Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -704,9 +704,9 @@ 704 704 [[image:image-20220825100845-4.png]] 705 705 706 706 707 -== **FX3U Ethernet Protocol** == 707 +== ** FX3U Ethernet Protocol** == 708 708 709 - 709 +Mitsubishi FX3U series PLC 710 710 711 711 **HMI Settings** 712 712 ... ... @@ -738,15 +738,14 @@ 738 738 Set up the FX3U-ENET-L Ethernet module settings as follows. 739 739 Select the module location, which in this document is Module 0. 740 740 741 +[[image:image-20221115140802-1.png]] 741 741 742 -[[image:image-20221116105850-1.png]] 743 - 744 744 Select "Operational setting" to enter the following screen. 745 745 746 746 The Ethernet module IP is set to 192.168.39.254 in this document, and other options are default. 747 747 747 +[[image:image-20221115142728-4.png]] 748 748 749 - 750 750 Select "Open setting" to enter the setting interface, the settings are as follows. 751 751 752 752 The third item "Protocol" selects TCP, and "Open system" selects MELSOFT connection, which allows the ... ... @@ -753,8 +753,8 @@ 753 753 754 754 Mitsubishi programming software GX works2 to communicate with the FX3U via the Ethernet module. 755 755 755 +[[image:image-20221115142945-5.png]] 756 756 757 - 758 758 Click on "transter setup" - "PC side I/F setting", see the following figure. 759 759 760 760 After setting, the first download must use the programming cable, as shown in the figure; after that, can ... ... @@ -761,16 +761,16 @@ 761 761 762 762 use the IP set in the "Ethernet board" to communicate directly with the network cable. 763 763 763 +[[image:image-20221115143341-6.png||height="426" width="712"]] 764 764 765 - 766 766 Read and write data from the Ethernet module 767 767 767 +[[image:image-20221115143703-7.png]] 768 768 769 - 770 770 Set "Transter setup" to COM communication, and read or write operation as shown below 771 771 771 +[[image:image-20221115143809-8.png]] 772 772 773 - 774 774 **PLC Settings (GX Works 2)** 775 775 776 776 Create a blank FX5U project ... ... @@ -777,28 +777,25 @@ 777 777 778 778 Find Current Connection in the navigation 779 779 779 +[[image:image-20221115144335-9.png||height="422" width="706"]] 780 780 781 - 782 782 Select Connection Channel List 783 783 784 784 Select Ethernet board communication 785 785 785 +[[image:image-20221115144824-10.png||height="421" width="705"]] 786 786 787 - 788 788 Select Ethernet Module 789 789 Set the IP address of the PLC 790 790 790 +[[image:image-20221115145228-11.png||height="674" width="708"]] 791 791 792 - 793 793 Read or write PLC data, in this document is read 794 794 794 +[[image:image-20221115145553-12.png||height="424" width="711"]] 795 795 796 +[[image:image-20221115145559-13.png||height="424" width="711"]] 796 796 797 -**V-BOX Communication Setting** 798 - 799 - 800 - 801 - 802 802 == **FX5U Serial Protocol** == 803 803 804 804 Mitsubishi FX5U series PLC ... ... @@ -953,10 +953,11 @@ 953 953 954 954 [[image:image-20220825112403-1.png||alt="图片-20220825112403-1.png"]] 955 955 956 -**5) Cable Wiring**952 +**5)电缆布线** 957 957 958 958 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 959 959 956 + 960 960 == **L02 Serial Protocol** == 961 961 962 962 Mitsubishi L02 series CPU built-in serial port.
- image-20221116105850-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Bob - Size
-
... ... @@ -1,1 +1,0 @@ 1 -18.9 KB - Content