Changes for page 1 Communication

Last modified by Hunter on 2024/07/01 10:54

From version 17.1
edited by Ben
on 2022/07/14 16:29
Change comment: There is no comment for this version
To version 78.1
edited by Ben
on 2022/08/24 15:16
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,71 +1,224 @@
1 -= **1 General communication with PLC** =
1 += (% style="color:inherit; font-family:inherit" %)**WECON PLC**(%%) =
2 2  
3 -== **Modbus RTU** ==
3 +== **LX3V Serial Protocol** ==
4 4  
5 -=== **V-BOX as master** ===
5 +Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM
6 6  
7 -Select the protocol “(% class="mark" %)Modbus RTU Slave(All Fuction)”,
7 +**HMI Settings**
8 8  
9 -(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity
9 +|**Item**|**Settings**|**Note**
10 +|Protocol|WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM|
11 +|Connection|RS422/RS485|
12 +|Baud rate|9600|
13 +|Data bit|7|
14 +|Parity|EVEN|
15 +|Stop bit|1|
16 +|PLC station No.|1|
10 10  
11 -(% style="text-align:center" %)
12 -[[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]]
18 +**Address List**
13 13  
14 -=== **V-BOX as slave** ===
20 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
21 +|(% rowspan="6" %)Bit|X|X|Xo|0~~303237|
22 +|Y|Y|Y o|0~~303237|
23 +|M|M|M d|0~~99999|
24 +|T|T|T d|0~~99999|
25 +|C|C|C d|0~~99999|
26 +|S|S|S d|0~~99999|
27 +|(% rowspan="8" %)Word|X|X|Xo|0~~303237|
28 +|Y|Y|Y o|0~~303237|
29 +|M|M|M d|0~~99999|
30 +|T|T|T d|0~~99999|
31 +|C|C|C d|0~~199|
32 +|D|D|D d|0~~7999|
33 +|S|S|S d|0~~99999|
34 +|SD|SD|SD d|8000~~9999|
15 15  
16 -Select the protocol “(% class="mark" %)**Modbus RTU Master**,
36 +**Cable Wiring**
17 17  
18 -(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity
38 +* **RS422**
19 19  
20 -(% style="text-align:center" %)
21 -[[image:1624348709622-711.png||queryString="width=809&height=493" height="488" width="800" class="img-thumbnail"]]
40 + [[image:image-20220824120614-5.png]]
22 22  
23 -**Address List**
42 +* **RS485**
24 24  
25 -(% class="table-bordered" %)
26 -|**Type**|**Register**|**Function code & Description**
27 -|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers)
28 -|06 (write single register: write a binary value to a holding register)
29 -|10 (write values to multiple addresses )
30 -|(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers)
31 -|06 (write single register: write a binary value to a holding register)
32 -|10 (write values to multiple addresses )
33 -|(% rowspan="3" %)W6|03 (read holding register: read current binary value in one or more holding registers)
34 -|06 (write single register: write a binary value to a holding register)
35 -|10 (write values to multiple addresses )
36 -|(% rowspan="2" %)W16|03 (read holding register: read current binary value in one or more holding registers)
37 -|10 (write values to multiple addresses )
38 -|(% rowspan="11" %)Bit|(% rowspan="3" %)0|01 (Read coil state)
39 -|05 (Force a single coil to force the on/off state of a logic coil)
40 -|0F (Write multiple bits, ie write continuously)
41 -|(% rowspan="3" %)1|02 (Read the input state)
42 -|05 (Force a single coil to force the on/off state of a logic coil)
43 -|0F (Write multiple bits)
44 -|(% rowspan="3" %)W5|01 (Read coil state to obtain the current state of a set of logic coils)
45 -|05 (Force a single coil to force the on/off state of a logic coil)
46 -|0F (Write multiple bits)
47 -|(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils)
48 -|0F (Write multiple bits)
44 + [[image:image-20220824120524-3.png]]
49 49  
50 -== **WECON LX3V PLC** ==
46 +== **LX5V Serial Protocol** ==
51 51  
52 -Select the protocol (% class="mark" %)"WECON LX3V"
48 +This example introduces the establishment of serial port communication between Wecon V-BOX and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
53 53  
54 -(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity same with PLC.
50 +**Software configuration of PLC**
55 55  
56 -(% class="mark" %)WECON PLC RS422 port,default communication parameters is 9600,1,7,ZEVEN
52 +**1)PLC programming software**
57 57  
58 -(% style="text-align:center" %)
59 -[[image:1624348978863-771.png||queryString="width=812&height=494" height="487" width="800" class="img-thumbnail"]]
54 +[[image:image-20220824142722-1.png]]
60 60  
61 -== **2 Communication with Allen-Bradley CompactLogix L1769** ==
56 +**2)New PLC project**
62 62  
58 +Click New Project and select the PLC model.
59 +
60 +[[image:image-20220822172623-2.png]]
61 +
62 +**3)Set Serial port parameters**
63 +
64 +Follow the steps below to configure Serial port parameters
65 +
66 +Baud rate:115200
67 +
68 +Data bit:8
69 +
70 +Stop bit:1
71 +
72 +Parity:No verification
73 +
74 +[[image:image-20220822172657-3.png]]
75 +
76 +**4)Registers list**
77 +
78 +[[image:image-20220822172730-4.png]]
79 +
80 +**V-BOX software configuration**
81 +
82 +**1)V-BOX programming software**
83 +
84 + [[image:image-20220824104124-1.png]]
85 +
86 +**2)V-NET add device**
87 +
88 +Open V-NET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the access key, password and remark, to add the device.
89 +
90 +[[image:image-20220824104909-2.png]]
91 +
92 +
93 +**3)Set communication port parameters**
94 +
95 +Click the communication configuration button on the left to find the communication protocol with LX5V. After selecting the protocol, configure the communication parameters of the COM port.
96 +
97 +Baud rate:115200
98 +
99 +Data bit:8
100 +
101 +Stop bit:1
102 +
103 +Parity:No verification
104 +
105 +[[image:image-20220824142130-1.png]]
106 +
107 +**hardware connection**
108 +
109 +**1)Hardware wiring diagram**
110 +
111 +[[image:image-20220824142546-2.png]]
112 +
113 +[[image:image-20220824142643-3.png]]
114 +
115 +The above are all the steps for establishing serial port communication between V-BOX with LX5V PLC.
116 +
117 +== **LX5V-N Ethernet protocol** ==
118 +
119 +This example introduces the establishment of Ethernet communication between V-BOX and LX5V-N. It is introduced through three parts: PLC software configuration, V-BOX software configuration, and hardware wiring.
120 +
121 +**Software configuration of PLC**
122 +
123 +**1)PLC programming software**
124 +
125 +[[image:image-20220824142722-1.png]]
126 +
127 +**2)New PLC project**
128 +
129 +Click New Project and select the PLC model.
130 +
131 +[[image:image-20220824143613-1.png]]
132 +
133 +**3)Set Ethernet port parameters**
134 +
135 +Follow the steps below to configure Ethernet parameters
136 +
137 +PLC IP address:192.168.39.200
138 +
139 +default gateway:192.168.39.1
140 +
141 +subnet mask:255.255.255.0
142 +
143 +[[image:image-20220824143744-2.png]]
144 +
145 +**4)Registers list**
146 +
147 +[[image:image-20220822172730-4.png]]
148 +
149 +(% id="cke_bm_22473S" style="display:none" %)** **(%%)**V-BOX software configuration**
150 +
151 +**1)V-BOX programming software**
152 +
153 + [[image:image-20220824104124-1.png]]
154 +
155 +**2)V-NET add device**
156 +
157 +Open V-NET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the access key, password and remark, to add the device.
158 +
159 +[[image:image-20220824104909-2.png]]
160 +
161 +**3)Set communication port parameters**
162 +
163 +Click Communication to configure the LX5V plc protocol and IP address.
164 +
165 +[[image:image-20220824144619-1.png]]
166 +
167 +**hardware connection**
168 +
169 +**1)Hardware wiring diagram**
170 +
171 +[[image:image-20220824151127-2.png]]
172 +
173 +The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC.
174 +
175 += **Rockwell PLC** =
176 +
177 +== (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** ==
178 +
179 +MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
180 +
181 +**HMI Settings**
182 +
183 +|**Item**|**Settings**|**Note**
184 +|Protocol|Allen-Bradlley MicroLogix|
185 +|Connection|RS232|
186 +|Baud rate|19200|
187 +|Data bit|8|
188 +|Parity|None|
189 +|Stop bit|1|
190 +|PLC station No.|1|
191 +
192 +**Address List**
193 +
194 +|**Type**|**Device registers**|**Format**|**Range**|**Note**
195 +|(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15|
196 +|O|O d.d|0.0~~255.15|
197 +|B|B nnhh.dd|0.0~~ffff.15|nn: block number (hex)
198 +|S|S d.d|0.0~~255.15|
199 +|N|N nnhh.dd|0.0~~ffff.15|nn: block number (hex)
200 +|(% rowspan="9" %)Word|S|S d|0~~255|
201 +|TS|TS nnhh|0~~ffff|(% rowspan="8" %)nn: block number (hex)
202 +|TP|TP nnhh|0~~ffff
203 +|CS|CS nnhh|0~~ffff
204 +|CP|CP nnhh|0~~ffff
205 +|N|N nnhh|0~~ffff
206 +|C|C nnhh|0~~ffff
207 +|T|T nnhh|0~~ffff
208 +|R|R nnhh|0~~ffff
209 +
210 +**Cable Wiring**
211 +
212 +[[image:image-20220824110724-1.png]]
213 +
214 +
215 +
216 +== **CompactLogix Protocol** ==
217 +
63 63  (((
64 64  (((
65 -This example introduces the establishment of Ethernet communication between Wecon V-box and Allen-Bradley L1769. It is introduced through three parts: PLC software configuration, V-box software configuration, and hardware wiring.
220 +This example introduces the establishment of Ethernet communication between Wecon V-box and CompactLogix L1769. It is introduced through three parts: PLC software configuration, V-box software configuration, and hardware wiring.
66 66  )))
67 -
68 -
69 69  )))
70 70  
71 71  (((
... ... @@ -199,7 +199,7 @@
199 199  
200 200  (((
201 201  (((
202 -Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device.   ​​​​​​​[[image:image-20220714162752-8.png]]
355 +Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device.   [[image:image-20220714162752-8.png]]
203 203  )))
204 204  
205 205  
... ... @@ -226,7 +226,7 @@
226 226  
227 227  
228 228  (((
229 -After adding the protocol Allen-BradleyMicro850_FreeTag, click[[image:image-20220714143838-2.png]]icon add label.​​​​​​​[[image:image-20220714162827-11.png]]
382 +After adding the protocol Allen-BradleyMicro850_FreeTag, click[[image:image-20220714143838-2.png]]icon add label.[[image:image-20220714162827-11.png]]
230 230  )))
231 231  
232 232  (% class="wikigeneratedid" id="HEngineeringproduction" %)
... ... @@ -260,50 +260,107 @@
260 260  [[image:image-20220714162856-13.png]]
261 261  
262 262  (((
263 -The above are all the steps for establishing Ethernet communication between Wecon V-box with Allen-Bradley L1769 PLC.
416 +The above are all the steps for establishing Ethernet communication between Wecon V-box with CompactLogix L1769 PLC.
417 +
418 +
419 +== **Allen-Bradley Ethernet DF1** ==
420 +
421 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]]
422 +
423 +
424 += **Siemens PLC** =
425 +
426 +== **S7-200 Smart Ethernet Protocol** ==
427 +
428 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]]
264 264  )))
265 265  )))
266 266  
267 -== **Siemens S7-1200** ==
432 +== **S7-1200 Ethernet Protocol** ==
268 268  
269 269  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]]
270 270  
271 -== **Allen-Bradley Ethernet DF1** ==
436 += **Mitsubishi PLC** =
272 272  
273 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]]
438 +== **Mitsubishi FX Series Protocol** ==
274 274  
275 -== **Communication with S7-200 Smart** ==
440 +[[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20Mitsubishi%20FX%20Series.zip]]
276 276  
277 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]]
442 += **Delta PLC** =
278 278  
279 -== **Delta DVP Ethernet** ==
444 +== **DVP Ethernet Protocol** ==
280 280  
281 281  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
282 282  
283 -== **Delta DVP Serial Protocol** ==
448 +== **DVP Serial Protocol** ==
284 284  
285 285  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
286 286  
287 -== **Communicate with Mitsubishi FX Series** ==
452 += **Omron PLC** =
288 288  
289 -[[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20Mitsubishi%20FX%20Series.zip]]
454 +== **CP1 Series Protocol** ==
290 290  
291 -== **Communicate with VB inverter** ==
456 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]]
292 292  
293 -[[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20VB%20inverter.zip]]
458 +== **CJ2M Series Protocol** ==
294 294  
295 -== **Omron CP1 Series** ==
460 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]]
296 296  
297 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]]
462 += **Modbus RTU** =
298 298  
299 -== **Omron CJ2M** ==
464 +== **V-BOX as master** ==
300 300  
301 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]]
466 +Select the protocol “(% class="mark" %)Modbus RTU Slave(All Fuction)”,
302 302  
303 -= **2 User define protocol** =
468 +(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity
304 304  
305 -More serial port script instruction,please refer manual:[[Lua script function>>doc:V-BOX.V-Net.1\.User Manual.04 Lua Script.01 Lua Functions.WebHome]]~-~-->[[3.Serial port operation>>url:http://docs.we-con.com.cn/wiki/vbox/view/HMI/04.Lua%20script%20%20function%20and%20operation/01.Lua%20script%20function/#H3.Serialportoperation]]
470 +(% style="text-align:center" %)
471 +[[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]]
306 306  
473 +== **V-BOX as slave** ==
474 +
475 +Select the protocol “(% class="mark" %)**Modbus RTU Master”**,
476 +
477 +(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity
478 +
479 +(% style="text-align:center" %)
480 +[[image:1624348709622-711.png||queryString="width=809&height=493" height="488" width="800" class="img-thumbnail"]]
481 +
482 +**Address List**
483 +
484 +(% class="table-bordered" %)
485 +|**Type**|**Register**|**Function code & Description**
486 +|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers)
487 +|06 (write single register: write a binary value to a holding register)
488 +|10 (write values to multiple addresses )
489 +|(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers)
490 +|06 (write single register: write a binary value to a holding register)
491 +|10 (write values to multiple addresses )
492 +|(% rowspan="3" %)W6|03 (read holding register: read current binary value in one or more holding registers)
493 +|06 (write single register: write a binary value to a holding register)
494 +|10 (write values to multiple addresses )
495 +|(% rowspan="2" %)W16|03 (read holding register: read current binary value in one or more holding registers)
496 +|10 (write values to multiple addresses )
497 +|(% rowspan="11" %)Bit|(% rowspan="3" %)0|01 (Read coil state)
498 +|05 (Force a single coil to force the on/off state of a logic coil)
499 +|0F (Write multiple bits, ie write continuously)
500 +|(% rowspan="3" %)1|02 (Read the input state)
501 +|05 (Force a single coil to force the on/off state of a logic coil)
502 +|0F (Write multiple bits)
503 +|(% rowspan="3" %)W5|01 (Read coil state to obtain the current state of a set of logic coils)
504 +|05 (Force a single coil to force the on/off state of a logic coil)
505 +|0F (Write multiple bits)
506 +|(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils)
507 +|0F (Write multiple bits)
508 +
509 +== **communicate with VB inverter** ==
510 +
511 +[[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20VB%20inverter.zip]]
512 +
513 += **User define protocol** =
514 +
515 +More serial port script instruction,please refer manual:[[Lua script function>>doc:V-BOX.V-Net.Manual.04 Lua Script.01 Lua Functions.WebHome]]~-~-->[[3.Serial port operation>>url:http://docs.we-con.com.cn/wiki/vbox/view/HMI/04.Lua%20script%20%20function%20and%20operation/01.Lua%20script%20function/#H3.Serialportoperation]]
516 +
307 307  == **Read the temperature sensor.** ==
308 308  
309 309  the commond format is as beliow:
image-20220820164423-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +18.4 KB
Content
image-20220822172124-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +38.7 KB
Content
image-20220822172228-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +48.8 KB
Content
image-20220822172553-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +19.9 KB
Content
image-20220822172623-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +111.2 KB
Content
image-20220822172657-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +141.6 KB
Content
image-20220822172730-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +130.7 KB
Content
image-20220824104124-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +14.6 KB
Content
image-20220824104909-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +278.8 KB
Content
image-20220824110724-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +79.1 KB
Content
image-20220824120406-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +31.9 KB
Content
image-20220824120507-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +10.3 KB
Content
image-20220824120524-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +23.4 KB
Content
image-20220824120547-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +49.2 KB
Content
image-20220824120614-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +30.9 KB
Content
image-20220824142130-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +122.2 KB
Content
image-20220824142546-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +111.2 KB
Content
image-20220824142643-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +38.3 KB
Content
image-20220824142722-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +7.3 KB
Content
image-20220824143613-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +206.2 KB
Content
image-20220824143744-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +126.0 KB
Content
image-20220824144619-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +126.2 KB
Content
image-20220824151127-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +85.5 KB
Content