocol** ==
122 +
123 + This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
124 +
125 +**Software configuration of PLC**
126 +
127 +**1)PLC programming software**
128 +
129 +[[image:image-20220810164710-1.png]]
130 +
131 +**2)New PLC project**
132 +
133 +Click New Project and select the PLC model.
134 +
135 +[[image:image-20220811115454-1.png]]
136 +
137 +**3)Set Ethernet port parameters**
138 +
139 +Follow the steps below to configure Ethernet parameters
140 +
141 +PLC IP address:192.168.39.200
142 +
143 +default gateway:192.168.39.1
144 +
145 +subnet mask:255.255.255.0
146 +
147 +[[image:image-20220811140530-2.png]]
148 +
149 +**4)Registers list**
150 +
151 +[[image:image-20220811102219-3.png]]
152 +
153 +**HMI software configuration**
154 +
155 +**1)HMI programming software**
156 +
157 + [[image:image-20220810171237-4.png]]
158 +
159 +**2)New HMI project**
160 +
161 +Click New Project and select the HMI model.
162 +
163 +[[image:image-20220810172010-5.png]]
164 +
165 +**3)Set communication port parameters**
166 +
167 +Click the project setting button on the left to configure the IP address of the HMI machine to ensure that the HMI and PLC IP remain in a local area network.
168 +
169 +HMI IP address:192.168.39.201
170 +
171 +default gateway:192.168.39.1
172 +
173 +subnet mask:255.255.255.0
174 +
175 +[[image:image-20220811170753-2.png]]
176 +
177 +Next, click Communication Settings to configure the IP of the HMI communication object.
178 +
179 +[[image:image-20220811163047-1.png]]
180 +
181 +**hardware connection**
182 +
183 +**1)Hardware wiring diagram**
184 +
185 +This example introduces WeconHMI with LX5V-N PLC to establish communication through ethernet. The connection diagram is as follows:
186 +
187 +[[image:image-20220811170248-1.png]]
188 +
189 +The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC.
190 +
58 58  (% style="text-align:center" %)
59 59  [[image:1624348978863-771.png||queryString="width=812&height=494" height="487" width="800" class="img-thumbnail"]]
60 60  
61 -(% class="wikigeneratedid" %)
62 -== ==
194 += **Rockwell PLC** =
63 63  
64 -== **2 Communication with Allen-Bradley CompactLogix L1769** ==
196 +== (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** ==
65 65  
66 -(((
67 -This example introduces the establishment of Ethernet communication between Wecon V-box and Allen-Bradley L1769. It is introduced through three parts: PLC software configuration, V-box software configuration, and hardware wiring.
198 +MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
68 68  
69 -
200 +**HMI Settings**
201 +
202 +|**Item**|**Settings**|**Note**
203 +|Protocol|Allen-Bradlley MicroLogix|
204 +|Connection|RS232|
205 +|Baud rate|19200|
206 +|Data bit|8|
207 +|Parity|None|
208 +|Stop bit|1|
209 +|PLC station No.|1|
210 +
211 +**Address List**
212 +
213 +|**Type**|**Device registers**|**Format**|**Range**|**Note**
214 +|(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15|
215 +|O|O d.d|0.0~~255.15|
216 +|B|B nnhh.dd|0.0~~ffff.15|nn: block number (hex)
217 +|S|S d.d|0.0~~255.15|
218 +|N|N nnhh.dd|0.0~~ffff.15|nn: block number (hex)
219 +|(% rowspan="9" %)Word|S|S d|0~~255|
220 +|TS|TS nnhh|0~~ffff|(% rowspan="8" %)nn: block number (hex)
221 +|TP|TP nnhh|0~~ffff
222 +|CS|CS nnhh|0~~ffff
223 +|CP|CP nnhh|0~~ffff
224 +|N|N nnhh|0~~ffff
225 +|C|C nnhh|0~~ffff
226 +|T|T nnhh|0~~ffff
227 +|R|R nnhh|0~~ffff
228 +
229 +**Cable Wiring**
230 +
231 +[[image:image-20220824110724-1.png]]
232 +
233 +
234 +
235 +== **CompactLogix Protocol** ==
236 +
237 +(((
238 +(((
239 +This example introduces the establishment of Ethernet communication between Wecon V-box and CompactLogix L1769. It is introduced through three parts: PLC software configuration, V-box software configuration, and hardware wiring.
70 70  )))
241 +)))
71 71  
72 72  (((
73 73  (% class="wikigeneratedid" id="HSoftwareconfigurationofPLC" %)
... ... @@ -80,7 +80,7 @@
80 80  **1)PLC programming software**
81 81  )))
82 82  
83 -[[image:image-20220714113935-3.png||height="324" width="270"]]
254 +[[image:image-20220714162600-1.png]]
84 84  
85 85  (% class="wikigeneratedid" id="HNewPLCproject" %)
86 86  (((
... ... @@ -88,15 +88,19 @@
88 88  )))
89 89  
90 90  (((
262 +(((
91 91  Click New Project and select the PLC model.
92 92  )))
265 +)))
93 93  
94 94  (((
95 -[[image:image-20220714114247-4.png||height="298" width="552"]] [[image:image-20220714114257-5.png||height="445" width="551"]]
268 +[[image:image-20220714162617-2.png]]
96 96  )))
97 97  
98 98  (((
99 99  
273 +
274 +[[image:image-20220714162652-4.png]]
100 100  )))
101 101  
102 102  (((
... ... @@ -107,30 +107,38 @@
107 107  
108 108  (((
109 109  (((
285 +(((
110 110  Follow the steps below to configure Ethernet parameters
111 111  )))
112 112  )))
289 +)))
113 113  
114 114  (((
115 115  (((
293 +(((
116 116  PLC IP address:192.168.40.101
117 117  )))
118 118  )))
297 +)))
119 119  
120 120  (((
121 121  (((
301 +(((
122 122  default gateway:192.168.40.1
123 123  )))
124 124  )))
305 +)))
125 125  
126 126  (((
127 127  (((
309 +(((
128 128  subnet mask:255.255.255.0
129 129  )))
130 130  )))
313 +)))
131 131  
132 132  (((
133 -[[image:image-20220714115012-6.png]]
316 +[[image:image-20220714162713-5.png]]
134 134  )))
135 135  
136 136  (((
... ... @@ -150,7 +150,7 @@
150 150  
151 151  (% class="wikigeneratedid" %)
152 152  (((
153 - [[image:image-20220714115214-7.png||height="276" width="456"]]
336 + [[image:image-20220714162725-6.png]]
154 154  )))
155 155  
156 156  (% class="wikigeneratedid" id="HConfiguredevicenetwork" %)
... ... @@ -160,13 +160,21 @@
160 160  
161 161  (((
162 162  (((
346 +(((
163 163  Click the Configuration Download button[[image:image-20220714115308-8.png||height="22" width="15"]], It is used to configure the device network, update the device time, obtain the device machine code, check the device network, etc.
164 164  )))
349 +
350 +(((
351 +In the example below, the IP address of V-Box is configured as 192.168.40.66, and the networking method is 4G connection
165 165  )))
353 +)))
354 +)))
166 166  
167 167  (((
168 168  (((
169 -In the example below, the IP address of V-Box is configured as 192.168.40.66, and the networking method is 4G connection [[image:image-20220714115440-9.png||height="425" width="791"]]
358 +[[image:image-20220714162737-7.png]]
359 +
360 +
170 170  )))
171 171  )))
172 172  )))
... ... @@ -179,10 +179,10 @@
179 179  )))
180 180  
181 181  (((
182 -Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device.   [[image:image-20220714115640-10.png||height="430" width="797"]]
373 +(((
374 +Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device.   [[image:image-20220714162752-8.png]]
183 183  )))
184 184  
185 -(((
186 186  
187 187  )))
188 188  
... ... @@ -192,61 +192,156 @@
192 192  **4)Set communication port parameters**
193 193  )))
194 194  
195 -In the device list on the left, find the Vbox that communicates with the L1769, click it and select configuration,communication port configuration in the main interface to add a communication protocol. [[image:image-20220714115848-11.png||height="432" width="802"]]
386 +(((
387 +In the device list on the left, find the Vbox that communicates with the L1769, click it and select configuration,communication port configuration in the main interface to add a communication protocol.
196 196  )))
197 197  
390 +[[image:image-20220714162805-9.png]]
391 +)))
392 +
393 +(((
198 198  The communication port is selected as Ethernet, the device type is selected as Allen-Bradley, the protocol is Allen-BradleyMicro850_FreeTag EthemetIP, and the IP is the internal IP address of the L1769 PLC. The port number is 44818.
395 +)))
199 199  
200 -[[image:image-20220714143820-1.png]]
397 +[[image:image-20220714162814-10.png]]
201 201  
202 -After adding the protocol Allen-BradleyMicro850_FreeTag, click[[image:image-20220714143838-2.png]]icon add label.
203 203  
204 -[[image:image-20220714143849-3.png]]
400 +(((
401 +After adding the protocol Allen-BradleyMicro850_FreeTag, click[[image:image-20220714143838-2.png]]icon add label.[[image:image-20220714162827-11.png]]
402 +)))
205 205  
404 +(% class="wikigeneratedid" id="HEngineeringproduction" %)
405 +(((
406 +**5)Engineering production**
407 +)))
206 206  
207 -== Engineering production ==
409 +(% class="wikigeneratedid" %)
410 +(((
411 +(((
412 +According to your own needs, use the V-NET client software to edit the required data monitoring points.
413 +)))
208 208  
415 +[[image:image-20220714162841-12.png]]
209 209  
210 -== **Siemens S7-1200** ==
211 211  
212 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]]
418 +(((
419 +**hardware connection**
420 +)))
421 +)))
213 213  
423 +(((
424 +**1)Hardware wiring diagram**
425 +)))
426 +
427 +(((
428 +(((
429 +This example introduces Wecon V-box with Allen-Bradley L1769 PLC to establish communication through Ethernet. The connection diagram is as follows:
430 +)))
431 +
432 +[[image:image-20220714162856-13.png]]
433 +
434 +(((
435 +The above are all the steps for establishing Ethernet communication between Wecon V-box with CompactLogix L1769 PLC.
436 +
437 +
214 214  == **Allen-Bradley Ethernet DF1** ==
215 215  
216 216  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]]
217 217  
218 -== **Communication with S7-200 Smart** ==
219 219  
220 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]]
443 += **Siemens PLC** =
221 221  
222 -== **Delta DVP Ethernet** ==
445 +== **S7-200 Smart Ethernet Protocol** ==
223 223  
224 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
447 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]]
448 +)))
449 +)))
225 225  
226 -== **Delta DVP Serial Protocol** ==
451 +== **S7-1200 Ethernet Protocol** ==
227 227  
228 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
453 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]]
229 229  
230 -== **Communicate with Mitsubishi FX Series** ==
455 += **Mitsubishi PLC** =
231 231  
457 +== **Mitsubishi FX Series Protocol** ==
458 +
232 232  [[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20Mitsubishi%20FX%20Series.zip]]
233 233  
234 -== **Communicate with VB inverter** ==
461 += **Delta PLC** =
235 235  
236 -[[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20VB%20inverter.zip]]
463 +== **DVP Ethernet Protocol** ==
237 237  
238 -== **Omron CP1 Series** ==
465 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
239 239  
467 +== **DVP Serial Protocol** ==
468 +
469 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
470 +
471 += **Omron PLC** =
472 +
473 +== **CP1 Series Protocol** ==
474 +
240 240  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]]
241 241  
242 -== **Omron CJ2M** ==
477 +== **CJ2M Series Protocol** ==
243 243  
244 244  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]]
245 245  
246 -= **2 User define protocol** =
481 += **Modbus RTU** =
247 247  
248 -More serial port script instruction,please refer manual:[[Lua script function>>doc:V-BOX.V-Net.1\.User Manual.04 Lua Script.01 Lua Functions.WebHome]]~-~-->[[3.Serial port operation>>url:http://docs.we-con.com.cn/wiki/vbox/view/HMI/04.Lua%20script%20%20function%20and%20operation/01.Lua%20script%20function/#H3.Serialportoperation]]
483 +== **V-BOX as master** ==
249 249  
485 +Select the protocol “(% class="mark" %)Modbus RTU Slave(All Fuction)”,
486 +
487 +(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity
488 +
489 +(% style="text-align:center" %)
490 +[[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]]
491 +
492 +== **V-BOX as slave** ==
493 +
494 +Select the protocol “(% class="mark" %)**Modbus RTU Master”**,
495 +
496 +(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity
497 +
498 +(% style="text-align:center" %)
499 +[[image:1624348709622-711.png||queryString="width=809&height=493" height="488" width="800" class="img-thumbnail"]]
500 +
501 +**Address List**
502 +
503 +(% class="table-bordered" %)
504 +|**Type**|**Register**|**Function code & Description**
505 +|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers)
506 +|06 (write single register: write a binary value to a holding register)
507 +|10 (write values to multiple addresses )
508 +|(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers)
509 +|06 (write single register: write a binary value to a holding register)
510 +|10 (write values to multiple addresses )
511 +|(% rowspan="3" %)W6|03 (read holding register: read current binary value in one or more holding registers)
512 +|06 (write single register: write a binary value to a holding register)
513 +|10 (write values to multiple addresses )
514 +|(% rowspan="2" %)W16|03 (read holding register: read current binary value in one or more holding registers)
515 +|10 (write values to multiple addresses )
516 +|(% rowspan="11" %)Bit|(% rowspan="3" %)0|01 (Read coil state)
517 +|05 (Force a single coil to force the on/off state of a logic coil)
518 +|0F (Write multiple bits, ie write continuously)
519 +|(% rowspan="3" %)1|02 (Read the input state)
520 +|05 (Force a single coil to force the on/off state of a logic coil)
521 +|0F (Write multiple bits)
522 +|(% rowspan="3" %)W5|01 (Read coil state to obtain the current state of a set of logic coils)
523 +|05 (Force a single coil to force the on/off state of a logic coil)
524 +|0F (Write multiple bits)
525 +|(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils)
526 +|0F (Write multiple bits)
527 +
528 +== **communicate with VB inverter** ==
529 +
530 +[[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20VB%20inverter.zip]]
531 +
532 += **User define protocol** =
533 +
534 +More serial port script instruction,please refer manual:[[Lua script function>>doc:V-BOX.V-Net.Manual.04 Lua Script.01 Lua Functions.WebHome]]~-~-->[[3.Serial port operation>>url:http://docs.we-con.com.cn/wiki/vbox/view/HMI/04.Lua%20script%20%20function%20and%20operation/01.Lua%20script%20function/#H3.Serialportoperation]]
535 +
250 250  == **Read the temperature sensor.** ==
251 251  
252 252  the commond format is as beliow:
image-20220714160006-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +1.3 MB
Content
image-20220714160034-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +135.2 KB
Content
image-20220714160120-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +58.8 KB
Content
image-20220714160335-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +264.1 KB
Content
image-20220714160412-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +58.5 KB
Content
image-20220714160439-6.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +104.0 KB
Content
image-20220714160541-7.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +13.7 KB
Content
image-20220714160651-8.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +135.2 KB
Content
image-20220714160843-9.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +165.9 KB
Content
image-20220714160943-10.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +50.2 KB
Content
image-20220714161014-11.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +94.3 KB
Content
image-20220714161120-12.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +94.3 KB
Content
image-20220714161229-13.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +62.5 KB
Content
image-20220714161445-14.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +131.2 KB
Content
image-20220714162600-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +58.8 KB
Content
image-20220714162617-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +1.3 MB
Content
image-20220714162629-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +58.5 KB
Content
image-20220714162652-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +58.5 KB
Content
image-20220714162713-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +104.0 KB
Content
image-20220714162725-6.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +13.7 KB
Content
image-20220714162737-7.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +135.2 KB
Content
image-20220714162752-8.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +135.2 KB
Content
image-20220714162805-9.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +165.9 KB
Content
image-20220714162814-10.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +50.2 KB
Content
image-20220714162827-11.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +94.3 KB
Content
image-20220714162841-12.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +62.5 KB
Content
image-20220714162856-13.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +131.6 KB
Content
image-20220820164423-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +18.4 KB
Content
image-20220822172124-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +38.7 KB
Content
image-20220822172228-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +48.8 KB
Content
image-20220822172553-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +19.9 KB
Content
image-20220822172623-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +111.2 KB
Content
image-20220822172657-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +141.6 KB
Content
image-20220822172730-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +130.7 KB
Content
image-20220824104124-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +14.6 KB
Content
image-20220824104909-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +278.8 KB
Content
image-20220824110724-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +79.1 KB
Content
image-20220824120406-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +31.9 KB
Content
image-20220824120507-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +10.3 KB
Content
image-20220824120524-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +23.4 KB
Content
image-20220824120547-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +49.2 KB
Content
image-20220824120614-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +30.9 KB
Content
image-20220824142130-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +122.2 KB
Content
image-20220824142546-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +111.2 KB
Content
image-20220824142643-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +38.3 KB
Content
image-20220824142722-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +7.3 KB
Content