Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
From version 164.1
edited by Ben
on 2022/09/02 11:24
on 2022/09/02 11:24
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 33 added, 0 removed)
- 0Il1q9GZgk.png
- AB.gif
- ABRS232.gif
- CrouzetRS232 VBox.png
- DVPEthernetAutoSearch.png
- DVPEthernetPLCtoPC.png
- DVPEthernetSetup.png
- DVPEthernetTransfer.png
- DVPEthernetVNETPortocol.png
- DVPEthernetWPLSoft.png
- DVPEthernetWPLSoft2.png
- Delta DVP PROTOCOLSerial232.png
- LldwDGntf4.png
- WgvjfWbQif.png
- image-20221116105850-1.png
- image-20221116105947-1.png
- image-20221116110802-1.png
- image-20221116110832-2.png
- image-20221116110907-3.png
- image-20221116110917-4.png
- image-20221116111427-1.png
- image-20221116111451-2.png
- image-20221116111509-3.png
- image-20221116111651-4.png
- image-20221116111727-5.png
- image-20221116114106-1.png
- image-20221119101759-1.png
- image-20221119101946-2.png
- image-20221119171318-1.png
- image-20221119171343-2.png
- image-20221119171436-3.png
- image-20221119171611-4.png
- image-20221119171832-5.png
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Ben1 +XWiki.Hunter - Content
-
... ... @@ -176,16 +176,116 @@ 176 176 177 177 The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC. 178 178 179 -= Create communication with **Rockwell 179 += Create communication with Allen-Bradley(**Rockwell**)** PLC** = 180 180 181 -== (% id="cke_bm_5621S"style="display:none"%)** **(%%)**MicroLogixProtocol** ==181 +== **DF1 Advanced Protocol** == 182 182 183 +MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05; PLC-5 184 + 185 +**1) V-Box Settings** 186 + 187 +|=Item|=Recommended |=Note 188 +|=Protocol|Allen Bradley DF1 Advanced| 189 +|=Connection|RS232| 190 +|=Baud rate|19200| 191 +|=Stop bits|1| 192 +|=Data bits|8| 193 +|=Parity|None| 194 +|=PLC Station No.|1| 195 +|=HMI Station No.|0| 196 + 197 +**2) Address List** 198 + 199 +|=**Type**|=**Device registers**|=**Format**|=**Range**|=Note 200 +|(% colspan="1" rowspan="7" %)Bit|I1|I1ddd.dd|0.0~~255.15|Only able to communicate with file number I1 201 +|O0|O0ddd.dd|0.0~~255.15|Only able to communicate with file number O0 202 +|S2|S2ddd.dd|0.0~~255.15|Only able to communicate with file number S2 203 +|B3|B3ddd.dd|0.0~~255.15|Only able to communicate with file number B3 204 +|BN|BNddddd.dd|0.0~~99255.15|((( 205 +Bit data file B0~~B99 206 + 207 +First two digits is for file number 208 + 209 +For example, BN13001.00 represents file number B13, address 001, the 0th bit. 210 +))) 211 +|N7|N7ddd.dd|0.0~~255.15|Only able to communicate with file number N7 212 +|NN|NNddddd.dd|0.0~~99255.15|((( 213 +Integer data file bit format N0~~N99 214 + 215 +First two digits is for file number 216 + 217 +For example, NN13001.00 represents file number N13, address 001, the 0th bit. 218 +))) 219 +|(% rowspan="11" %)Word|S2|S2ddd|0~~255|Only able to communicate with file number S2 220 +|T4S|T4Sddd|0~~255|Only able to communicate with file number T4 (Timer Preset Value) 221 +|T4P|T4Pddd|0~~255|Only able to communicate with file number T4 (Timer Accumulator Value) 222 +|TNS|TNSddddd|0~~99255|((( 223 +Timer Preset Value 224 + 225 +First two digits is for file number 226 + 227 +For example, TNS99255 represents file number T99, address 255. 228 +))) 229 +|TNP|TNPddddd|0~~99255|((( 230 +Timer Accumulator Value 231 + 232 +First two digits is for file number 233 + 234 +For example, TNP99255 represents file number T99, address 255. 235 +))) 236 +|C5S|C5Sddd|0~~255|Only able to communicate with file number C5 (Counter Preset Value) 237 +|C5P|C5Pddd|0~~255|Only able to communicate with file number C5 (Counter Accumulator Value) 238 +|CNS|CNSddddd|0~~99255|((( 239 +Counter Preset Value 240 + 241 +First two digits is for file number 242 + 243 +For example, CNS99255 represents file number C99, address 255. 244 +))) 245 +|CNP|CNPddddd|0~~99255|((( 246 +Counter Accumulator Value 247 + 248 +First two digits is for file number 249 + 250 +For example, CNP99255 represents file number C99, address 255. 251 +))) 252 +|N7|N7ddd|0~~255|Only able to communicate with file number N7 253 +|NN|NNddd|0~~99255|((( 254 +Integer data file 255 + 256 +First two digits is for file number 257 + 258 +For example, NN99255 represents file number N99, address 255. 259 +))) 260 +|(% colspan="1" rowspan="3" %)Double Word|F8|F8ddd|0~~255|((( 261 +Only able to communicate with file number N7 262 +))) 263 +|FN|FNddddd|0~~99255|((( 264 +Floating point data file 265 + 266 +First two digits is for file number 267 + 268 +For example, FN99255 represents file number F99, address 255. 269 +))) 270 +|LN|LNddddd|0~~99255|Long 271 + 272 +**3) Cable Wiring** 273 + 274 +(% style="text-align:center" %) 275 +[[image:ABRS232.gif]] 276 + 277 +(% class="wikigeneratedid" id="HMicroLogixA0Protocol" %) 278 +(% id="cke_bm_5621S" style="display:none" %)** ** 279 + 280 +== **MicroLogix Protocol** == 281 + 282 +(% class="wikigeneratedid" %) 183 183 MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 184 184 185 185 **1)V-BOX setting** 186 186 187 187 |**Item**|**Settings**|**Note** 188 -|Protocol|Allen-Bradl ley DF1 Advanced|288 +|Protocol|Allen-Bradley DF1 Advanced| 189 189 |Connection|RS232| 190 190 |Baud rate|19200| 191 191 |Data bit|8| ... ... @@ -419,12 +419,64 @@ 419 419 ((( 420 420 The above are all the steps for establishing Ethernet communication between Wecon V-box with CompactLogix L1769 PLC. 421 421 522 +== **Ethernet DF1 Protocol** == 422 422 423 -== **Allen-Bradley Ethernet DF1** == 424 - 425 425 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]] 426 426 526 += Create communication with **Crouzet PLC** = 427 427 528 +== **CROUZET M3 (FBD)** == 529 + 530 +Support Series: Crouzet Millenium 3 CD12/CB12 531 + 532 +**1)V-BOX setting** 533 + 534 +|=Item|=Recommended |=Note 535 +|=Protocol|CROUZET M3 (FBD)| 536 +|=Connection|RS232| 537 +|=Baud rate|115200| 538 +|=Stop bits|1| 539 +|=Data bits|7| 540 +|=Parity|EVEN| 541 + 542 +**2)Address List** 543 + 544 +|=**Type**|=**Device registers**|=**Format**|=**Range**|=Note 545 +|(% rowspan="4" %)Bit|I|I DD|1~~99|Input 546 +|SLIBit|SLIBit DD.dd|1.0~~24.15|Serial Link Input 547 +|SLOBit|SLOBit DD.dd|25.0~~48.15|Serial Link Output(Read only) 548 +|State|State D|1~~1|PLC state(Read only) 549 +|(% rowspan="5" %)Word|AI|AI DD|1~~99|Analog Input 550 +|SLIn|SLIn DD|1~~24|Serial Link Input 551 +|SLOut|SLOut DD|25~~48|Serial Link Output(Read only) 552 +|Time|Time D|1~~6|((( 553 +Time1: Second 554 + 555 +Time2: Minute 556 + 557 +Time3: Hour 558 + 559 +Time4: Day 560 + 561 +Time5: Month 562 + 563 +Time6: Year 564 +))) 565 +|Order|Order D|1~~1|((( 566 +Running command(Write only) 567 + 568 +~=2: Run mode; =1: Stop mode; 569 +))) 570 + 571 +**3)Cable Wiring** 572 + 573 +(% style="text-align:center" %) 574 +[[image:CrouzetRS232 VBox.png]] 575 + 576 +{{info}} 577 +**✎Note: **As the wiring diagram indicated, this protocol requires the DB9 serial port pin 4. But pin 4 is undefined for all V-Box, so it need the user to solder a Pull-up resistor to make the pin 4 working. As for how to solder the resistor on the motherboard, please contact with Wecon technical support for the details. 578 +{{/info}} 579 + 428 428 = Create communication with **Siemens PLC** = 429 429 430 430 == **S7-200 Smart Ethernet Protocol** == ... ... @@ -608,6 +608,97 @@ 608 608 609 609 [[image:image-20220824162342-2.png]] 610 610 763 +== **LOGO Ethernet Protocol** == 764 + 765 +Supported Series: Siemens Logo 0BA0, 0BA1 series 766 + 767 +**V-BOX Settings** 768 + 769 + 770 +|**Items**|**Settings**|**Note** 771 +|Protocol|Siemens LOGO| 772 +|Connection|Ethernet| 773 +|Port No.|102| 774 +|PLC station No.|2| 775 + 776 +**Address List** 777 + 778 + 779 +|**Number**|**Address Type**|**Data Type**|**Range**|**DB Address**|**PLC Address** 780 +|1|RTC|Word|1-7|DB1.DBX984.0|0x001ec0 781 +|2|VB|Byte|0-1469|DB1.DBX0.0|0x000000 782 +|3|VD|Double Word|0-1466|DB1.DBX0.0|0x000000 783 +|4|VW|Word|0-1468|DB1.DBX0.0|0x000000 784 +|5|NAQ|Word|1-32|DB1.DBX1406.0|0x002bf0 785 +|6|NAI|Word|1-64|DB1.DBX1262.0|0x002770 786 +|7|AM|Word|1-64|DB1.DBX1118.0|0x0022f0 787 +|8|AQ|Word|1-16|DB1.DBX1072.0|0x002180 788 +|9|AI|Word|1-16|DB1.DBX1032.0|0x002040 789 +|10|I|Bit|1-64|DB1.DBX1024.0|0x002000 790 +|11|Q|Bit|1-64|DB1.DBX1064.0|0x002140 791 +|12|M|Bit|1-112|DB1.DBX1104.0|0x002280 792 +|13|NI|Bit|1-128|DB1.DBX1246.0|0x0026f0 793 +|14|NQ|Bit|1-128|DB1.DBX1390.0|0x002b70 794 +|15|V|Bit|0-14697|DB1.DBX0.0|0x000000 795 + 796 +**PLC Settings in LOGO Software:** 797 + 798 +Click [Tools]~-~-[Ethernet Connections],shown as below. 799 + 800 +(% style="text-align:center" %) 801 +[[image:PIStudio.12\.PLC protocols.WebHome@12.PLC Protocol_html_8b9d2322edf89519.png]] 802 + 803 +Set Ethernet connection parameter. IP, Subnet Mask, shown as below. 804 + 805 +(% style="text-align:center" %) 806 +[[image:PIStudio.12\.PLC protocols.WebHome@image-20221228142937-4.png]] 807 + 808 +**TSAP set**:The value set by local TSAP is the remote TSAP set in HMI. PLC's remote TSAP is the opposite,shown as below. 809 + 810 +(% style="text-align:center" %) 811 +[[image:PIStudio.12\.PLC protocols.WebHome@image-20221228143047-5.png]] 812 + 813 + **Download Project**: Click "Address book" to add the IP address to be downloaded (fi."Detect" to check whether the IP address can be detected. Then click “ok”, and the system will prompt that PLC will be "STOP" mode. Click “YES” to start download. 814 + 815 +(% style="text-align:center" %) 816 +[[image:PIStudio.12\.PLC protocols.WebHome@image-20221228143246-6.png]] 817 + 818 +**V-BOX Communication Settings** 819 + 820 +Set PLC IP in [IP Address] settings; 821 + 822 +(% style="text-align:center" %) 823 +[[image:LldwDGntf4.png]] 824 + 825 +Enable V-BOX Ethernet in [Network]; 826 + 827 +(% style="text-align:center" %) 828 +[[image:WgvjfWbQif.png]] 829 + 830 +TSAP setting 831 + 832 +* The initialization script needs to set the source TSAP address and the target TSAP address, otherwise the communication will not be successful. 833 + 834 +{{code language="LUA"}} 835 +function init.main() 836 +addr_setword("@W_0#HSW1200",8192) -- Set the source TSAP address 837 +addr_setword("@W_0#HSW1201",4096) -- Set the destination TSAP address 838 +end 839 +{{/code}} 840 + 841 +Note: The name of the test script is init, 8192 and 4096 are the data used for the test, there is no HSW address in the register option, but you can directly set the value of the corresponding address through the code. 842 + 843 +**✎Note:** 844 + 845 +* **Communication port configuration: ** 846 +** Continuous length needs to be set to 0. 847 +** Integration interval needs to be set to 1. (no change may result in data errors) 848 +** Set Port and Device Station NO. 849 +** Other set as defaulted. 850 +* **Notes on the use of registers:** 851 +** Register VD: Use only registers that are multiples of 4, such as 0, 4, 8, etc. 852 +** Register VW: Use only registers thay are multiples of 2, such as 0, 2, 4 etc. (Using an odd-length register may result in data errors, such as 2 3 4 ) 853 + 611 611 = Create communication with **Mitsubishi PLC** = 612 612 613 613 == **FX1S,1N,2N Serial Protocol** == ... ... @@ -704,6 +704,101 @@ 704 704 [[image:image-20220825100845-4.png]] 705 705 706 706 950 +== **FX3U Ethernet Protocol** == 951 + 952 +Supported Modules: FX3U-ENET-ADP, FX3U-ENET-L 953 + 954 +**1)V-BOX Settings** 955 + 956 +|Items|Settings|Note 957 +|Protocol|Mitsubishi FX3U| 958 +|Connection|Ethernet| 959 +|Port No.|5009|Must be the same as the PLC setting 960 +|PLC station No.|0| 961 + 962 +**2)Address List** 963 + 964 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 965 +|(% colspan="1" rowspan="7" %)Bit|X|X|X OOO|0~~377| 966 +|Y|Y|Y OOO|0~~377| 967 +|M|M|M DDDD|0~~7679| 968 +|SM|SM|SM DDDD|8000~~8511| 969 +|S|S|S DDDD|0~~4095| 970 +|TS|TS|TS DDD|0~~511| 971 +|CS|CS|CS DDD|0~~255| 972 +|(% colspan="1" rowspan="9" %)Word|CN|CN|CN DDD|0~~199| 973 +|TN|TN|TN DDD|0~~511| 974 +|D|D|D DDDD|0~~7999| 975 +|SD|SD|SD DDDD|8000~~8511| 976 +|R|R|R DDDDD|0~~32767| 977 + 978 +**3)Ethernet Module Settings** 979 + 980 +FX3U-ENET-L module configuration 981 +Set up the FX3U-ENET-L Ethernet module settings as follows. 982 +Select the module location, which in this document is Module 0. 983 + 984 +[[image:image-20221116105850-1.png]] 985 + 986 +Select "Operational setting" to enter the following screen. 987 + 988 +The Ethernet module IP is set to 192.168.39.254 in this document, and other options are default. 989 + 990 +[[image:image-20221116105947-1.png]] 991 + 992 +Select "Open setting" to enter the setting interface, the settings are as follows. 993 + 994 +The third item "Protocol" selects TCP, and "Open system" selects MELSOFT connection, which allows the 995 + 996 +Mitsubishi programming software GX works2 to communicate with the FX3U via the Ethernet module. 997 + 998 +[[image:image-20221116110802-1.png]] 999 + 1000 +Click on "transter setup" - "PC side I/F setting", see the following figure. 1001 + 1002 +After setting, the first download must use the programming cable, as shown in the figure; after that, can 1003 + 1004 +use the IP set in the "Ethernet board" to communicate directly with the network cable. 1005 + 1006 +[[image:image-20221116110832-2.png||height="423" width="708"]] 1007 + 1008 +Read and write data from the Ethernet module 1009 + 1010 +[[image:image-20221116110907-3.png]] 1011 + 1012 +Set "Transter setup" to COM communication, and read or write operation as shown below 1013 + 1014 +[[image:image-20221116110917-4.png]] 1015 + 1016 +**4)PLC Settings (GX Works 2)** 1017 + 1018 +Create a blank FX5U project 1019 + 1020 +Find Current Connection in the navigation 1021 + 1022 +[[image:image-20221116111427-1.png||height="421" width="705"]] 1023 + 1024 +Select Connection Channel List 1025 + 1026 +Select Ethernet board communication 1027 + 1028 +[[image:image-20221116111451-2.png||height="421" width="705"]] 1029 + 1030 +Select Ethernet Module 1031 +Set the IP address of the PLC 1032 + 1033 +[[image:image-20221116111509-3.png||height="666" width="699"]] 1034 + 1035 +Read or write PLC data, in this document is read 1036 + 1037 +[[image:image-20221116111651-4.png||height="416" width="697"]] 1038 + 1039 +[[image:image-20221116111727-5.png||height="416" width="697"]] 1040 + 1041 +**4)Configure the communication protocol** 1042 + 1043 +[[image:image-20221119101946-2.png||height="395" width="695"]] 1044 + 707 707 == **FX5U Serial Protocol** == 708 708 709 709 Mitsubishi FX5U series PLC ... ... @@ -858,11 +858,10 @@ 858 858 859 859 [[image:image-20220825112403-1.png||alt="图片-20220825112403-1.png"]] 860 860 861 -**5) 电缆布线**1199 +**5)Cable Wiring** 862 862 863 863 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 864 864 865 - 866 866 == **L02 Serial Protocol** == 867 867 868 868 Mitsubishi L02 series CPU built-in serial port. ... ... @@ -996,6 +996,12 @@ 996 996 997 997 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 998 998 1336 +== **Q12H Serial Protocol** == 1337 + 1338 +This Demo shows V-BOX communicate with Q12H PLC by Q02H serial Protocol 1339 + 1340 +[[**Download link**>>https://ftp.we-con.com.cn/Download/WIKI/PI%20HMI/Demo/Communication/V-Box%20connect%20PLC%20Q12H.rar]] 1341 + 999 999 == **QJ71E71 Ethernet Protocol** == 1000 1000 1001 1001 Mitsubishi QJ71E71 Ethernet communication module; ... ... @@ -1044,10 +1044,13 @@ 1044 1044 1045 1045 * Click [Ethernet/CC IE/MELSECNET]; 1046 1046 * Please select [Ethernet] as network type; 1047 -* Set station I/O number according to situation (For example, 000 0means that the module is connected to PLC CPU in first order);1390 +* Set station I/O number according to situation (For example, 0020 means that the module is connected to PLC CPU in first order); 1048 1048 * Select [Online] as Mode; 1392 +* [[image:image-20221119171343-2.png||height="341" width="587"]] 1049 1049 * Click [Operation setting] to set IP; 1050 1050 * Select [Binary Code] as [Communication Data Code]; 1395 +* [[image:image-20221119171436-3.png||height="354" width="588"]] 1396 +* Click [Open setting] 1051 1051 * Set protocol: TCP; 1052 1052 * Set [unpassive] in [Open system]; 1053 1053 * Set [receive] in [Fixed buffer]; ... ... @@ -1054,14 +1054,16 @@ 1054 1054 * Set [procedure Exist] in [Fixed buffer communication]; 1055 1055 * Disable [Pairing open]; 1056 1056 * Set [No confirm] in [Existence confirmation]; 1057 -* Host station port number: 1025;1403 +* Host station port number: 5009; 1058 1058 * Save settings; 1405 +* [[image:image-20221119171611-4.png||height="354" width="588"]] 1059 1059 * Download project into PLC and restart it 1060 1060 1061 1061 **4)Configure the communication protocol** 1062 1062 1063 -[[image:image-2022 0825143728-1.png]]1410 +[[image:image-20221119171832-5.png||height="354" width="625"]] 1064 1064 1412 + 1065 1065 **5)Cable Wiring** 1066 1066 1067 1067 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png"]] ... ... @@ -1070,12 +1070,105 @@ 1070 1070 1071 1071 == **DVP Ethernet Protocol** == 1072 1072 1073 - [[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]1421 +Supoort Series: DELTA DVP20/32/40/60ES200RE/200TE or any DVP models with built-in Ethernet port, DELTA DVPEN01-SL module 1074 1074 1423 +**1)V-BOX Settings** 1424 + 1425 +|=**Items**|=**Settings**|=**Note** 1426 +|Protocol|DELTA DVP MODBUS TCP| 1427 +|Connection|Ethernet| 1428 +|Port No.|502| 1429 +|Device No.|1| 1430 +|VBox Device No.|0| 1431 + 1432 +**2)Address List ** 1433 + 1434 +|=**Type**|=(% style="width: 191px;" %)**Device registers**|=(% style="width: 217px;" %)**VBox registers**|=(% style="width: 168px;" %)**Format**|=(% style="width: 225px;" %)**Range**|=**Note** 1435 +|Bit|(% style="width:191px" %)X|(% style="width:217px" %)X|(% style="width:168px" %)X OOO|(% style="width:225px" %)0~~377| 1436 +|Bit|(% style="width:191px" %)Y|(% style="width:217px" %)Y|(% style="width:168px" %)Y OOO|(% style="width:225px" %)0~~377| 1437 +|Bit|(% style="width:191px" %)M0|(% style="width:217px" %)M0|(% style="width:168px" %)M0DDDD|(% style="width:225px" %)0~~1535| 1438 +|Bit|(% style="width:191px" %)M1|(% style="width:217px" %)M1|(% style="width:168px" %)M1DDDD|(% style="width:225px" %)1536~~4096| 1439 +|Bit|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDD|(% style="width:225px" %)0~~255| 1440 +|Bit|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDD|(% style="width:225px" %)0~~255| 1441 +|Bit|(% style="width:191px" %)S|(% style="width:217px" %)S|(% style="width:168px" %)SDDDD|(% style="width:225px" %)0~~1023| 1442 +|Word|(% style="width:191px" %)D0|(% style="width:217px" %)D0|(% style="width:168px" %)D0DDDD|(% style="width:225px" %)0~~4095| 1443 +|Word|(% style="width:191px" %)D1|(% style="width:217px" %)D1|(% style="width:168px" %)D1DDDD|(% style="width:225px" %)4096~~11999| 1444 +|Word|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDD|(% style="width:225px" %)0~~255| 1445 +|Word|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDD|(% style="width:225px" %)0~~199| 1446 +|Double Word|(% style="width:191px" %)HC|(% style="width:217px" %)HC|(% style="width:168px" %)HCDDD|(% style="width:225px" %)200~~255| 1447 + 1448 +**3) PLC Setting:** 1449 + 1450 +~1. Create new project in Delta WPL Soft, and click Setting to open the communication settings: 1451 + 1452 +(% style="text-align:center" %) 1453 +[[image:DVPEthernetWPLSoft2.png]] 1454 + 1455 +2. Set up the communication type and PLC IP: 1456 + 1457 +(% style="text-align:center" %) 1458 +[[image:DVPEthernetSetup.png]] 1459 + 1460 +(% class="wikigeneratedid" %) 1461 +3. Click OK and save the settings. Then click Communication on toolbar, then click Transfer Setup to open new window: 1462 + 1463 +(% style="text-align:center" %) 1464 +[[image:DVPEthernetTransfer.png]] 1465 + 1466 +(% class="wikigeneratedid" %) 1467 +4. Select Communication Mode as PC => PLC to download or select PC <=PLC to upload: 1468 + 1469 +(% style="text-align:center" %) 1470 +[[image:DVPEthernetPLCtoPC.png]] 1471 + 1472 +5. Click Auto-Search Ethernet Module to find the PLC on the same LAN network: 1473 + 1474 +(% style="text-align:center" %) 1475 +[[image:DVPEthernetAutoSearch.png]] 1476 + 1477 +**4) V-BOX Setting:** 1478 + 1479 +Set the same IP address according to the setting from WPL Soft: 1480 + 1481 +(% style="text-align:center" %) 1482 +[[image:DVPEthernetVNETPortocol.png]] 1483 + 1075 1075 == **DVP serial protocol** == 1076 1076 1077 - [[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]1486 +Supoort Series: DELTA DVP EH/ES/SS/EX/EH2/SV/SA/SC/SX 1078 1078 1488 +**1)V-BOX Settings** 1489 + 1490 +|=**Items**|=**Settings**|=**Note** 1491 +|Protocol|DELTA DVP PROTOCOL| 1492 +|Connection|RS232| 1493 +|Baud Rate|9600| 1494 +|Stop Bit|1| 1495 +|Data Bit|7| 1496 +|Parity|EVEN| 1497 +|Device No.|1| 1498 + 1499 +(% class="wikigeneratedid" %) 1500 +**2)Address List** 1501 + 1502 +|=**Type**|=(% style="width: 191px;" %)**Device registers**|=(% style="width: 217px;" %)**VBox registers**|=(% style="width: 168px;" %)**Format**|=(% style="width: 225px;" %)**Range**|=**Note** 1503 +|Bit|(% style="width:191px" %)X|(% style="width:217px" %)X|(% style="width:168px" %)X OOOOOO|(% style="width:225px" %)0~~303237| 1504 +|Bit|(% style="width:191px" %)Y|(% style="width:217px" %)Y|(% style="width:168px" %)Y OOOOOO|(% style="width:225px" %)0~~303237| 1505 +|Bit|(% style="width:191px" %)M|(% style="width:217px" %)M|(% style="width:168px" %)MDDDDD|(% style="width:225px" %)0~~99999| 1506 +|Bit|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDDDD|(% style="width:225px" %)0~~99999| 1507 +|Bit|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDDDD|(% style="width:225px" %)0~~99999| 1508 +|Bit|(% style="width:191px" %)S|(% style="width:217px" %)S|(% style="width:168px" %)SDDDDD|(% style="width:225px" %)0~~99999| 1509 +|Word|(% style="width:191px" %)D|(% style="width:217px" %)D|(% style="width:168px" %)D DDDDD|(% style="width:225px" %)0~~99999| 1510 +|Word|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDDDD|(% style="width:225px" %)0~~99999| 1511 +|Word|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDD|(% style="width:225px" %)0~~199| 1512 +|Double Word|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDDDD|(% style="width:225px" %)200~~99999| 1513 + 1514 +(% class="wikigeneratedid" %) 1515 +**3)Wiring Diagram** 1516 + 1517 +(% style="text-align:center" %) 1518 +[[image:Delta DVP PROTOCOLSerial232.png]] 1519 + 1079 1079 == **AS Ethernet Protocol** == 1080 1080 1081 1081 **1)V-BOX Settings** ... ... @@ -1109,7 +1109,6 @@ 1109 1109 1110 1110 **3)Configure the communication protocol** 1111 1111 1112 - 1113 1113 [[image:image-20220831160010-4.png]] 1114 1114 1115 1115 **4)Cable Wiring** ... ... @@ -1242,7 +1242,7 @@ 1242 1242 1243 1243 **1)V-BOX Settings** 1244 1244 1245 -Supported Series: DeltaXinjie XD/XE Series PLC1685 +Supported Series: Xinjie XD/XE Series PLC 1246 1246 1247 1247 |**Item**|**Settings**|**Note** 1248 1248 |Protocol|XINJE XD/XC MODBUS| ... ... @@ -1312,7 +1312,6 @@ 1312 1312 1313 1313 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830160232-3.png?rev=1.1||alt="image-20220830160232-3.png"]] 1314 1314 1315 - 1316 1316 = Create communication with **Schneider PLC** = 1317 1317 1318 1318 == **Schneider MODBUS RTU** == ... ... @@ -1569,8 +1569,8 @@ 1569 1569 **address list** 1570 1570 1571 1571 (% class="table-bordered" %) 1572 -|** type**|**register**|**Function code and description**1573 -|(% rowspan="11" %) 词|(% rowspan="3" %)3|04 (Read Input Registers: Read the current binary value in one or more input registers)2011 +|=(% scope="row" %)**Type**|=**Data Type**|=**Function code and description** 2012 +|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (Read Input Registers: Read the current binary value in one or more input registers) 1574 1574 |06 (write single register: write a binary value to a holding register) 1575 1575 |10 (write values to multiple addresses ) 1576 1576 |(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers) ... ... @@ -1609,7 +1609,7 @@ 1609 1609 1610 1610 **2)Address List** 1611 1611 1612 -|**Type**|** Register**|**Function code & Description**2051 +|=**Type**|=**Data Type**|=**Function code & Description** 1613 1613 |(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers) 1614 1614 |06 (write single register: write a binary value to a holding register) 1615 1615 |10 (write values to multiple addresses )
- 0Il1q9GZgk.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bob - Size
-
... ... @@ -1,0 +1,1 @@ 1 +24.6 KB - Content
- AB.gif
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +7.3 KB - Content
- ABRS232.gif
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +7.3 KB - Content
- CrouzetRS232 VBox.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +14.9 KB - Content
- DVPEthernetAutoSearch.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +43.6 KB - Content
- DVPEthernetPLCtoPC.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +8.9 KB - Content
- DVPEthernetSetup.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +19.9 KB - Content
- DVPEthernetTransfer.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +59.9 KB - Content
- DVPEthernetVNETPortocol.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +21.4 KB - Content
- DVPEthernetWPLSoft.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +97.5 KB - Content
- DVPEthernetWPLSoft2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +45.2 KB - Content
- Delta DVP PROTOCOLSerial232.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +10.7 KB - Content
- LldwDGntf4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bob - Size
-
... ... @@ -1,0 +1,1 @@ 1 +24.3 KB - Content
- WgvjfWbQif.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bob - Size
-
... ... @@ -1,0 +1,1 @@ 1 +36.3 KB - Content
- image-20221116105850-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bob - Size
-
... ... @@ -1,0 +1,1 @@ 1 +18.9 KB - Content
- image-20221116105947-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bob - Size
-
... ... @@ -1,0 +1,1 @@ 1 +18.7 KB - Content
- image-20221116110802-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bob - Size
-
... ... @@ -1,0 +1,1 @@ 1 +16.4 KB - Content
- image-20221116110832-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bob - Size
-
... ... @@ -1,0 +1,1 @@ 1 +42.2 KB - Content
- image-20221116110907-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bob - Size
-
... ... @@ -1,0 +1,1 @@ 1 +17.8 KB - Content
- image-20221116110917-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bob - Size
-
... ... @@ -1,0 +1,1 @@ 1 +23.2 KB - Content
- image-20221116111427-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bob - Size
-
... ... @@ -1,0 +1,1 @@ 1 +63.4 KB - Content
- image-20221116111451-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bob - Size
-
... ... @@ -1,0 +1,1 @@ 1 +225.5 KB - Content
- image-20221116111509-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bob - Size
-
... ... @@ -1,0 +1,1 @@ 1 +34.1 KB - Content
- image-20221116111651-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bob - Size
-
... ... @@ -1,0 +1,1 @@ 1 +74.3 KB - Content
- image-20221116111727-5.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bob - Size
-
... ... @@ -1,0 +1,1 @@ 1 +106.2 KB - Content
- image-20221116114106-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bob - Size
-
... ... @@ -1,0 +1,1 @@ 1 +99.5 KB - Content
- image-20221119101759-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bob - Size
-
... ... @@ -1,0 +1,1 @@ 1 +62.1 KB - Content
- image-20221119101946-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bob - Size
-
... ... @@ -1,0 +1,1 @@ 1 +68.7 KB - Content
- image-20221119171318-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bob - Size
-
... ... @@ -1,0 +1,1 @@ 1 +90.3 KB - Content
- image-20221119171343-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bob - Size
-
... ... @@ -1,0 +1,1 @@ 1 +90.3 KB - Content
- image-20221119171436-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bob - Size
-
... ... @@ -1,0 +1,1 @@ 1 +43.4 KB - Content
- image-20221119171611-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bob - Size
-
... ... @@ -1,0 +1,1 @@ 1 +23.1 KB - Content
- image-20221119171832-5.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bob - Size
-
... ... @@ -1,0 +1,1 @@ 1 +69.6 KB - Content