Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 3 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki.B ob1 +XWiki.Ben - Content
-
... ... @@ -704,98 +704,6 @@ 704 704 [[image:image-20220825100845-4.png]] 705 705 706 706 707 -== ** FX3U Ethernet Protocol** == 708 - 709 -Mitsubishi FX3U series PLC 710 - 711 -**HMI Settings** 712 - 713 -|Items|Settings|Note 714 -|Protocol|Mitsubishi FX3U| 715 -|Connection|Ethernet| 716 -|Port No.|5009|Must be the same as the PLC setting 717 -|PLC station No.|0| 718 - 719 -**Address List** 720 - 721 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 722 -|(% colspan="1" rowspan="7" %)Bit|X|X|X OOO|0~~377| 723 -|Y|Y|Y OOO|0~~377| 724 -|M|M|M DDDD|0~~7679| 725 -|SM|SM|SM DDDD|8000~~8511| 726 -|S|S|S DDDD|0~~4095| 727 -|TS|TS|TS DDD|0~~511| 728 -|CS|CS|CS DDD|0~~255| 729 -|(% colspan="1" rowspan="9" %)Word|CN|CN|CN DDD|0~~199| 730 -|TN|TN|TN DDD|0~~511| 731 -|D|D|D DDDD|0~~7999| 732 -|SD|SD|SD DDDD|8000~~8511| 733 -|R|R|R DDDDD|0~~32767| 734 - 735 -**Ethernet Module Settings** 736 - 737 -FX3U-ENET-L module configuration 738 -Set up the FX3U-ENET-L Ethernet module settings as follows. 739 -Select the module location, which in this document is Module 0. 740 - 741 -[[image:image-20221115140802-1.png]] 742 - 743 -Select "Operational setting" to enter the following screen. 744 - 745 -The Ethernet module IP is set to 192.168.39.254 in this document, and other options are default. 746 - 747 -[[image:image-20221115142728-4.png]] 748 - 749 -Select "Open setting" to enter the setting interface, the settings are as follows. 750 - 751 -The third item "Protocol" selects TCP, and "Open system" selects MELSOFT connection, which allows the 752 - 753 -Mitsubishi programming software GX works2 to communicate with the FX3U via the Ethernet module. 754 - 755 -[[image:image-20221115142945-5.png]] 756 - 757 -Click on "transter setup" - "PC side I/F setting", see the following figure. 758 - 759 -After setting, the first download must use the programming cable, as shown in the figure; after that, can 760 - 761 -use the IP set in the "Ethernet board" to communicate directly with the network cable. 762 - 763 -[[image:image-20221115143341-6.png||height="426" width="712"]] 764 - 765 -Read and write data from the Ethernet module 766 - 767 -[[image:image-20221115143703-7.png]] 768 - 769 -Set "Transter setup" to COM communication, and read or write operation as shown below 770 - 771 -[[image:image-20221115143809-8.png]] 772 - 773 -**PLC Settings (GX Works 2)** 774 - 775 -Create a blank FX5U project 776 - 777 -Find Current Connection in the navigation 778 - 779 -[[image:image-20221115144335-9.png||height="422" width="706"]] 780 - 781 -Select Connection Channel List 782 - 783 -Select Ethernet board communication 784 - 785 -[[image:image-20221115144824-10.png||height="421" width="705"]] 786 - 787 -Select Ethernet Module 788 -Set the IP address of the PLC 789 - 790 -[[image:image-20221115145228-11.png||height="674" width="708"]] 791 - 792 -Read or write PLC data, in this document is read 793 - 794 -[[image:image-20221115145553-12.png||height="424" width="711"]] 795 - 796 -[[image:image-20221115145559-13.png||height="424" width="711"]] 797 - 798 - 799 799 == **FX5U Serial Protocol** == 800 800 801 801 Mitsubishi FX5U series PLC ... ... @@ -1640,7 +1640,7 @@ 1640 1640 1641 1641 = Create communication with **Modbus ** = 1642 1642 1643 -== **MODBUS RTUSlave (All function)** ==1551 +== **MODBUS TCP Slave (All function)** == 1644 1644 1645 1645 Select the protocol "Modbus RTU Slave (All Fuction)", 1646 1646 ... ... @@ -1689,17 +1689,23 @@ 1689 1689 1690 1690 Supported series: MODBUS TCP controller 1691 1691 1692 - V-B0Xworks as MODBUS TCP MASTER connecting with TCP SLAVE1600 +HMI works as MODBUS TCP MASTER connecting with TCP SLAVE 1693 1693 1694 - **1)V-BOXSetting**1602 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8877cb7f39c2b607.png?width=544&height=571&rev=1.1||alt="12.PLC Protocol_html_8877cb7f39c2b607.png" height="571" width="544"]] 1695 1695 1604 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_e7e1f06f127a9175.png?width=553&height=426&rev=1.1||alt="12.PLC Protocol_html_e7e1f06f127a9175.png" height="426" width="553"]] 1605 + 1606 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_60bbfe5de79417a6.png?width=553&height=163&rev=1.1||alt="12.PLC Protocol_html_60bbfe5de79417a6.png" height="163" width="553"]] 1607 + 1608 +**HMI Setting** 1609 + 1696 1696 |**Items**|**Settings**|**Note** 1697 1697 |Protocol|MODBUS TCP Slave (All function)| 1698 1698 |Connection|Ethernet| 1699 1699 |Port No.|502| 1700 -|PLC station No.|1 1614 +|PLC station No.|1| 1701 1701 1702 -** 2)Address List**1616 +**Address List** 1703 1703 1704 1704 |**Type**|**Register**|**Function code & Description** 1705 1705 |(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers) ... ... @@ -1725,21 +1725,21 @@ 1725 1725 |(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils) 1726 1726 |0F (Write multiple bits) 1727 1727 1728 -** 3)Communication Settings**1642 +**Communication Settings** 1729 1729 1730 - ConfigureV-BOXEthernetIPinNetworkingSettings1644 +Enable HMI Ethernet in [Project Settings]; 1731 1731 1732 -[[image: image-20220902111833-3.png]]1646 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_43b671f18153910d.png?width=405&height=107&rev=1.1||alt="12.PLC Protocol_html_43b671f18153910d.png" height="107" width="405"]] 1733 1733 1648 +Set PLC IP in [Device IP] settings; 1734 1734 1735 - ConfigureEthernetIPinCommunication;1650 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_4bd3cc8348adecf8.png?width=554&height=190&rev=1.1||alt="12.PLC Protocol_html_4bd3cc8348adecf8.png" height="190" width="554"]] 1736 1736 1737 - [[image:image-20220902111121-1.png]]1652 +**Cable Wiring** 1738 1738 1739 -**4)Cable Wiring** 1740 - 1741 1741 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 1742 1742 1656 + 1743 1743 == **communicate with VB inverter** == 1744 1744 1745 1745 [[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20VB%20inverter.zip]]
- image-20220902111121-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -60.9 KB - Content
- image-20220902111754-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -57.6 KB - Content
- image-20220902111833-3.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -56.1 KB - Content