Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 3 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,7 +1,5 @@ 1 -= ** 1 General communicationwith PLC** =1 += **Modbus RTU** = 2 2 3 -== **Modbus RTU** == 4 - 5 5 === **V-BOX as master** === 6 6 7 7 Select the protocol “(% class="mark" %)Modbus RTU Slave(All Fuction)”, ... ... @@ -47,19 +47,215 @@ 47 47 |(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils) 48 48 |0F (Write multiple bits) 49 49 50 -= =**WECONLX3VPLC** ==48 += **WECON PLC** = 51 51 52 -S elect theprotocol(% class="mark"%)"WECON LX3V"50 +Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM 53 53 54 - (%class="mark" %)then setBaudRate,Port,Stop Bit,Data Bit,Paritysame with PLC.52 +**HMI Settings** 55 55 56 -(% class="mark" %)WECON PLC RS422 port,default communication parameters is 9600,1,7,ZEVEN 54 +|**Item**|**Settings**|**Note** 55 +|Protocol|WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM| 56 +|Connection|RS422/RS485| 57 +|Baud rate|9600| 58 +|Data bit|7| 59 +|Parity|EVEN| 60 +|Stop bit|1| 61 +|PLC station No.|1| 57 57 63 +**Address List** 64 + 65 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 66 +|(% rowspan="6" %)Bit|X|X|Xo|0~~303237| 67 +|Y|Y|Y o|0~~303237| 68 +|M|M|M d|0~~99999| 69 +|T|T|T d|0~~99999| 70 +|C|C|C d|0~~99999| 71 +|S|S|S d|0~~99999| 72 +|(% rowspan="8" %)Word|X|X|Xo|0~~303237| 73 +|Y|Y|Y o|0~~303237| 74 +|M|M|M d|0~~99999| 75 +|T|T|T d|0~~99999| 76 +|C|C|C d|0~~199| 77 +|D|D|D d|0~~7999| 78 +|S|S|S d|0~~99999| 79 +|SD|SD|SD d|8000~~9999| 80 + 81 +**Cable Wiring** 82 + 83 +* **RS485** 84 + 85 + [[image:image-20220822172124-1.png]] 86 + 87 +* **RS422** 88 + 89 + [[image:image-20220822172228-2.png]] 90 + 91 + 92 +**✎Note:** 93 + 94 +* HMI COM3 is available in PI8000 series and COM3 is in COM2(hardware PIN 7 and PIN 8) . 95 +* If PLC <= 20 points,such as LX3V-1208/LX3V-0806 PLC,PLC RS485A and RS485B mean PLC COM2 RS485+ and RS485- .PLC COM2 can support modbus. Please refer to PLC COM2 setting manual. 96 + 97 +[[https:~~/~~/drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing>>url:https://drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing]] 98 + 99 + 100 +== **V-BOX and Wecon LX5V serial communication** == 101 + 102 +This example introduces the establishment of serial port communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 103 + 104 +**Software configuration of PLC** 105 + 106 +**1)PLC programming software** 107 + 108 +[[image:image-20220810164710-1.png]] 109 + 110 + 111 +**2)New PLC project** 112 + 113 +Click New Project and select the PLC model. 114 + 115 +[[image:image-20220810172412-1.png]] 116 + 117 + 118 +**3)Set Serial port parameters** 119 + 120 +Follow the steps below to configure Serial port parameters 121 + 122 +Baud rate:115200 123 + 124 +Data bit:8 125 + 126 +Stop bit:1 127 + 128 +Parity:No verification 129 + 130 +[[image:image-20220810165759-3.png]] 131 + 132 + 133 +**4)Registers list** 134 + 135 +[[image:image-20220811102219-3.png]] 136 + 137 + 138 +**HMI software configuration** 139 + 140 +**1)HMI programming software** 141 + 142 + [[image:image-20220810171237-4.png]] 143 + 144 +**2)New HMI project** 145 + 146 +Click New Project and select the HMI model. 147 + 148 +[[image:image-20220810172010-5.png]] 149 + 150 + 151 +**3)Set communication port parameters** 152 + 153 +Click the communication configuration button on the left to find the communication protocol with LX5V. After selecting the protocol, configure the communication parameters of the COM port. 154 + 155 +Baud rate:115200 156 + 157 +Data bit:8 158 + 159 +Stop bit:1 160 + 161 +Parity:No verification 162 + 163 +[[image:image-20220811104012-1.png]] 164 + 165 + 166 +**hardware connection** 167 + 168 +**1)Hardware wiring diagram** 169 + 170 +This example introduces WeconHMI with LX5V PLC to establish communication through serial port. The connection diagram is as follows: 171 + 172 + 173 + 174 +[[image:image-20220811103005-4.png]] 175 + 176 +[[image:image-20220811103227-7.png]] 177 + 178 +The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC. 179 + 180 +== **HMI and Wecon LX5V-N Ethernet communication** == 181 + 182 + This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 183 + 184 +**Software configuration of PLC** 185 + 186 +**1)PLC programming software** 187 + 188 +[[image:image-20220810164710-1.png]] 189 + 190 +**2)New PLC project** 191 + 192 +Click New Project and select the PLC model. 193 + 194 +[[image:image-20220811115454-1.png]] 195 + 196 +**3)Set Ethernet port parameters** 197 + 198 +Follow the steps below to configure Ethernet parameters 199 + 200 +PLC IP address:192.168.39.200 201 + 202 +default gateway:192.168.39.1 203 + 204 +subnet mask:255.255.255.0 205 + 206 +[[image:image-20220811140530-2.png]] 207 + 208 +**4)Registers list** 209 + 210 +[[image:image-20220811102219-3.png]] 211 + 212 +**HMI software configuration** 213 + 214 +**1)HMI programming software** 215 + 216 + [[image:image-20220810171237-4.png]] 217 + 218 +**2)New HMI project** 219 + 220 +Click New Project and select the HMI model. 221 + 222 +[[image:image-20220810172010-5.png]] 223 + 224 +**3)Set communication port parameters** 225 + 226 +Click the project setting button on the left to configure the IP address of the HMI machine to ensure that the HMI and PLC IP remain in a local area network. 227 + 228 +HMI IP address:192.168.39.201 229 + 230 +default gateway:192.168.39.1 231 + 232 +subnet mask:255.255.255.0 233 + 234 +[[image:image-20220811170753-2.png]] 235 + 236 +Next, click Communication Settings to configure the IP of the HMI communication object. 237 + 238 +[[image:image-20220811163047-1.png]] 239 + 240 +**hardware connection** 241 + 242 +**1)Hardware wiring diagram** 243 + 244 +This example introduces WeconHMI with LX5V-N PLC to establish communication through ethernet. The connection diagram is as follows: 245 + 246 +[[image:image-20220811170248-1.png]] 247 + 248 +The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC. 249 + 58 58 (% style="text-align:center" %) 59 59 [[image:1624348978863-771.png||queryString="width=812&height=494" height="487" width="800" class="img-thumbnail"]] 60 60 61 -= =**2 Communicationwith Allen-Bradley CompactLogixL1769** ==253 += **Rockwell PLC** = 62 62 255 +== **Communication with AB CompactLogix L1769** == 256 + 63 63 ((( 64 64 ((( 65 65 This example introduces the establishment of Ethernet communication between Wecon V-box and Allen-Bradley L1769. It is introduced through three parts: PLC software configuration, V-box software configuration, and hardware wiring. ... ... @@ -199,7 +199,7 @@ 199 199 200 200 ((( 201 201 ((( 202 -Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device. [[image:image-20220714162752-8.png]]396 +Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device. [[image:image-20220714162752-8.png]] 203 203 ))) 204 204 205 205 ... ... @@ -226,7 +226,7 @@ 226 226 227 227 228 228 ((( 229 -After adding the protocol Allen-BradleyMicro850_FreeTag, click[[image:image-20220714143838-2.png]]icon add label. [[image:image-20220714162827-11.png]]423 +After adding the protocol Allen-BradleyMicro850_FreeTag, click[[image:image-20220714143838-2.png]]icon add label.[[image:image-20220714162827-11.png]] 230 230 ))) 231 231 232 232 (% class="wikigeneratedid" id="HEngineeringproduction" %) ... ... @@ -261,6 +261,14 @@ 261 261 262 262 ((( 263 263 The above are all the steps for establishing Ethernet communication between Wecon V-box with Allen-Bradley L1769 PLC. 458 + 459 + 460 +== **Allen-Bradley Ethernet DF1** == 461 + 462 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]] 463 + 464 + 465 += **Siemens PLC** = 264 264 ))) 265 265 ))) 266 266 ... ... @@ -268,14 +268,12 @@ 268 268 269 269 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]] 270 270 271 -== **Allen-Bradley Ethernet DF1** == 272 - 273 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]] 274 - 275 275 == **Communication with S7-200 Smart** == 276 276 277 277 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]] 278 278 477 += **Delta PLC** = 478 + 279 279 == **Delta DVP Ethernet** == 280 280 281 281 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]] ... ... @@ -302,7 +302,7 @@ 302 302 303 303 = **2 User define protocol** = 304 304 305 -More serial port script instruction,please refer manual:[[Lua script function>>doc:V-BOX.V-Net. 1\.UserManual.04 Lua Script.01 Lua Functions.WebHome]]~-~-->[[3.Serial port operation>>url:http://docs.we-con.com.cn/wiki/vbox/view/HMI/04.Lua%20script%20%20function%20and%20operation/01.Lua%20script%20function/#H3.Serialportoperation]]505 +More serial port script instruction,please refer manual:[[Lua script function>>doc:V-BOX.V-Net.Manual.04 Lua Script.01 Lua Functions.WebHome]]~-~-->[[3.Serial port operation>>url:http://docs.we-con.com.cn/wiki/vbox/view/HMI/04.Lua%20script%20%20function%20and%20operation/01.Lua%20script%20function/#H3.Serialportoperation]] 306 306 307 307 == **Read the temperature sensor.** == 308 308
- image-20220820164423-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +18.4 KB - Content
- image-20220822172124-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +38.7 KB - Content
- image-20220822172228-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +48.8 KB - Content