... ... @@ -1,1 +1,1 @@
1 -XWiki.Bob
1 +XWiki.Ben
Content
... ... @@ -182,7 +182,7 @@
182 182  
183 183  MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
184 184  
185 -**1)V-BOX setting**
185 +**1)PLC Settings**
186 186  
187 187  |**Item**|**Settings**|**Note**
188 188  |Protocol|Allen-Bradlley DF1 Advanced|
... ... @@ -436,7 +436,7 @@
436 436  
437 437  Supported Series: Siemens S7-300 series PLC
438 438  
439 -**1)V-BOX setting**
439 +**1)PLC Setting**
440 440  
441 441  |**Items**|**Settings**|**Note**
442 442  |Protocol|Simens S7-300 Ethernet|
... ... @@ -498,7 +498,7 @@
498 498  
499 499  Supported Series: Siemens S7-400, S7-1200 and S7-1500
500 500  
501 -**1)V-BOX setting**
501 +**1)PLC Setting**
502 502  
503 503  |=**Items**|=**Settings**|=**Note**
504 504  |Protocol|Siemens S7-XXX|
... ... @@ -704,112 +704,6 @@
704 704  [[image:image-20220825100845-4.png]]
705 705  
706 706  
707 -== **FX3U Ethernet Protocol** ==
708 -
709 - Mitsubishi FX3U series PLC
710 -
711 -**HMI Settings**
712 -
713 -|Items|Settings|Note
714 -|Protocol|Mitsubishi FX3U|
715 -|Connection|Ethernet|
716 -|Port No.|5009|Must be the same as the PLC setting
717 -|PLC station No.|0|
718 -
719 -**Address List**
720 -
721 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
722 -|(% colspan="1" rowspan="7" %)Bit|X|X|X OOO|0~~377|
723 -|Y|Y|Y OOO|0~~377|
724 -|M|M|M DDDD|0~~7679|
725 -|SM|SM|SM DDDD|8000~~8511|
726 -|S|S|S DDDD|0~~4095|
727 -|TS|TS|TS DDD|0~~511|
728 -|CS|CS|CS DDD|0~~255|
729 -|(% colspan="1" rowspan="9" %)Word|CN|CN|CN DDD|0~~199|
730 -|TN|TN|TN DDD|0~~511|
731 -|D|D|D DDDD|0~~7999|
732 -|SD|SD|SD DDDD|8000~~8511|
733 -|R|R|R DDDDD|0~~32767|
734 -
735 -**Ethernet Module Settings**
736 -
737 -FX3U-ENET-L module configuration
738 -Set up the FX3U-ENET-L Ethernet module settings as follows.
739 -Select the module location, which in this document is Module 0.
740 -
741 -[[image:image-20221116094003-1.png]]
742 -
743 -
744 -Select "Operational setting" to enter the following screen.
745 -
746 -The Ethernet module IP is set to 192.168.39.254 in this document, and other options are default.
747 -
748 -[[image:image-20221116094019-2.png]]
749 -
750 -
751 -Select "Open setting" to enter the setting interface, the settings are as follows.
752 -
753 -The third item "Protocol" selects TCP, and "Open system" selects MELSOFT connection, which allows the
754 -
755 -Mitsubishi programming software GX works2 to communicate with the FX3U via the Ethernet module.
756 -
757 -[[image:image-20221116094038-3.png]]
758 -
759 -
760 -Click on "transter setup" - "PC side I/F setting", see the following figure.
761 -
762 -After setting, the first download must use the programming cable, as shown in the figure; after that, can
763 -
764 -use the IP set in the "Ethernet board" to communicate directly with the network cable.
765 -
766 -[[image:image-20221116094122-4.png||height="422" width="707"]]
767 -
768 -
769 -Read and write data from the Ethernet module
770 -
771 -[[image:image-20221116094131-5.png||height="551" width="708"]]
772 -
773 -
774 -Set "Transter setup" to COM communication, and read or write operation as shown below
775 -
776 -[[image:image-20221116094150-6.png]]
777 -
778 -
779 -**PLC Settings (GX Works 2)**
780 -
781 -Create a blank FX5U project
782 -
783 -Find Current Connection in the navigation
784 -
785 -[[image:image-20221116094206-7.png||height="425" width="711"]]
786 -
787 -
788 -Select Connection Channel List
789 -
790 -Select Ethernet board communication
791 -
792 -[[image:image-20221116094709-9.png||height="427" width="715"]]
793 -
794 -
795 -Select Ethernet Module
796 -Set the IP address of the PLC
797 -
798 -[[image:image-20221116094736-11.png||height="682" width="716"]]
799 -
800 -
801 -Read or write PLC data, in this document is read
802 -
803 -[[image:image-20221116094755-12.png||height="426" width="715"]]
804 -
805 -[[image:image-20221116094803-13.png||height="427" width="715"]]
806 -
807 -**V-BOX Communication Setting**
808 -
809 -
810 -
811 -
812 -
813 813  == **FX5U Serial Protocol** ==
814 814  
815 815  Mitsubishi FX5U series PLC
... ... @@ -1418,50 +1418,15 @@
1418 1418  
1419 1419  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830160232-3.png?rev=1.1||alt="image-20220830160232-3.png"]]
1420 1420  
1315 += Create communication with Inovance** PLC**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=37]] =
1421 1421  
1422 -= Create communication with **Schneider PLC** =
1317 +== **H3U serial protocol**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=38]] ==
1423 1423  
1424 -== **Schneider MODBUS RTU** ==
1319 +**1)HMI Settings**
1425 1425  
1426 -**1)V-BOX Setting**
1427 -
1428 -|=**Parameters**|=**Recommended**|=**Notes**
1429 -|**Protocol**|(% colspan="1" %)Schneider MODBUS RTU|
1430 -|**Connection**|RS485|
1431 -|**Baud rate**|19200|
1432 -|**Data bit**|8|
1433 -|**Parity**|Even|
1434 -|**Stop bit**|1|
1435 -|**PLC station No.**|1|
1436 -
1437 -**2)Address List**
1438 -
1439 -|=**Bit/Word**|=**Device type**|=**Format**|=**Range**|=**Memo**
1440 -|B|IX|DDDDDo|0 ~~ 655357|Input bit (read only)
1441 -|B|QX|DDDDDo|0 ~~ 655357|Write multiple coils
1442 -|B|MX|DDDDDDo|0 ~~ 9999997|Output register bit (octal)
1443 -|W|MW|DDDDDD|0 ~~ 999999|Output register
1444 -|DW|MD|DDDDDD|0 ~~ 999999|Output register
1445 -
1446 -**3)Configure the communication protocol**
1447 -
1448 -[[image:image-20220902104329-1.png]]
1449 -
1450 -**4)Cable Wiring**
1451 -
1452 -**RS-485 2W **(RJ45 Connector): The following is the view from the soldering point of a connector.
1453 -
1454 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220817154212-1.jpeg?width=554&height=315&rev=1.1||alt="image-20220817154212-1.jpeg" height="315" width="554"]]
1455 -
1456 -= Create communication with Inovance** PLC** =
1457 -
1458 -== **H3U serial protocol** ==
1459 -
1460 -**1)V-BOX Settings**
1461 -
1462 1462  |**Item**|**Settings**|**Note**
1463 1463  |Protocol|INOVANCE H3U PLC|
1464 -|Connection|RS422|
1323 +|Connection|RS22|
1465 1465  |Baud rate|9600|
1466 1466  |Data bit|7|
1467 1467  |Parity|EVEN|
... ... @@ -1491,25 +1491,25 @@
1491 1491  
1492 1492  **3)Configure the communication protocol**
1493 1493  
1494 -[[image:image-20220831164626-1.png]]
1353 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830170114-4.png?rev=1.1||alt="image-20220830170114-4.png"]]
1495 1495  
1355 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830170017-3.png?rev=1.1||alt="image-20220830170017-3.png"]]
1496 1496  
1497 -
1498 1498  **4)Cable Wiring**
1499 1499  
1500 1500  Figure
1501 1501  
1502 -[[image:image-20220831164646-2.png]][[image:image-20220831164700-3.png]]
1361 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830165930-1.png?rev=1.1||alt="image-20220830165930-1.png"]]
1503 1503  
1504 1504  Pin Definition Diagram
1505 1505  
1506 -[[image:image-20220831164731-4.png]]
1365 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830165947-2.png?rev=1.1||alt="image-20220830165947-2.png"]]
1507 1507  
1508 -= Create communication with Panasonic** PLC** =
1367 += Create communication with Panasonic** PLC**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=39]] =
1509 1509  
1510 -== **FP serial protocol** ==
1369 +== **FP serial protocol**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=40]] ==
1511 1511  
1512 -**1)V-BOX Settings**
1371 +**1)HMI Settings**
1513 1513  
1514 1514  |**Item**|**Settings**|**Note**
1515 1515  |Protocol|Panasonic FP MFWTOCOL|
... ... @@ -1541,25 +1541,25 @@
1541 1541  
1542 1542  **3)Configure the communication protocol**
1543 1543  
1544 -[[image:image-20220831165238-4.png]]
1403 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830171050-1.png?rev=1.1||alt="image-20220830171050-1.png"]]
1545 1545  
1405 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830171126-2.png?rev=1.1||alt="image-20220830171126-2.png"]]
1546 1546  
1547 -
1548 1548  **4)Cable Wiring**
1549 1549  
1550 1550  Figure
1551 1551  
1552 -[[image:image-20220831165031-3.png]][[image:image-20220831165017-2.png]]
1411 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830171328-4.png?rev=1.1||alt="image-20220830171328-4.png"]]
1553 1553  
1554 1554  Pin Definition Diagram
1555 1555  
1556 -[[image:image-20220831165008-1.png]]
1415 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830171146-3.png?rev=1.1||alt="image-20220830171146-3.png"]]
1557 1557  
1558 -= Create communication with LS** PLC** =
1417 += Create communication with LS** PLC**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=41]] =
1559 1559  
1560 -== **XBC serial protocol** ==
1419 +== **XBC serial protocol**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=42]] ==
1561 1561  
1562 -**1)V-BOX Settings**
1421 +**1)HMI Settings**
1563 1563  
1564 1564  |**Item**|**Settings**|**Note**
1565 1565  |Protocol|LS XBC CNet|
... ... @@ -1597,23 +1597,25 @@
1597 1597  
1598 1598  **3)Configure the communication protocol**
1599 1599  
1600 -[[image:image-20220831170147-1.png]]
1459 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830174853-3.png?rev=1.1||alt="image-20220830174853-3.png"]]
1601 1601  
1461 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830174733-2.png?rev=1.1||alt="image-20220830174733-2.png"]]
1462 +
1602 1602  **4)Cable Wiring**
1603 1603  
1604 1604  Figure
1605 1605  
1606 -[[image:image-20220831170306-4.png]][[image:image-20220831170254-3.png]]
1467 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830174659-1.png?rev=1.1||alt="image-20220830174659-1.png"]]
1607 1607  
1608 1608  Pin Definition Diagram
1609 1609  
1610 -[[image:image-20220831170215-2.png]]
1471 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830173402-8.png?rev=1.1||alt="image-20220830173402-8.png"]]
1611 1611  
1612 -== **XGK FEnet Ethernet protocol** ==
1473 +== **XGK FEnet Ethernet protocol**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=43]] ==
1613 1613  
1614 1614  Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module
1615 1615  
1616 -**1)V-BOX Settings**
1477 +**HMI Settings**
1617 1617  
1618 1618  |**Items**|**Settings**|**Note**
1619 1619  |Protocol|LG XGK FEnet(Ethernet)|
... ... @@ -1620,7 +1620,7 @@
1620 1620  |Connection|Ethernet|
1621 1621  |Port No.|2004|
1622 1622  
1623 -**2)Address List**
1484 +**Address List**
1624 1624  
1625 1625  |**Type**|**Register**|**Range**|**Format**|**Note**
1626 1626  |(% rowspan="14" %)Word|P|0~~2047|P d|
... ... @@ -1644,18 +1644,186 @@
1644 1644  * The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC;
1645 1645  * All bit registers are in the form of bits in word, and the range is the same as the word register;
1646 1646  
1647 -**3)Communication Settings**
1508 +**Communication settings in HMI**
1648 1648  
1649 -[[image:image-20220831171127-1.png]]
1510 +Enable HMI Ethernet in [Project Settings];
1650 1650  
1651 -**4)Cable Wiring**
1512 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_43b671f18153910d.png?width=405&height=107&rev=1.1||alt="12.PLC Protocol_html_43b671f18153910d.png" height="107" width="405"]]
1652 1652  
1514 +Set PLC IP in [Device IP] settings;
1515 +
1516 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_a2a19b5003ad4090.png?width=554&height=189&rev=1.1||alt="12.PLC Protocol_html_a2a19b5003ad4090.png" height="189" width="554"]]
1517 +
1518 +**Cable Wiring**
1519 +
1653 1653  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1654 1654  
1655 -= Create communication with **Modbus ** =
1522 += Create communication with **SHIMADEN PLC**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=44]] =
1656 1656  
1657 -== **MODBUS RTU Slave (All function)** ==
1524 +== **FP23 series protocol**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=45]] ==
1658 1658  
1526 +Supported series: SHIMADEN FP23 series
1527 +
1528 +**HMI Setting**
1529 +
1530 +|**Items**|**Settings**|**Note**
1531 +|Protocol|SHIMADEN FP23 series|
1532 +|Connection|RS485 (9600, 1, 7, EVEN)|
1533 +|Port No.|None|
1534 +|PLC station No.|0|
1535 +
1536 +**Address List**
1537 +
1538 +|**Device address**|**HMI register**|**Address range**|**Type**
1539 +|0040-0043(HEX)|FP040|100064-200067|Read only
1540 +|0100-010B(HEX)|FP100|100256-200267|Read only
1541 +|0110-0142(HEX)|FP110|100272-200322|Read only
1542 +|0182-0252(HEX)|FP182|100386-200594|Write only
1543 +|0280-0281(HEX)|FP280|100640-200641|Read only
1544 +|0300-030B(HEX)|FP300|100768-200779|Read and write
1545 +|0380-039F(HEX)|FP380|100896-200927|Read and write
1546 +|0400-04D7(HEX)|FP400|101024-201239|Read and write
1547 +|0500-05B0(HEX)|FP500|101280-201456|Read and write
1548 +|0600-0670(HEX)|FP600|101536-201814|Read and write
1549 +|0720-0738(HEX)|FP720|101824-201848|Read and write
1550 +|0800-083F(HEX)|FP800|102048-202111|Read and write
1551 +|0900-0952(HEX)|FP900|102304-202386|Read and write
1552 +| |Ctrl|0-2|
1553 +
1554 +**✎Note:**
1555 +
1556 +* The upper 2 bits of the address of the HMI register are taken as the sub address, and the real address is the last four bits (for example, if the address is 100256, then 10 is the sub address as 1, and 0256 is the real address);
1557 +* The address range in the table is only divided by the start and end addresses, and some of the addresses in the range have no corresponding address in FP23;
1558 +* The Ctrl register is used to store the control group number and BCC check mode.
1559 +
1560 +**Ctrl Register Description**
1561 +
1562 +* The Ctrl register is a special register that does not communicate with the temperature controller. User needs to assign value in the screen according to the settings as in the temperature controller.
1563 +* Ctrl0 indicates the setting of the control character, the valid values are 1, 2, 3 respectively, and the corresponding control group is: STX_ETX_CR , STX_ETX_CR LF and @_:_CR .
1564 +* Ctrl1 indicates the BCC block check mode. The valid value range is 1-4. The corresponding check mode is: 1.ADD, 2.ADD_two's cmp, 3.XOR, 4.None;
1565 +* Ctrl3 reserved
1566 +
1567 +**✎Note:**
1568 +
1569 +After reloading the HMI project or restarting the HMI, HMI will reset the value of ctrl0 and ctrl1 as 1, so user need to set these two values to make it the same as it in the temperature controller, then communication will be normal.
1570 +
1571 +**Cable Wiring**
1572 +
1573 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5e9a81a14106da9e.png?width=392&height=223&rev=1.1||alt="12.PLC Protocol_html_5e9a81a14106da9e.png" height="223" width="392"]]
1574 +
1575 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_1897d92be6948d58.png?width=393&height=223&rev=1.1||alt="12.PLC Protocol_html_1897d92be6948d58.png" height="223" width="393"]]
1576 +
1577 +**✎Note:** COM3 only available in PI8000/PI9000 series.
1578 +
1579 +== **SR90 protocol**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=46]] ==
1580 +
1581 +Supported series: SHIMADEN SR90 series
1582 +
1583 +**HMI Setting**
1584 +
1585 +|**Items**|**Settings**|**Note**
1586 +|Protocol|SHIMADEN SR90 protocol|
1587 +|Connection|RS485 (1200, 1, 7, EVEN)|
1588 +|Port No.|None|
1589 +|PLC station No.|0|
1590 +
1591 +**Address List**
1592 +
1593 +|**Device address**|**HMI register**|**Address range**|**Type**
1594 +|0040-0043 (HEX)|SR040|100064-100067|Read only
1595 +|0100-010A(HEX)|SR0100|100256-100266|Read only
1596 +|0182-018C(HEX)|SR0182|100386-100396|Write only
1597 +|0300-04FE(HEX)|SR0300|100768-101278|Write/read
1598 +|0500-050B(HEX)|SR0500|101280-101291|Write/read
1599 +|0590-0611(HEX)|SR0590|101424-101553|Write/read
1600 +|0701-0709(HEX)|SR0701|101793-101801|Write/read
1601 +| |Ctrl|0-2|~-~-
1602 +
1603 +**✎Note:**
1604 +
1605 +* The upper 2 bits of the address of HMIs are taken as the sub address, and the real address is the last four bits (for example, if the address is 100256, then 10 is the sub address as 1, and 0256 is the real address);
1606 +* The address range in the table is only divided by the start and end addresses, and some of the addresses in the range have no corresponding address in SR90;
1607 +* The Ctrl register is used to store the control group number and BCC check mode. See how to use it below;
1608 +
1609 +**Ctrl Register Description**
1610 +
1611 +* The Ctrl register is a special register that does not communicate with the temperature controller. User needs to assign value in the screen according to the settings as in the temperature controller.
1612 +* Ctrl0 indicates the setting of the control character, the valid values are 1, 2, 3 respectively, and the corresponding control group is: STX_ETX_CR , STX_ETX_CR LF and @_:_CR .
1613 +* Ctrl1 indicates the BCC block check mode. The valid value range is 1-4. The corresponding check mode is: 1.ADD, 2.ADD_two's cmp, 3.XOR, 4.None;
1614 +* Ctrl3 reserved
1615 +
1616 +**✎Note:**
1617 +
1618 +After reloading the HMI project or restarting the HMI, HMI will reset the value of ctrl0 and ctrl1 as 1, so user need to set these two values to make it the same as it in the temperature controller, then communication will be normal.
1619 +
1620 +**Cable Wiring**
1621 +
1622 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5e9a81a14106da9e.png?width=392&height=223&rev=1.1||alt="12.PLC Protocol_html_5e9a81a14106da9e.png" height="223" width="392"]]
1623 +
1624 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_1897d92be6948d58.png?width=393&height=223&rev=1.1||alt="12.PLC Protocol_html_1897d92be6948d58.png" height="223" width="393"]]
1625 +
1626 +**✎Note:** COM3 only available in PI8000/PI9000 series.
1627 +
1628 +== **MR13 series(standard protocol)**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=47]] ==
1629 +
1630 +Supported series: SHIMADEN MR13 series
1631 +
1632 +**HMI Setting**
1633 +
1634 +|**Items**|**Settings**|**Note**
1635 +|Protocol|SHIMADEN standard protocol|
1636 +|Connection|RS485 (1200, 1, 7, EVEN)|
1637 +|Port No.|None|
1638 +|PLC station No.|0|
1639 +
1640 +**Address List**
1641 +
1642 +|**Device address**|**HMI register**|**Address range**|**Type**
1643 +|0100-010B(HEX)|MR100|100256-300267|Read only
1644 +|0111-0126(HEX)|MR111|100273-300294|Read only
1645 +|0184-0192(HEX)|MR184|100388-300402|Write only
1646 +|0280-0282(HEX)|MR280|100640-300642|Read only
1647 +|0300-030B(HEX)|MR300|100768-300779|Read/write
1648 +|0314-0317(HEX)|MR314|100788-300791|Read/write
1649 +|031A(HEX)|MR31A|100794-300794|Read/write
1650 +|0320-0321(HEX)|MR320|100800-300801|Read/write
1651 +|0400-0504(HEX)|MR400|101024-301284|Read/write
1652 +|0506(HEX)|MR506|101286-301286|Read/write
1653 +|0510-0514(HEX)|MR510|101296-301300|Read/write
1654 +|0516-0524(HEX)|MR516|101302-301316|Read/write
1655 +|0526(HEX)|MR526|101318-301318|Read/write
1656 +|0580-08C3(HEX)|MR580|101408-302243|Read/write
1657 +|~-~-|Ctrl|0-2|~-~-
1658 +
1659 +**✎Note:**
1660 +
1661 +* The upper 2 bits of the address of the HMI register are taken as the sub address, and the real address is the last four bits (for example, if the address is 100256, then 10 is the sub address as 1, and 0256 is the real address);
1662 +* The address range in the table is only divided by the start and end addresses, and some of the addresses in the range have no corresponding address in MR13;
1663 +* The Ctrl register is used to store the control group number and BCC check mode.
1664 +
1665 +**Ctrl Register Description**
1666 +
1667 +* The Ctrl register is a special register that does not communicate with the temperature controller. User needs to assign value in the screen according to the settings as in the temperature controller.
1668 +* Ctrl0 indicates the setting of the control character, the valid values are 1, 2, 3 respectively, and the corresponding control group is: STX_ETX_CR, STX_ETX_CR LF and @_:_CR .
1669 +* Ctrl1 indicates the BCC block check mode. The valid value range is 1-4. The corresponding check mode is: 1.ADD, 2.ADD_two's cmp, 3.XOR, 4.None;
1670 +* Ctrl3 reserved
1671 +
1672 +**✎Note:**
1673 +
1674 +After reloading project or restarting the HMI, HMI will reset the value of ctrl0 and ctrl1 as 1, so user need to set these two values to make it the same as it in the temperature controller, then communication will be normal.
1675 +
1676 +**Cable Wiring**
1677 +
1678 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5e9a81a14106da9e.png?width=392&height=223&rev=1.1||alt="12.PLC Protocol_html_5e9a81a14106da9e.png" height="223" width="392"]]
1679 +
1680 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_1897d92be6948d58.png?width=393&height=223&rev=1.1||alt="12.PLC Protocol_html_1897d92be6948d58.png" height="223" width="393"]]
1681 +
1682 +**✎Note:** COM3 only available in PI8000/PI9000 series.
1683 +
1684 += Create communication with **Modbus RTU** =
1685 +
1686 +== **V-BOX as Slave** ==
1687 +
1659 1659  Select the protocol "Modbus RTU Slave (All Fuction)",
1660 1660  
1661 1661  Then set baud rate, port, stop bits, data bits, parity.
... ... @@ -1663,7 +1663,7 @@
1663 1663  (% style="text-align:center" %)
1664 1664  [[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]]
1665 1665  
1666 -== **MODBUS RTU Master** ==
1695 +== **V-BOX as Master** ==
1667 1667  
1668 1668  Select the protocol "Modbus RTU Master",
1669 1669  
... ... @@ -1699,61 +1699,6 @@
1699 1699  |(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils)
1700 1700  |0F (Write multiple bits)
1701 1701  
1702 -== **MODBUS TCP Slave (All function)** ==
1703 -
1704 -Supported series: MODBUS TCP controller
1705 -
1706 -V-B0X works as MODBUS TCP MASTER connecting with TCP SLAVE
1707 -
1708 -**1)V-BOX Setting**
1709 -
1710 -|**Items**|**Settings**|**Note**
1711 -|Protocol|MODBUS TCP Slave (All function)|
1712 -|Connection|Ethernet|
1713 -|Port No.|502|
1714 -|PLC station No.|1
1715 -
1716 -**2)Address List**
1717 -
1718 -|**Type**|**Register**|**Function code & Description**
1719 -|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers)
1720 -|06 (write single register: write a binary value to a holding register)
1721 -|10 (write values to multiple addresses )
1722 -|(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers)
1723 -|06 (write single register: write a binary value to a holding register)
1724 -|10 (write values to multiple addresses )
1725 -|(% rowspan="3" %)W6|03 (read holding register: read current binary value in one or more holding registers)
1726 -|06 (write single register: write a binary value to a holding register)
1727 -|10 (write values to multiple addresses )
1728 -|(% rowspan="2" %)W16|03 (read holding register: read current binary value in one or more holding registers)
1729 -|10 (write values to multiple addresses )
1730 -|(% rowspan="11" %)Bit|(% rowspan="3" %)0|01 (Read coil state)
1731 -|05 (Force a single coil to force the on/off state of a logic coil)
1732 -|0F (Write multiple bits, ie write continuously)
1733 -|(% rowspan="3" %)1|02 (Read the input state)
1734 -|05 (Force a single coil to force the on/off state of a logic coil)
1735 -|0F (Write multiple bits)
1736 -|(% rowspan="3" %)W5|01 (Read coil state to obtain the current state of a set of logic coils)
1737 -|05 (Force a single coil to force the on/off state of a logic coil)
1738 -|0F (Write multiple bits)
1739 -|(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils)
1740 -|0F (Write multiple bits)
1741 -
1742 -**3)Communication Settings**
1743 -
1744 -Configure V-BOX Ethernet IP in Networking Settings
1745 -
1746 -[[image:image-20220902111833-3.png]]
1747 -
1748 -
1749 -Configure PLC Ethernet IP in Communication;
1750 -
1751 -[[image:image-20220902111121-1.png]]
1752 -
1753 -**4)Cable Wiring**
1754 -
1755 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1756 -
1757 1757  == **communicate with VB inverter** ==
1758 1758  
1759 1759  [[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20VB%20inverter.zip]]
image-20220831164626-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -56.1 KB
Content
image-20220831164646-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -28.4 KB
Content
image-20220831164700-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -66.6 KB
Content
image-20220831164731-4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -12.3 KB
Content
image-20220831165008-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -13.3 KB
Content
image-20220831165017-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -36.2 KB
Content
image-20220831165031-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -28.3 KB
Content
image-20220831165238-4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -57.4 KB
Content
image-20220831170147-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -57.1 KB
Content
image-20220831170215-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -14.3 KB
Content
image-20220831170254-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -43.5 KB
Content
image-20220831170306-4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -28.5 KB
Content
image-20220831171127-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -60.1 KB
Content
image-20220902104329-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -58.7 KB
Content
image-20220902111121-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -60.9 KB
Content
image-20220902111754-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -57.6 KB
Content
image-20220902111833-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -56.1 KB
Content