... ... @@ -436,7 +436,7 @@
436 436  
437 437  Supported Series: Siemens S7-300 series PLC
438 438  
439 -**1)PLC Setting**
439 +**1)V-BOX setting**
440 440  
441 441  |**Items**|**Settings**|**Note**
442 442  |Protocol|Simens S7-300 Ethernet|
... ... @@ -498,7 +498,7 @@
498 498  
499 499  Supported Series: Siemens S7-400, S7-1200 and S7-1500
500 500  
501 -**1)PLC Setting**
501 +**1)V-BOX setting**
502 502  
503 503  |=**Items**|=**Settings**|=**Note**
504 504  |Protocol|Siemens S7-XXX|
... ... @@ -704,6 +704,109 @@
704 704  [[image:image-20220825100845-4.png]]
705 705  
706 706  
707 +== **FX3U Ethernet Protocol** ==
708 +
709 + Mitsubishi FX3U series PLC
710 +
711 +**HMI Settings**
712 +
713 +|Items|Settings|Note
714 +|Protocol|Mitsubishi FX3U|
715 +|Connection|Ethernet|
716 +|Port No.|5009|Must be the same as the PLC setting
717 +|PLC station No.|0|
718 +
719 +**Address List**
720 +
721 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
722 +|(% colspan="1" rowspan="7" %)Bit|X|X|X OOO|0~~377|
723 +|Y|Y|Y OOO|0~~377|
724 +|M|M|M DDDD|0~~7679|
725 +|SM|SM|SM DDDD|8000~~8511|
726 +|S|S|S DDDD|0~~4095|
727 +|TS|TS|TS DDD|0~~511|
728 +|CS|CS|CS DDD|0~~255|
729 +|(% colspan="1" rowspan="9" %)Word|CN|CN|CN DDD|0~~199|
730 +|TN|TN|TN DDD|0~~511|
731 +|D|D|D DDDD|0~~7999|
732 +|SD|SD|SD DDDD|8000~~8511|
733 +|R|R|R DDDDD|0~~32767|
734 +
735 +**Ethernet Module Settings**
736 +
737 +FX3U-ENET-L module configuration
738 +Set up the FX3U-ENET-L Ethernet module settings as follows.
739 +Select the module location, which in this document is Module 0.
740 +
741 +[[image:image-20221116094003-1.png]]
742 +
743 +
744 +Select "Operational setting" to enter the following screen.
745 +
746 +The Ethernet module IP is set to 192.168.39.254 in this document, and other options are default.
747 +
748 +[[image:image-20221116094019-2.png]]
749 +
750 +
751 +Select "Open setting" to enter the setting interface, the settings are as follows.
752 +
753 +The third item "Protocol" selects TCP, and "Open system" selects MELSOFT connection, which allows the
754 +
755 +Mitsubishi programming software GX works2 to communicate with the FX3U via the Ethernet module.
756 +
757 +[[image:image-20221116094038-3.png]]
758 +
759 +
760 +Click on "transter setup" - "PC side I/F setting", see the following figure.
761 +
762 +After setting, the first download must use the programming cable, as shown in the figure; after that, can
763 +
764 +use the IP set in the "Ethernet board" to communicate directly with the network cable.
765 +
766 +[[image:image-20221116094122-4.png||height="422" width="707"]]
767 +
768 +
769 +Read and write data from the Ethernet module
770 +
771 +[[image:image-20221116094131-5.png||height="551" width="708"]]
772 +
773 +
774 +Set "Transter setup" to COM communication, and read or write operation as shown below
775 +
776 +[[image:image-20221116094150-6.png]]
777 +
778 +
779 +**PLC Settings (GX Works 2)**
780 +
781 +Create a blank FX5U project
782 +
783 +Find Current Connection in the navigation
784 +
785 +[[image:image-20221116094206-7.png||height="425" width="711"]]
786 +
787 +
788 +Select Connection Channel List
789 +
790 +Select Ethernet board communication
791 +
792 +[[image:image-20221116094709-9.png||height="427" width="715"]]
793 +
794 +
795 +Select Ethernet Module
796 +Set the IP address of the PLC
797 +
798 +[[image:image-20221116094736-11.png||height="682" width="716"]]
799 +
800 +
801 +Read or write PLC data, in this document is read
802 +
803 +[[image:image-20221116094755-12.png||height="426" width="715"]]
804 +
805 +[[image:image-20221116094803-13.png||height="427" width="715"]]
806 +
807 +
808 +
809 +
707 707  == **FX5U Serial Protocol** ==
708 708  
709 709  Mitsubishi FX5U series PLC
... ... @@ -1312,6 +1312,41 @@
1312 1312  
1313 1313  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830160232-3.png?rev=1.1||alt="image-20220830160232-3.png"]]
1314 1314  
1418 +
1419 += Create communication with **Schneider PLC** =
1420 +
1421 +== **Schneider MODBUS RTU** ==
1422 +
1423 +**1)V-BOX Setting**
1424 +
1425 +|=**Parameters**|=**Recommended**|=**Notes**
1426 +|**Protocol**|(% colspan="1" %)Schneider MODBUS RTU|
1427 +|**Connection**|RS485|
1428 +|**Baud rate**|19200|
1429 +|**Data bit**|8|
1430 +|**Parity**|Even|
1431 +|**Stop bit**|1|
1432 +|**PLC station No.**|1|
1433 +
1434 +**2)Address List**
1435 +
1436 +|=**Bit/Word**|=**Device type**|=**Format**|=**Range**|=**Memo**
1437 +|B|IX|DDDDDo|0 ~~ 655357|Input bit (read only)
1438 +|B|QX|DDDDDo|0 ~~ 655357|Write multiple coils
1439 +|B|MX|DDDDDDo|0 ~~ 9999997|Output register bit (octal)
1440 +|W|MW|DDDDDD|0 ~~ 999999|Output register
1441 +|DW|MD|DDDDDD|0 ~~ 999999|Output register
1442 +
1443 +**3)Configure the communication protocol**
1444 +
1445 +[[image:image-20220902104329-1.png]]
1446 +
1447 +**4)Cable Wiring**
1448 +
1449 +**RS-485 2W **(RJ45 Connector): The following is the view from the soldering point of a connector.
1450 +
1451 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220817154212-1.jpeg?width=554&height=315&rev=1.1||alt="image-20220817154212-1.jpeg" height="315" width="554"]]
1452 +
1315 1315  = Create communication with Inovance** PLC** =
1316 1316  
1317 1317  == **H3U serial protocol** ==
... ... @@ -1511,9 +1511,9 @@
1511 1511  
1512 1512  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1513 1513  
1514 -= Create communication with **Modbus RTU** =
1652 += Create communication with **Modbus ** =
1515 1515  
1516 -== **V-BOX as Slave** ==
1654 +== **MODBUS RTU Slave (All function)** ==
1517 1517  
1518 1518  Select the protocol "Modbus RTU Slave (All Fuction)",
1519 1519  
... ... @@ -1522,7 +1522,7 @@
1522 1522  (% style="text-align:center" %)
1523 1523  [[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]]
1524 1524  
1525 -== **V-BOX as Master** ==
1663 +== **MODBUS RTU Master** ==
1526 1526  
1527 1527  Select the protocol "Modbus RTU Master",
1528 1528  
... ... @@ -1558,6 +1558,61 @@
1558 1558  |(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils)
1559 1559  |0F (Write multiple bits)
1560 1560  
1699 +== **MODBUS TCP Slave (All function)** ==
1700 +
1701 +Supported series: MODBUS TCP controller
1702 +
1703 +V-B0X works as MODBUS TCP MASTER connecting with TCP SLAVE
1704 +
1705 +**1)V-BOX Setting**
1706 +
1707 +|**Items**|**Settings**|**Note**
1708 +|Protocol|MODBUS TCP Slave (All function)|
1709 +|Connection|Ethernet|
1710 +|Port No.|502|
1711 +|PLC station No.|1
1712 +
1713 +**2)Address List**
1714 +
1715 +|**Type**|**Register**|**Function code & Description**
1716 +|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers)
1717 +|06 (write single register: write a binary value to a holding register)
1718 +|10 (write values to multiple addresses )
1719 +|(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers)
1720 +|06 (write single register: write a binary value to a holding register)
1721 +|10 (write values to multiple addresses )
1722 +|(% rowspan="3" %)W6|03 (read holding register: read current binary value in one or more holding registers)
1723 +|06 (write single register: write a binary value to a holding register)
1724 +|10 (write values to multiple addresses )
1725 +|(% rowspan="2" %)W16|03 (read holding register: read current binary value in one or more holding registers)
1726 +|10 (write values to multiple addresses )
1727 +|(% rowspan="11" %)Bit|(% rowspan="3" %)0|01 (Read coil state)
1728 +|05 (Force a single coil to force the on/off state of a logic coil)
1729 +|0F (Write multiple bits, ie write continuously)
1730 +|(% rowspan="3" %)1|02 (Read the input state)
1731 +|05 (Force a single coil to force the on/off state of a logic coil)
1732 +|0F (Write multiple bits)
1733 +|(% rowspan="3" %)W5|01 (Read coil state to obtain the current state of a set of logic coils)
1734 +|05 (Force a single coil to force the on/off state of a logic coil)
1735 +|0F (Write multiple bits)
1736 +|(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils)
1737 +|0F (Write multiple bits)
1738 +
1739 +**3)Communication Settings**
1740 +
1741 +Configure V-BOX Ethernet IP in Networking Settings
1742 +
1743 +[[image:image-20220902111833-3.png]]
1744 +
1745 +
1746 +Configure PLC Ethernet IP in Communication;
1747 +
1748 +[[image:image-20220902111121-1.png]]
1749 +
1750 +**4)Cable Wiring**
1751 +
1752 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1753 +
1561 1561  == **communicate with VB inverter** ==
1562 1562  
1563 1563  [[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20VB%20inverter.zip]]
image-20220902104329-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +58.7 KB
Content
image-20220902111121-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +60.9 KB
Content
image-20220902111754-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +57.6 KB
Content
image-20220902111833-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +56.1 KB
Content