... ... @@ -738,16 +738,14 @@
738 738  Set up the FX3U-ENET-L Ethernet module settings as follows.
739 739  Select the module location, which in this document is Module 0.
740 740  
741 -[[image:image-20221116094003-1.png]]
741 +[[image:image-20221115140802-1.png]]
742 742  
743 -
744 744  Select "Operational setting" to enter the following screen.
745 745  
746 746  The Ethernet module IP is set to 192.168.39.254 in this document, and other options are default.
747 747  
748 -[[image:image-20221116094019-2.png]]
747 +[[image:image-20221115142728-4.png]]
749 749  
750 -
751 751  Select "Open setting" to enter the setting interface, the settings are as follows.
752 752  
753 753  The third item "Protocol" selects TCP, and "Open system" selects MELSOFT connection, which allows the
... ... @@ -754,9 +754,8 @@
754 754  
755 755  Mitsubishi programming software GX works2 to communicate with the FX3U via the Ethernet module.
756 756  
757 -[[image:image-20221116094038-3.png]]
755 +[[image:image-20221115142945-5.png]]
758 758  
759 -
760 760  Click on "transter setup" - "PC side I/F setting", see the following figure.
761 761  
762 762  After setting, the first download must use the programming cable, as shown in the figure; after that, can
... ... @@ -763,19 +763,16 @@
763 763  
764 764  use the IP set in the "Ethernet board" to communicate directly with the network cable.
765 765  
766 -[[image:image-20221116094122-4.png||height="422" width="707"]]
763 +[[image:image-20221115143341-6.png||height="426" width="712"]]
767 767  
768 -
769 769  Read and write data from the Ethernet module
770 770  
771 -[[image:image-20221116094131-5.png||height="551" width="708"]]
767 +[[image:image-20221115143703-7.png]]
772 772  
773 -
774 774  Set "Transter setup" to COM communication, and read or write operation as shown below
775 775  
776 -[[image:image-20221116094150-6.png]]
771 +[[image:image-20221115143809-8.png]]
777 777  
778 -
779 779  **PLC Settings (GX Works 2)**
780 780  
781 781  Create a blank FX5U project
... ... @@ -782,31 +782,33 @@
782 782  
783 783  Find Current Connection in the navigation
784 784  
785 -[[image:image-20221116094206-7.png||height="425" width="711"]]
779 +[[image:image-20221115144335-9.png||height="422" width="706"]]
786 786  
787 -
788 788  Select Connection Channel List
789 789  
790 790  Select Ethernet board communication
791 791  
792 -[[image:image-20221116094709-9.png||height="427" width="715"]]
785 +[[image:image-20221115144824-10.png||height="421" width="705"]]
793 793  
794 -
795 795  Select Ethernet Module
796 796  Set the IP address of the PLC
797 797  
798 -[[image:image-20221116094736-11.png||height="682" width="716"]]
790 +[[image:image-20221115145228-11.png||height="674" width="708"]]
799 799  
800 -
801 801  Read or write PLC data, in this document is read
802 802  
803 -[[image:image-20221116094755-12.png||height="426" width="715"]]
794 +[[image:image-20221115145553-12.png||height="424" width="711"]]
804 804  
805 -[[image:image-20221116094803-13.png||height="427" width="715"]]
796 +[[image:image-20221115145559-13.png||height="424" width="711"]]
806 806  
798 +**HMI Communication Setting**
807 807  
808 -
800 +[[image:image-20221115150003-14.png||height="425" width="712"]]
809 809  
802 +[[image:image-20221115150235-15.png||height="427" width="713"]]
803 +
804 +[[image:image-20221115145559-13.png||height="424" width="711"]]
805 +
810 810  == **FX5U Serial Protocol** ==
811 811  
812 812  Mitsubishi FX5U series PLC