Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -436,7 +436,7 @@ 436 436 437 437 Supported Series: Siemens S7-300 series PLC 438 438 439 -**1) PLCSetting**439 +**1)V-BOX setting** 440 440 441 441 |**Items**|**Settings**|**Note** 442 442 |Protocol|Simens S7-300 Ethernet| ... ... @@ -498,7 +498,7 @@ 498 498 499 499 Supported Series: Siemens S7-400, S7-1200 and S7-1500 500 500 501 -**1) PLCSetting**501 +**1)V-BOX setting** 502 502 503 503 |=**Items**|=**Settings**|=**Note** 504 504 |Protocol|Siemens S7-XXX| ... ... @@ -1312,6 +1312,41 @@ 1312 1312 1313 1313 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830160232-3.png?rev=1.1||alt="image-20220830160232-3.png"]] 1314 1314 1315 + 1316 += Create communication with **Schneider PLC** = 1317 + 1318 +== **Schneider MODBUS RTU** == 1319 + 1320 +**1)V-BOX Setting** 1321 + 1322 +|=**Parameters**|=**Recommended**|=**Notes** 1323 +|**Protocol**|(% colspan="1" %)Schneider MODBUS RTU| 1324 +|**Connection**|RS485| 1325 +|**Baud rate**|19200| 1326 +|**Data bit**|8| 1327 +|**Parity**|Even| 1328 +|**Stop bit**|1| 1329 +|**PLC station No.**|1| 1330 + 1331 +**2)Address List** 1332 + 1333 +|=**Bit/Word**|=**Device type**|=**Format**|=**Range**|=**Memo** 1334 +|B|IX|DDDDDo|0 ~~ 655357|Input bit (read only) 1335 +|B|QX|DDDDDo|0 ~~ 655357|Write multiple coils 1336 +|B|MX|DDDDDDo|0 ~~ 9999997|Output register bit (octal) 1337 +|W|MW|DDDDDD|0 ~~ 999999|Output register 1338 +|DW|MD|DDDDDD|0 ~~ 999999|Output register 1339 + 1340 +**3)Configure the communication protocol** 1341 + 1342 +[[image:image-20220902104329-1.png]] 1343 + 1344 +**4)Cable Wiring** 1345 + 1346 +**RS-485 2W **(RJ45 Connector): The following is the view from the soldering point of a connector. 1347 + 1348 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220817154212-1.jpeg?width=554&height=315&rev=1.1||alt="image-20220817154212-1.jpeg" height="315" width="554"]] 1349 + 1315 1315 = Create communication with Inovance** PLC** = 1316 1316 1317 1317 == **H3U serial protocol** == ... ... @@ -1511,9 +1511,9 @@ 1511 1511 1512 1512 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 1513 1513 1514 -= Create communication with **Modbus RTU** =1549 += Create communication with **Modbus ** = 1515 1515 1516 -== ** V-BOXasSlave** ==1551 +== **MODBUS RTU Slave (All function)** == 1517 1517 1518 1518 Select the protocol "Modbus RTU Slave (All Fuction)", 1519 1519 ... ... @@ -1522,7 +1522,7 @@ 1522 1522 (% style="text-align:center" %) 1523 1523 [[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]] 1524 1524 1525 -== ** V-BOXasMaster** ==1560 +== **MODBUS RTU Master** == 1526 1526 1527 1527 Select the protocol "Modbus RTU Master", 1528 1528 ... ... @@ -1558,6 +1558,67 @@ 1558 1558 |(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils) 1559 1559 |0F (Write multiple bits) 1560 1560 1596 +== **MODBUS TCP Slave (All function)** == 1597 + 1598 +Supported series: MODBUS TCP controller 1599 + 1600 +HMI works as MODBUS TCP MASTER connecting with TCP SLAVE 1601 + 1602 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8877cb7f39c2b607.png?width=544&height=571&rev=1.1||alt="12.PLC Protocol_html_8877cb7f39c2b607.png" height="571" width="544"]] 1603 + 1604 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_e7e1f06f127a9175.png?width=553&height=426&rev=1.1||alt="12.PLC Protocol_html_e7e1f06f127a9175.png" height="426" width="553"]] 1605 + 1606 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_60bbfe5de79417a6.png?width=553&height=163&rev=1.1||alt="12.PLC Protocol_html_60bbfe5de79417a6.png" height="163" width="553"]] 1607 + 1608 +**HMI Setting** 1609 + 1610 +|**Items**|**Settings**|**Note** 1611 +|Protocol|MODBUS TCP Slave (All function)| 1612 +|Connection|Ethernet| 1613 +|Port No.|502| 1614 +|PLC station No.|1| 1615 + 1616 +**Address List** 1617 + 1618 +|**Type**|**Register**|**Function code & Description** 1619 +|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers) 1620 +|06 (write single register: write a binary value to a holding register) 1621 +|10 (write values to multiple addresses ) 1622 +|(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers) 1623 +|06 (write single register: write a binary value to a holding register) 1624 +|10 (write values to multiple addresses ) 1625 +|(% rowspan="3" %)W6|03 (read holding register: read current binary value in one or more holding registers) 1626 +|06 (write single register: write a binary value to a holding register) 1627 +|10 (write values to multiple addresses ) 1628 +|(% rowspan="2" %)W16|03 (read holding register: read current binary value in one or more holding registers) 1629 +|10 (write values to multiple addresses ) 1630 +|(% rowspan="11" %)Bit|(% rowspan="3" %)0|01 (Read coil state) 1631 +|05 (Force a single coil to force the on/off state of a logic coil) 1632 +|0F (Write multiple bits, ie write continuously) 1633 +|(% rowspan="3" %)1|02 (Read the input state) 1634 +|05 (Force a single coil to force the on/off state of a logic coil) 1635 +|0F (Write multiple bits) 1636 +|(% rowspan="3" %)W5|01 (Read coil state to obtain the current state of a set of logic coils) 1637 +|05 (Force a single coil to force the on/off state of a logic coil) 1638 +|0F (Write multiple bits) 1639 +|(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils) 1640 +|0F (Write multiple bits) 1641 + 1642 +**Communication Settings** 1643 + 1644 +Enable HMI Ethernet in [Project Settings]; 1645 + 1646 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_43b671f18153910d.png?width=405&height=107&rev=1.1||alt="12.PLC Protocol_html_43b671f18153910d.png" height="107" width="405"]] 1647 + 1648 +Set PLC IP in [Device IP] settings; 1649 + 1650 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_4bd3cc8348adecf8.png?width=554&height=190&rev=1.1||alt="12.PLC Protocol_html_4bd3cc8348adecf8.png" height="190" width="554"]] 1651 + 1652 +**Cable Wiring** 1653 + 1654 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 1655 + 1656 + 1561 1561 == **communicate with VB inverter** == 1562 1562 1563 1563 [[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20VB%20inverter.zip]]
- image-20220902104329-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +58.7 KB - Content