... ... @@ -182,7 +182,7 @@
182 182  
183 183  MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
184 184  
185 -**1)V-BOX setting**
185 +**1)PLC Settings**
186 186  
187 187  |**Item**|**Settings**|**Note**
188 188  |Protocol|Allen-Bradlley DF1 Advanced|
... ... @@ -436,7 +436,7 @@
436 436  
437 437  Supported Series: Siemens S7-300 series PLC
438 438  
439 -**1)V-BOX setting**
439 +**1)PLC Setting**
440 440  
441 441  |**Items**|**Settings**|**Note**
442 442  |Protocol|Simens S7-300 Ethernet|
... ... @@ -498,7 +498,7 @@
498 498  
499 499  Supported Series: Siemens S7-400, S7-1200 and S7-1500
500 500  
501 -**1)V-BOX setting**
501 +**1)PLC Setting**
502 502  
503 503  |=**Items**|=**Settings**|=**Note**
504 504  |Protocol|Siemens S7-XXX|
... ... @@ -1312,41 +1312,6 @@
1312 1312  
1313 1313  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830160232-3.png?rev=1.1||alt="image-20220830160232-3.png"]]
1314 1314  
1315 -
1316 -= Create communication with **Schneider PLC** =
1317 -
1318 -== **Schneider MODBUS RTU** ==
1319 -
1320 -**1)V-BOX Setting**
1321 -
1322 -|=**Parameters**|=**Recommended**|=**Notes**
1323 -|**Protocol**|(% colspan="1" %)Schneider MODBUS RTU|
1324 -|**Connection**|RS485|
1325 -|**Baud rate**|19200|
1326 -|**Data bit**|8|
1327 -|**Parity**|Even|
1328 -|**Stop bit**|1|
1329 -|**PLC station No.**|1|
1330 -
1331 -**2)Address List**
1332 -
1333 -|=**Bit/Word**|=**Device type**|=**Format**|=**Range**|=**Memo**
1334 -|B|IX|DDDDDo|0 ~~ 655357|Input bit (read only)
1335 -|B|QX|DDDDDo|0 ~~ 655357|Write multiple coils
1336 -|B|MX|DDDDDDo|0 ~~ 9999997|Output register bit (octal)
1337 -|W|MW|DDDDDD|0 ~~ 999999|Output register
1338 -|DW|MD|DDDDDD|0 ~~ 999999|Output register
1339 -
1340 -**3)Configure the communication protocol**
1341 -
1342 -[[image:image-20220902104329-1.png]]
1343 -
1344 -**4)Cable Wiring**
1345 -
1346 -**RS-485 2W **(RJ45 Connector): The following is the view from the soldering point of a connector.
1347 -
1348 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220817154212-1.jpeg?width=554&height=315&rev=1.1||alt="image-20220817154212-1.jpeg" height="315" width="554"]]
1349 -
1350 1350  = Create communication with Inovance** PLC** =
1351 1351  
1352 1352  == **H3U serial protocol** ==
... ... @@ -1546,6 +1546,168 @@
1546 1546  
1547 1547  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1548 1548  
1514 += Create communication with **SHIMADEN PLC**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=44]] =
1515 +
1516 +== **FP23 series protocol**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=45]] ==
1517 +
1518 +Supported series: SHIMADEN FP23 series
1519 +
1520 +**HMI Setting**
1521 +
1522 +|**Items**|**Settings**|**Note**
1523 +|Protocol|SHIMADEN FP23 series|
1524 +|Connection|RS485 (9600, 1, 7, EVEN)|
1525 +|Port No.|None|
1526 +|PLC station No.|0|
1527 +
1528 +**Address List**
1529 +
1530 +|**Device address**|**HMI register**|**Address range**|**Type**
1531 +|0040-0043(HEX)|FP040|100064-200067|Read only
1532 +|0100-010B(HEX)|FP100|100256-200267|Read only
1533 +|0110-0142(HEX)|FP110|100272-200322|Read only
1534 +|0182-0252(HEX)|FP182|100386-200594|Write only
1535 +|0280-0281(HEX)|FP280|100640-200641|Read only
1536 +|0300-030B(HEX)|FP300|100768-200779|Read and write
1537 +|0380-039F(HEX)|FP380|100896-200927|Read and write
1538 +|0400-04D7(HEX)|FP400|101024-201239|Read and write
1539 +|0500-05B0(HEX)|FP500|101280-201456|Read and write
1540 +|0600-0670(HEX)|FP600|101536-201814|Read and write
1541 +|0720-0738(HEX)|FP720|101824-201848|Read and write
1542 +|0800-083F(HEX)|FP800|102048-202111|Read and write
1543 +|0900-0952(HEX)|FP900|102304-202386|Read and write
1544 +| |Ctrl|0-2|
1545 +
1546 +**✎Note:**
1547 +
1548 +* The upper 2 bits of the address of the HMI register are taken as the sub address, and the real address is the last four bits (for example, if the address is 100256, then 10 is the sub address as 1, and 0256 is the real address);
1549 +* The address range in the table is only divided by the start and end addresses, and some of the addresses in the range have no corresponding address in FP23;
1550 +* The Ctrl register is used to store the control group number and BCC check mode.
1551 +
1552 +**Ctrl Register Description**
1553 +
1554 +* The Ctrl register is a special register that does not communicate with the temperature controller. User needs to assign value in the screen according to the settings as in the temperature controller.
1555 +* Ctrl0 indicates the setting of the control character, the valid values are 1, 2, 3 respectively, and the corresponding control group is: STX_ETX_CR , STX_ETX_CR LF and @_:_CR .
1556 +* Ctrl1 indicates the BCC block check mode. The valid value range is 1-4. The corresponding check mode is: 1.ADD, 2.ADD_two's cmp, 3.XOR, 4.None;
1557 +* Ctrl3 reserved
1558 +
1559 +**✎Note:**
1560 +
1561 +After reloading the HMI project or restarting the HMI, HMI will reset the value of ctrl0 and ctrl1 as 1, so user need to set these two values to make it the same as it in the temperature controller, then communication will be normal.
1562 +
1563 +**Cable Wiring**
1564 +
1565 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5e9a81a14106da9e.png?width=392&height=223&rev=1.1||alt="12.PLC Protocol_html_5e9a81a14106da9e.png" height="223" width="392"]]
1566 +
1567 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_1897d92be6948d58.png?width=393&height=223&rev=1.1||alt="12.PLC Protocol_html_1897d92be6948d58.png" height="223" width="393"]]
1568 +
1569 +**✎Note:** COM3 only available in PI8000/PI9000 series.
1570 +
1571 +== **SR90 protocol**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=46]] ==
1572 +
1573 +Supported series: SHIMADEN SR90 series
1574 +
1575 +**HMI Setting**
1576 +
1577 +|**Items**|**Settings**|**Note**
1578 +|Protocol|SHIMADEN SR90 protocol|
1579 +|Connection|RS485 (1200, 1, 7, EVEN)|
1580 +|Port No.|None|
1581 +|PLC station No.|0|
1582 +
1583 +**Address List**
1584 +
1585 +|**Device address**|**HMI register**|**Address range**|**Type**
1586 +|0040-0043 (HEX)|SR040|100064-100067|Read only
1587 +|0100-010A(HEX)|SR0100|100256-100266|Read only
1588 +|0182-018C(HEX)|SR0182|100386-100396|Write only
1589 +|0300-04FE(HEX)|SR0300|100768-101278|Write/read
1590 +|0500-050B(HEX)|SR0500|101280-101291|Write/read
1591 +|0590-0611(HEX)|SR0590|101424-101553|Write/read
1592 +|0701-0709(HEX)|SR0701|101793-101801|Write/read
1593 +| |Ctrl|0-2|~-~-
1594 +
1595 +**✎Note:**
1596 +
1597 +* The upper 2 bits of the address of HMIs are taken as the sub address, and the real address is the last four bits (for example, if the address is 100256, then 10 is the sub address as 1, and 0256 is the real address);
1598 +* The address range in the table is only divided by the start and end addresses, and some of the addresses in the range have no corresponding address in SR90;
1599 +* The Ctrl register is used to store the control group number and BCC check mode. See how to use it below;
1600 +
1601 +**Ctrl Register Description**
1602 +
1603 +* The Ctrl register is a special register that does not communicate with the temperature controller. User needs to assign value in the screen according to the settings as in the temperature controller.
1604 +* Ctrl0 indicates the setting of the control character, the valid values are 1, 2, 3 respectively, and the corresponding control group is: STX_ETX_CR , STX_ETX_CR LF and @_:_CR .
1605 +* Ctrl1 indicates the BCC block check mode. The valid value range is 1-4. The corresponding check mode is: 1.ADD, 2.ADD_two's cmp, 3.XOR, 4.None;
1606 +* Ctrl3 reserved
1607 +
1608 +**✎Note:**
1609 +
1610 +After reloading the HMI project or restarting the HMI, HMI will reset the value of ctrl0 and ctrl1 as 1, so user need to set these two values to make it the same as it in the temperature controller, then communication will be normal.
1611 +
1612 +**Cable Wiring**
1613 +
1614 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5e9a81a14106da9e.png?width=392&height=223&rev=1.1||alt="12.PLC Protocol_html_5e9a81a14106da9e.png" height="223" width="392"]]
1615 +
1616 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_1897d92be6948d58.png?width=393&height=223&rev=1.1||alt="12.PLC Protocol_html_1897d92be6948d58.png" height="223" width="393"]]
1617 +
1618 +**✎Note:** COM3 only available in PI8000/PI9000 series.
1619 +
1620 +== **MR13 series(standard protocol)**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=47]] ==
1621 +
1622 +Supported series: SHIMADEN MR13 series
1623 +
1624 +**HMI Setting**
1625 +
1626 +|**Items**|**Settings**|**Note**
1627 +|Protocol|SHIMADEN standard protocol|
1628 +|Connection|RS485 (1200, 1, 7, EVEN)|
1629 +|Port No.|None|
1630 +|PLC station No.|0|
1631 +
1632 +**Address List**
1633 +
1634 +|**Device address**|**HMI register**|**Address range**|**Type**
1635 +|0100-010B(HEX)|MR100|100256-300267|Read only
1636 +|0111-0126(HEX)|MR111|100273-300294|Read only
1637 +|0184-0192(HEX)|MR184|100388-300402|Write only
1638 +|0280-0282(HEX)|MR280|100640-300642|Read only
1639 +|0300-030B(HEX)|MR300|100768-300779|Read/write
1640 +|0314-0317(HEX)|MR314|100788-300791|Read/write
1641 +|031A(HEX)|MR31A|100794-300794|Read/write
1642 +|0320-0321(HEX)|MR320|100800-300801|Read/write
1643 +|0400-0504(HEX)|MR400|101024-301284|Read/write
1644 +|0506(HEX)|MR506|101286-301286|Read/write
1645 +|0510-0514(HEX)|MR510|101296-301300|Read/write
1646 +|0516-0524(HEX)|MR516|101302-301316|Read/write
1647 +|0526(HEX)|MR526|101318-301318|Read/write
1648 +|0580-08C3(HEX)|MR580|101408-302243|Read/write
1649 +|~-~-|Ctrl|0-2|~-~-
1650 +
1651 +**✎Note:**
1652 +
1653 +* The upper 2 bits of the address of the HMI register are taken as the sub address, and the real address is the last four bits (for example, if the address is 100256, then 10 is the sub address as 1, and 0256 is the real address);
1654 +* The address range in the table is only divided by the start and end addresses, and some of the addresses in the range have no corresponding address in MR13;
1655 +* The Ctrl register is used to store the control group number and BCC check mode.
1656 +
1657 +**Ctrl Register Description**
1658 +
1659 +* The Ctrl register is a special register that does not communicate with the temperature controller. User needs to assign value in the screen according to the settings as in the temperature controller.
1660 +* Ctrl0 indicates the setting of the control character, the valid values are 1, 2, 3 respectively, and the corresponding control group is: STX_ETX_CR, STX_ETX_CR LF and @_:_CR .
1661 +* Ctrl1 indicates the BCC block check mode. The valid value range is 1-4. The corresponding check mode is: 1.ADD, 2.ADD_two's cmp, 3.XOR, 4.None;
1662 +* Ctrl3 reserved
1663 +
1664 +**✎Note:**
1665 +
1666 +After reloading project or restarting the HMI, HMI will reset the value of ctrl0 and ctrl1 as 1, so user need to set these two values to make it the same as it in the temperature controller, then communication will be normal.
1667 +
1668 +**Cable Wiring**
1669 +
1670 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5e9a81a14106da9e.png?width=392&height=223&rev=1.1||alt="12.PLC Protocol_html_5e9a81a14106da9e.png" height="223" width="392"]]
1671 +
1672 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_1897d92be6948d58.png?width=393&height=223&rev=1.1||alt="12.PLC Protocol_html_1897d92be6948d58.png" height="223" width="393"]]
1673 +
1674 +**✎Note:** COM3 only available in PI8000/PI9000 series.
1675 +
1549 1549  = Create communication with **Modbus RTU** =
1550 1550  
1551 1551  == **V-BOX as Slave** ==
... ... @@ -1597,67 +1597,6 @@
1597 1597  
1598 1598  [[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20VB%20inverter.zip]]
1599 1599  
1600 -
1601 -== **MODBUS TCP Slave (All function)** ==
1602 -
1603 -Supported series: MODBUS TCP controller
1604 -
1605 -HMI works as MODBUS TCP MASTER connecting with TCP SLAVE
1606 -
1607 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8877cb7f39c2b607.png?width=544&height=571&rev=1.1||alt="12.PLC Protocol_html_8877cb7f39c2b607.png" height="571" width="544"]]
1608 -
1609 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_e7e1f06f127a9175.png?width=553&height=426&rev=1.1||alt="12.PLC Protocol_html_e7e1f06f127a9175.png" height="426" width="553"]]
1610 -
1611 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_60bbfe5de79417a6.png?width=553&height=163&rev=1.1||alt="12.PLC Protocol_html_60bbfe5de79417a6.png" height="163" width="553"]]
1612 -
1613 -**HMI Setting**
1614 -
1615 -|**Items**|**Settings**|**Note**
1616 -|Protocol|MODBUS TCP Slave (All function)|
1617 -|Connection|Ethernet|
1618 -|Port No.|502|
1619 -|PLC station No.|1|
1620 -
1621 -**Address List**
1622 -
1623 -|**Type**|**Register**|**Function code & Description**
1624 -|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers)
1625 -|06 (write single register: write a binary value to a holding register)
1626 -|10 (write values to multiple addresses )
1627 -|(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers)
1628 -|06 (write single register: write a binary value to a holding register)
1629 -|10 (write values to multiple addresses )
1630 -|(% rowspan="3" %)W6|03 (read holding register: read current binary value in one or more holding registers)
1631 -|06 (write single register: write a binary value to a holding register)
1632 -|10 (write values to multiple addresses )
1633 -|(% rowspan="2" %)W16|03 (read holding register: read current binary value in one or more holding registers)
1634 -|10 (write values to multiple addresses )
1635 -|(% rowspan="11" %)Bit|(% rowspan="3" %)0|01 (Read coil state)
1636 -|05 (Force a single coil to force the on/off state of a logic coil)
1637 -|0F (Write multiple bits, ie write continuously)
1638 -|(% rowspan="3" %)1|02 (Read the input state)
1639 -|05 (Force a single coil to force the on/off state of a logic coil)
1640 -|0F (Write multiple bits)
1641 -|(% rowspan="3" %)W5|01 (Read coil state to obtain the current state of a set of logic coils)
1642 -|05 (Force a single coil to force the on/off state of a logic coil)
1643 -|0F (Write multiple bits)
1644 -|(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils)
1645 -|0F (Write multiple bits)
1646 -
1647 -**Communication Settings**
1648 -
1649 -Enable HMI Ethernet in [Project Settings];
1650 -
1651 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_43b671f18153910d.png?width=405&height=107&rev=1.1||alt="12.PLC Protocol_html_43b671f18153910d.png" height="107" width="405"]]
1652 -
1653 -Set PLC IP in [Device IP] settings;
1654 -
1655 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_4bd3cc8348adecf8.png?width=554&height=190&rev=1.1||alt="12.PLC Protocol_html_4bd3cc8348adecf8.png" height="190" width="554"]]
1656 -
1657 -**Cable Wiring**
1658 -
1659 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1660 -
1661 1661  = **User define protocol** =
1662 1662  
1663 1663  More serial port script instruction,please refer manual:[[Lua script function>>doc:V-BOX.V-Net.Manual.04 Lua Script.01 Lua Functions.WebHome]]~-~-->[[3.Serial port operation>>url:http://docs.we-con.com.cn/wiki/vbox/view/HMI/04.Lua%20script%20%20function%20and%20operation/01.Lua%20script%20function/#H3.Serialportoperation]]
image-20220902104329-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -58.7 KB
Content