... ... @@ -1,1 +1,1 @@
1 -XWiki.Bob
1 +XWiki.Ben
Content
... ... @@ -182,7 +182,7 @@
182 182  
183 183  MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
184 184  
185 -**1)V-BOX setting**
185 +**1)PLC Settings**
186 186  
187 187  |**Item**|**Settings**|**Note**
188 188  |Protocol|Allen-Bradlley DF1 Advanced|
... ... @@ -436,7 +436,7 @@
436 436  
437 437  Supported Series: Siemens S7-300 series PLC
438 438  
439 -**1)V-BOX setting**
439 +**1)PLC Setting**
440 440  
441 441  |**Items**|**Settings**|**Note**
442 442  |Protocol|Simens S7-300 Ethernet|
... ... @@ -498,7 +498,7 @@
498 498  
499 499  Supported Series: Siemens S7-400, S7-1200 and S7-1500
500 500  
501 -**1)V-BOX setting**
501 +**1)PLC Setting**
502 502  
503 503  |=**Items**|=**Settings**|=**Note**
504 504  |Protocol|Siemens S7-XXX|
... ... @@ -704,112 +704,6 @@
704 704  [[image:image-20220825100845-4.png]]
705 705  
706 706  
707 -== **FX3U Ethernet Protocol** ==
708 -
709 - Mitsubishi FX3U series PLC
710 -
711 -**HMI Settings**
712 -
713 -|Items|Settings|Note
714 -|Protocol|Mitsubishi FX3U|
715 -|Connection|Ethernet|
716 -|Port No.|5009|Must be the same as the PLC setting
717 -|PLC station No.|0|
718 -
719 -**Address List**
720 -
721 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
722 -|(% colspan="1" rowspan="7" %)Bit|X|X|X OOO|0~~377|
723 -|Y|Y|Y OOO|0~~377|
724 -|M|M|M DDDD|0~~7679|
725 -|SM|SM|SM DDDD|8000~~8511|
726 -|S|S|S DDDD|0~~4095|
727 -|TS|TS|TS DDD|0~~511|
728 -|CS|CS|CS DDD|0~~255|
729 -|(% colspan="1" rowspan="9" %)Word|CN|CN|CN DDD|0~~199|
730 -|TN|TN|TN DDD|0~~511|
731 -|D|D|D DDDD|0~~7999|
732 -|SD|SD|SD DDDD|8000~~8511|
733 -|R|R|R DDDDD|0~~32767|
734 -
735 -**Ethernet Module Settings**
736 -
737 -FX3U-ENET-L module configuration
738 -Set up the FX3U-ENET-L Ethernet module settings as follows.
739 -Select the module location, which in this document is Module 0.
740 -
741 -[[image:image-20221116094003-1.png]]
742 -
743 -
744 -Select "Operational setting" to enter the following screen.
745 -
746 -The Ethernet module IP is set to 192.168.39.254 in this document, and other options are default.
747 -
748 -[[image:image-20221116094019-2.png]]
749 -
750 -
751 -Select "Open setting" to enter the setting interface, the settings are as follows.
752 -
753 -The third item "Protocol" selects TCP, and "Open system" selects MELSOFT connection, which allows the
754 -
755 -Mitsubishi programming software GX works2 to communicate with the FX3U via the Ethernet module.
756 -
757 -[[image:image-20221116094038-3.png]]
758 -
759 -
760 -Click on "transter setup" - "PC side I/F setting", see the following figure.
761 -
762 -After setting, the first download must use the programming cable, as shown in the figure; after that, can
763 -
764 -use the IP set in the "Ethernet board" to communicate directly with the network cable.
765 -
766 -[[image:image-20221116094122-4.png||height="422" width="707"]]
767 -
768 -
769 -Read and write data from the Ethernet module
770 -
771 -[[image:image-20221116094131-5.png||height="551" width="708"]]
772 -
773 -
774 -Set "Transter setup" to COM communication, and read or write operation as shown below
775 -
776 -[[image:image-20221116094150-6.png]]
777 -
778 -
779 -**PLC Settings (GX Works 2)**
780 -
781 -Create a blank FX5U project
782 -
783 -Find Current Connection in the navigation
784 -
785 -[[image:image-20221116094206-7.png||height="425" width="711"]]
786 -
787 -
788 -Select Connection Channel List
789 -
790 -Select Ethernet board communication
791 -
792 -[[image:image-20221116094709-9.png||height="427" width="715"]]
793 -
794 -
795 -Select Ethernet Module
796 -Set the IP address of the PLC
797 -
798 -[[image:image-20221116094736-11.png||height="682" width="716"]]
799 -
800 -
801 -Read or write PLC data, in this document is read
802 -
803 -[[image:image-20221116094755-12.png||height="426" width="715"]]
804 -
805 -[[image:image-20221116094803-13.png||height="427" width="715"]]
806 -
807 -**V-BOX Communication Setting**
808 -
809 -
810 -
811 -
812 -
813 813  == **FX5U Serial Protocol** ==
814 814  
815 815  Mitsubishi FX5U series PLC
... ... @@ -964,10 +964,11 @@
964 964  
965 965  [[image:image-20220825112403-1.png||alt="图片-20220825112403-1.png"]]
966 966  
967 -**5)Cable Wiring**
861 +**5)电缆布线**
968 968  
969 969  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
970 970  
865 +
971 971  == **L02 Serial Protocol** ==
972 972  
973 973  Mitsubishi L02 series CPU built-in serial port.
... ... @@ -1417,41 +1417,6 @@
1417 1417  
1418 1418  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830160232-3.png?rev=1.1||alt="image-20220830160232-3.png"]]
1419 1419  
1420 -
1421 -= Create communication with **Schneider PLC** =
1422 -
1423 -== **Schneider MODBUS RTU** ==
1424 -
1425 -**1)V-BOX Setting**
1426 -
1427 -|=**Parameters**|=**Recommended**|=**Notes**
1428 -|**Protocol**|(% colspan="1" %)Schneider MODBUS RTU|
1429 -|**Connection**|RS485|
1430 -|**Baud rate**|19200|
1431 -|**Data bit**|8|
1432 -|**Parity**|Even|
1433 -|**Stop bit**|1|
1434 -|**PLC station No.**|1|
1435 -
1436 -**2)Address List**
1437 -
1438 -|=**Bit/Word**|=**Device type**|=**Format**|=**Range**|=**Memo**
1439 -|B|IX|DDDDDo|0 ~~ 655357|Input bit (read only)
1440 -|B|QX|DDDDDo|0 ~~ 655357|Write multiple coils
1441 -|B|MX|DDDDDDo|0 ~~ 9999997|Output register bit (octal)
1442 -|W|MW|DDDDDD|0 ~~ 999999|Output register
1443 -|DW|MD|DDDDDD|0 ~~ 999999|Output register
1444 -
1445 -**3)Configure the communication protocol**
1446 -
1447 -[[image:image-20220902104329-1.png]]
1448 -
1449 -**4)Cable Wiring**
1450 -
1451 -**RS-485 2W **(RJ45 Connector): The following is the view from the soldering point of a connector.
1452 -
1453 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220817154212-1.jpeg?width=554&height=315&rev=1.1||alt="image-20220817154212-1.jpeg" height="315" width="554"]]
1454 -
1455 1455  = Create communication with Inovance** PLC** =
1456 1456  
1457 1457  == **H3U serial protocol** ==
... ... @@ -1504,11 +1504,11 @@
1504 1504  
1505 1505  [[image:image-20220831164731-4.png]]
1506 1506  
1507 -= Create communication with Panasonic** PLC** =
1367 += Create communication with Panasonic** PLC**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=39]] =
1508 1508  
1509 -== **FP serial protocol** ==
1369 +== **FP serial protocol**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=40]] ==
1510 1510  
1511 -**1)V-BOX Settings**
1371 +**1)HMI Settings**
1512 1512  
1513 1513  |**Item**|**Settings**|**Note**
1514 1514  |Protocol|Panasonic FP MFWTOCOL|
... ... @@ -1540,25 +1540,25 @@
1540 1540  
1541 1541  **3)Configure the communication protocol**
1542 1542  
1543 -[[image:image-20220831165238-4.png]]
1403 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830171050-1.png?rev=1.1||alt="image-20220830171050-1.png"]]
1544 1544  
1405 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830171126-2.png?rev=1.1||alt="image-20220830171126-2.png"]]
1545 1545  
1546 -
1547 1547  **4)Cable Wiring**
1548 1548  
1549 1549  Figure
1550 1550  
1551 -[[image:image-20220831165031-3.png]][[image:image-20220831165017-2.png]]
1411 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830171328-4.png?rev=1.1||alt="image-20220830171328-4.png"]]
1552 1552  
1553 1553  Pin Definition Diagram
1554 1554  
1555 -[[image:image-20220831165008-1.png]]
1415 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830171146-3.png?rev=1.1||alt="image-20220830171146-3.png"]]
1556 1556  
1557 -= Create communication with LS** PLC** =
1417 += Create communication with LS** PLC**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=41]] =
1558 1558  
1559 -== **XBC serial protocol** ==
1419 +== **XBC serial protocol**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=42]] ==
1560 1560  
1561 -**1)V-BOX Settings**
1421 +**1)HMI Settings**
1562 1562  
1563 1563  |**Item**|**Settings**|**Note**
1564 1564  |Protocol|LS XBC CNet|
... ... @@ -1596,23 +1596,25 @@
1596 1596  
1597 1597  **3)Configure the communication protocol**
1598 1598  
1599 -[[image:image-20220831170147-1.png]]
1459 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830174853-3.png?rev=1.1||alt="image-20220830174853-3.png"]]
1600 1600  
1461 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830174733-2.png?rev=1.1||alt="image-20220830174733-2.png"]]
1462 +
1601 1601  **4)Cable Wiring**
1602 1602  
1603 1603  Figure
1604 1604  
1605 -[[image:image-20220831170306-4.png]][[image:image-20220831170254-3.png]]
1467 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830174659-1.png?rev=1.1||alt="image-20220830174659-1.png"]]
1606 1606  
1607 1607  Pin Definition Diagram
1608 1608  
1609 -[[image:image-20220831170215-2.png]]
1471 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830173402-8.png?rev=1.1||alt="image-20220830173402-8.png"]]
1610 1610  
1611 -== **XGK FEnet Ethernet protocol** ==
1473 +== **XGK FEnet Ethernet protocol**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=43]] ==
1612 1612  
1613 1613  Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module
1614 1614  
1615 -**1)V-BOX Settings**
1477 +**HMI Settings**
1616 1616  
1617 1617  |**Items**|**Settings**|**Note**
1618 1618  |Protocol|LG XGK FEnet(Ethernet)|
... ... @@ -1619,7 +1619,7 @@
1619 1619  |Connection|Ethernet|
1620 1620  |Port No.|2004|
1621 1621  
1622 -**2)Address List**
1484 +**Address List**
1623 1623  
1624 1624  |**Type**|**Register**|**Range**|**Format**|**Note**
1625 1625  |(% rowspan="14" %)Word|P|0~~2047|P d|
... ... @@ -1643,18 +1643,186 @@
1643 1643  * The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC;
1644 1644  * All bit registers are in the form of bits in word, and the range is the same as the word register;
1645 1645  
1646 -**3)Communication Settings**
1508 +**Communication settings in HMI**
1647 1647  
1648 -[[image:image-20220831171127-1.png]]
1510 +Enable HMI Ethernet in [Project Settings];
1649 1649  
1650 -**4)Cable Wiring**
1512 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_43b671f18153910d.png?width=405&height=107&rev=1.1||alt="12.PLC Protocol_html_43b671f18153910d.png" height="107" width="405"]]
1651 1651  
1514 +Set PLC IP in [Device IP] settings;
1515 +
1516 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_a2a19b5003ad4090.png?width=554&height=189&rev=1.1||alt="12.PLC Protocol_html_a2a19b5003ad4090.png" height="189" width="554"]]
1517 +
1518 +**Cable Wiring**
1519 +
1652 1652  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1653 1653  
1654 -= Create communication with **Modbus ** =
1522 += Create communication with **SHIMADEN PLC**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=44]] =
1655 1655  
1656 -== **MODBUS RTU Slave (All function)** ==
1524 +== **FP23 series protocol**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=45]] ==
1657 1657  
1526 +Supported series: SHIMADEN FP23 series
1527 +
1528 +**HMI Setting**
1529 +
1530 +|**Items**|**Settings**|**Note**
1531 +|Protocol|SHIMADEN FP23 series|
1532 +|Connection|RS485 (9600, 1, 7, EVEN)|
1533 +|Port No.|None|
1534 +|PLC station No.|0|
1535 +
1536 +**Address List**
1537 +
1538 +|**Device address**|**HMI register**|**Address range**|**Type**
1539 +|0040-0043(HEX)|FP040|100064-200067|Read only
1540 +|0100-010B(HEX)|FP100|100256-200267|Read only
1541 +|0110-0142(HEX)|FP110|100272-200322|Read only
1542 +|0182-0252(HEX)|FP182|100386-200594|Write only
1543 +|0280-0281(HEX)|FP280|100640-200641|Read only
1544 +|0300-030B(HEX)|FP300|100768-200779|Read and write
1545 +|0380-039F(HEX)|FP380|100896-200927|Read and write
1546 +|0400-04D7(HEX)|FP400|101024-201239|Read and write
1547 +|0500-05B0(HEX)|FP500|101280-201456|Read and write
1548 +|0600-0670(HEX)|FP600|101536-201814|Read and write
1549 +|0720-0738(HEX)|FP720|101824-201848|Read and write
1550 +|0800-083F(HEX)|FP800|102048-202111|Read and write
1551 +|0900-0952(HEX)|FP900|102304-202386|Read and write
1552 +| |Ctrl|0-2|
1553 +
1554 +**✎Note:**
1555 +
1556 +* The upper 2 bits of the address of the HMI register are taken as the sub address, and the real address is the last four bits (for example, if the address is 100256, then 10 is the sub address as 1, and 0256 is the real address);
1557 +* The address range in the table is only divided by the start and end addresses, and some of the addresses in the range have no corresponding address in FP23;
1558 +* The Ctrl register is used to store the control group number and BCC check mode.
1559 +
1560 +**Ctrl Register Description**
1561 +
1562 +* The Ctrl register is a special register that does not communicate with the temperature controller. User needs to assign value in the screen according to the settings as in the temperature controller.
1563 +* Ctrl0 indicates the setting of the control character, the valid values are 1, 2, 3 respectively, and the corresponding control group is: STX_ETX_CR , STX_ETX_CR LF and @_:_CR .
1564 +* Ctrl1 indicates the BCC block check mode. The valid value range is 1-4. The corresponding check mode is: 1.ADD, 2.ADD_two's cmp, 3.XOR, 4.None;
1565 +* Ctrl3 reserved
1566 +
1567 +**✎Note:**
1568 +
1569 +After reloading the HMI project or restarting the HMI, HMI will reset the value of ctrl0 and ctrl1 as 1, so user need to set these two values to make it the same as it in the temperature controller, then communication will be normal.
1570 +
1571 +**Cable Wiring**
1572 +
1573 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5e9a81a14106da9e.png?width=392&height=223&rev=1.1||alt="12.PLC Protocol_html_5e9a81a14106da9e.png" height="223" width="392"]]
1574 +
1575 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_1897d92be6948d58.png?width=393&height=223&rev=1.1||alt="12.PLC Protocol_html_1897d92be6948d58.png" height="223" width="393"]]
1576 +
1577 +**✎Note:** COM3 only available in PI8000/PI9000 series.
1578 +
1579 +== **SR90 protocol**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=46]] ==
1580 +
1581 +Supported series: SHIMADEN SR90 series
1582 +
1583 +**HMI Setting**
1584 +
1585 +|**Items**|**Settings**|**Note**
1586 +|Protocol|SHIMADEN SR90 protocol|
1587 +|Connection|RS485 (1200, 1, 7, EVEN)|
1588 +|Port No.|None|
1589 +|PLC station No.|0|
1590 +
1591 +**Address List**
1592 +
1593 +|**Device address**|**HMI register**|**Address range**|**Type**
1594 +|0040-0043 (HEX)|SR040|100064-100067|Read only
1595 +|0100-010A(HEX)|SR0100|100256-100266|Read only
1596 +|0182-018C(HEX)|SR0182|100386-100396|Write only
1597 +|0300-04FE(HEX)|SR0300|100768-101278|Write/read
1598 +|0500-050B(HEX)|SR0500|101280-101291|Write/read
1599 +|0590-0611(HEX)|SR0590|101424-101553|Write/read
1600 +|0701-0709(HEX)|SR0701|101793-101801|Write/read
1601 +| |Ctrl|0-2|~-~-
1602 +
1603 +**✎Note:**
1604 +
1605 +* The upper 2 bits of the address of HMIs are taken as the sub address, and the real address is the last four bits (for example, if the address is 100256, then 10 is the sub address as 1, and 0256 is the real address);
1606 +* The address range in the table is only divided by the start and end addresses, and some of the addresses in the range have no corresponding address in SR90;
1607 +* The Ctrl register is used to store the control group number and BCC check mode. See how to use it below;
1608 +
1609 +**Ctrl Register Description**
1610 +
1611 +* The Ctrl register is a special register that does not communicate with the temperature controller. User needs to assign value in the screen according to the settings as in the temperature controller.
1612 +* Ctrl0 indicates the setting of the control character, the valid values are 1, 2, 3 respectively, and the corresponding control group is: STX_ETX_CR , STX_ETX_CR LF and @_:_CR .
1613 +* Ctrl1 indicates the BCC block check mode. The valid value range is 1-4. The corresponding check mode is: 1.ADD, 2.ADD_two's cmp, 3.XOR, 4.None;
1614 +* Ctrl3 reserved
1615 +
1616 +**✎Note:**
1617 +
1618 +After reloading the HMI project or restarting the HMI, HMI will reset the value of ctrl0 and ctrl1 as 1, so user need to set these two values to make it the same as it in the temperature controller, then communication will be normal.
1619 +
1620 +**Cable Wiring**
1621 +
1622 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5e9a81a14106da9e.png?width=392&height=223&rev=1.1||alt="12.PLC Protocol_html_5e9a81a14106da9e.png" height="223" width="392"]]
1623 +
1624 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_1897d92be6948d58.png?width=393&height=223&rev=1.1||alt="12.PLC Protocol_html_1897d92be6948d58.png" height="223" width="393"]]
1625 +
1626 +**✎Note:** COM3 only available in PI8000/PI9000 series.
1627 +
1628 +== **MR13 series(standard protocol)**[[Edit>>url:https://docs.we-con.com.cn/bin/edit/PIStudio/12.PLC%20protocols/WebHome?section=47]] ==
1629 +
1630 +Supported series: SHIMADEN MR13 series
1631 +
1632 +**HMI Setting**
1633 +
1634 +|**Items**|**Settings**|**Note**
1635 +|Protocol|SHIMADEN standard protocol|
1636 +|Connection|RS485 (1200, 1, 7, EVEN)|
1637 +|Port No.|None|
1638 +|PLC station No.|0|
1639 +
1640 +**Address List**
1641 +
1642 +|**Device address**|**HMI register**|**Address range**|**Type**
1643 +|0100-010B(HEX)|MR100|100256-300267|Read only
1644 +|0111-0126(HEX)|MR111|100273-300294|Read only
1645 +|0184-0192(HEX)|MR184|100388-300402|Write only
1646 +|0280-0282(HEX)|MR280|100640-300642|Read only
1647 +|0300-030B(HEX)|MR300|100768-300779|Read/write
1648 +|0314-0317(HEX)|MR314|100788-300791|Read/write
1649 +|031A(HEX)|MR31A|100794-300794|Read/write
1650 +|0320-0321(HEX)|MR320|100800-300801|Read/write
1651 +|0400-0504(HEX)|MR400|101024-301284|Read/write
1652 +|0506(HEX)|MR506|101286-301286|Read/write
1653 +|0510-0514(HEX)|MR510|101296-301300|Read/write
1654 +|0516-0524(HEX)|MR516|101302-301316|Read/write
1655 +|0526(HEX)|MR526|101318-301318|Read/write
1656 +|0580-08C3(HEX)|MR580|101408-302243|Read/write
1657 +|~-~-|Ctrl|0-2|~-~-
1658 +
1659 +**✎Note:**
1660 +
1661 +* The upper 2 bits of the address of the HMI register are taken as the sub address, and the real address is the last four bits (for example, if the address is 100256, then 10 is the sub address as 1, and 0256 is the real address);
1662 +* The address range in the table is only divided by the start and end addresses, and some of the addresses in the range have no corresponding address in MR13;
1663 +* The Ctrl register is used to store the control group number and BCC check mode.
1664 +
1665 +**Ctrl Register Description**
1666 +
1667 +* The Ctrl register is a special register that does not communicate with the temperature controller. User needs to assign value in the screen according to the settings as in the temperature controller.
1668 +* Ctrl0 indicates the setting of the control character, the valid values are 1, 2, 3 respectively, and the corresponding control group is: STX_ETX_CR, STX_ETX_CR LF and @_:_CR .
1669 +* Ctrl1 indicates the BCC block check mode. The valid value range is 1-4. The corresponding check mode is: 1.ADD, 2.ADD_two's cmp, 3.XOR, 4.None;
1670 +* Ctrl3 reserved
1671 +
1672 +**✎Note:**
1673 +
1674 +After reloading project or restarting the HMI, HMI will reset the value of ctrl0 and ctrl1 as 1, so user need to set these two values to make it the same as it in the temperature controller, then communication will be normal.
1675 +
1676 +**Cable Wiring**
1677 +
1678 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5e9a81a14106da9e.png?width=392&height=223&rev=1.1||alt="12.PLC Protocol_html_5e9a81a14106da9e.png" height="223" width="392"]]
1679 +
1680 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_1897d92be6948d58.png?width=393&height=223&rev=1.1||alt="12.PLC Protocol_html_1897d92be6948d58.png" height="223" width="393"]]
1681 +
1682 +**✎Note:** COM3 only available in PI8000/PI9000 series.
1683 +
1684 += Create communication with **Modbus RTU** =
1685 +
1686 +== **V-BOX as Slave** ==
1687 +
1658 1658  Select the protocol "Modbus RTU Slave (All Fuction)",
1659 1659  
1660 1660  Then set baud rate, port, stop bits, data bits, parity.
... ... @@ -1662,7 +1662,7 @@
1662 1662  (% style="text-align:center" %)
1663 1663  [[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]]
1664 1664  
1665 -== **MODBUS RTU Master** ==
1695 +== **V-BOX as Master** ==
1666 1666  
1667 1667  Select the protocol "Modbus RTU Master",
1668 1668  
... ... @@ -1698,61 +1698,6 @@
1698 1698  |(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils)
1699 1699  |0F (Write multiple bits)
1700 1700  
1701 -== **MODBUS TCP Slave (All function)** ==
1702 -
1703 -Supported series: MODBUS TCP controller
1704 -
1705 -V-B0X works as MODBUS TCP MASTER connecting with TCP SLAVE
1706 -
1707 -**1)V-BOX Setting**
1708 -
1709 -|**Items**|**Settings**|**Note**
1710 -|Protocol|MODBUS TCP Slave (All function)|
1711 -|Connection|Ethernet|
1712 -|Port No.|502|
1713 -|PLC station No.|1
1714 -
1715 -**2)Address List**
1716 -
1717 -|**Type**|**Register**|**Function code & Description**
1718 -|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers)
1719 -|06 (write single register: write a binary value to a holding register)
1720 -|10 (write values to multiple addresses )
1721 -|(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers)
1722 -|06 (write single register: write a binary value to a holding register)
1723 -|10 (write values to multiple addresses )
1724 -|(% rowspan="3" %)W6|03 (read holding register: read current binary value in one or more holding registers)
1725 -|06 (write single register: write a binary value to a holding register)
1726 -|10 (write values to multiple addresses )
1727 -|(% rowspan="2" %)W16|03 (read holding register: read current binary value in one or more holding registers)
1728 -|10 (write values to multiple addresses )
1729 -|(% rowspan="11" %)Bit|(% rowspan="3" %)0|01 (Read coil state)
1730 -|05 (Force a single coil to force the on/off state of a logic coil)
1731 -|0F (Write multiple bits, ie write continuously)
1732 -|(% rowspan="3" %)1|02 (Read the input state)
1733 -|05 (Force a single coil to force the on/off state of a logic coil)
1734 -|0F (Write multiple bits)
1735 -|(% rowspan="3" %)W5|01 (Read coil state to obtain the current state of a set of logic coils)
1736 -|05 (Force a single coil to force the on/off state of a logic coil)
1737 -|0F (Write multiple bits)
1738 -|(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils)
1739 -|0F (Write multiple bits)
1740 -
1741 -**3)Communication Settings**
1742 -
1743 -Configure V-BOX Ethernet IP in Networking Settings
1744 -
1745 -[[image:image-20220902111833-3.png]]
1746 -
1747 -
1748 -Configure PLC Ethernet IP in Communication;
1749 -
1750 -[[image:image-20220902111121-1.png]]
1751 -
1752 -**4)Cable Wiring**
1753 -
1754 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1755 -
1756 1756  == **communicate with VB inverter** ==
1757 1757  
1758 1758  [[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20VB%20inverter.zip]]
image-20220831165008-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -13.3 KB
Content
image-20220831165017-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -36.2 KB
Content
image-20220831165031-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -28.3 KB
Content
image-20220831165238-4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -57.4 KB
Content
image-20220831170147-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -57.1 KB
Content
image-20220831170215-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -14.3 KB
Content
image-20220831170254-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -43.5 KB
Content
image-20220831170306-4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -28.5 KB
Content
image-20220831171127-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -60.1 KB
Content
image-20220902104329-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -58.7 KB
Content
image-20220902111121-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -60.9 KB
Content
image-20220902111754-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -57.6 KB
Content
image-20220902111833-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -56.1 KB
Content