... ... @@ -708,7 +708,7 @@
708 708  
709 709   Mitsubishi FX3U series PLC
710 710  
711 -**1)HMI Settings**
711 +**HMI Settings**
712 712  
713 713  |Items|Settings|Note
714 714  |Protocol|Mitsubishi FX3U|
... ... @@ -716,7 +716,7 @@
716 716  |Port No.|5009|Must be the same as the PLC setting
717 717  |PLC station No.|0|
718 718  
719 -**2)Address List**
719 +**Address List**
720 720  
721 721  |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
722 722  |(% colspan="1" rowspan="7" %)Bit|X|X|X OOO|0~~377|
... ... @@ -732,20 +732,22 @@
732 732  |SD|SD|SD DDDD|8000~~8511|
733 733  |R|R|R DDDDD|0~~32767|
734 734  
735 -**3)Ethernet Module Settings**
735 +**Ethernet Module Settings**
736 736  
737 737  FX3U-ENET-L module configuration
738 738  Set up the FX3U-ENET-L Ethernet module settings as follows.
739 739  Select the module location, which in this document is Module 0.
740 740  
741 -[[image:image-20221116105850-1.png]]
741 +[[image:image-20221116094003-1.png]]
742 742  
743 +
743 743  Select "Operational setting" to enter the following screen.
744 744  
745 745  The Ethernet module IP is set to 192.168.39.254 in this document, and other options are default.
746 746  
747 -[[image:image-20221116105947-1.png]]
748 +[[image:image-20221116094019-2.png]]
748 748  
750 +
749 749  Select "Open setting" to enter the setting interface, the settings are as follows.
750 750  
751 751  The third item "Protocol" selects TCP, and "Open system" selects MELSOFT connection, which allows the
... ... @@ -752,8 +752,9 @@
752 752  
753 753  Mitsubishi programming software GX works2 to communicate with the FX3U via the Ethernet module.
754 754  
755 -[[image:image-20221116110802-1.png]]
757 +[[image:image-20221116094038-3.png]]
756 756  
759 +
757 757  Click on "transter setup" - "PC side I/F setting", see the following figure.
758 758  
759 759  After setting, the first download must use the programming cable, as shown in the figure; after that, can
... ... @@ -760,22 +760,26 @@
760 760  
761 761  use the IP set in the "Ethernet board" to communicate directly with the network cable.
762 762  
763 -[[image:image-20221116110832-2.png||height="423" width="708"]]
766 +[[image:image-20221116094122-4.png||height="422" width="707"]]
764 764  
768 +
765 765  Read and write data from the Ethernet module
766 766  
767 -[[image:image-20221116110907-3.png]]
771 +[[image:image-20221116094131-5.png||height="551" width="708"]]
768 768  
773 +
769 769  Set "Transter setup" to COM communication, and read or write operation as shown below
770 770  
771 -[[image:image-20221116110917-4.png]]
776 +[[image:image-20221116094150-6.png]]
772 772  
773 -**4)PLC Settings (GX Works 2)**
774 774  
779 +**PLC Settings (GX Works 2)**
780 +
775 775  Create a blank FX5U project
776 776  
777 777  Find Current Connection in the navigation
778 778  
785 +[[image:image-20221116094206-7.png||height="425" width="711"]]
779 779  
780 780  
781 781  Select Connection Channel List
... ... @@ -782,20 +782,25 @@
782 782  
783 783  Select Ethernet board communication
784 784  
792 +[[image:image-20221116094709-9.png||height="427" width="715"]]
785 785  
786 786  
787 787  Select Ethernet Module
788 788  Set the IP address of the PLC
789 789  
798 +[[image:image-20221116094736-11.png||height="682" width="716"]]
790 790  
791 791  
792 792  Read or write PLC data, in this document is read
793 793  
803 +[[image:image-20221116094755-12.png||height="426" width="715"]]
794 794  
805 +[[image:image-20221116094803-13.png||height="427" width="715"]]
795 795  
796 796  **V-BOX Communication Setting**
797 797  
798 798  
810 +
799 799  
800 800  
801 801  == **FX5U Serial Protocol** ==
... ... @@ -952,10 +952,11 @@
952 952  
953 953  [[image:image-20220825112403-1.png||alt="图片-20220825112403-1.png"]]
954 954  
955 -**5)Cable Wiring**
967 +**5)电缆布线**
956 956  
957 957  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
958 958  
971 +
959 959  == **L02 Serial Protocol** ==
960 960  
961 961  Mitsubishi L02 series CPU built-in serial port.
image-20221116105850-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -18.9 KB
Content
image-20221116105947-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -18.7 KB
Content
image-20221116110802-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -16.4 KB
Content
image-20221116110832-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -42.2 KB
Content
image-20221116110907-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -17.8 KB
Content
image-20221116110917-4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bob
Size
... ... @@ -1,1 +1,0 @@
1 -23.2 KB
Content