Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
To version 20.1
edited by Ben
on 2022/08/20 11:42
on 2022/08/20 11:42
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Stone1 +XWiki.Ben - Content
-
... ... @@ -47,15 +47,204 @@ 47 47 |(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils) 48 48 |0F (Write multiple bits) 49 49 50 -= =**WECONLX3VPLC** ==50 += ** WECON PLC** = 51 51 52 -S elect theprotocol(% class="mark"%)"WECON LX3V"52 +Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM 53 53 54 - (%class="mark" %)then setBaudRate,Port,Stop Bit,Data Bit,Paritysame with PLC.54 +**HMI Settings** 55 55 56 -(% class="mark" %)WECON PLC RS422 port,default communication parameters is 9600,1,7,ZEVEN 56 +|**Item**|**Settings**|**Note** 57 +|Protocol|WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM| 58 +|Connection|RS422/RS485| 59 +|Baud rate|9600| 60 +|Data bit|7| 61 +|Parity|EVEN| 62 +|Stop bit|1| 63 +|PLC station No.|1| 57 57 65 +**Address List** 66 + 67 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 68 +|(% rowspan="6" %)Bit|X|X|Xo|0~~303237| 69 +|Y|Y|Y o|0~~303237| 70 +|M|M|M d|0~~99999| 71 +|T|T|T d|0~~99999| 72 +|C|C|C d|0~~99999| 73 +|S|S|S d|0~~99999| 74 +|(% rowspan="8" %)Word|X|X|Xo|0~~303237| 75 +|Y|Y|Y o|0~~303237| 76 +|M|M|M d|0~~99999| 77 +|T|T|T d|0~~99999| 78 +|C|C|C d|0~~199| 79 +|D|D|D d|0~~7999| 80 +|S|S|S d|0~~99999| 81 +|SD|SD|SD d|8000~~9999| 82 + 83 +**Cable Wiring** 84 + 85 +* **RS485** 86 + 58 58 (% style="text-align:center" %) 88 +[[image:12.PLC Protocol_html_5e9a81a14106da9e.png||data-xwiki-image-style-alignment="center" height="223" width="392" class="img-thumbnail"]] 89 + 90 +(% style="text-align:center" %) 91 +[[image:12.PLC Protocol_html_1897d92be6948d58.png||data-xwiki-image-style-alignment="center" height="223" width="393" class="img-thumbnail"]] 92 + 93 +* **RS422** 94 + 95 +(% style="text-align:center" %) 96 +[[image:12.PLC Protocol_html_5c7fca9a70da2ee8.png||data-xwiki-image-style-alignment="center" height="247" width="389" class="img-thumbnail"]] 97 + 98 +**✎Note:** 99 + 100 +* HMI COM3 is available in PI8000 series and COM3 is in COM2(hardware PIN 7 and PIN 8) . 101 +* If PLC <= 20 points,such as LX3V-1208/LX3V-0806 PLC,PLC RS485A and RS485B mean PLC COM2 RS485+ and RS485- .PLC COM2 can support modbus. Please refer to PLC COM2 setting manual. 102 + 103 +[[https:~~/~~/drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing>>url:https://drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing]] 104 + 105 +== HMI and Wecon LX5V serial communication == 106 + 107 +This example introduces the establishment of serial port communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 108 + 109 +**Software configuration of PLC** 110 + 111 +**1)PLC programming software** 112 + 113 +[[image:image-20220810164710-1.png]] 114 + 115 +**2)New PLC project** 116 + 117 +Click New Project and select the PLC model. 118 + 119 +[[image:image-20220810172412-1.png]] 120 + 121 +**3)Set Serial port parameters** 122 + 123 +Follow the steps below to configure Serial port parameters 124 + 125 +Baud rate:115200 126 + 127 +Data bit:8 128 + 129 +Stop bit:1 130 + 131 +Parity:No verification 132 + 133 +[[image:image-20220810165759-3.png]] 134 + 135 +**4)Registers list** 136 + 137 +[[image:image-20220811102219-3.png]] 138 + 139 +**HMI software configuration** 140 + 141 +**1)HMI programming software** 142 + 143 + [[image:image-20220810171237-4.png]] 144 + 145 +**2)New HMI project** 146 + 147 +Click New Project and select the HMI model. 148 + 149 +[[image:image-20220810172010-5.png]] 150 + 151 +**3)Set communication port parameters** 152 + 153 +Click the communication configuration button on the left to find the communication protocol with LX5V. After selecting the protocol, configure the communication parameters of the COM port. 154 + 155 +Baud rate:115200 156 + 157 +Data bit:8 158 + 159 +Stop bit:1 160 + 161 +Parity:No verification 162 + 163 +[[image:image-20220811104012-1.png]] 164 + 165 +**hardware connection** 166 + 167 +**1)Hardware wiring diagram** 168 + 169 +This example introduces WeconHMI with LX5V PLC to establish communication through serial port. The connection diagram is as follows: 170 + 171 +[[image:image-20220811103005-4.png]] 172 + 173 +[[image:image-20220811103227-7.png]] 174 + 175 +The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC. 176 + 177 +== HMI and Wecon LX5V-N Ethernet communication == 178 + 179 + This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 180 + 181 +**Software configuration of PLC** 182 + 183 +**1)PLC programming software** 184 + 185 +[[image:image-20220810164710-1.png]] 186 + 187 +**2)New PLC project** 188 + 189 +Click New Project and select the PLC model. 190 + 191 +[[image:image-20220811115454-1.png]] 192 + 193 +**3)Set Ethernet port parameters** 194 + 195 +Follow the steps below to configure Ethernet parameters 196 + 197 +PLC IP address:192.168.39.200 198 + 199 +default gateway:192.168.39.1 200 + 201 +subnet mask:255.255.255.0 202 + 203 +[[image:image-20220811140530-2.png]] 204 + 205 +**4)Registers list** 206 + 207 +[[image:image-20220811102219-3.png]] 208 + 209 +**HMI software configuration** 210 + 211 +**1)HMI programming software** 212 + 213 + [[image:image-20220810171237-4.png]] 214 + 215 +**2)New HMI project** 216 + 217 +Click New Project and select the HMI model. 218 + 219 +[[image:image-20220810172010-5.png]] 220 + 221 +**3)Set communication port parameters** 222 + 223 +Click the project setting button on the left to configure the IP address of the HMI machine to ensure that the HMI and PLC IP remain in a local area network. 224 + 225 +HMI IP address:192.168.39.201 226 + 227 +default gateway:192.168.39.1 228 + 229 +subnet mask:255.255.255.0 230 + 231 +[[image:image-20220811170753-2.png]] 232 + 233 +Next, click Communication Settings to configure the IP of the HMI communication object. 234 + 235 +[[image:image-20220811163047-1.png]] 236 + 237 +**hardware connection** 238 + 239 +**1)Hardware wiring diagram** 240 + 241 +This example introduces WeconHMI with LX5V-N PLC to establish communication through ethernet. The connection diagram is as follows: 242 + 243 +[[image:image-20220811170248-1.png]] 244 + 245 +The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC. 246 + 247 +(% style="text-align:center" %) 59 59 [[image:1624348978863-771.png||queryString="width=812&height=494" height="487" width="800" class="img-thumbnail"]] 60 60 61 61 == **2 Communication with Allen-Bradley CompactLogix L1769** == ... ... @@ -302,7 +302,7 @@ 302 302 303 303 = **2 User define protocol** = 304 304 305 -More serial port script instruction,please refer manual:[[Lua script function>>doc:V-BOX.V-Net.04 Lua Script.01 Lua Functions.WebHome]]~-~-->[[3.Serial port operation>>url:http://docs.we-con.com.cn/wiki/vbox/view/HMI/04.Lua%20script%20%20function%20and%20operation/01.Lua%20script%20function/#H3.Serialportoperation]] 494 +More serial port script instruction,please refer manual:[[Lua script function>>doc:V-BOX.V-Net.Manual.04 Lua Script.01 Lua Functions.WebHome]]~-~-->[[3.Serial port operation>>url:http://docs.we-con.com.cn/wiki/vbox/view/HMI/04.Lua%20script%20%20function%20and%20operation/01.Lua%20script%20function/#H3.Serialportoperation]] 306 306 307 307 == **Read the temperature sensor.** == 308 308