Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 9 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki.B ob1 +XWiki.Ben - Content
-
... ... @@ -704,100 +704,6 @@ 704 704 [[image:image-20220825100845-4.png]] 705 705 706 706 707 -== **FX3U Ethernet Protocol** == 708 - 709 - Mitsubishi FX3U series PLC 710 - 711 -**1)HMI Settings** 712 - 713 -|Items|Settings|Note 714 -|Protocol|Mitsubishi FX3U| 715 -|Connection|Ethernet| 716 -|Port No.|5009|Must be the same as the PLC setting 717 -|PLC station No.|0| 718 - 719 -**2)Address List** 720 - 721 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 722 -|(% colspan="1" rowspan="7" %)Bit|X|X|X OOO|0~~377| 723 -|Y|Y|Y OOO|0~~377| 724 -|M|M|M DDDD|0~~7679| 725 -|SM|SM|SM DDDD|8000~~8511| 726 -|S|S|S DDDD|0~~4095| 727 -|TS|TS|TS DDD|0~~511| 728 -|CS|CS|CS DDD|0~~255| 729 -|(% colspan="1" rowspan="9" %)Word|CN|CN|CN DDD|0~~199| 730 -|TN|TN|TN DDD|0~~511| 731 -|D|D|D DDDD|0~~7999| 732 -|SD|SD|SD DDDD|8000~~8511| 733 -|R|R|R DDDDD|0~~32767| 734 - 735 -**3)Ethernet Module Settings** 736 - 737 -FX3U-ENET-L module configuration 738 -Set up the FX3U-ENET-L Ethernet module settings as follows. 739 -Select the module location, which in this document is Module 0. 740 - 741 -[[image:image-20221116105850-1.png]] 742 - 743 -Select "Operational setting" to enter the following screen. 744 - 745 -The Ethernet module IP is set to 192.168.39.254 in this document, and other options are default. 746 - 747 -[[image:image-20221116105947-1.png]] 748 - 749 -Select "Open setting" to enter the setting interface, the settings are as follows. 750 - 751 -The third item "Protocol" selects TCP, and "Open system" selects MELSOFT connection, which allows the 752 - 753 -Mitsubishi programming software GX works2 to communicate with the FX3U via the Ethernet module. 754 - 755 -[[image:image-20221116110802-1.png]] 756 - 757 -Click on "transter setup" - "PC side I/F setting", see the following figure. 758 - 759 -After setting, the first download must use the programming cable, as shown in the figure; after that, can 760 - 761 -use the IP set in the "Ethernet board" to communicate directly with the network cable. 762 - 763 -[[image:image-20221116110832-2.png||height="423" width="708"]] 764 - 765 -Read and write data from the Ethernet module 766 - 767 -[[image:image-20221116110907-3.png]] 768 - 769 -Set "Transter setup" to COM communication, and read or write operation as shown below 770 - 771 -[[image:image-20221116110917-4.png]] 772 - 773 -**4)PLC Settings (GX Works 2)** 774 - 775 -Create a blank FX5U project 776 - 777 -Find Current Connection in the navigation 778 - 779 - 780 - 781 -Select Connection Channel List 782 - 783 -Select Ethernet board communication 784 - 785 - 786 - 787 -Select Ethernet Module 788 -Set the IP address of the PLC 789 - 790 - 791 - 792 -Read or write PLC data, in this document is read 793 - 794 - 795 - 796 -**V-BOX Communication Setting** 797 - 798 - 799 - 800 - 801 801 == **FX5U Serial Protocol** == 802 802 803 803 Mitsubishi FX5U series PLC ... ... @@ -952,10 +952,11 @@ 952 952 953 953 [[image:image-20220825112403-1.png||alt="图片-20220825112403-1.png"]] 954 954 955 -**5) Cable Wiring**861 +**5)电缆布线** 956 956 957 957 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 958 958 865 + 959 959 == **L02 Serial Protocol** == 960 960 961 961 Mitsubishi L02 series CPU built-in serial port. ... ... @@ -1639,9 +1639,9 @@ 1639 1639 1640 1640 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 1641 1641 1642 -= Create communication with **Modbus ** = 1549 += Create communication with **Modbus RTU** = 1643 1643 1644 -== ** MODBUSRTUSlave(All function)** ==1551 +== **V-BOX as Slave** == 1645 1645 1646 1646 Select the protocol "Modbus RTU Slave (All Fuction)", 1647 1647 ... ... @@ -1650,7 +1650,7 @@ 1650 1650 (% style="text-align:center" %) 1651 1651 [[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]] 1652 1652 1653 -== ** MODBUSRTUMaster** ==1560 +== **V-BOX as Master** == 1654 1654 1655 1655 Select the protocol "Modbus RTU Master", 1656 1656 ... ... @@ -1686,61 +1686,6 @@ 1686 1686 |(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils) 1687 1687 |0F (Write multiple bits) 1688 1688 1689 -== **MODBUS TCP Slave (All function)** == 1690 - 1691 -Supported series: MODBUS TCP controller 1692 - 1693 -V-B0X works as MODBUS TCP MASTER connecting with TCP SLAVE 1694 - 1695 -**1)V-BOX Setting** 1696 - 1697 -|**Items**|**Settings**|**Note** 1698 -|Protocol|MODBUS TCP Slave (All function)| 1699 -|Connection|Ethernet| 1700 -|Port No.|502| 1701 -|PLC station No.|1 1702 - 1703 -**2)Address List** 1704 - 1705 -|**Type**|**Register**|**Function code & Description** 1706 -|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers) 1707 -|06 (write single register: write a binary value to a holding register) 1708 -|10 (write values to multiple addresses ) 1709 -|(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers) 1710 -|06 (write single register: write a binary value to a holding register) 1711 -|10 (write values to multiple addresses ) 1712 -|(% rowspan="3" %)W6|03 (read holding register: read current binary value in one or more holding registers) 1713 -|06 (write single register: write a binary value to a holding register) 1714 -|10 (write values to multiple addresses ) 1715 -|(% rowspan="2" %)W16|03 (read holding register: read current binary value in one or more holding registers) 1716 -|10 (write values to multiple addresses ) 1717 -|(% rowspan="11" %)Bit|(% rowspan="3" %)0|01 (Read coil state) 1718 -|05 (Force a single coil to force the on/off state of a logic coil) 1719 -|0F (Write multiple bits, ie write continuously) 1720 -|(% rowspan="3" %)1|02 (Read the input state) 1721 -|05 (Force a single coil to force the on/off state of a logic coil) 1722 -|0F (Write multiple bits) 1723 -|(% rowspan="3" %)W5|01 (Read coil state to obtain the current state of a set of logic coils) 1724 -|05 (Force a single coil to force the on/off state of a logic coil) 1725 -|0F (Write multiple bits) 1726 -|(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils) 1727 -|0F (Write multiple bits) 1728 - 1729 -**3)Communication Settings** 1730 - 1731 -Configure V-BOX Ethernet IP in Networking Settings 1732 - 1733 -[[image:image-20220902111833-3.png]] 1734 - 1735 - 1736 -Configure PLC Ethernet IP in Communication; 1737 - 1738 -[[image:image-20220902111121-1.png]] 1739 - 1740 -**4)Cable Wiring** 1741 - 1742 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 1743 - 1744 1744 == **communicate with VB inverter** == 1745 1745 1746 1746 [[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20VB%20inverter.zip]]
- image-20220902111121-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -60.9 KB - Content
- image-20220902111754-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -57.6 KB - Content
- image-20220902111833-3.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -56.1 KB - Content
- image-20221116105850-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Bob - Size
-
... ... @@ -1,1 +1,0 @@ 1 -18.9 KB - Content
- image-20221116105947-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Bob - Size
-
... ... @@ -1,1 +1,0 @@ 1 -18.7 KB - Content
- image-20221116110802-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Bob - Size
-
... ... @@ -1,1 +1,0 @@ 1 -16.4 KB - Content
- image-20221116110832-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Bob - Size
-
... ... @@ -1,1 +1,0 @@ 1 -42.2 KB - Content
- image-20221116110907-3.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Bob - Size
-
... ... @@ -1,1 +1,0 @@ 1 -17.8 KB - Content
- image-20221116110917-4.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Bob - Size
-
... ... @@ -1,1 +1,0 @@ 1 -23.2 KB - Content