Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 4 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki.B ob1 +XWiki.Ben - Content
-
... ... @@ -182,7 +182,7 @@ 182 182 183 183 MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 184 184 185 -**1) V-BOXsetting**185 +**1)PLC Settings** 186 186 187 187 |**Item**|**Settings**|**Note** 188 188 |Protocol|Allen-Bradlley DF1 Advanced| ... ... @@ -436,7 +436,7 @@ 436 436 437 437 Supported Series: Siemens S7-300 series PLC 438 438 439 -**1) V-BOXsetting**439 +**1)PLC Setting** 440 440 441 441 |**Items**|**Settings**|**Note** 442 442 |Protocol|Simens S7-300 Ethernet| ... ... @@ -498,7 +498,7 @@ 498 498 499 499 Supported Series: Siemens S7-400, S7-1200 and S7-1500 500 500 501 -**1) V-BOXsetting**501 +**1)PLC Setting** 502 502 503 503 |=**Items**|=**Settings**|=**Note** 504 504 |Protocol|Siemens S7-XXX| ... ... @@ -704,112 +704,6 @@ 704 704 [[image:image-20220825100845-4.png]] 705 705 706 706 707 -== **FX3U Ethernet Protocol** == 708 - 709 - Mitsubishi FX3U series PLC 710 - 711 -**HMI Settings** 712 - 713 -|Items|Settings|Note 714 -|Protocol|Mitsubishi FX3U| 715 -|Connection|Ethernet| 716 -|Port No.|5009|Must be the same as the PLC setting 717 -|PLC station No.|0| 718 - 719 -**Address List** 720 - 721 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 722 -|(% colspan="1" rowspan="7" %)Bit|X|X|X OOO|0~~377| 723 -|Y|Y|Y OOO|0~~377| 724 -|M|M|M DDDD|0~~7679| 725 -|SM|SM|SM DDDD|8000~~8511| 726 -|S|S|S DDDD|0~~4095| 727 -|TS|TS|TS DDD|0~~511| 728 -|CS|CS|CS DDD|0~~255| 729 -|(% colspan="1" rowspan="9" %)Word|CN|CN|CN DDD|0~~199| 730 -|TN|TN|TN DDD|0~~511| 731 -|D|D|D DDDD|0~~7999| 732 -|SD|SD|SD DDDD|8000~~8511| 733 -|R|R|R DDDDD|0~~32767| 734 - 735 -**Ethernet Module Settings** 736 - 737 -FX3U-ENET-L module configuration 738 -Set up the FX3U-ENET-L Ethernet module settings as follows. 739 -Select the module location, which in this document is Module 0. 740 - 741 -[[image:image-20221116094003-1.png]] 742 - 743 - 744 -Select "Operational setting" to enter the following screen. 745 - 746 -The Ethernet module IP is set to 192.168.39.254 in this document, and other options are default. 747 - 748 -[[image:image-20221116094019-2.png]] 749 - 750 - 751 -Select "Open setting" to enter the setting interface, the settings are as follows. 752 - 753 -The third item "Protocol" selects TCP, and "Open system" selects MELSOFT connection, which allows the 754 - 755 -Mitsubishi programming software GX works2 to communicate with the FX3U via the Ethernet module. 756 - 757 -[[image:image-20221116094038-3.png]] 758 - 759 - 760 -Click on "transter setup" - "PC side I/F setting", see the following figure. 761 - 762 -After setting, the first download must use the programming cable, as shown in the figure; after that, can 763 - 764 -use the IP set in the "Ethernet board" to communicate directly with the network cable. 765 - 766 -[[image:image-20221116094122-4.png||height="422" width="707"]] 767 - 768 - 769 -Read and write data from the Ethernet module 770 - 771 -[[image:image-20221116094131-5.png||height="551" width="708"]] 772 - 773 - 774 -Set "Transter setup" to COM communication, and read or write operation as shown below 775 - 776 -[[image:image-20221116094150-6.png]] 777 - 778 - 779 -**PLC Settings (GX Works 2)** 780 - 781 -Create a blank FX5U project 782 - 783 -Find Current Connection in the navigation 784 - 785 -[[image:image-20221116094206-7.png||height="425" width="711"]] 786 - 787 - 788 -Select Connection Channel List 789 - 790 -Select Ethernet board communication 791 - 792 -[[image:image-20221116094709-9.png||height="427" width="715"]] 793 - 794 - 795 -Select Ethernet Module 796 -Set the IP address of the PLC 797 - 798 -[[image:image-20221116094736-11.png||height="682" width="716"]] 799 - 800 - 801 -Read or write PLC data, in this document is read 802 - 803 -[[image:image-20221116094755-12.png||height="426" width="715"]] 804 - 805 -[[image:image-20221116094803-13.png||height="427" width="715"]] 806 - 807 -**V-BOX Communication Setting** 808 - 809 - 810 - 811 - 812 - 813 813 == **FX5U Serial Protocol** == 814 814 815 815 Mitsubishi FX5U series PLC ... ... @@ -1418,41 +1418,6 @@ 1418 1418 1419 1419 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830160232-3.png?rev=1.1||alt="image-20220830160232-3.png"]] 1420 1420 1421 - 1422 -= Create communication with **Schneider PLC** = 1423 - 1424 -== **Schneider MODBUS RTU** == 1425 - 1426 -**1)V-BOX Setting** 1427 - 1428 -|=**Parameters**|=**Recommended**|=**Notes** 1429 -|**Protocol**|(% colspan="1" %)Schneider MODBUS RTU| 1430 -|**Connection**|RS485| 1431 -|**Baud rate**|19200| 1432 -|**Data bit**|8| 1433 -|**Parity**|Even| 1434 -|**Stop bit**|1| 1435 -|**PLC station No.**|1| 1436 - 1437 -**2)Address List** 1438 - 1439 -|=**Bit/Word**|=**Device type**|=**Format**|=**Range**|=**Memo** 1440 -|B|IX|DDDDDo|0 ~~ 655357|Input bit (read only) 1441 -|B|QX|DDDDDo|0 ~~ 655357|Write multiple coils 1442 -|B|MX|DDDDDDo|0 ~~ 9999997|Output register bit (octal) 1443 -|W|MW|DDDDDD|0 ~~ 999999|Output register 1444 -|DW|MD|DDDDDD|0 ~~ 999999|Output register 1445 - 1446 -**3)Configure the communication protocol** 1447 - 1448 -[[image:image-20220902104329-1.png]] 1449 - 1450 -**4)Cable Wiring** 1451 - 1452 -**RS-485 2W **(RJ45 Connector): The following is the view from the soldering point of a connector. 1453 - 1454 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220817154212-1.jpeg?width=554&height=315&rev=1.1||alt="image-20220817154212-1.jpeg" height="315" width="554"]] 1455 - 1456 1456 = Create communication with Inovance** PLC** = 1457 1457 1458 1458 == **H3U serial protocol** == ... ... @@ -1652,10 +1652,172 @@ 1652 1652 1653 1653 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 1654 1654 1655 -= Create communication with **M odbus**=1514 += Create communication with **SHIMADEN PLC**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=44]] = 1656 1656 1657 -== ** MODBUSRTU Slave(All function)**==1516 +== **FP23 series protocol**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=45]] == 1658 1658 1518 +Supported series: SHIMADEN FP23 series 1519 + 1520 +**HMI Setting** 1521 + 1522 +|**Items**|**Settings**|**Note** 1523 +|Protocol|SHIMADEN FP23 series| 1524 +|Connection|RS485 (9600, 1, 7, EVEN)| 1525 +|Port No.|None| 1526 +|PLC station No.|0| 1527 + 1528 +**Address List** 1529 + 1530 +|**Device address**|**HMI register**|**Address range**|**Type** 1531 +|0040-0043(HEX)|FP040|100064-200067|Read only 1532 +|0100-010B(HEX)|FP100|100256-200267|Read only 1533 +|0110-0142(HEX)|FP110|100272-200322|Read only 1534 +|0182-0252(HEX)|FP182|100386-200594|Write only 1535 +|0280-0281(HEX)|FP280|100640-200641|Read only 1536 +|0300-030B(HEX)|FP300|100768-200779|Read and write 1537 +|0380-039F(HEX)|FP380|100896-200927|Read and write 1538 +|0400-04D7(HEX)|FP400|101024-201239|Read and write 1539 +|0500-05B0(HEX)|FP500|101280-201456|Read and write 1540 +|0600-0670(HEX)|FP600|101536-201814|Read and write 1541 +|0720-0738(HEX)|FP720|101824-201848|Read and write 1542 +|0800-083F(HEX)|FP800|102048-202111|Read and write 1543 +|0900-0952(HEX)|FP900|102304-202386|Read and write 1544 +| |Ctrl|0-2| 1545 + 1546 +**✎Note:** 1547 + 1548 +* The upper 2 bits of the address of the HMI register are taken as the sub address, and the real address is the last four bits (for example, if the address is 100256, then 10 is the sub address as 1, and 0256 is the real address); 1549 +* The address range in the table is only divided by the start and end addresses, and some of the addresses in the range have no corresponding address in FP23; 1550 +* The Ctrl register is used to store the control group number and BCC check mode. 1551 + 1552 +**Ctrl Register Description** 1553 + 1554 +* The Ctrl register is a special register that does not communicate with the temperature controller. User needs to assign value in the screen according to the settings as in the temperature controller. 1555 +* Ctrl0 indicates the setting of the control character, the valid values are 1, 2, 3 respectively, and the corresponding control group is: STX_ETX_CR , STX_ETX_CR LF and @_:_CR . 1556 +* Ctrl1 indicates the BCC block check mode. The valid value range is 1-4. The corresponding check mode is: 1.ADD, 2.ADD_two's cmp, 3.XOR, 4.None; 1557 +* Ctrl3 reserved 1558 + 1559 +**✎Note:** 1560 + 1561 +After reloading the HMI project or restarting the HMI, HMI will reset the value of ctrl0 and ctrl1 as 1, so user need to set these two values to make it the same as it in the temperature controller, then communication will be normal. 1562 + 1563 +**Cable Wiring** 1564 + 1565 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5e9a81a14106da9e.png?width=392&height=223&rev=1.1||alt="12.PLC Protocol_html_5e9a81a14106da9e.png" height="223" width="392"]] 1566 + 1567 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_1897d92be6948d58.png?width=393&height=223&rev=1.1||alt="12.PLC Protocol_html_1897d92be6948d58.png" height="223" width="393"]] 1568 + 1569 +**✎Note:** COM3 only available in PI8000/PI9000 series. 1570 + 1571 +== **SR90 protocol**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=46]] == 1572 + 1573 +Supported series: SHIMADEN SR90 series 1574 + 1575 +**HMI Setting** 1576 + 1577 +|**Items**|**Settings**|**Note** 1578 +|Protocol|SHIMADEN SR90 protocol| 1579 +|Connection|RS485 (1200, 1, 7, EVEN)| 1580 +|Port No.|None| 1581 +|PLC station No.|0| 1582 + 1583 +**Address List** 1584 + 1585 +|**Device address**|**HMI register**|**Address range**|**Type** 1586 +|0040-0043 (HEX)|SR040|100064-100067|Read only 1587 +|0100-010A(HEX)|SR0100|100256-100266|Read only 1588 +|0182-018C(HEX)|SR0182|100386-100396|Write only 1589 +|0300-04FE(HEX)|SR0300|100768-101278|Write/read 1590 +|0500-050B(HEX)|SR0500|101280-101291|Write/read 1591 +|0590-0611(HEX)|SR0590|101424-101553|Write/read 1592 +|0701-0709(HEX)|SR0701|101793-101801|Write/read 1593 +| |Ctrl|0-2|~-~- 1594 + 1595 +**✎Note:** 1596 + 1597 +* The upper 2 bits of the address of HMIs are taken as the sub address, and the real address is the last four bits (for example, if the address is 100256, then 10 is the sub address as 1, and 0256 is the real address); 1598 +* The address range in the table is only divided by the start and end addresses, and some of the addresses in the range have no corresponding address in SR90; 1599 +* The Ctrl register is used to store the control group number and BCC check mode. See how to use it below; 1600 + 1601 +**Ctrl Register Description** 1602 + 1603 +* The Ctrl register is a special register that does not communicate with the temperature controller. User needs to assign value in the screen according to the settings as in the temperature controller. 1604 +* Ctrl0 indicates the setting of the control character, the valid values are 1, 2, 3 respectively, and the corresponding control group is: STX_ETX_CR , STX_ETX_CR LF and @_:_CR . 1605 +* Ctrl1 indicates the BCC block check mode. The valid value range is 1-4. The corresponding check mode is: 1.ADD, 2.ADD_two's cmp, 3.XOR, 4.None; 1606 +* Ctrl3 reserved 1607 + 1608 +**✎Note:** 1609 + 1610 +After reloading the HMI project or restarting the HMI, HMI will reset the value of ctrl0 and ctrl1 as 1, so user need to set these two values to make it the same as it in the temperature controller, then communication will be normal. 1611 + 1612 +**Cable Wiring** 1613 + 1614 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5e9a81a14106da9e.png?width=392&height=223&rev=1.1||alt="12.PLC Protocol_html_5e9a81a14106da9e.png" height="223" width="392"]] 1615 + 1616 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_1897d92be6948d58.png?width=393&height=223&rev=1.1||alt="12.PLC Protocol_html_1897d92be6948d58.png" height="223" width="393"]] 1617 + 1618 +**✎Note:** COM3 only available in PI8000/PI9000 series. 1619 + 1620 +== **MR13 series(standard protocol)**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=47]] == 1621 + 1622 +Supported series: SHIMADEN MR13 series 1623 + 1624 +**HMI Setting** 1625 + 1626 +|**Items**|**Settings**|**Note** 1627 +|Protocol|SHIMADEN standard protocol| 1628 +|Connection|RS485 (1200, 1, 7, EVEN)| 1629 +|Port No.|None| 1630 +|PLC station No.|0| 1631 + 1632 +**Address List** 1633 + 1634 +|**Device address**|**HMI register**|**Address range**|**Type** 1635 +|0100-010B(HEX)|MR100|100256-300267|Read only 1636 +|0111-0126(HEX)|MR111|100273-300294|Read only 1637 +|0184-0192(HEX)|MR184|100388-300402|Write only 1638 +|0280-0282(HEX)|MR280|100640-300642|Read only 1639 +|0300-030B(HEX)|MR300|100768-300779|Read/write 1640 +|0314-0317(HEX)|MR314|100788-300791|Read/write 1641 +|031A(HEX)|MR31A|100794-300794|Read/write 1642 +|0320-0321(HEX)|MR320|100800-300801|Read/write 1643 +|0400-0504(HEX)|MR400|101024-301284|Read/write 1644 +|0506(HEX)|MR506|101286-301286|Read/write 1645 +|0510-0514(HEX)|MR510|101296-301300|Read/write 1646 +|0516-0524(HEX)|MR516|101302-301316|Read/write 1647 +|0526(HEX)|MR526|101318-301318|Read/write 1648 +|0580-08C3(HEX)|MR580|101408-302243|Read/write 1649 +|~-~-|Ctrl|0-2|~-~- 1650 + 1651 +**✎Note:** 1652 + 1653 +* The upper 2 bits of the address of the HMI register are taken as the sub address, and the real address is the last four bits (for example, if the address is 100256, then 10 is the sub address as 1, and 0256 is the real address); 1654 +* The address range in the table is only divided by the start and end addresses, and some of the addresses in the range have no corresponding address in MR13; 1655 +* The Ctrl register is used to store the control group number and BCC check mode. 1656 + 1657 +**Ctrl Register Description** 1658 + 1659 +* The Ctrl register is a special register that does not communicate with the temperature controller. User needs to assign value in the screen according to the settings as in the temperature controller. 1660 +* Ctrl0 indicates the setting of the control character, the valid values are 1, 2, 3 respectively, and the corresponding control group is: STX_ETX_CR, STX_ETX_CR LF and @_:_CR . 1661 +* Ctrl1 indicates the BCC block check mode. The valid value range is 1-4. The corresponding check mode is: 1.ADD, 2.ADD_two's cmp, 3.XOR, 4.None; 1662 +* Ctrl3 reserved 1663 + 1664 +**✎Note:** 1665 + 1666 +After reloading project or restarting the HMI, HMI will reset the value of ctrl0 and ctrl1 as 1, so user need to set these two values to make it the same as it in the temperature controller, then communication will be normal. 1667 + 1668 +**Cable Wiring** 1669 + 1670 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5e9a81a14106da9e.png?width=392&height=223&rev=1.1||alt="12.PLC Protocol_html_5e9a81a14106da9e.png" height="223" width="392"]] 1671 + 1672 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_1897d92be6948d58.png?width=393&height=223&rev=1.1||alt="12.PLC Protocol_html_1897d92be6948d58.png" height="223" width="393"]] 1673 + 1674 +**✎Note:** COM3 only available in PI8000/PI9000 series. 1675 + 1676 += Create communication with **Modbus RTU** = 1677 + 1678 +== **V-BOX as Slave** == 1679 + 1659 1659 Select the protocol "Modbus RTU Slave (All Fuction)", 1660 1660 1661 1661 Then set baud rate, port, stop bits, data bits, parity. ... ... @@ -1663,7 +1663,7 @@ 1663 1663 (% style="text-align:center" %) 1664 1664 [[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]] 1665 1665 1666 -== ** MODBUSRTUMaster** ==1687 +== **V-BOX as Master** == 1667 1667 1668 1668 Select the protocol "Modbus RTU Master", 1669 1669 ... ... @@ -1699,61 +1699,6 @@ 1699 1699 |(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils) 1700 1700 |0F (Write multiple bits) 1701 1701 1702 -== **MODBUS TCP Slave (All function)** == 1703 - 1704 -Supported series: MODBUS TCP controller 1705 - 1706 -V-B0X works as MODBUS TCP MASTER connecting with TCP SLAVE 1707 - 1708 -**1)V-BOX Setting** 1709 - 1710 -|**Items**|**Settings**|**Note** 1711 -|Protocol|MODBUS TCP Slave (All function)| 1712 -|Connection|Ethernet| 1713 -|Port No.|502| 1714 -|PLC station No.|1 1715 - 1716 -**2)Address List** 1717 - 1718 -|**Type**|**Register**|**Function code & Description** 1719 -|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers) 1720 -|06 (write single register: write a binary value to a holding register) 1721 -|10 (write values to multiple addresses ) 1722 -|(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers) 1723 -|06 (write single register: write a binary value to a holding register) 1724 -|10 (write values to multiple addresses ) 1725 -|(% rowspan="3" %)W6|03 (read holding register: read current binary value in one or more holding registers) 1726 -|06 (write single register: write a binary value to a holding register) 1727 -|10 (write values to multiple addresses ) 1728 -|(% rowspan="2" %)W16|03 (read holding register: read current binary value in one or more holding registers) 1729 -|10 (write values to multiple addresses ) 1730 -|(% rowspan="11" %)Bit|(% rowspan="3" %)0|01 (Read coil state) 1731 -|05 (Force a single coil to force the on/off state of a logic coil) 1732 -|0F (Write multiple bits, ie write continuously) 1733 -|(% rowspan="3" %)1|02 (Read the input state) 1734 -|05 (Force a single coil to force the on/off state of a logic coil) 1735 -|0F (Write multiple bits) 1736 -|(% rowspan="3" %)W5|01 (Read coil state to obtain the current state of a set of logic coils) 1737 -|05 (Force a single coil to force the on/off state of a logic coil) 1738 -|0F (Write multiple bits) 1739 -|(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils) 1740 -|0F (Write multiple bits) 1741 - 1742 -**3)Communication Settings** 1743 - 1744 -Configure V-BOX Ethernet IP in Networking Settings 1745 - 1746 -[[image:image-20220902111833-3.png]] 1747 - 1748 - 1749 -Configure PLC Ethernet IP in Communication; 1750 - 1751 -[[image:image-20220902111121-1.png]] 1752 - 1753 -**4)Cable Wiring** 1754 - 1755 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 1756 - 1757 1757 == **communicate with VB inverter** == 1758 1758 1759 1759 [[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20VB%20inverter.zip]]
- image-20220902104329-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -58.7 KB - Content
- image-20220902111121-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -60.9 KB - Content
- image-20220902111754-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -57.6 KB - Content
- image-20220902111833-3.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -56.1 KB - Content