Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 7 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -706,9 +706,9 @@ 706 706 707 707 == **FX3U Ethernet Protocol** == 708 708 709 - M itsubishiFX3UseriesPLC709 +Supported Modules: FX3U-ENET-ADP, FX3U-ENET-L 710 710 711 -**1) HMISettings**711 +**1)V-BOX Settings** 712 712 713 713 |Items|Settings|Note 714 714 |Protocol|Mitsubishi FX3U| ... ... @@ -797,10 +797,8 @@ 797 797 798 798 **4)Configure the communication protocol** 799 799 800 -[[image:image-2022111 6114106-1.png||height="397" width="701"]]800 +[[image:image-20221119101946-2.png||height="395" width="695"]] 801 801 802 - 803 - 804 804 == **FX5U Serial Protocol** == 805 805 806 806 Mitsubishi FX5U series PLC ... ... @@ -1140,10 +1140,13 @@ 1140 1140 1141 1141 * Click [Ethernet/CC IE/MELSECNET]; 1142 1142 * Please select [Ethernet] as network type; 1143 -* Set station I/O number according to situation (For example, 000 0means that the module is connected to PLC CPU in first order);1141 +* Set station I/O number according to situation (For example, 0020 means that the module is connected to PLC CPU in first order); 1144 1144 * Select [Online] as Mode; 1143 +* [[image:image-20221119171343-2.png||height="341" width="587"]] 1145 1145 * Click [Operation setting] to set IP; 1146 1146 * Select [Binary Code] as [Communication Data Code]; 1146 +* [[image:image-20221119171436-3.png||height="354" width="588"]] 1147 +* Click [Open setting] 1147 1147 * Set protocol: TCP; 1148 1148 * Set [unpassive] in [Open system]; 1149 1149 * Set [receive] in [Fixed buffer]; ... ... @@ -1150,14 +1150,16 @@ 1150 1150 * Set [procedure Exist] in [Fixed buffer communication]; 1151 1151 * Disable [Pairing open]; 1152 1152 * Set [No confirm] in [Existence confirmation]; 1153 -* Host station port number: 1025;1154 +* Host station port number: 5009; 1154 1154 * Save settings; 1156 +* [[image:image-20221119171611-4.png||height="354" width="588"]] 1155 1155 * Download project into PLC and restart it 1156 1156 1157 1157 **4)Configure the communication protocol** 1158 1158 1159 -[[image:image-2022 0825143728-1.png]]1161 +[[image:image-20221119171832-5.png||height="354" width="625"]] 1160 1160 1163 + 1161 1161 **5)Cable Wiring** 1162 1162 1163 1163 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png"]]
- image-20221119101759-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bob - Size
-
... ... @@ -1,0 +1,1 @@ 1 +62.1 KB - Content
- image-20221119101946-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bob - Size
-
... ... @@ -1,0 +1,1 @@ 1 +68.7 KB - Content
- image-20221119171318-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bob - Size
-
... ... @@ -1,0 +1,1 @@ 1 +90.3 KB - Content
- image-20221119171343-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bob - Size
-
... ... @@ -1,0 +1,1 @@ 1 +90.3 KB - Content
- image-20221119171436-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bob - Size
-
... ... @@ -1,0 +1,1 @@ 1 +43.4 KB - Content
- image-20221119171611-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bob - Size
-
... ... @@ -1,0 +1,1 @@ 1 +23.1 KB - Content
- image-20221119171832-5.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bob - Size
-
... ... @@ -1,0 +1,1 @@ 1 +69.6 KB - Content