Changes for page 1 Communication

Last modified by Hunter on 2024/07/01 10:54

From version 160.1
edited by Ben
on 2022/09/02 10:45
Change comment: There is no comment for this version
To version 158.1
edited by Ben
on 2022/09/02 10:14
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1317,11 +1317,11 @@
1317 1317  
1318 1318  == **Schneider MODBUS RTU** ==
1319 1319  
1320 -**1)V-BOX Setting**
1320 +**HMI Setting**
1321 1321  
1322 1322  |=**Parameters**|=**Recommended**|=**Notes**
1323 1323  |**Protocol**|(% colspan="1" %)Schneider MODBUS RTU|
1324 -|**Connection**|RS485|
1324 +|Connection|RS485|
1325 1325  |**Baud rate**|19200|
1326 1326  |**Data bit**|8|
1327 1327  |**Parity**|Even|
... ... @@ -1328,8 +1328,12 @@
1328 1328  |**Stop bit**|1|
1329 1329  |**PLC station No.**|1|
1330 1330  
1331 -**2)Address List**
1331 +**PLC Setting**
1332 1332  
1333 +|=**Communication mode**|Modbus RTU protocol
1334 +
1335 +**Device Address**
1336 +
1333 1333  |=**Bit/Word**|=**Device type**|=**Format**|=**Range**|=**Memo**
1334 1334  |B|IX|DDDDDo|0 ~~ 655357|Input bit (read only)
1335 1335  |B|QX|DDDDDo|0 ~~ 655357|Write multiple coils
... ... @@ -1337,12 +1337,8 @@
1337 1337  |W|MW|DDDDDD|0 ~~ 999999|Output register
1338 1338  |DW|MD|DDDDDD|0 ~~ 999999|Output register
1339 1339  
1340 -**3)Configure the communication protocol**
1344 +**Wiring Diagram**
1341 1341  
1342 -[[image:image-20220902104329-1.png]]
1343 -
1344 -**4)Cable Wiring**
1345 -
1346 1346  **RS-485 2W **(RJ45 Connector): The following is the view from the soldering point of a connector.
1347 1347  
1348 1348  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220817154212-1.jpeg?width=554&height=315&rev=1.1||alt="image-20220817154212-1.jpeg" height="315" width="554"]]
image-20220902104329-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -58.7 KB
Content