Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
From version 164.1
edited by Ben
on 2022/09/02 11:24
on 2022/09/02 11:24
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki.B en1 +XWiki.Bob - Content
-
... ... @@ -704,6 +704,101 @@ 704 704 [[image:image-20220825100845-4.png]] 705 705 706 706 707 +== **FX3U Ethernet Protocol** == 708 + 709 + Mitsubishi FX3U series PLC 710 + 711 +**HMI Settings** 712 + 713 +|Items|Settings|Note 714 +|Protocol|Mitsubishi FX3U| 715 +|Connection|Ethernet| 716 +|Port No.|5009|Must be the same as the PLC setting 717 +|PLC station No.|0| 718 + 719 +**Address List** 720 + 721 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 722 +|(% colspan="1" rowspan="7" %)Bit|X|X|X OOO|0~~377| 723 +|Y|Y|Y OOO|0~~377| 724 +|M|M|M DDDD|0~~7679| 725 +|SM|SM|SM DDDD|8000~~8511| 726 +|S|S|S DDDD|0~~4095| 727 +|TS|TS|TS DDD|0~~511| 728 +|CS|CS|CS DDD|0~~255| 729 +|(% colspan="1" rowspan="9" %)Word|CN|CN|CN DDD|0~~199| 730 +|TN|TN|TN DDD|0~~511| 731 +|D|D|D DDDD|0~~7999| 732 +|SD|SD|SD DDDD|8000~~8511| 733 +|R|R|R DDDDD|0~~32767| 734 + 735 +**1)Ethernet Module Settings** 736 + 737 +FX3U-ENET-L module configuration 738 +Set up the FX3U-ENET-L Ethernet module settings as follows. 739 +Select the module location, which in this document is Module 0. 740 + 741 +[[image:image-20221116105850-1.png]] 742 + 743 +Select "Operational setting" to enter the following screen. 744 + 745 +The Ethernet module IP is set to 192.168.39.254 in this document, and other options are default. 746 + 747 +[[image:image-20221116105947-1.png]] 748 + 749 + 750 +Select "Open setting" to enter the setting interface, the settings are as follows. 751 + 752 +The third item "Protocol" selects TCP, and "Open system" selects MELSOFT connection, which allows the 753 + 754 +Mitsubishi programming software GX works2 to communicate with the FX3U via the Ethernet module. 755 + 756 + 757 + 758 +Click on "transter setup" - "PC side I/F setting", see the following figure. 759 + 760 +After setting, the first download must use the programming cable, as shown in the figure; after that, can 761 + 762 +use the IP set in the "Ethernet board" to communicate directly with the network cable. 763 + 764 + 765 + 766 +Read and write data from the Ethernet module 767 + 768 + 769 + 770 +Set "Transter setup" to COM communication, and read or write operation as shown below 771 + 772 + 773 + 774 +**PLC Settings (GX Works 2)** 775 + 776 +Create a blank FX5U project 777 + 778 +Find Current Connection in the navigation 779 + 780 + 781 + 782 +Select Connection Channel List 783 + 784 +Select Ethernet board communication 785 + 786 + 787 + 788 +Select Ethernet Module 789 +Set the IP address of the PLC 790 + 791 + 792 + 793 +Read or write PLC data, in this document is read 794 + 795 + 796 + 797 +**V-BOX Communication Setting** 798 + 799 + 800 + 801 + 707 707 == **FX5U Serial Protocol** == 708 708 709 709 Mitsubishi FX5U series PLC ... ... @@ -858,11 +858,10 @@ 858 858 859 859 [[image:image-20220825112403-1.png||alt="图片-20220825112403-1.png"]] 860 860 861 -**5) 电缆布线**956 +**5)Cable Wiring** 862 862 863 863 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 864 864 865 - 866 866 == **L02 Serial Protocol** == 867 867 868 868 Mitsubishi L02 series CPU built-in serial port.
- image-20221116105850-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bob - Size
-
... ... @@ -1,0 +1,1 @@ 1 +18.9 KB - Content
- image-20221116105947-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bob - Size
-
... ... @@ -1,0 +1,1 @@ 1 +18.7 KB - Content