Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -704,9 +704,9 @@ 704 704 [[image:image-20220825100845-4.png]] 705 705 706 706 707 -== ** 707 +== **FX3U Ethernet Protocol** == 708 708 709 -Mitsubishi FX3U series PLC 709 + Mitsubishi FX3U series PLC 710 710 711 711 **HMI Settings** 712 712 ... ... @@ -738,14 +738,15 @@ 738 738 Set up the FX3U-ENET-L Ethernet module settings as follows. 739 739 Select the module location, which in this document is Module 0. 740 740 741 -[[image:image-20221115140802-1.png]] 742 742 742 +[[image:image-20221116105850-1.png]] 743 + 743 743 Select "Operational setting" to enter the following screen. 744 744 745 745 The Ethernet module IP is set to 192.168.39.254 in this document, and other options are default. 746 746 747 -[[image:image-20221115142728-4.png]] 748 748 749 + 749 749 Select "Open setting" to enter the setting interface, the settings are as follows. 750 750 751 751 The third item "Protocol" selects TCP, and "Open system" selects MELSOFT connection, which allows the ... ... @@ -752,8 +752,8 @@ 752 752 753 753 Mitsubishi programming software GX works2 to communicate with the FX3U via the Ethernet module. 754 754 755 -[[image:image-20221115142945-5.png]] 756 756 757 + 757 757 Click on "transter setup" - "PC side I/F setting", see the following figure. 758 758 759 759 After setting, the first download must use the programming cable, as shown in the figure; after that, can ... ... @@ -760,16 +760,16 @@ 760 760 761 761 use the IP set in the "Ethernet board" to communicate directly with the network cable. 762 762 763 -[[image:image-20221115143341-6.png||height="426" width="712"]] 764 764 765 + 765 765 Read and write data from the Ethernet module 766 766 767 -[[image:image-20221115143703-7.png]] 768 768 769 + 769 769 Set "Transter setup" to COM communication, and read or write operation as shown below 770 770 771 -[[image:image-20221115143809-8.png]] 772 772 773 + 773 773 **PLC Settings (GX Works 2)** 774 774 775 775 Create a blank FX5U project ... ... @@ -776,26 +776,28 @@ 776 776 777 777 Find Current Connection in the navigation 778 778 779 -[[image:image-20221115144335-9.png||height="422" width="706"]] 780 780 781 + 781 781 Select Connection Channel List 782 782 783 783 Select Ethernet board communication 784 784 785 -[[image:image-20221115144824-10.png||height="421" width="705"]] 786 786 787 + 787 787 Select Ethernet Module 788 788 Set the IP address of the PLC 789 789 790 -[[image:image-20221115145228-11.png||height="674" width="708"]] 791 791 792 + 792 792 Read or write PLC data, in this document is read 793 793 794 -[[image:image-20221115145553-12.png||height="424" width="711"]] 795 795 796 -[[image:image-20221115145559-13.png||height="424" width="711"]] 797 797 797 +**V-BOX Communication Setting** 798 798 799 + 800 + 801 + 799 799 == **FX5U Serial Protocol** == 800 800 801 801 Mitsubishi FX5U series PLC ... ... @@ -950,11 +950,10 @@ 950 950 951 951 [[image:image-20220825112403-1.png||alt="图片-20220825112403-1.png"]] 952 952 953 -**5) 电缆布线**956 +**5)Cable Wiring** 954 954 955 955 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 956 956 957 - 958 958 == **L02 Serial Protocol** == 959 959 960 960 Mitsubishi L02 series CPU built-in serial port.
- image-20221116105850-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bob - Size
-
... ... @@ -1,0 +1,1 @@ 1 +18.9 KB - Content