Changes for page 1 Communication

Last modified by Hunter on 2024/07/01 10:54

From version 171.1
edited by Bob
on 2022/11/16 10:56
Change comment: There is no comment for this version
To version 220.3
edited by Hunter
on 2023/03/23 11:24
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Bob
1 +XWiki.Hunter
Content
... ... @@ -176,16 +176,116 @@
176 176  
177 177  The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC.
178 178  
179 -= Create communication with **Rockwell PLC** =
179 += Create communication with Allen-Bradley(**Rockwell**)** PLC** =
180 180  
181 -== (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** ==
181 +== **DF1 Advanced Protocol** ==
182 182  
183 +MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05; PLC-5
184 +
185 +**1) V-Box Settings**
186 +
187 +|=Item|=Recommended |=Note
188 +|=Protocol|Allen Bradley DF1 Advanced|
189 +|=Connection|RS232|
190 +|=Baud rate|19200|
191 +|=Stop bits|1|
192 +|=Data bits|8|
193 +|=Parity|None|
194 +|=PLC Station No.|1|
195 +|=HMI Station No.|0|
196 +
197 +**2) Address List**
198 +
199 +|=**Type**|=**Device registers**|=**Format**|=**Range**|=Note
200 +|(% colspan="1" rowspan="7" %)Bit|I1|I1ddd.dd|0.0~~255.15|Only able to communicate with file number I1
201 +|O0|O0ddd.dd|0.0~~255.15|Only able to communicate with file number O0
202 +|S2|S2ddd.dd|0.0~~255.15|Only able to communicate with file number S2
203 +|B3|B3ddd.dd|0.0~~255.15|Only able to communicate with file number B3
204 +|BN|BNddddd.dd|0.0~~99255.15|(((
205 +Bit data file B0~~B99
206 +
207 +First two digits is for file number
208 +
209 +For example, BN13001.00 represents file number B13, address 001, the 0th bit.
210 +)))
211 +|N7|N7ddd.dd|0.0~~255.15|Only able to communicate with file number N7
212 +|NN|NNddddd.dd|0.0~~99255.15|(((
213 +Integer data file bit format N0~~N99
214 +
215 +First two digits is for file number
216 +
217 +For example, NN13001.00 represents file number N13, address 001, the 0th bit.
218 +)))
219 +|(% rowspan="11" %)Word|S2|S2ddd|0~~255|Only able to communicate with file number S2
220 +|T4S|T4Sddd|0~~255|Only able to communicate with file number T4 (Timer Preset Value)
221 +|T4P|T4Pddd|0~~255|Only able to communicate with file number T4 (Timer Accumulator Value)
222 +|TNS|TNSddddd|0~~99255|(((
223 +Timer Preset Value
224 +
225 +First two digits is for file number
226 +
227 +For example, TNS99255 represents file number T99, address 255.
228 +)))
229 +|TNP|TNPddddd|0~~99255|(((
230 +Timer Accumulator Value
231 +
232 +First two digits is for file number
233 +
234 +For example, TNP99255 represents file number T99, address 255.
235 +)))
236 +|C5S|C5Sddd|0~~255|Only able to communicate with file number C5 (Counter Preset Value)
237 +|C5P|C5Pddd|0~~255|Only able to communicate with file number C5 (Counter Accumulator Value)
238 +|CNS|CNSddddd|0~~99255|(((
239 +Counter Preset Value
240 +
241 +First two digits is for file number
242 +
243 +For example, CNS99255 represents file number C99, address 255.
244 +)))
245 +|CNP|CNPddddd|0~~99255|(((
246 +Counter Accumulator Value
247 +
248 +First two digits is for file number
249 +
250 +For example, CNP99255 represents file number C99, address 255.
251 +)))
252 +|N7|N7ddd|0~~255|Only able to communicate with file number N7
253 +|NN|NNddd|0~~99255|(((
254 +Integer data file
255 +
256 +First two digits is for file number
257 +
258 +For example, NN99255 represents file number N99, address 255.
259 +)))
260 +|(% colspan="1" rowspan="3" %)Double Word|F8|F8ddd|0~~255|(((
261 +Only able to communicate with file number N7
262 +)))
263 +|FN|FNddddd|0~~99255|(((
264 +Floating point data file
265 +
266 +First two digits is for file number
267 +
268 +For example, FN99255 represents file number F99, address 255.
269 +)))
270 +|LN|LNddddd|0~~99255|Long
271 +
272 +**3) Cable Wiring**
273 +
274 +(% style="text-align:center" %)
275 +[[image:ABRS232.gif]]
276 +
277 +(% class="wikigeneratedid" id="HMicroLogixA0Protocol" %)
278 +(% id="cke_bm_5621S" style="display:none" %)** **
279 +
280 +== **MicroLogix Protocol** ==
281 +
282 +(% class="wikigeneratedid" %)
183 183  MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
184 184  
185 185  **1)V-BOX setting**
186 186  
187 187  |**Item**|**Settings**|**Note**
188 -|Protocol|Allen-Bradlley DF1 Advanced|
288 +|Protocol|Allen-Bradley DF1 Advanced|
189 189  |Connection|RS232|
190 190  |Baud rate|19200|
191 191  |Data bit|8|
... ... @@ -419,12 +419,64 @@
419 419  (((
420 420  The above are all the steps for establishing Ethernet communication between Wecon V-box with CompactLogix L1769 PLC.
421 421  
522 +== **Ethernet DF1 Protocol** ==
422 422  
423 -== **Allen-Bradley Ethernet DF1** ==
424 -
425 425  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]]
426 426  
526 += Create communication with **Crouzet PLC** =
427 427  
528 +== **CROUZET M3 (FBD)** ==
529 +
530 +Support Series: Crouzet Millenium 3 CD12/CB12
531 +
532 +**1)V-BOX setting**
533 +
534 +|=Item|=Recommended |=Note
535 +|=Protocol|CROUZET M3 (FBD)|
536 +|=Connection|RS232|
537 +|=Baud rate|115200|
538 +|=Stop bits|1|
539 +|=Data bits|7|
540 +|=Parity|EVEN|
541 +
542 +**2)Address List**
543 +
544 +|=**Type**|=**Device registers**|=**Format**|=**Range**|=Note
545 +|(% rowspan="4" %)Bit|I|I DD|1~~99|Input
546 +|SLIBit|SLIBit DD.dd|1.0~~24.15|Serial Link Input
547 +|SLOBit|SLOBit DD.dd|25.0~~48.15|Serial Link Output(Read only)
548 +|State|State D|1~~1|PLC state(Read only)
549 +|(% rowspan="5" %)Word|AI|AI DD|1~~99|Analog Input
550 +|SLIn|SLIn DD|1~~24|Serial Link Input
551 +|SLOut|SLOut DD|25~~48|Serial Link Output(Read only)
552 +|Time|Time D|1~~6|(((
553 +Time1: Second
554 +
555 +Time2: Minute
556 +
557 +Time3: Hour
558 +
559 +Time4: Day
560 +
561 +Time5: Month
562 +
563 +Time6: Year
564 +)))
565 +|Order|Order D|1~~1|(((
566 +Running command(Write only)
567 +
568 +~=2: Run mode; =1: Stop mode;
569 +)))
570 +
571 +**3)Cable Wiring**
572 +
573 +(% style="text-align:center" %)
574 +[[image:CrouzetRS232 VBox.png]]
575 +
576 +{{info}}
577 +**✎Note: **As the wiring diagram indicated, this protocol requires the DB9 serial port pin 4. But pin 4 is undefined for all V-Box, so it need the user to solder a Pull-up resistor to make the pin 4 working. As for how to solder the resistor on the motherboard, please contact with Wecon technical support for the details.
578 +{{/info}}
579 +
428 428  = Create communication with **Siemens PLC** =
429 429  
430 430  == **S7-200 Smart Ethernet Protocol** ==
... ... @@ -608,6 +608,97 @@
608 608  
609 609  [[image:image-20220824162342-2.png]]
610 610  
763 +== **LOGO Ethernet Protocol** ==
764 +
765 +Supported Series: Siemens Logo 0BA0, 0BA1 series
766 +
767 +**V-BOX Settings**
768 +
769 +
770 +|**Items**|**Settings**|**Note**
771 +|Protocol|Siemens LOGO|
772 +|Connection|Ethernet|
773 +|Port No.|102|
774 +|PLC station No.|2|
775 +
776 +**Address List**
777 +
778 +
779 +|**Number**|**Address Type**|**Data Type**|**Range**|**DB Address**|**PLC Address**
780 +|1|RTC|Word|1-7|DB1.DBX984.0|0x001ec0
781 +|2|VB|Byte|0-1469|DB1.DBX0.0|0x000000
782 +|3|VD|Double Word|0-1466|DB1.DBX0.0|0x000000
783 +|4|VW|Word|0-1468|DB1.DBX0.0|0x000000
784 +|5|NAQ|Word|1-32|DB1.DBX1406.0|0x002bf0
785 +|6|NAI|Word|1-64|DB1.DBX1262.0|0x002770
786 +|7|AM|Word|1-64|DB1.DBX1118.0|0x0022f0
787 +|8|AQ|Word|1-16|DB1.DBX1072.0|0x002180
788 +|9|AI|Word|1-16|DB1.DBX1032.0|0x002040
789 +|10|I|Bit|1-64|DB1.DBX1024.0|0x002000
790 +|11|Q|Bit|1-64|DB1.DBX1064.0|0x002140
791 +|12|M|Bit|1-112|DB1.DBX1104.0|0x002280
792 +|13|NI|Bit|1-128|DB1.DBX1246.0|0x0026f0
793 +|14|NQ|Bit|1-128|DB1.DBX1390.0|0x002b70
794 +|15|V|Bit|0-14697|DB1.DBX0.0|0x000000
795 +
796 +**PLC Settings in LOGO Software:**
797 +
798 +Click [Tools]~-~-[Ethernet Connections],shown as below.
799 +
800 +(% style="text-align:center" %)
801 +[[image:PIStudio.12\.PLC protocols.WebHome@12.PLC Protocol_html_8b9d2322edf89519.png]]
802 +
803 +Set Ethernet connection parameter. IP, Subnet Mask, shown as below.
804 +
805 +(% style="text-align:center" %)
806 +[[image:PIStudio.12\.PLC protocols.WebHome@image-20221228142937-4.png]]
807 +
808 +**TSAP set**:The value set by local TSAP is the remote TSAP set in HMI. PLC's remote TSAP is the opposite,shown as below.
809 +
810 +(% style="text-align:center" %)
811 +[[image:PIStudio.12\.PLC protocols.WebHome@image-20221228143047-5.png]]
812 +
813 + **Download Project**: Click "Address book" to add the IP address to be downloaded (fi."Detect" to check whether the IP address can be detected. Then click “ok”, and the system will prompt that PLC will be "STOP" mode. Click “YES” to start download.
814 +
815 +(% style="text-align:center" %)
816 +[[image:PIStudio.12\.PLC protocols.WebHome@image-20221228143246-6.png]]
817 +
818 +**V-BOX Communication Settings**
819 +
820 +Set PLC IP in [IP Address] settings;
821 +
822 +(% style="text-align:center" %)
823 +[[image:LldwDGntf4.png]]
824 +
825 +Enable V-BOX Ethernet in [Network];
826 +
827 +(% style="text-align:center" %)
828 +[[image:WgvjfWbQif.png]]
829 +
830 +TSAP setting
831 +
832 +* The initialization script needs to set the source TSAP address and the target TSAP address, otherwise the communication will not be successful.
833 +
834 +{{code language="LUA"}}
835 +function init.main()
836 +addr_setword("@W_0#HSW1200",8192) -- Set the source TSAP address
837 +addr_setword("@W_0#HSW1201",4096) -- Set the destination TSAP address
838 +end
839 +{{/code}}
840 +
841 +Note: The name of the test script is init, 8192 and 4096 are the data used for the test, there is no HSW address in the register option, but you can directly set the value of the corresponding address through the code.
842 +
843 +**✎Note:**
844 +
845 +* **Communication port configuration: **
846 +** Continuous length needs to be set to 0.
847 +** Integration interval needs to be set to 1. (no change may result in data errors)
848 +** Set Port and Device Station NO.
849 +** Other set as defaulted.
850 +* **Notes on the use of registers:**
851 +** Register VD: Use only registers that are multiples of 4, such as 0, 4, 8, etc.
852 +** Register VW: Use only registers thay are multiples of 2, such as 0, 2, 4 etc. (Using an odd-length register may result in data errors, such as 2 3 4 )
853 +
611 611  = Create communication with **Mitsubishi PLC** =
612 612  
613 613  == **FX1S,1N,2N Serial Protocol** ==
... ... @@ -706,9 +706,9 @@
706 706  
707 707  == **FX3U Ethernet Protocol** ==
708 708  
709 - Mitsubishi FX3U series PLC
952 +Supported ModulesFX3U-ENET-ADP, FX3U-ENET-L
710 710  
711 -**HMI Settings**
954 +**1)V-BOX Settings**
712 712  
713 713  |Items|Settings|Note
714 714  |Protocol|Mitsubishi FX3U|
... ... @@ -716,7 +716,7 @@
716 716  |Port No.|5009|Must be the same as the PLC setting
717 717  |PLC station No.|0|
718 718  
719 -**Address List**
962 +**2)Address List**
720 720  
721 721  |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
722 722  |(% colspan="1" rowspan="7" %)Bit|X|X|X OOO|0~~377|
... ... @@ -732,22 +732,20 @@
732 732  |SD|SD|SD DDDD|8000~~8511|
733 733  |R|R|R DDDDD|0~~32767|
734 734  
735 -**Ethernet Module Settings**
978 +**3)Ethernet Module Settings**
736 736  
737 737  FX3U-ENET-L module configuration
738 738  Set up the FX3U-ENET-L Ethernet module settings as follows.
739 739  Select the module location, which in this document is Module 0.
740 740  
741 -[[image:image-20221116094003-1.png]]
984 +[[image:image-20221116105850-1.png]]
742 742  
743 -
744 744  Select "Operational setting" to enter the following screen.
745 745  
746 746  The Ethernet module IP is set to 192.168.39.254 in this document, and other options are default.
747 747  
748 -[[image:image-20221116094019-2.png]]
990 +[[image:image-20221116105947-1.png]]
749 749  
750 -
751 751  Select "Open setting" to enter the setting interface, the settings are as follows.
752 752  
753 753  The third item "Protocol" selects TCP, and "Open system" selects MELSOFT connection, which allows the
... ... @@ -754,9 +754,8 @@
754 754  
755 755  Mitsubishi programming software GX works2 to communicate with the FX3U via the Ethernet module.
756 756  
757 -[[image:image-20221116094038-3.png]]
998 +[[image:image-20221116110802-1.png]]
758 758  
759 -
760 760  Click on "transter setup" - "PC side I/F setting", see the following figure.
761 761  
762 762  After setting, the first download must use the programming cable, as shown in the figure; after that, can
... ... @@ -763,53 +763,45 @@
763 763  
764 764  use the IP set in the "Ethernet board" to communicate directly with the network cable.
765 765  
766 -[[image:image-20221116094122-4.png||height="422" width="707"]]
1006 +[[image:image-20221116110832-2.png||height="423" width="708"]]
767 767  
768 -
769 769  Read and write data from the Ethernet module
770 770  
771 -[[image:image-20221116094131-5.png||height="551" width="708"]]
1010 +[[image:image-20221116110907-3.png]]
772 772  
773 -
774 774  Set "Transter setup" to COM communication, and read or write operation as shown below
775 775  
776 -[[image:image-20221116094150-6.png]]
1014 +[[image:image-20221116110917-4.png]]
777 777  
1016 +**4)PLC Settings (GX Works 2)**
778 778  
779 -**PLC Settings (GX Works 2)**
780 -
781 781  Create a blank FX5U project
782 782  
783 783  Find Current Connection in the navigation
784 784  
785 -[[image:image-20221116094206-7.png||height="425" width="711"]]
1022 +[[image:image-20221116111427-1.png||height="421" width="705"]]
786 786  
787 -
788 788  Select Connection Channel List
789 789  
790 790  Select Ethernet board communication
791 791  
792 -[[image:image-20221116094709-9.png||height="427" width="715"]]
1028 +[[image:image-20221116111451-2.png||height="421" width="705"]]
793 793  
794 -
795 795  Select Ethernet Module
796 796  Set the IP address of the PLC
797 797  
798 -[[image:image-20221116094736-11.png||height="682" width="716"]]
1033 +[[image:image-20221116111509-3.png||height="666" width="699"]]
799 799  
800 -
801 801  Read or write PLC data, in this document is read
802 802  
803 -[[image:image-20221116094755-12.png||height="426" width="715"]]
1037 +[[image:image-20221116111651-4.png||height="416" width="697"]]
804 804  
805 -[[image:image-20221116094803-13.png||height="427" width="715"]]
1039 +[[image:image-20221116111727-5.png||height="416" width="697"]]
806 806  
807 -**V-BOX Communication Setting**
1041 +**4)Configure the communication protocol**
808 808  
1043 +[[image:image-20221119101946-2.png||height="395" width="695"]]
809 809  
810 -
811 -
812 -
813 813  == **FX5U Serial Protocol** ==
814 814  
815 815  Mitsubishi FX5U series PLC
... ... @@ -1101,6 +1101,12 @@
1101 1101  
1102 1102  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1103 1103  
1336 +== **Q12H Serial Protocol** ==
1337 +
1338 +This Demo shows V-BOX communicate with Q12H PLC by Q02H serial Protocol
1339 +
1340 +[[**Download link**>>https://ftp.we-con.com.cn/Download/WIKI/PI%20HMI/Demo/Communication/V-Box%20connect%20PLC%20Q12H.rar]]
1341 +
1104 1104  == **QJ71E71 Ethernet Protocol** ==
1105 1105  
1106 1106  Mitsubishi QJ71E71 Ethernet communication module;
... ... @@ -1149,10 +1149,13 @@
1149 1149  
1150 1150  * Click [Ethernet/CC IE/MELSECNET];
1151 1151  * Please select [Ethernet] as network type;
1152 -* Set station I/O number according to situation (For example, 0000 means that the module is connected to PLC CPU in first order);
1390 +* Set station I/O number according to situation (For example, 0020 means that the module is connected to PLC CPU in first order);
1153 1153  * Select [Online] as Mode;
1392 +* [[image:image-20221119171343-2.png||height="341" width="587"]]
1154 1154  * Click [Operation setting] to set IP;
1155 1155  * Select [Binary Code] as [Communication Data Code];
1395 +* [[image:image-20221119171436-3.png||height="354" width="588"]]
1396 +* Click [Open setting]
1156 1156  * Set protocol: TCP;
1157 1157  * Set [unpassive] in [Open system];
1158 1158  * Set [receive] in [Fixed buffer];
... ... @@ -1159,14 +1159,16 @@
1159 1159  * Set [procedure Exist] in [Fixed buffer communication];
1160 1160  * Disable [Pairing open];
1161 1161  * Set [No confirm] in [Existence confirmation];
1162 -* Host station port number: 1025;
1403 +* Host station port number: 5009;
1163 1163  * Save settings;
1405 +* [[image:image-20221119171611-4.png||height="354" width="588"]]
1164 1164  * Download project into PLC and restart it
1165 1165  
1166 1166  **4)Configure the communication protocol**
1167 1167  
1168 -[[image:image-20220825143728-1.png]]
1410 +[[image:image-20221119171832-5.png||height="354" width="625"]]
1169 1169  
1412 +
1170 1170  **5)Cable Wiring**
1171 1171  
1172 1172  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png"]]
... ... @@ -1175,12 +1175,105 @@
1175 1175  
1176 1176  == **DVP Ethernet Protocol** ==
1177 1177  
1178 -[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
1421 +Supoort Series: DELTA DVP20/32/40/60ES200RE/200TE or any DVP models with built-in Ethernet port, DELTA DVPEN01-SL module
1179 1179  
1423 +**1)V-BOX Settings**
1424 +
1425 +|=**Items**|=**Settings**|=**Note**
1426 +|Protocol|DELTA DVP MODBUS TCP|
1427 +|Connection|Ethernet|
1428 +|Port No.|502|
1429 +|Device No.|1|
1430 +|VBox Device No.|0|
1431 +
1432 +**2)Address List **
1433 +
1434 +|=**Type**|=(% style="width: 191px;" %)**Device registers**|=(% style="width: 217px;" %)**VBox registers**|=(% style="width: 168px;" %)**Format**|=(% style="width: 225px;" %)**Range**|=**Note**
1435 +|Bit|(% style="width:191px" %)X|(% style="width:217px" %)X|(% style="width:168px" %)X OOO|(% style="width:225px" %)0~~377|
1436 +|Bit|(% style="width:191px" %)Y|(% style="width:217px" %)Y|(% style="width:168px" %)Y OOO|(% style="width:225px" %)0~~377|
1437 +|Bit|(% style="width:191px" %)M0|(% style="width:217px" %)M0|(% style="width:168px" %)M0DDDD|(% style="width:225px" %)0~~1535|
1438 +|Bit|(% style="width:191px" %)M1|(% style="width:217px" %)M1|(% style="width:168px" %)M1DDDD|(% style="width:225px" %)1536~~4096|
1439 +|Bit|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDD|(% style="width:225px" %)0~~255|
1440 +|Bit|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDD|(% style="width:225px" %)0~~255|
1441 +|Bit|(% style="width:191px" %)S|(% style="width:217px" %)S|(% style="width:168px" %)SDDDD|(% style="width:225px" %)0~~1023|
1442 +|Word|(% style="width:191px" %)D0|(% style="width:217px" %)D0|(% style="width:168px" %)D0DDDD|(% style="width:225px" %)0~~4095|
1443 +|Word|(% style="width:191px" %)D1|(% style="width:217px" %)D1|(% style="width:168px" %)D1DDDD|(% style="width:225px" %)4096~~11999|
1444 +|Word|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDD|(% style="width:225px" %)0~~255|
1445 +|Word|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDD|(% style="width:225px" %)0~~199|
1446 +|Double Word|(% style="width:191px" %)HC|(% style="width:217px" %)HC|(% style="width:168px" %)HCDDD|(% style="width:225px" %)200~~255|
1447 +
1448 +**3) PLC Setting:**
1449 +
1450 +~1. Create new project in Delta WPL Soft, and click Setting to open the communication settings:
1451 +
1452 +(% style="text-align:center" %)
1453 +[[image:DVPEthernetWPLSoft2.png]]
1454 +
1455 +2. Set up the communication type and PLC IP:
1456 +
1457 +(% style="text-align:center" %)
1458 +[[image:DVPEthernetSetup.png]]
1459 +
1460 +(% class="wikigeneratedid" %)
1461 +3. Click OK and save the settings. Then click Communication on toolbar, then click Transfer Setup to open new window:
1462 +
1463 +(% style="text-align:center" %)
1464 +[[image:DVPEthernetTransfer.png]]
1465 +
1466 +(% class="wikigeneratedid" %)
1467 +4. Select Communication Mode as PC => PLC to download or select PC <=PLC to upload:
1468 +
1469 +(% style="text-align:center" %)
1470 +[[image:DVPEthernetPLCtoPC.png]]
1471 +
1472 +5. Click Auto-Search Ethernet Module to find the PLC on the same LAN network:
1473 +
1474 +(% style="text-align:center" %)
1475 +[[image:DVPEthernetAutoSearch.png]]
1476 +
1477 +**4) V-BOX Setting:**
1478 +
1479 +Set the same IP address according to the setting from WPL Soft:
1480 +
1481 +(% style="text-align:center" %)
1482 +[[image:DVPEthernetVNETPortocol.png]]
1483 +
1180 1180  == **DVP serial protocol** ==
1181 1181  
1182 -[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
1486 +Supoort Series: DELTA DVP EH/ES/SS/EX/EH2/SV/SA/SC/SX
1183 1183  
1488 +**1)V-BOX Settings**
1489 +
1490 +|=**Items**|=**Settings**|=**Note**
1491 +|Protocol|DELTA DVP PROTOCOL|
1492 +|Connection|RS232|
1493 +|Baud Rate|9600|
1494 +|Stop Bit|1|
1495 +|Data Bit|7|
1496 +|Parity|EVEN|
1497 +|Device No.|1|
1498 +
1499 +(% class="wikigeneratedid" %)
1500 +**2)Address List**
1501 +
1502 +|=**Type**|=(% style="width: 191px;" %)**Device registers**|=(% style="width: 217px;" %)**VBox registers**|=(% style="width: 168px;" %)**Format**|=(% style="width: 225px;" %)**Range**|=**Note**
1503 +|Bit|(% style="width:191px" %)X|(% style="width:217px" %)X|(% style="width:168px" %)X OOOOOO|(% style="width:225px" %)0~~303237|
1504 +|Bit|(% style="width:191px" %)Y|(% style="width:217px" %)Y|(% style="width:168px" %)Y OOOOOO|(% style="width:225px" %)0~~303237|
1505 +|Bit|(% style="width:191px" %)M|(% style="width:217px" %)M|(% style="width:168px" %)MDDDDD|(% style="width:225px" %)0~~99999|
1506 +|Bit|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDDDD|(% style="width:225px" %)0~~99999|
1507 +|Bit|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDDDD|(% style="width:225px" %)0~~99999|
1508 +|Bit|(% style="width:191px" %)S|(% style="width:217px" %)S|(% style="width:168px" %)SDDDDD|(% style="width:225px" %)0~~99999|
1509 +|Word|(% style="width:191px" %)D|(% style="width:217px" %)D|(% style="width:168px" %)D DDDDD|(% style="width:225px" %)0~~99999|
1510 +|Word|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDDDD|(% style="width:225px" %)0~~99999|
1511 +|Word|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDD|(% style="width:225px" %)0~~199|
1512 +|Double Word|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDDDD|(% style="width:225px" %)200~~99999|
1513 +
1514 +(% class="wikigeneratedid" %)
1515 +**3)Wiring Diagram**
1516 +
1517 +(% style="text-align:center" %)
1518 +[[image:Delta DVP PROTOCOLSerial232.png]]
1519 +
1184 1184  == **AS Ethernet Protocol** ==
1185 1185  
1186 1186  **1)V-BOX Settings**
... ... @@ -1214,7 +1214,6 @@
1214 1214  
1215 1215  **3)Configure the communication protocol**
1216 1216  
1217 -
1218 1218  [[image:image-20220831160010-4.png]]
1219 1219  
1220 1220  **4)Cable Wiring**
... ... @@ -1347,7 +1347,7 @@
1347 1347  
1348 1348  **1)V-BOX Settings**
1349 1349  
1350 -Supported Series: Delta Xinjie XD/XE Series PLC
1685 +Supported Series: Xinjie XD/XE Series PLC
1351 1351  
1352 1352  |**Item**|**Settings**|**Note**
1353 1353  |Protocol|XINJE XD/XC MODBUS|
... ... @@ -1417,7 +1417,6 @@
1417 1417  
1418 1418  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830160232-3.png?rev=1.1||alt="image-20220830160232-3.png"]]
1419 1419  
1420 -
1421 1421  = Create communication with **Schneider PLC** =
1422 1422  
1423 1423  == **Schneider MODBUS RTU** ==
... ... @@ -1662,6 +1662,17 @@
1662 1662  (% style="text-align:center" %)
1663 1663  [[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]]
1664 1664  
1999 +== **Communicate with Modbus Meter** ==
2000 +
2001 +The following example is using the Linfee meter LNF96EY to demonstrate how to set up the Modbus communication.
2002 +
2003 +~1. Check the specific Modbus parameter in the communication menu from LED display.
2004 +
2005 +So from the following pictures, we can know the Meter Address is 85, Baud rate is 9600, CRC None.
2006 +
2007 +(% style="text-align:center" %)
2008 +[[image:MeterModbusAllView.png]]
2009 +
1665 1665  == **MODBUS RTU Master** ==
1666 1666  
1667 1667  Select the protocol "Modbus RTU Master",
... ... @@ -1674,8 +1674,8 @@
1674 1674  **address list**
1675 1675  
1676 1676  (% class="table-bordered" %)
1677 -|**type**|**register**|**Function code and description**
1678 -|(% rowspan="11" %)|(% rowspan="3" %)3|04 (Read Input Registers: Read the current binary value in one or more input registers)
2022 +|=(% scope="row" %)**Type**|=**Data Type**|=**Function code and description**
2023 +|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (Read Input Registers: Read the current binary value in one or more input registers)
1679 1679  |06 (write single register: write a binary value to a holding register)
1680 1680  |10 (write values to multiple addresses )
1681 1681  |(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers)
... ... @@ -1714,7 +1714,7 @@
1714 1714  
1715 1715  **2)Address List**
1716 1716  
1717 -|**Type**|**Register**|**Function code & Description**
2062 +|=**Type**|=**Data Type**|=**Function code & Description**
1718 1718  |(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers)
1719 1719  |06 (write single register: write a binary value to a holding register)
1720 1720  |10 (write values to multiple addresses )
0Il1q9GZgk.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +24.6 KB
Content
AB.gif
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +7.3 KB
Content
ABRS232.gif
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +7.3 KB
Content
CrouzetRS232 VBox.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +14.9 KB
Content
DVPEthernetAutoSearch.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +43.6 KB
Content
DVPEthernetPLCtoPC.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +8.9 KB
Content
DVPEthernetSetup.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +19.9 KB
Content
DVPEthernetTransfer.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +59.9 KB
Content
DVPEthernetVNETPortocol.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +21.4 KB
Content
DVPEthernetWPLSoft.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +97.5 KB
Content
DVPEthernetWPLSoft2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +45.2 KB
Content
Delta DVP PROTOCOLSerial232.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +10.7 KB
Content
LldwDGntf4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +24.3 KB
Content
MeterModbusAddr.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +562.5 KB
Content
MeterModbusAllView.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +1.6 MB
Content
MeterModbusBaud.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +444.0 KB
Content
MeterModbusPara.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +532.0 KB
Content
WgvjfWbQif.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +36.3 KB
Content
image-20221116105850-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +18.9 KB
Content
image-20221116105947-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +18.7 KB
Content
image-20221116110802-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +16.4 KB
Content
image-20221116110832-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +42.2 KB
Content
image-20221116110907-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +17.8 KB
Content
image-20221116110917-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +23.2 KB
Content
image-20221116111427-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +63.4 KB
Content
image-20221116111451-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +225.5 KB
Content
image-20221116111509-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +34.1 KB
Content
image-20221116111651-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +74.3 KB
Content
image-20221116111727-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +106.2 KB
Content
image-20221116114106-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +99.5 KB
Content
image-20221119101759-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +62.1 KB
Content
image-20221119101946-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +68.7 KB
Content
image-20221119171318-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +90.3 KB
Content
image-20221119171343-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +90.3 KB
Content
image-20221119171436-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +43.4 KB
Content
image-20221119171611-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +23.1 KB
Content
image-20221119171832-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +69.6 KB
Content