... ... @@ -1321,7 +1321,7 @@
1321 1321  
1322 1322  |=**Parameters**|=**Recommended**|=**Notes**
1323 1323  |**Protocol**|(% colspan="1" %)Schneider MODBUS RTU|
1324 -|**Connection**|RS485|
1324 +|Connection|RS485|
1325 1325  |**Baud rate**|19200|
1326 1326  |**Data bit**|8|
1327 1327  |**Parity**|Even|
... ... @@ -1328,8 +1328,12 @@
1328 1328  |**Stop bit**|1|
1329 1329  |**PLC station No.**|1|
1330 1330  
1331 -**2)Address List**
1331 +**PLC Setting**
1332 1332  
1333 +|=**Communication mode**|Modbus RTU protocol
1334 +
1335 +**2)Device Address**
1336 +
1333 1333  |=**Bit/Word**|=**Device type**|=**Format**|=**Range**|=**Memo**
1334 1334  |B|IX|DDDDDo|0 ~~ 655357|Input bit (read only)
1335 1335  |B|QX|DDDDDo|0 ~~ 655357|Write multiple coils
... ... @@ -1339,7 +1339,6 @@
1339 1339  
1340 1340  **3)Configure the communication protocol**
1341 1341  
1342 -[[image:image-20220902104329-1.png]]
1343 1343  
1344 1344  **4)Cable Wiring**
1345 1345  
... ... @@ -1546,9 +1546,9 @@
1546 1546  
1547 1547  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1548 1548  
1549 -= Create communication with **Modbus ** =
1552 += Create communication with **Modbus RTU** =
1550 1550  
1551 -== **MODBUS RTU Slave (All function)** ==
1554 +== **V-BOX as Slave** ==
1552 1552  
1553 1553  Select the protocol "Modbus RTU Slave (All Fuction)",
1554 1554  
... ... @@ -1557,7 +1557,7 @@
1557 1557  (% style="text-align:center" %)
1558 1558  [[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]]
1559 1559  
1560 -== **MODBUS RTU Master** ==
1563 +== **V-BOX as Master** ==
1561 1561  
1562 1562  Select the protocol "Modbus RTU Master",
1563 1563  
... ... @@ -1593,67 +1593,6 @@
1593 1593  |(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils)
1594 1594  |0F (Write multiple bits)
1595 1595  
1596 -== **MODBUS TCP Slave (All function)** ==
1597 -
1598 -Supported series: MODBUS TCP controller
1599 -
1600 -HMI works as MODBUS TCP MASTER connecting with TCP SLAVE
1601 -
1602 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8877cb7f39c2b607.png?width=544&height=571&rev=1.1||alt="12.PLC Protocol_html_8877cb7f39c2b607.png" height="571" width="544"]]
1603 -
1604 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_e7e1f06f127a9175.png?width=553&height=426&rev=1.1||alt="12.PLC Protocol_html_e7e1f06f127a9175.png" height="426" width="553"]]
1605 -
1606 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_60bbfe5de79417a6.png?width=553&height=163&rev=1.1||alt="12.PLC Protocol_html_60bbfe5de79417a6.png" height="163" width="553"]]
1607 -
1608 -**HMI Setting**
1609 -
1610 -|**Items**|**Settings**|**Note**
1611 -|Protocol|MODBUS TCP Slave (All function)|
1612 -|Connection|Ethernet|
1613 -|Port No.|502|
1614 -|PLC station No.|1|
1615 -
1616 -**Address List**
1617 -
1618 -|**Type**|**Register**|**Function code & Description**
1619 -|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers)
1620 -|06 (write single register: write a binary value to a holding register)
1621 -|10 (write values to multiple addresses )
1622 -|(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers)
1623 -|06 (write single register: write a binary value to a holding register)
1624 -|10 (write values to multiple addresses )
1625 -|(% rowspan="3" %)W6|03 (read holding register: read current binary value in one or more holding registers)
1626 -|06 (write single register: write a binary value to a holding register)
1627 -|10 (write values to multiple addresses )
1628 -|(% rowspan="2" %)W16|03 (read holding register: read current binary value in one or more holding registers)
1629 -|10 (write values to multiple addresses )
1630 -|(% rowspan="11" %)Bit|(% rowspan="3" %)0|01 (Read coil state)
1631 -|05 (Force a single coil to force the on/off state of a logic coil)
1632 -|0F (Write multiple bits, ie write continuously)
1633 -|(% rowspan="3" %)1|02 (Read the input state)
1634 -|05 (Force a single coil to force the on/off state of a logic coil)
1635 -|0F (Write multiple bits)
1636 -|(% rowspan="3" %)W5|01 (Read coil state to obtain the current state of a set of logic coils)
1637 -|05 (Force a single coil to force the on/off state of a logic coil)
1638 -|0F (Write multiple bits)
1639 -|(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils)
1640 -|0F (Write multiple bits)
1641 -
1642 -**Communication Settings**
1643 -
1644 -Enable HMI Ethernet in [Project Settings];
1645 -
1646 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_43b671f18153910d.png?width=405&height=107&rev=1.1||alt="12.PLC Protocol_html_43b671f18153910d.png" height="107" width="405"]]
1647 -
1648 -Set PLC IP in [Device IP] settings;
1649 -
1650 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_4bd3cc8348adecf8.png?width=554&height=190&rev=1.1||alt="12.PLC Protocol_html_4bd3cc8348adecf8.png" height="190" width="554"]]
1651 -
1652 -**Cable Wiring**
1653 -
1654 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1655 -
1656 -
1657 1657  == **communicate with VB inverter** ==
1658 1658  
1659 1659  [[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20VB%20inverter.zip]]
image-20220902104329-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -58.7 KB