... ... @@ -704,11 +704,11 @@
704 704  [[image:image-20220825100845-4.png]]
705 705  
706 706  
707 -== ** FX3U Ethernet Protocol** ==
707 +== **FX3U Ethernet Protocol** ==
708 708  
709 -Mitsubishi FX3U series PLC
709 + Mitsubishi FX3U series PLC
710 710  
711 -**HMI Settings**
711 +**1)HMI Settings**
712 712  
713 713  |Items|Settings|Note
714 714  |Protocol|Mitsubishi FX3U|
... ... @@ -716,7 +716,7 @@
716 716  |Port No.|5009|Must be the same as the PLC setting
717 717  |PLC station No.|0|
718 718  
719 -**Address List**
719 +**2)Address List**
720 720  
721 721  |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
722 722  |(% colspan="1" rowspan="7" %)Bit|X|X|X OOO|0~~377|
... ... @@ -732,19 +732,19 @@
732 732  |SD|SD|SD DDDD|8000~~8511|
733 733  |R|R|R DDDDD|0~~32767|
734 734  
735 -**Ethernet Module Settings**
735 +**3)Ethernet Module Settings**
736 736  
737 737  FX3U-ENET-L module configuration
738 738  Set up the FX3U-ENET-L Ethernet module settings as follows.
739 739  Select the module location, which in this document is Module 0.
740 740  
741 -[[image:image-20221115140802-1.png]]
741 +[[image:image-20221116105850-1.png]]
742 742  
743 743  Select "Operational setting" to enter the following screen.
744 744  
745 745  The Ethernet module IP is set to 192.168.39.254 in this document, and other options are default.
746 746  
747 -[[image:image-20221115142728-4.png]]
747 +[[image:image-20221116105947-1.png]]
748 748  
749 749  Select "Open setting" to enter the setting interface, the settings are as follows.
750 750  
... ... @@ -752,7 +752,7 @@
752 752  
753 753  Mitsubishi programming software GX works2 to communicate with the FX3U via the Ethernet module.
754 754  
755 -[[image:image-20221115142945-5.png]]
755 +[[image:image-20221116110802-1.png]]
756 756  
757 757  Click on "transter setup" - "PC side I/F setting", see the following figure.
758 758  
... ... @@ -760,42 +760,44 @@
760 760  
761 761  use the IP set in the "Ethernet board" to communicate directly with the network cable.
762 762  
763 -[[image:image-20221115143341-6.png||height="426" width="712"]]
763 +[[image:image-20221116110832-2.png||height="423" width="708"]]
764 764  
765 765  Read and write data from the Ethernet module
766 766  
767 -[[image:image-20221115143703-7.png]]
767 +[[image:image-20221116110907-3.png]]
768 768  
769 769  Set "Transter setup" to COM communication, and read or write operation as shown below
770 770  
771 -[[image:image-20221115143809-8.png]]
771 +[[image:image-20221116110917-4.png]]
772 772  
773 -**PLC Settings (GX Works 2)**
773 +**4)PLC Settings (GX Works 2)**
774 774  
775 775  Create a blank FX5U project
776 776  
777 777  Find Current Connection in the navigation
778 778  
779 -[[image:image-20221115144335-9.png||height="422" width="706"]]
780 780  
780 +
781 781  Select Connection Channel List
782 782  
783 783  Select Ethernet board communication
784 784  
785 -[[image:image-20221115144824-10.png||height="421" width="705"]]
786 786  
786 +
787 787  Select Ethernet Module
788 788  Set the IP address of the PLC
789 789  
790 -[[image:image-20221115145228-11.png||height="674" width="708"]]
791 791  
791 +
792 792  Read or write PLC data, in this document is read
793 793  
794 -[[image:image-20221115145553-12.png||height="424" width="711"]]
795 795  
796 -[[image:image-20221115145559-13.png||height="424" width="711"]]
797 797  
796 +**V-BOX Communication Setting**
798 798  
798 +
799 +
800 +
799 799  == **FX5U Serial Protocol** ==
800 800  
801 801  Mitsubishi FX5U series PLC
... ... @@ -950,11 +950,10 @@
950 950  
951 951  [[image:image-20220825112403-1.png||alt="图片-20220825112403-1.png"]]
952 952  
953 -**5)电缆布线**
955 +**5)Cable Wiring**
954 954  
955 955  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
956 956  
957 -
958 958  == **L02 Serial Protocol** ==
959 959  
960 960  Mitsubishi L02 series CPU built-in serial port.
image-20221116105850-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +18.9 KB
Content
image-20221116105947-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +18.7 KB
Content
image-20221116110802-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +16.4 KB
Content
image-20221116110832-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +42.2 KB
Content
image-20221116110907-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +17.8 KB
Content
image-20221116110917-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +23.2 KB
Content