Changes for page 1 Communication

Last modified by Hunter on 2024/07/01 10:54

From version 18.1
edited by Stone Wu
on 2022/07/25 11:32
Change comment: Renamed back-links.
To version 50.1
edited by Ben
on 2022/08/24 11:33
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Stone
1 +XWiki.Ben
Content
... ... @@ -1,71 +1,279 @@
1 -= **1 General communication with PLC** =
1 += =
2 2  
3 -== **Modbus RTU** ==
3 +(% class="table-bordered" %)
4 +| | |
5 +|(% rowspan="11" %) |(% rowspan="3" %) |
6 +|
7 +|
8 +|(% rowspan="3" %) |
9 +|
10 +|
11 +|(% rowspan="3" %) |
12 +|
13 +|
14 +|(% rowspan="2" %) |
15 +|
16 +|(% rowspan="11" %) |(% rowspan="3" %) |
17 +|
18 +|
19 +|(% rowspan="3" %) |
20 +|
21 +|
22 +|(% rowspan="3" %) |
23 +|
24 +|
25 +|(% rowspan="2" %) |
26 +|
4 4  
5 -=== **V-BOX as master** ===
28 += **WECON PLC** =
6 6  
7 -Select the protocol “(% class="mark" %)Modbus RTU Slave(All Fuction)”,
30 +== **LX3V 串行通信** ==
8 8  
9 -(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity
32 +Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM
10 10  
11 -(% style="text-align:center" %)
12 -[[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]]
34 +**HMI Settings**
13 13  
14 -=== **V-BOX as slave** ===
36 +|**Item**|**Settings**|**Note**
37 +|Protocol|WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM|
38 +|Connection|RS422/RS485|
39 +|Baud rate|9600|
40 +|Data bit|7|
41 +|Parity|EVEN|
42 +|Stop bit|1|
43 +|PLC station No.|1|
15 15  
16 -Select the protocol “(% class="mark" %)**Modbus RTU Master”**,
45 +**Address List**
17 17  
18 -(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity
47 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
48 +|(% rowspan="6" %)Bit|X|X|Xo|0~~303237|
49 +|Y|Y|Y o|0~~303237|
50 +|M|M|M d|0~~99999|
51 +|T|T|T d|0~~99999|
52 +|C|C|C d|0~~99999|
53 +|S|S|S d|0~~99999|
54 +|(% rowspan="8" %)Word|X|X|Xo|0~~303237|
55 +|Y|Y|Y o|0~~303237|
56 +|M|M|M d|0~~99999|
57 +|T|T|T d|0~~99999|
58 +|C|C|C d|0~~199|
59 +|D|D|D d|0~~7999|
60 +|S|S|S d|0~~99999|
61 +|SD|SD|SD d|8000~~9999|
19 19  
20 -(% style="text-align:center" %)
21 -[[image:1624348709622-711.png||queryString="width=809&height=493" height="488" width="800" class="img-thumbnail"]]
63 +**Cable Wiring**
22 22  
23 -**Address List**
65 +* **RS485**
24 24  
25 -(% class="table-bordered" %)
26 -|**Type**|**Register**|**Function code & Description**
27 -|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers)
28 -|06 (write single register: write a binary value to a holding register)
29 -|10 (write values to multiple addresses )
30 -|(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers)
31 -|06 (write single register: write a binary value to a holding register)
32 -|10 (write values to multiple addresses )
33 -|(% rowspan="3" %)W6|03 (read holding register: read current binary value in one or more holding registers)
34 -|06 (write single register: write a binary value to a holding register)
35 -|10 (write values to multiple addresses )
36 -|(% rowspan="2" %)W16|03 (read holding register: read current binary value in one or more holding registers)
37 -|10 (write values to multiple addresses )
38 -|(% rowspan="11" %)Bit|(% rowspan="3" %)0|01 (Read coil state)
39 -|05 (Force a single coil to force the on/off state of a logic coil)
40 -|0F (Write multiple bits, ie write continuously)
41 -|(% rowspan="3" %)1|02 (Read the input state)
42 -|05 (Force a single coil to force the on/off state of a logic coil)
43 -|0F (Write multiple bits)
44 -|(% rowspan="3" %)W5|01 (Read coil state to obtain the current state of a set of logic coils)
45 -|05 (Force a single coil to force the on/off state of a logic coil)
46 -|0F (Write multiple bits)
47 -|(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils)
48 -|0F (Write multiple bits)
67 + [[image:image-20220822172124-1.png]]
49 49  
50 -== **WECON LX3V PLC** ==
69 +* **RS422**
51 51  
52 -Select the protocol (% class="mark" %)"WECON LX3V"
71 + [[image:image-20220822172228-2.png]]
53 53  
54 -(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity same with PLC.
55 55  
56 -(% class="mark" %)WECON PLC RS422 port,default communication parameters is 9600,1,7,ZEVEN
74 +**✎Note:**
57 57  
76 +* HMI COM3 is available in PI8000 series and COM3 is in COM2(hardware PIN 7 and PIN 8) .
77 +* If PLC <= 20 points,such as LX3V-1208/LX3V-0806 PLC,PLC RS485A and RS485B mean PLC COM2 RS485+ and RS485- .PLC COM2 can support modbus. Please refer to PLC COM2 setting manual.
78 +
79 +[[https:~~/~~/drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing>>url:https://drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing]]
80 +
81 +== **LX5V serial communication** ==
82 +
83 +This example introduces the establishment of serial port communication between Wecon V-BOX and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
84 +
85 +**Software configuration of PLC**
86 +
87 +**1)PLC programming software**
88 +
89 +[[image:image-20220822172553-1.png]]
90 +
91 +**2)New PLC project**
92 +
93 +Click New Project and select the PLC model.
94 +
95 +[[image:image-20220822172623-2.png]]
96 +
97 +**3)Set Serial port parameters**
98 +
99 +Follow the steps below to configure Serial port parameters
100 +
101 +Baud rate:115200
102 +
103 +Data bit:8
104 +
105 +Stop bit:1
106 +
107 +Parity:No verification
108 +
109 +[[image:image-20220822172657-3.png]]
110 +
111 +**4)Registers list**
112 +
113 +[[image:image-20220822172730-4.png]]
114 +
115 +**V-BOX software configuration**
116 +
117 +**1)V-BOX programming software**
118 +
119 + [[image:image-20220824104124-1.png]]
120 +
121 +**2)V-NET add device**
122 +
123 +Open V-NET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the access key, password and remark, to add the device.
124 +
125 +[[image:image-20220824104909-2.png]]
126 +
127 +
128 +**3)Set communication port parameters**
129 +
130 +Click the communication configuration button on the left to find the communication protocol with LX5V. After selecting the protocol, configure the communication parameters of the COM port.
131 +
132 +Baud rate:115200
133 +
134 +Data bit:8
135 +
136 +Stop bit:1
137 +
138 +Parity:No verification
139 +
140 +[[image:image-20220811104012-1.png]]
141 +
142 +
143 +**hardware connection**
144 +
145 +**1)Hardware wiring diagram**
146 +
147 +This example introduces WeconHMI with LX5V PLC to establish communication through serial port. The connection diagram is as follows:
148 +
149 +
150 +
151 +[[image:image-20220811103005-4.png]]
152 +
153 +[[image:image-20220811103227-7.png]]
154 +
155 +The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC.
156 +
157 +== **LX5V-N Ethernet communication** ==
158 +
159 + This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
160 +
161 +**Software configuration of PLC**
162 +
163 +**1)PLC programming software**
164 +
165 +[[image:image-20220810164710-1.png]]
166 +
167 +**2)New PLC project**
168 +
169 +Click New Project and select the PLC model.
170 +
171 +[[image:image-20220811115454-1.png]]
172 +
173 +**3)Set Ethernet port parameters**
174 +
175 +Follow the steps below to configure Ethernet parameters
176 +
177 +PLC IP address:192.168.39.200
178 +
179 +default gateway:192.168.39.1
180 +
181 +subnet mask:255.255.255.0
182 +
183 +[[image:image-20220811140530-2.png]]
184 +
185 +**4)Registers list**
186 +
187 +[[image:image-20220811102219-3.png]]
188 +
189 +**HMI software configuration**
190 +
191 +**1)HMI programming software**
192 +
193 + [[image:image-20220810171237-4.png]]
194 +
195 +**2)New HMI project**
196 +
197 +Click New Project and select the HMI model.
198 +
199 +[[image:image-20220810172010-5.png]]
200 +
201 +**3)Set communication port parameters**
202 +
203 +Click the project setting button on the left to configure the IP address of the HMI machine to ensure that the HMI and PLC IP remain in a local area network.
204 +
205 +HMI IP address:192.168.39.201
206 +
207 +default gateway:192.168.39.1
208 +
209 +subnet mask:255.255.255.0
210 +
211 +[[image:image-20220811170753-2.png]]
212 +
213 +Next, click Communication Settings to configure the IP of the HMI communication object.
214 +
215 +[[image:image-20220811163047-1.png]]
216 +
217 +**hardware connection**
218 +
219 +**1)Hardware wiring diagram**
220 +
221 +This example introduces WeconHMI with LX5V-N PLC to establish communication through ethernet. The connection diagram is as follows:
222 +
223 +[[image:image-20220811170248-1.png]]
224 +
225 +The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC.
226 +
58 58  (% style="text-align:center" %)
59 59  [[image:1624348978863-771.png||queryString="width=812&height=494" height="487" width="800" class="img-thumbnail"]]
60 60  
61 -== **2 Communication with Allen-Bradley CompactLogix L1769** ==
230 += **Rockwell PLC** =
62 62  
232 +== (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix** ==
233 +
234 +MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
235 +
236 +**HMI Settings**
237 +
238 +|**Item**|**Settings**|**Note**
239 +|Protocol|Allen-Bradlley MicroLogix|
240 +|Connection|RS232|
241 +|Baud rate|19200|
242 +|Data bit|8|
243 +|Parity|None|
244 +|Stop bit|1|
245 +|PLC station No.|1|
246 +
247 +**Address List**
248 +
249 +|**Type**|**Device registers**|**Format**|**Range**|**Note**
250 +|(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15|
251 +|O|O d.d|0.0~~255.15|
252 +|B|B nnhh.dd|0.0~~ffff.15|nn: block number (hex)
253 +|S|S d.d|0.0~~255.15|
254 +|N|N nnhh.dd|0.0~~ffff.15|nn: block number (hex)
255 +|(% rowspan="9" %)Word|S|S d|0~~255|
256 +|TS|TS nnhh|0~~ffff|(% rowspan="8" %)nn: block number (hex)
257 +|TP|TP nnhh|0~~ffff
258 +|CS|CS nnhh|0~~ffff
259 +|CP|CP nnhh|0~~ffff
260 +|N|N nnhh|0~~ffff
261 +|C|C nnhh|0~~ffff
262 +|T|T nnhh|0~~ffff
263 +|R|R nnhh|0~~ffff
264 +
265 +**Cable Wiring**
266 +
267 +[[image:image-20220824110724-1.png]]
268 +
269 +
270 +
271 +== **CompactLogix** ==
272 +
63 63  (((
64 64  (((
65 -This example introduces the establishment of Ethernet communication between Wecon V-box and Allen-Bradley L1769. It is introduced through three parts: PLC software configuration, V-box software configuration, and hardware wiring.
275 +This example introduces the establishment of Ethernet communication between Wecon V-box and CompactLogix L1769. It is introduced through three parts: PLC software configuration, V-box software configuration, and hardware wiring.
66 66  )))
67 -
68 -
69 69  )))
70 70  
71 71  (((
... ... @@ -199,7 +199,7 @@
199 199  
200 200  (((
201 201  (((
202 -Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device.   ​​​​​​​[[image:image-20220714162752-8.png]]
410 +Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device.   [[image:image-20220714162752-8.png]]
203 203  )))
204 204  
205 205  
... ... @@ -226,7 +226,7 @@
226 226  
227 227  
228 228  (((
229 -After adding the protocol Allen-BradleyMicro850_FreeTag, click[[image:image-20220714143838-2.png]]icon add label.​​​​​​​[[image:image-20220714162827-11.png]]
437 +After adding the protocol Allen-BradleyMicro850_FreeTag, click[[image:image-20220714143838-2.png]]icon add label.[[image:image-20220714162827-11.png]]
230 230  )))
231 231  
232 232  (% class="wikigeneratedid" id="HEngineeringproduction" %)
... ... @@ -260,7 +260,15 @@
260 260  [[image:image-20220714162856-13.png]]
261 261  
262 262  (((
263 -The above are all the steps for establishing Ethernet communication between Wecon V-box with Allen-Bradley L1769 PLC.
471 +The above are all the steps for establishing Ethernet communication between Wecon V-box with CompactLogix L1769 PLC.
472 +
473 +
474 +== **Allen-Bradley Ethernet DF1** ==
475 +
476 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]]
477 +
478 +
479 += **Siemens PLC** =
264 264  )))
265 265  )))
266 266  
... ... @@ -268,14 +268,12 @@
268 268  
269 269  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]]
270 270  
271 -== **Allen-Bradley Ethernet DF1** ==
272 -
273 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]]
274 -
275 275  == **Communication with S7-200 Smart** ==
276 276  
277 277  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]]
278 278  
491 += **Delta PLC** =
492 +
279 279  == **Delta DVP Ethernet** ==
280 280  
281 281  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
... ... @@ -284,6 +284,8 @@
284 284  
285 285  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
286 286  
501 += **Mitsubishi PLC** =
502 +
287 287  == **Communicate with Mitsubishi FX Series** ==
288 288  
289 289  [[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20Mitsubishi%20FX%20Series.zip]]
... ... @@ -292,6 +292,8 @@
292 292  
293 293  [[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20VB%20inverter.zip]]
294 294  
511 += **Omron PLC** =
512 +
295 295  == **Omron CP1 Series** ==
296 296  
297 297  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]]
... ... @@ -300,9 +300,57 @@
300 300  
301 301  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]]
302 302  
521 +
522 += **Modbus RTU** =
523 +
524 +=== **V-BOX as master** ===
525 +
526 +Select the protocol “(% class="mark" %)Modbus RTU Slave(All Fuction)”,
527 +
528 +(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity
529 +
530 +(% style="text-align:center" %)
531 +[[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]]
532 +
533 +=== **V-BOX as slave** ===
534 +
535 +Select the protocol “(% class="mark" %)**Modbus RTU Master”**,
536 +
537 +(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity
538 +
539 +(% style="text-align:center" %)
540 +[[image:1624348709622-711.png||queryString="width=809&height=493" height="488" width="800" class="img-thumbnail"]]
541 +
542 +**Address List**
543 +
544 +(% class="table-bordered" %)
545 +|**Type**|**Register**|**Function code & Description**
546 +|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers)
547 +|06 (write single register: write a binary value to a holding register)
548 +|10 (write values to multiple addresses )
549 +|(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers)
550 +|06 (write single register: write a binary value to a holding register)
551 +|10 (write values to multiple addresses )
552 +|(% rowspan="3" %)W6|03 (read holding register: read current binary value in one or more holding registers)
553 +|06 (write single register: write a binary value to a holding register)
554 +|10 (write values to multiple addresses )
555 +|(% rowspan="2" %)W16|03 (read holding register: read current binary value in one or more holding registers)
556 +|10 (write values to multiple addresses )
557 +|(% rowspan="11" %)Bit|(% rowspan="3" %)0|01 (Read coil state)
558 +|05 (Force a single coil to force the on/off state of a logic coil)
559 +|0F (Write multiple bits, ie write continuously)
560 +|(% rowspan="3" %)1|02 (Read the input state)
561 +|05 (Force a single coil to force the on/off state of a logic coil)
562 +|0F (Write multiple bits)
563 +|(% rowspan="3" %)W5|01 (Read coil state to obtain the current state of a set of logic coils)
564 +|05 (Force a single coil to force the on/off state of a logic coil)
565 +|0F (Write multiple bits)
566 +|(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils)
567 +|0F (Write multiple bits)
568 +
303 303  = **2 User define protocol** =
304 304  
305 -More serial port script instruction,please refer manual:[[Lua script function>>doc:V-BOX.V-Net.04 Lua Script.01 Lua Functions.WebHome]]~-~-->[[3.Serial port operation>>url:http://docs.we-con.com.cn/wiki/vbox/view/HMI/04.Lua%20script%20%20function%20and%20operation/01.Lua%20script%20function/#H3.Serialportoperation]]
571 +More serial port script instruction,please refer manual:[[Lua script function>>doc:V-BOX.V-Net.Manual.04 Lua Script.01 Lua Functions.WebHome]]~-~-->[[3.Serial port operation>>url:http://docs.we-con.com.cn/wiki/vbox/view/HMI/04.Lua%20script%20%20function%20and%20operation/01.Lua%20script%20function/#H3.Serialportoperation]]
306 306  
307 307  == **Read the temperature sensor.** ==
308 308  
image-20220820164423-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +18.4 KB
Content
image-20220822172124-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +38.7 KB
Content
image-20220822172228-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +48.8 KB
Content
image-20220822172553-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +19.9 KB
Content
image-20220822172623-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +111.2 KB
Content
image-20220822172657-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +141.6 KB
Content
image-20220822172730-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +130.7 KB
Content
image-20220824104124-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +14.6 KB
Content
image-20220824104909-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +278.8 KB
Content
image-20220824110724-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +79.1 KB