Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
From version 164.1
edited by Ben
on 2022/09/02 11:24
on 2022/09/02 11:24
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki.B en1 +XWiki.Bob - Content
-
... ... @@ -704,6 +704,98 @@ 704 704 [[image:image-20220825100845-4.png]] 705 705 706 706 707 +== ** FX3U Ethernet Protocol** == 708 + 709 +Mitsubishi FX3U series PLC 710 + 711 +**HMI Settings** 712 + 713 +|Items|Settings|Note 714 +|Protocol|Mitsubishi FX3U| 715 +|Connection|Ethernet| 716 +|Port No.|5009|Must be the same as the PLC setting 717 +|PLC station No.|0| 718 + 719 +**Address List** 720 + 721 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 722 +|(% colspan="1" rowspan="7" %)Bit|X|X|X OOO|0~~377| 723 +|Y|Y|Y OOO|0~~377| 724 +|M|M|M DDDD|0~~7679| 725 +|SM|SM|SM DDDD|8000~~8511| 726 +|S|S|S DDDD|0~~4095| 727 +|TS|TS|TS DDD|0~~511| 728 +|CS|CS|CS DDD|0~~255| 729 +|(% colspan="1" rowspan="9" %)Word|CN|CN|CN DDD|0~~199| 730 +|TN|TN|TN DDD|0~~511| 731 +|D|D|D DDDD|0~~7999| 732 +|SD|SD|SD DDDD|8000~~8511| 733 +|R|R|R DDDDD|0~~32767| 734 + 735 +**Ethernet Module Settings** 736 + 737 +FX3U-ENET-L module configuration 738 +Set up the FX3U-ENET-L Ethernet module settings as follows. 739 +Select the module location, which in this document is Module 0. 740 + 741 +[[image:image-20221115140802-1.png]] 742 + 743 +Select "Operational setting" to enter the following screen. 744 + 745 +The Ethernet module IP is set to 192.168.39.254 in this document, and other options are default. 746 + 747 +[[image:image-20221115142728-4.png]] 748 + 749 +Select "Open setting" to enter the setting interface, the settings are as follows. 750 + 751 +The third item "Protocol" selects TCP, and "Open system" selects MELSOFT connection, which allows the 752 + 753 +Mitsubishi programming software GX works2 to communicate with the FX3U via the Ethernet module. 754 + 755 +[[image:image-20221115142945-5.png]] 756 + 757 +Click on "transter setup" - "PC side I/F setting", see the following figure. 758 + 759 +After setting, the first download must use the programming cable, as shown in the figure; after that, can 760 + 761 +use the IP set in the "Ethernet board" to communicate directly with the network cable. 762 + 763 +[[image:image-20221115143341-6.png||height="426" width="712"]] 764 + 765 +Read and write data from the Ethernet module 766 + 767 +[[image:image-20221115143703-7.png]] 768 + 769 +Set "Transter setup" to COM communication, and read or write operation as shown below 770 + 771 +[[image:image-20221115143809-8.png]] 772 + 773 +**PLC Settings (GX Works 2)** 774 + 775 +Create a blank FX5U project 776 + 777 +Find Current Connection in the navigation 778 + 779 +[[image:image-20221115144335-9.png||height="422" width="706"]] 780 + 781 +Select Connection Channel List 782 + 783 +Select Ethernet board communication 784 + 785 +[[image:image-20221115144824-10.png||height="421" width="705"]] 786 + 787 +Select Ethernet Module 788 +Set the IP address of the PLC 789 + 790 +[[image:image-20221115145228-11.png||height="674" width="708"]] 791 + 792 +Read or write PLC data, in this document is read 793 + 794 +[[image:image-20221115145553-12.png||height="424" width="711"]] 795 + 796 +[[image:image-20221115145559-13.png||height="424" width="711"]] 797 + 798 + 707 707 == **FX5U Serial Protocol** == 708 708 709 709 Mitsubishi FX5U series PLC