Changes for page 1 Communication

Last modified by Hunter on 2024/07/01 10:54

From version 167.1
edited by Bob
on 2022/11/16 09:33
Change comment: There is no comment for this version
To version 185.1
edited by Bob
on 2022/11/25 17:13
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -420,7 +420,7 @@
420 420  The above are all the steps for establishing Ethernet communication between Wecon V-box with CompactLogix L1769 PLC.
421 421  
422 422  
423 -== **Allen-Bradley Ethernet DF1** ==
423 += **Allen-Bradley Ethernet DF1** =
424 424  
425 425  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]]
426 426  
... ... @@ -704,11 +704,11 @@
704 704  [[image:image-20220825100845-4.png]]
705 705  
706 706  
707 -== ** FX3U Ethernet Protocol** ==
707 +== **FX3U Ethernet Protocol** ==
708 708  
709 -Mitsubishi FX3U series PLC
709 +Supported ModulesFX3U-ENET-ADP, FX3U-ENET-L
710 710  
711 -**HMI Settings**
711 +**1)V-BOX Settings**
712 712  
713 713  |Items|Settings|Note
714 714  |Protocol|Mitsubishi FX3U|
... ... @@ -716,7 +716,7 @@
716 716  |Port No.|5009|Must be the same as the PLC setting
717 717  |PLC station No.|0|
718 718  
719 -**Address List**
719 +**2)Address List**
720 720  
721 721  |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
722 722  |(% colspan="1" rowspan="7" %)Bit|X|X|X OOO|0~~377|
... ... @@ -732,19 +732,19 @@
732 732  |SD|SD|SD DDDD|8000~~8511|
733 733  |R|R|R DDDDD|0~~32767|
734 734  
735 -**Ethernet Module Settings**
735 +**3)Ethernet Module Settings**
736 736  
737 737  FX3U-ENET-L module configuration
738 738  Set up the FX3U-ENET-L Ethernet module settings as follows.
739 739  Select the module location, which in this document is Module 0.
740 740  
741 -[[image:image-20221115140802-1.png]]
741 +[[image:image-20221116105850-1.png]]
742 742  
743 743  Select "Operational setting" to enter the following screen.
744 744  
745 745  The Ethernet module IP is set to 192.168.39.254 in this document, and other options are default.
746 746  
747 -[[image:image-20221115142728-4.png]]
747 +[[image:image-20221116105947-1.png]]
748 748  
749 749  Select "Open setting" to enter the setting interface, the settings are as follows.
750 750  
... ... @@ -752,7 +752,7 @@
752 752  
753 753  Mitsubishi programming software GX works2 to communicate with the FX3U via the Ethernet module.
754 754  
755 -[[image:image-20221115142945-5.png]]
755 +[[image:image-20221116110802-1.png]]
756 756  
757 757  Click on "transter setup" - "PC side I/F setting", see the following figure.
758 758  
... ... @@ -760,41 +760,45 @@
760 760  
761 761  use the IP set in the "Ethernet board" to communicate directly with the network cable.
762 762  
763 -[[image:image-20221115143341-6.png||height="426" width="712"]]
763 +[[image:image-20221116110832-2.png||height="423" width="708"]]
764 764  
765 765  Read and write data from the Ethernet module
766 766  
767 -[[image:image-20221115143703-7.png]]
767 +[[image:image-20221116110907-3.png]]
768 768  
769 769  Set "Transter setup" to COM communication, and read or write operation as shown below
770 770  
771 -[[image:image-20221115143809-8.png]]
771 +[[image:image-20221116110917-4.png]]
772 772  
773 -**PLC Settings (GX Works 2)**
773 +**4)PLC Settings (GX Works 2)**
774 774  
775 775  Create a blank FX5U project
776 776  
777 777  Find Current Connection in the navigation
778 778  
779 -[[image:image-20221115144335-9.png||height="422" width="706"]]
779 +[[image:image-20221116111427-1.png||height="421" width="705"]]
780 780  
781 781  Select Connection Channel List
782 782  
783 783  Select Ethernet board communication
784 784  
785 -[[image:image-20221115144824-10.png||height="421" width="705"]]
785 +[[image:image-20221116111451-2.png||height="421" width="705"]]
786 786  
787 787  Select Ethernet Module
788 788  Set the IP address of the PLC
789 789  
790 -[[image:image-20221115145228-11.png||height="674" width="708"]]
790 +[[image:image-20221116111509-3.png||height="666" width="699"]]
791 791  
792 792  Read or write PLC data, in this document is read
793 793  
794 -[[image:image-20221115145553-12.png||height="424" width="711"]]
794 +[[image:image-20221116111651-4.png||height="416" width="697"]]
795 795  
796 -[[image:image-20221115145559-13.png||height="424" width="711"]]
796 +[[image:image-20221116111727-5.png||height="416" width="697"]]
797 797  
798 +**4)Configure the communication protocol**
799 +
800 +[[image:image-20221119101946-2.png||height="395" width="695"]]
801 +
798 798  == **FX5U Serial Protocol** ==
799 799  
800 800  Mitsubishi FX5U series PLC
... ... @@ -949,11 +949,10 @@
949 949  
950 950  [[image:image-20220825112403-1.png||alt="图片-20220825112403-1.png"]]
951 951  
952 -**5)电缆布线**
956 +**5)Cable Wiring**
953 953  
954 954  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
955 955  
956 -
957 957  == **L02 Serial Protocol** ==
958 958  
959 959  Mitsubishi L02 series CPU built-in serial port.
... ... @@ -1087,6 +1087,8 @@
1087 1087  
1088 1088  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1089 1089  
1093 +== **Q12H port Protocal** ==
1094 +
1090 1090  == **QJ71E71 Ethernet Protocol** ==
1091 1091  
1092 1092  Mitsubishi QJ71E71 Ethernet communication module;
... ... @@ -1135,10 +1135,13 @@
1135 1135  
1136 1136  * Click [Ethernet/CC IE/MELSECNET];
1137 1137  * Please select [Ethernet] as network type;
1138 -* Set station I/O number according to situation (For example, 0000 means that the module is connected to PLC CPU in first order);
1143 +* Set station I/O number according to situation (For example, 0020 means that the module is connected to PLC CPU in first order);
1139 1139  * Select [Online] as Mode;
1145 +* [[image:image-20221119171343-2.png||height="341" width="587"]]
1140 1140  * Click [Operation setting] to set IP;
1141 1141  * Select [Binary Code] as [Communication Data Code];
1148 +* [[image:image-20221119171436-3.png||height="354" width="588"]]
1149 +* Click [Open setting]
1142 1142  * Set protocol: TCP;
1143 1143  * Set [unpassive] in [Open system];
1144 1144  * Set [receive] in [Fixed buffer];
... ... @@ -1145,14 +1145,16 @@
1145 1145  * Set [procedure Exist] in [Fixed buffer communication];
1146 1146  * Disable [Pairing open];
1147 1147  * Set [No confirm] in [Existence confirmation];
1148 -* Host station port number: 1025;
1156 +* Host station port number: 5009;
1149 1149  * Save settings;
1158 +* [[image:image-20221119171611-4.png||height="354" width="588"]]
1150 1150  * Download project into PLC and restart it
1151 1151  
1152 1152  **4)Configure the communication protocol**
1153 1153  
1154 -[[image:image-20220825143728-1.png]]
1163 +[[image:image-20221119171832-5.png||height="354" width="625"]]
1155 1155  
1165 +
1156 1156  **5)Cable Wiring**
1157 1157  
1158 1158  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png"]]
image-20221116105850-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +18.9 KB
Content
image-20221116105947-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +18.7 KB
Content
image-20221116110802-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +16.4 KB
Content
image-20221116110832-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +42.2 KB
Content
image-20221116110907-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +17.8 KB
Content
image-20221116110917-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +23.2 KB
Content
image-20221116111427-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +63.4 KB
Content
image-20221116111451-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +225.5 KB
Content
image-20221116111509-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +34.1 KB
Content
image-20221116111651-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +74.3 KB
Content
image-20221116111727-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +106.2 KB
Content
image-20221116114106-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +99.5 KB
Content
image-20221119101759-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +62.1 KB
Content
image-20221119101946-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +68.7 KB
Content
image-20221119171318-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +90.3 KB
Content
image-20221119171343-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +90.3 KB
Content
image-20221119171436-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +43.4 KB
Content
image-20221119171611-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +23.1 KB
Content
image-20221119171832-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +69.6 KB
Content