Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
To version 32.1
edited by Ben
on 2022/08/22 17:23
on 2022/08/22 17:23
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 3 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Stone1 +XWiki.Ben - Content
-
... ... @@ -1,7 +1,5 @@ 1 -= ** 1 General communicationwith PLC** =1 += **Modbus RTU** = 2 2 3 -== **Modbus RTU** == 4 - 5 5 === **V-BOX as master** === 6 6 7 7 Select the protocol “(% class="mark" %)Modbus RTU Slave(All Fuction)”, ... ... @@ -47,19 +47,217 @@ 47 47 |(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils) 48 48 |0F (Write multiple bits) 49 49 50 -= =**WECONLX3VPLC** ==48 += **WECON PLC** = 51 51 52 - Select the protocol (% class="mark"%)"WECONLX3V"50 +== **V-BOX 和维控 LX3V 串行通信** == 53 53 54 - (% class="mark" %)thenset BaudRate,Port,Stop Bit,DataBit,ParitysamewithPLC.52 +Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM 55 55 56 - (%class="mark" %)WECON PLC RS422 port,defaultcommunicationparametersis 9600,1,7,ZEVEN54 +**HMI Settings** 57 57 56 +|**Item**|**Settings**|**Note** 57 +|Protocol|WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM| 58 +|Connection|RS422/RS485| 59 +|Baud rate|9600| 60 +|Data bit|7| 61 +|Parity|EVEN| 62 +|Stop bit|1| 63 +|PLC station No.|1| 64 + 65 +**Address List** 66 + 67 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 68 +|(% rowspan="6" %)Bit|X|X|Xo|0~~303237| 69 +|Y|Y|Y o|0~~303237| 70 +|M|M|M d|0~~99999| 71 +|T|T|T d|0~~99999| 72 +|C|C|C d|0~~99999| 73 +|S|S|S d|0~~99999| 74 +|(% rowspan="8" %)Word|X|X|Xo|0~~303237| 75 +|Y|Y|Y o|0~~303237| 76 +|M|M|M d|0~~99999| 77 +|T|T|T d|0~~99999| 78 +|C|C|C d|0~~199| 79 +|D|D|D d|0~~7999| 80 +|S|S|S d|0~~99999| 81 +|SD|SD|SD d|8000~~9999| 82 + 83 +**Cable Wiring** 84 + 85 +* **RS485** 86 + 87 + [[image:image-20220822172124-1.png]] 88 + 89 +* **RS422** 90 + 91 + [[image:image-20220822172228-2.png]] 92 + 93 + 94 +**✎Note:** 95 + 96 +* HMI COM3 is available in PI8000 series and COM3 is in COM2(hardware PIN 7 and PIN 8) . 97 +* If PLC <= 20 points,such as LX3V-1208/LX3V-0806 PLC,PLC RS485A and RS485B mean PLC COM2 RS485+ and RS485- .PLC COM2 can support modbus. Please refer to PLC COM2 setting manual. 98 + 99 +[[https:~~/~~/drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing>>url:https://drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing]] 100 + 101 + 102 +== **V-BOX and Wecon LX5V serial communication** == 103 + 104 +This example introduces the establishment of serial port communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 105 + 106 +**Software configuration of PLC** 107 + 108 +**1)PLC programming software** 109 + 110 +[[image:image-20220810164710-1.png]] 111 + 112 + 113 +**2)New PLC project** 114 + 115 +Click New Project and select the PLC model. 116 + 117 +[[image:image-20220810172412-1.png]] 118 + 119 + 120 +**3)Set Serial port parameters** 121 + 122 +Follow the steps below to configure Serial port parameters 123 + 124 +Baud rate:115200 125 + 126 +Data bit:8 127 + 128 +Stop bit:1 129 + 130 +Parity:No verification 131 + 132 +[[image:image-20220810165759-3.png]] 133 + 134 + 135 +**4)Registers list** 136 + 137 +[[image:image-20220811102219-3.png]] 138 + 139 + 140 +**HMI software configuration** 141 + 142 +**1)HMI programming software** 143 + 144 + [[image:image-20220810171237-4.png]] 145 + 146 +**2)New HMI project** 147 + 148 +Click New Project and select the HMI model. 149 + 150 +[[image:image-20220810172010-5.png]] 151 + 152 + 153 +**3)Set communication port parameters** 154 + 155 +Click the communication configuration button on the left to find the communication protocol with LX5V. After selecting the protocol, configure the communication parameters of the COM port. 156 + 157 +Baud rate:115200 158 + 159 +Data bit:8 160 + 161 +Stop bit:1 162 + 163 +Parity:No verification 164 + 165 +[[image:image-20220811104012-1.png]] 166 + 167 + 168 +**hardware connection** 169 + 170 +**1)Hardware wiring diagram** 171 + 172 +This example introduces WeconHMI with LX5V PLC to establish communication through serial port. The connection diagram is as follows: 173 + 174 + 175 + 176 +[[image:image-20220811103005-4.png]] 177 + 178 +[[image:image-20220811103227-7.png]] 179 + 180 +The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC. 181 + 182 +== **V-BOX and Wecon LX5V-N Ethernet communication** == 183 + 184 + This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 185 + 186 +**Software configuration of PLC** 187 + 188 +**1)PLC programming software** 189 + 190 +[[image:image-20220810164710-1.png]] 191 + 192 +**2)New PLC project** 193 + 194 +Click New Project and select the PLC model. 195 + 196 +[[image:image-20220811115454-1.png]] 197 + 198 +**3)Set Ethernet port parameters** 199 + 200 +Follow the steps below to configure Ethernet parameters 201 + 202 +PLC IP address:192.168.39.200 203 + 204 +default gateway:192.168.39.1 205 + 206 +subnet mask:255.255.255.0 207 + 208 +[[image:image-20220811140530-2.png]] 209 + 210 +**4)Registers list** 211 + 212 +[[image:image-20220811102219-3.png]] 213 + 214 +**HMI software configuration** 215 + 216 +**1)HMI programming software** 217 + 218 + [[image:image-20220810171237-4.png]] 219 + 220 +**2)New HMI project** 221 + 222 +Click New Project and select the HMI model. 223 + 224 +[[image:image-20220810172010-5.png]] 225 + 226 +**3)Set communication port parameters** 227 + 228 +Click the project setting button on the left to configure the IP address of the HMI machine to ensure that the HMI and PLC IP remain in a local area network. 229 + 230 +HMI IP address:192.168.39.201 231 + 232 +default gateway:192.168.39.1 233 + 234 +subnet mask:255.255.255.0 235 + 236 +[[image:image-20220811170753-2.png]] 237 + 238 +Next, click Communication Settings to configure the IP of the HMI communication object. 239 + 240 +[[image:image-20220811163047-1.png]] 241 + 242 +**hardware connection** 243 + 244 +**1)Hardware wiring diagram** 245 + 246 +This example introduces WeconHMI with LX5V-N PLC to establish communication through ethernet. The connection diagram is as follows: 247 + 248 +[[image:image-20220811170248-1.png]] 249 + 250 +The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC. 251 + 58 58 (% style="text-align:center" %) 59 59 [[image:1624348978863-771.png||queryString="width=812&height=494" height="487" width="800" class="img-thumbnail"]] 60 60 61 -= =**2 Communicationwith Allen-Bradley CompactLogixL1769** ==255 += **Rockwell PLC** = 62 62 257 +== **Communication with AB CompactLogix L1769** == 258 + 63 63 ((( 64 64 ((( 65 65 This example introduces the establishment of Ethernet communication between Wecon V-box and Allen-Bradley L1769. It is introduced through three parts: PLC software configuration, V-box software configuration, and hardware wiring. ... ... @@ -199,7 +199,7 @@ 199 199 200 200 ((( 201 201 ((( 202 -Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device. [[image:image-20220714162752-8.png]]398 +Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device. [[image:image-20220714162752-8.png]] 203 203 ))) 204 204 205 205 ... ... @@ -226,7 +226,7 @@ 226 226 227 227 228 228 ((( 229 -After adding the protocol Allen-BradleyMicro850_FreeTag, click[[image:image-20220714143838-2.png]]icon add label. [[image:image-20220714162827-11.png]]425 +After adding the protocol Allen-BradleyMicro850_FreeTag, click[[image:image-20220714143838-2.png]]icon add label.[[image:image-20220714162827-11.png]] 230 230 ))) 231 231 232 232 (% class="wikigeneratedid" id="HEngineeringproduction" %) ... ... @@ -261,6 +261,14 @@ 261 261 262 262 ((( 263 263 The above are all the steps for establishing Ethernet communication between Wecon V-box with Allen-Bradley L1769 PLC. 460 + 461 + 462 +== **Allen-Bradley Ethernet DF1** == 463 + 464 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]] 465 + 466 + 467 += **Siemens PLC** = 264 264 ))) 265 265 ))) 266 266 ... ... @@ -268,14 +268,12 @@ 268 268 269 269 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]] 270 270 271 -== **Allen-Bradley Ethernet DF1** == 272 - 273 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]] 274 - 275 275 == **Communication with S7-200 Smart** == 276 276 277 277 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]] 278 278 479 += **Delta PLC** = 480 + 279 279 == **Delta DVP Ethernet** == 280 280 281 281 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
- image-20220820164423-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +18.4 KB - Content
- image-20220822172124-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +38.7 KB - Content
- image-20220822172228-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +48.8 KB - Content