... ... @@ -1,1 +1,1 @@ 1 -XWiki.B ob1 +XWiki.Ben - Content
-
... ... @@ -704,97 +704,6 @@ 704 704 [[image:image-20220825100845-4.png]] 705 705 706 706 707 -== ** FX3U Ethernet Protocol** == 708 - 709 -Mitsubishi FX3U series PLC 710 - 711 -**HMI Settings** 712 - 713 -|Items|Settings|Note 714 -|Protocol|Mitsubishi FX3U| 715 -|Connection|Ethernet| 716 -|Port No.|5009|Must be the same as the PLC setting 717 -|PLC station No.|0| 718 - 719 -**Address List** 720 - 721 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 722 -|(% colspan="1" rowspan="7" %)Bit|X|X|X OOO|0~~377| 723 -|Y|Y|Y OOO|0~~377| 724 -|M|M|M DDDD|0~~7679| 725 -|SM|SM|SM DDDD|8000~~8511| 726 -|S|S|S DDDD|0~~4095| 727 -|TS|TS|TS DDD|0~~511| 728 -|CS|CS|CS DDD|0~~255| 729 -|(% colspan="1" rowspan="9" %)Word|CN|CN|CN DDD|0~~199| 730 -|TN|TN|TN DDD|0~~511| 731 -|D|D|D DDDD|0~~7999| 732 -|SD|SD|SD DDDD|8000~~8511| 733 -|R|R|R DDDDD|0~~32767| 734 - 735 -**Ethernet Module Settings** 736 - 737 -FX3U-ENET-L module configuration 738 -Set up the FX3U-ENET-L Ethernet module settings as follows. 739 -Select the module location, which in this document is Module 0. 740 - 741 -[[image:image-20221115140802-1.png]] 742 - 743 -Select "Operational setting" to enter the following screen. 744 - 745 -The Ethernet module IP is set to 192.168.39.254 in this document, and other options are default. 746 - 747 -[[image:image-20221115142728-4.png]] 748 - 749 -Select "Open setting" to enter the setting interface, the settings are as follows. 750 - 751 -The third item "Protocol" selects TCP, and "Open system" selects MELSOFT connection, which allows the 752 - 753 -Mitsubishi programming software GX works2 to communicate with the FX3U via the Ethernet module. 754 - 755 -[[image:image-20221115142945-5.png]] 756 - 757 -Click on "transter setup" - "PC side I/F setting", see the following figure. 758 - 759 -After setting, the first download must use the programming cable, as shown in the figure; after that, can 760 - 761 -use the IP set in the "Ethernet board" to communicate directly with the network cable. 762 - 763 -[[image:image-20221115143341-6.png||height="426" width="712"]] 764 - 765 -Read and write data from the Ethernet module 766 - 767 -[[image:image-20221115143703-7.png]] 768 - 769 -Set "Transter setup" to COM communication, and read or write operation as shown below 770 - 771 -[[image:image-20221115143809-8.png]] 772 - 773 -**PLC Settings (GX Works 2)** 774 - 775 -Create a blank FX5U project 776 - 777 -Find Current Connection in the navigation 778 - 779 -[[image:image-20221115144335-9.png||height="422" width="706"]] 780 - 781 -Select Connection Channel List 782 - 783 -Select Ethernet board communication 784 - 785 -[[image:image-20221115144824-10.png||height="421" width="705"]] 786 - 787 -Select Ethernet Module 788 -Set the IP address of the PLC 789 - 790 -[[image:image-20221115145228-11.png||height="674" width="708"]] 791 - 792 -Read or write PLC data, in this document is read 793 - 794 -[[image:image-20221115145553-12.png||height="424" width="711"]] 795 - 796 -[[image:image-20221115145559-13.png||height="424" width="711"]] 797 - 798 798 == **FX5U Serial Protocol** == 799 799 800 800 Mitsubishi FX5U series PLC