... ... @@ -706,9 +706,9 @@
706 706  
707 707  == **FX3U Ethernet Protocol** ==
708 708  
709 - Mitsubishi FX3U series PLC
709 +Supported ModulesFX3U-ENET-ADP, FX3U-ENET-L
710 710  
711 -**1)HMI Settings**
711 +**1)V-BOX Settings**
712 712  
713 713  |Items|Settings|Note
714 714  |Protocol|Mitsubishi FX3U|
... ... @@ -797,10 +797,8 @@
797 797  
798 798  **4)Configure the communication protocol**
799 799  
800 -[[image:image-20221116114106-1.png||height="397" width="701"]]
800 +[[image:image-20221119101946-2.png||height="395" width="695"]]
801 801  
802 -
803 -
804 804  == **FX5U Serial Protocol** ==
805 805  
806 806  Mitsubishi FX5U series PLC
... ... @@ -1140,10 +1140,13 @@
1140 1140  
1141 1141  * Click [Ethernet/CC IE/MELSECNET];
1142 1142  * Please select [Ethernet] as network type;
1143 -* Set station I/O number according to situation (For example, 0000 means that the module is connected to PLC CPU in first order);
1141 +* Set station I/O number according to situation (For example, 0020 means that the module is connected to PLC CPU in first order);
1144 1144  * Select [Online] as Mode;
1143 +* [[image:image-20221119171343-2.png||height="341" width="587"]]
1145 1145  * Click [Operation setting] to set IP;
1146 1146  * Select [Binary Code] as [Communication Data Code];
1146 +* [[image:image-20221119171436-3.png||height="354" width="588"]]
1147 +* Click [Open setting]
1147 1147  * Set protocol: TCP;
1148 1148  * Set [unpassive] in [Open system];
1149 1149  * Set [receive] in [Fixed buffer];
... ... @@ -1150,14 +1150,16 @@
1150 1150  * Set [procedure Exist] in [Fixed buffer communication];
1151 1151  * Disable [Pairing open];
1152 1152  * Set [No confirm] in [Existence confirmation];
1153 -* Host station port number: 1025;
1154 +* Host station port number: 5009;
1154 1154  * Save settings;
1156 +* [[image:image-20221119171611-4.png||height="354" width="588"]]
1155 1155  * Download project into PLC and restart it
1156 1156  
1157 1157  **4)Configure the communication protocol**
1158 1158  
1159 -[[image:image-20220825143728-1.png]]
1161 +[[image:image-20221119171832-5.png||height="354" width="625"]]
1160 1160  
1163 +
1161 1161  **5)Cable Wiring**
1162 1162  
1163 1163  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png"]]
image-20221119101759-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +62.1 KB
Content
image-20221119101946-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +68.7 KB
Content
image-20221119171318-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +90.3 KB
Content
image-20221119171343-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +90.3 KB
Content
image-20221119171436-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +43.4 KB
Content
image-20221119171611-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +23.1 KB
Content
image-20221119171832-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +69.6 KB
Content