... ... @@ -1,1 +1,1 @@
1 -XWiki.Bob
1 +XWiki.Ben
Content
... ... @@ -704,112 +704,6 @@
704 704  [[image:image-20220825100845-4.png]]
705 705  
706 706  
707 -== **FX3U Ethernet Protocol** ==
708 -
709 - Mitsubishi FX3U series PLC
710 -
711 -**HMI Settings**
712 -
713 -|Items|Settings|Note
714 -|Protocol|Mitsubishi FX3U|
715 -|Connection|Ethernet|
716 -|Port No.|5009|Must be the same as the PLC setting
717 -|PLC station No.|0|
718 -
719 -**Address List**
720 -
721 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
722 -|(% colspan="1" rowspan="7" %)Bit|X|X|X OOO|0~~377|
723 -|Y|Y|Y OOO|0~~377|
724 -|M|M|M DDDD|0~~7679|
725 -|SM|SM|SM DDDD|8000~~8511|
726 -|S|S|S DDDD|0~~4095|
727 -|TS|TS|TS DDD|0~~511|
728 -|CS|CS|CS DDD|0~~255|
729 -|(% colspan="1" rowspan="9" %)Word|CN|CN|CN DDD|0~~199|
730 -|TN|TN|TN DDD|0~~511|
731 -|D|D|D DDDD|0~~7999|
732 -|SD|SD|SD DDDD|8000~~8511|
733 -|R|R|R DDDDD|0~~32767|
734 -
735 -**Ethernet Module Settings**
736 -
737 -FX3U-ENET-L module configuration
738 -Set up the FX3U-ENET-L Ethernet module settings as follows.
739 -Select the module location, which in this document is Module 0.
740 -
741 -[[image:image-20221116094003-1.png]]
742 -
743 -
744 -Select "Operational setting" to enter the following screen.
745 -
746 -The Ethernet module IP is set to 192.168.39.254 in this document, and other options are default.
747 -
748 -[[image:image-20221116094019-2.png]]
749 -
750 -
751 -Select "Open setting" to enter the setting interface, the settings are as follows.
752 -
753 -The third item "Protocol" selects TCP, and "Open system" selects MELSOFT connection, which allows the
754 -
755 -Mitsubishi programming software GX works2 to communicate with the FX3U via the Ethernet module.
756 -
757 -[[image:image-20221116094038-3.png]]
758 -
759 -
760 -Click on "transter setup" - "PC side I/F setting", see the following figure.
761 -
762 -After setting, the first download must use the programming cable, as shown in the figure; after that, can
763 -
764 -use the IP set in the "Ethernet board" to communicate directly with the network cable.
765 -
766 -[[image:image-20221116094122-4.png||height="422" width="707"]]
767 -
768 -
769 -Read and write data from the Ethernet module
770 -
771 -[[image:image-20221116094131-5.png||height="551" width="708"]]
772 -
773 -
774 -Set "Transter setup" to COM communication, and read or write operation as shown below
775 -
776 -[[image:image-20221116094150-6.png]]
777 -
778 -
779 -**PLC Settings (GX Works 2)**
780 -
781 -Create a blank FX5U project
782 -
783 -Find Current Connection in the navigation
784 -
785 -[[image:image-20221116094206-7.png||height="425" width="711"]]
786 -
787 -
788 -Select Connection Channel List
789 -
790 -Select Ethernet board communication
791 -
792 -[[image:image-20221116094709-9.png||height="427" width="715"]]
793 -
794 -
795 -Select Ethernet Module
796 -Set the IP address of the PLC
797 -
798 -[[image:image-20221116094736-11.png||height="682" width="716"]]
799 -
800 -
801 -Read or write PLC data, in this document is read
802 -
803 -[[image:image-20221116094755-12.png||height="426" width="715"]]
804 -
805 -[[image:image-20221116094803-13.png||height="427" width="715"]]
806 -
807 -**V-BOX Communication Setting**
808 -
809 -
810 -
811 -
812 -
813 813  == **FX5U Serial Protocol** ==