... ... @@ -738,15 +738,14 @@
738 738  Set up the FX3U-ENET-L Ethernet module settings as follows.
739 739  Select the module location, which in this document is Module 0.
740 740  
741 +[[image:image-20221115140802-1.png]]
741 741  
742 -[[image:image-20221116105850-1.png]]
743 -
744 744  Select "Operational setting" to enter the following screen.
745 745  
746 746  The Ethernet module IP is set to 192.168.39.254 in this document, and other options are default.
747 747  
747 +[[image:image-20221115142728-4.png]]
748 748  
749 -
750 750  Select "Open setting" to enter the setting interface, the settings are as follows.
751 751  
752 752  The third item "Protocol" selects TCP, and "Open system" selects MELSOFT connection, which allows the
... ... @@ -753,8 +753,8 @@
753 753  
754 754  Mitsubishi programming software GX works2 to communicate with the FX3U via the Ethernet module.
755 755  
755 +[[image:image-20221115142945-5.png]]
756 756  
757 -
758 758  Click on "transter setup" - "PC side I/F setting", see the following figure.
759 759  
760 760  After setting, the first download must use the programming cable, as shown in the figure; after that, can
... ... @@ -761,16 +761,16 @@
761 761  
762 762  use the IP set in the "Ethernet board" to communicate directly with the network cable.
763 763  
763 +[[image:image-20221115143341-6.png||height="426" width="712"]]
764 764  
765 -
766 766  Read and write data from the Ethernet module
767 767  
767 +[[image:image-20221115143703-7.png]]
768 768  
769 -
770 770  Set "Transter setup" to COM communication, and read or write operation as shown below
771 771  
771 +[[image:image-20221115143809-8.png]]
772 772  
773 -
774 774  **PLC Settings (GX Works 2)**
775 775  
776 776  Create a blank FX5U project
... ... @@ -777,27 +777,32 @@
777 777  
778 778  Find Current Connection in the navigation
779 779  
779 +[[image:image-20221115144335-9.png||height="422" width="706"]]
780 780  
781 -
782 782  Select Connection Channel List
783 783  
784 784  Select Ethernet board communication
785 785  
785 +[[image:image-20221115144824-10.png||height="421" width="705"]]
786 786  
787 -
788 788  Select Ethernet Module
789 789  Set the IP address of the PLC
790 790  
790 +[[image:image-20221115145228-11.png||height="674" width="708"]]
791 791  
792 -
793 793  Read or write PLC data, in this document is read
794 794  
794 +[[image:image-20221115145553-12.png||height="424" width="711"]]
795 795  
796 +[[image:image-20221115145559-13.png||height="424" width="711"]]
796 796  
797 -**V-BOX Communication Setting**
798 +**HMI Communication Setting**
798 798  
800 +[[image:image-20221115150003-14.png||height="425" width="712"]]
799 799  
802 +[[image:image-20221115150235-15.png||height="427" width="713"]]
800 800  
804 +[[image:image-20221115145559-13.png||height="424" width="711"]]
801 801  
802 802  == **FX5U Serial Protocol** ==
803 803  
... ... @@ -953,10 +953,11 @@
953 953  
954 954  [[image:image-20220825112403-1.png||alt="图片-20220825112403-1.png"]]
955 955  
956 -**5)Cable Wiring**
960 +**5)电缆布线**
957 957  
958 958  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
959 959  
964 +
960 960  == **L02 Serial Protocol** ==
961 961  
962 962  Mitsubishi L02 series CPU built-in serial port.