... ... @@ -1317,11 +1317,11 @@
1317 1317  
1318 1318  == **Schneider MODBUS RTU** ==
1319 1319  
1320 -**HMI Setting**
1320 +**1)V-BOX Setting**
1321 1321  
1322 1322  |=**Parameters**|=**Recommended**|=**Notes**
1323 1323  |**Protocol**|(% colspan="1" %)Schneider MODBUS RTU|
1324 -|Connection|RS485|
1324 +|**Connection**|RS485|
1325 1325  |**Baud rate**|19200|
1326 1326  |**Data bit**|8|
1327 1327  |**Parity**|Even|
... ... @@ -1328,12 +1328,8 @@
1328 1328  |**Stop bit**|1|
1329 1329  |**PLC station No.**|1|
1330 1330  
1331 -**PLC Setting**
1331 +**2)Address List**
1332 1332  
1333 -|=**Communication mode**|Modbus RTU protocol
1334 -
1335 -**Device Address**
1336 -
1337 1337  |=**Bit/Word**|=**Device type**|=**Format**|=**Range**|=**Memo**
1338 1338  |B|IX|DDDDDo|0 ~~ 655357|Input bit (read only)
1339 1339  |B|QX|DDDDDo|0 ~~ 655357|Write multiple coils
... ... @@ -1341,8 +1341,12 @@
1341 1341  |W|MW|DDDDDD|0 ~~ 999999|Output register
1342 1342  |DW|MD|DDDDDD|0 ~~ 999999|Output register
1343 1343  
1344 -**Wiring Diagram**
1340 +**3)Configure the communication protocol**
1345 1345  
1342 +[[image:image-20220902104329-1.png]]
1343 +
1344 +**4)Cable Wiring**
1345 +
1346 1346  **RS-485 2W **(RJ45 Connector): The following is the view from the soldering point of a connector.
1347 1347  
1348 1348  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220817154212-1.jpeg?width=554&height=315&rev=1.1||alt="image-20220817154212-1.jpeg" height="315" width="554"]]
image-20220902104329-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +58.7 KB
Content