Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 3 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1546,9 +1546,9 @@ 1546 1546 1547 1547 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 1548 1548 1549 -= Create communication with **Modbus RTU** =1549 += Create communication with **Modbus ** = 1550 1550 1551 -== ** V-BOXasSlave** ==1551 +== **MODBUS RTU Slave (All function)** == 1552 1552 1553 1553 Select the protocol "Modbus RTU Slave (All Fuction)", 1554 1554 ... ... @@ -1557,7 +1557,7 @@ 1557 1557 (% style="text-align:center" %) 1558 1558 [[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]] 1559 1559 1560 -== ** V-BOXasMaster** ==1560 +== **MODBUS RTU Master** == 1561 1561 1562 1562 Select the protocol "Modbus RTU Master", 1563 1563 ... ... @@ -1593,6 +1593,61 @@ 1593 1593 |(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils) 1594 1594 |0F (Write multiple bits) 1595 1595 1596 +== **MODBUS TCP Slave (All function)** == 1597 + 1598 +Supported series: MODBUS TCP controller 1599 + 1600 +V-B0X works as MODBUS TCP MASTER connecting with TCP SLAVE 1601 + 1602 +**1)V-BOX Setting** 1603 + 1604 +|**Items**|**Settings**|**Note** 1605 +|Protocol|MODBUS TCP Slave (All function)| 1606 +|Connection|Ethernet| 1607 +|Port No.|502| 1608 +|PLC station No.|1 1609 + 1610 +**2)Address List** 1611 + 1612 +|**Type**|**Register**|**Function code & Description** 1613 +|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers) 1614 +|06 (write single register: write a binary value to a holding register) 1615 +|10 (write values to multiple addresses ) 1616 +|(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers) 1617 +|06 (write single register: write a binary value to a holding register) 1618 +|10 (write values to multiple addresses ) 1619 +|(% rowspan="3" %)W6|03 (read holding register: read current binary value in one or more holding registers) 1620 +|06 (write single register: write a binary value to a holding register) 1621 +|10 (write values to multiple addresses ) 1622 +|(% rowspan="2" %)W16|03 (read holding register: read current binary value in one or more holding registers) 1623 +|10 (write values to multiple addresses ) 1624 +|(% rowspan="11" %)Bit|(% rowspan="3" %)0|01 (Read coil state) 1625 +|05 (Force a single coil to force the on/off state of a logic coil) 1626 +|0F (Write multiple bits, ie write continuously) 1627 +|(% rowspan="3" %)1|02 (Read the input state) 1628 +|05 (Force a single coil to force the on/off state of a logic coil) 1629 +|0F (Write multiple bits) 1630 +|(% rowspan="3" %)W5|01 (Read coil state to obtain the current state of a set of logic coils) 1631 +|05 (Force a single coil to force the on/off state of a logic coil) 1632 +|0F (Write multiple bits) 1633 +|(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils) 1634 +|0F (Write multiple bits) 1635 + 1636 +**3)Communication Settings** 1637 + 1638 +Configure V-BOX Ethernet IP in Networking Settings 1639 + 1640 +[[image:image-20220902111833-3.png]] 1641 + 1642 + 1643 +Configure PLC Ethernet IP in Communication; 1644 + 1645 +[[image:image-20220902111121-1.png]] 1646 + 1647 +**4)Cable Wiring** 1648 + 1649 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 1650 + 1596 1596 == **communicate with VB inverter** == 1597 1597 1598 1598 [[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20VB%20inverter.zip]]
- image-20220902111121-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +60.9 KB - Content
- image-20220902111754-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +57.6 KB - Content
- image-20220902111833-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +56.1 KB - Content