... ... @@ -1,1 +1,1 @@
1 -XWiki.Bob
1 +XWiki.Ben
Content
... ... @@ -704,97 +704,6 @@
704 704  [[image:image-20220825100845-4.png]]
705 705  
706 706  
707 -== ** FX3U Ethernet Protocol** ==
708 -
709 -Mitsubishi FX3U series PLC
710 -
711 -**HMI Settings**
712 -
713 -|Items|Settings|Note
714 -|Protocol|Mitsubishi FX3U|
715 -|Connection|Ethernet|
716 -|Port No.|5009|Must be the same as the PLC setting
717 -|PLC station No.|0|
718 -
719 -**Address List**
720 -
721 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
722 -|(% colspan="1" rowspan="7" %)Bit|X|X|X OOO|0~~377|
723 -|Y|Y|Y OOO|0~~377|
724 -|M|M|M DDDD|0~~7679|
725 -|SM|SM|SM DDDD|8000~~8511|
726 -|S|S|S DDDD|0~~4095|
727 -|TS|TS|TS DDD|0~~511|
728 -|CS|CS|CS DDD|0~~255|
729 -|(% colspan="1" rowspan="9" %)Word|CN|CN|CN DDD|0~~199|
730 -|TN|TN|TN DDD|0~~511|
731 -|D|D|D DDDD|0~~7999|
732 -|SD|SD|SD DDDD|8000~~8511|
733 -|R|R|R DDDDD|0~~32767|
734 -
735 -**Ethernet Module Settings**
736 -
737 -FX3U-ENET-L module configuration
738 -Set up the FX3U-ENET-L Ethernet module settings as follows.
739 -Select the module location, which in this document is Module 0.
740 -
741 -[[image:image-20221115140802-1.png]]
742 -
743 -Select "Operational setting" to enter the following screen.
744 -
745 -The Ethernet module IP is set to 192.168.39.254 in this document, and other options are default.
746 -
747 -[[image:image-20221115142728-4.png]]
748 -
749 -Select "Open setting" to enter the setting interface, the settings are as follows.
750 -
751 -The third item "Protocol" selects TCP, and "Open system" selects MELSOFT connection, which allows the
752 -
753 -Mitsubishi programming software GX works2 to communicate with the FX3U via the Ethernet module.
754 -
755 -[[image:image-20221115142945-5.png]]
756 -
757 -Click on "transter setup" - "PC side I/F setting", see the following figure.
758 -
759 -After setting, the first download must use the programming cable, as shown in the figure; after that, can
760 -
761 -use the IP set in the "Ethernet board" to communicate directly with the network cable.
762 -
763 -[[image:image-20221115143341-6.png||height="426" width="712"]]
764 -
765 -Read and write data from the Ethernet module
766 -
767 -[[image:image-20221115143703-7.png]]
768 -
769 -Set "Transter setup" to COM communication, and read or write operation as shown below
770 -
771 -[[image:image-20221115143809-8.png]]
772 -
773 -**PLC Settings (GX Works 2)**
774 -
775 -Create a blank FX5U project
776 -
777 -Find Current Connection in the navigation
778 -
779 -[[image:image-20221115144335-9.png||height="422" width="706"]]
780 -
781 -Select Connection Channel List
782 -
783 -Select Ethernet board communication
784 -
785 -[[image:image-20221115144824-10.png||height="421" width="705"]]
786 -
787 -Select Ethernet Module
788 -Set the IP address of the PLC
789 -
790 -[[image:image-20221115145228-11.png||height="674" width="708"]]
791 -
792 -Read or write PLC data, in this document is read
793 -
794 -[[image:image-20221115145553-12.png||height="424" width="711"]]
795 -
796 -[[image:image-20221115145559-13.png||height="424" width="711"]]